LAURITZ KNUDSEN / ELECTRICAL & AUTOMATION

EXORA automatic changeover & current limiters

Automatic changeover with current limiting for specified supply arrangements.

NOVA TRADING RANIGUNJ · SECUNDERABAD
EXORA automatic changeover & current limiters — manufacturer catalog illustration
THE COLLECTION / 2026LAURITZ KNUDSEN

RANGE AT A GLANCE

Choose the right configuration.

Specify the supply arrangement, current rating, required functions and compatible devices. Confirm the exact catalog number and accessory scope.

01

Single-phase ACCL

02

Three-phase ACCL

MANUFACTURER REFERENCE / August 2026

Details, down to
the catalog number.

Browse the supplied specification pages. Published MRP is a dated manufacturer reference; request a current Nova quote and confirm the tax basis and pack size.

EXORA ESP Price List.pdf ↗ · PDF pages 12–12

1 catalog pages

PDF page 12 SPDs (Surge Protection Devices) [8536]
View original PDF page ↗

Extracted reference text; use the original PDF to check column alignment, variants and price units.

SPDs (Surge Protection Devices) [8536]

                          Range Highlights                                 800V Solar Application
                          › Conforms to IEC 61643-11                                                               Modules                                        M.R.P.
                                                                                                                                 Voltage
                          › Available in Type 2 and Type 1+2                 Description Configuration              1 Mod =
                                                                                                                                  (Uc)
                                                                                                                                                 Cat. No.          (`)
                                                                                                                   17.5 mm                                       Per Unit
                          › Type 2 : Protection against indirect
                                                                             Type 2,
                            lightning and switching surges                                            3P              4           1500      AUSP023P40-1500       17250
                                                                             Imax 40kA
                            » Maximum Discharge Current -
                                                                             Type 1+2,
                              Imax up to 70kA                                                         3P              5           1360      AUSP123P50-1360       51750
                                                                             Iimp 12.5kA
                          › Type 1+2 : Protection against direct and
                                                                             Type 1+2,
                            indirect lightning surges                                                 3P              4           880        AUSP123P50-880       35500
                                                                             Iimp 12.5kA
                            » Maximum Discharge Current -
  New
                              Imax up to 100kA


440V Application (Common + Differential Mode)                                            SPD Cartridges
                                     Modules                    M.R.P. (`)
 Description     Imax   Configuration 1 Mod =       Cat. No.                                  Description                                                      M.R.P. (`)
                                                                                                                                             Cat. No.
                                     17.5 mm                    Per Unit                                                                                      Per Unit

 Type 1+2,                  1P+N         2      AUSP121PN50D 13750                           Cartridge for AUSP021PN15D                    AUSC021PN15D         3550
                50kA
 Iimp 12.5kA                3P+N         4      AUSP123PN50D 26335                           Cartridge for AUSP021PN40D                    AUSC021PN40D         4420
                            1P+N         1      AUSP021PN40D       8595                      Cartridge for
 Type 2         40kA                                                                                                                       AUSC021PN70D         4725
                            3P+N         2      AUSP023PN40D 17175                           AUSP021PN70D / AUSP023PN70D
                                                                                                                             #
                            1P+N         1      AUSP021PN15D       6875                      Cartridge for AUSP023PN15D                    AUSC023PN15D         4640
 Type 2         15kA                                                                                                         #
                            3P+N         2      AUSP023PN15D 13525                           Cartridge for AUSP023PN40D                    AUSC023PN40D         5900
 Type 1+2,                  1P+N         2     AUSP121PN100D 12360                           Cartridge for
                100kA                                                                                                                    AUSC121PN100D          7080
 Iimp 8kA                                      AUSP123PN100D 24290                           AUSP121PN100D / AUSP123PN100D
                            3P+N         4
                                                                                             Cartridge for
                            1P+N         2      AUSP021PN70D 13500                                                                         AUSC121PN50D         7645
 Type 2         70kA                                                                         AUSP121PN50D / AUSP123PN50D
                            3P+N         4      AUSP023PN70D 22485                                                           #
                                                                                             Cartridge for AUSP023PN15D                    AUSC023PN15DG        5390
                                                                                                                             #
                                                                                             Cartridge for AUSP023PN40D                    AUSC023PN40DG        5625
                                                                                         #
                                                                                         For technical details, please contact nearest branch office



ACCL (Automatic Changeover with Current Limiter) [8536]

Single Phase ACCL                                                                    Three Phase ACCL
                          Range Highlights                                                                        Range Highlights
                          › Conforms to IEC 60947-6, IEC 60947-3                                                  › Settable overload current limit at DG side
                          › Wide Range of Current Ratings                                                         › Separate power consumption monitoring for
                            » (Generator side) - 1A to 30A                                                          Mains & Genset
                            » (Electricity Board side) - 30A                                                      › Settable overvoltage & undervoltage protection
                          › RoHS compliant                                                                        › Settable TPN or SPN mode at DG side
 Description            Modules                               M.R.P. (`)                                          › Protection against single phasing
                    1 Mod = 17.5 mm          CAT Nos.
 EB/DG                                                        Per Unit
                                                                                             Description (AC-1)                                               M.R.P. (`)
 30A/1A                     4           AUCL01030001            3200                                                                         Cat. No.
                                                                                             EB/DG                                                            Per Unit
 30A/1.5A                   4           AUCL010301E5            3200                         32A / 32A                                     AUCL03032032         22095
 30A/2A                     4           AUCL01030002            3200                         40A / 32A                                     AUCL03040032         22771
 30A/2.5A                   4           AUCL010302E5            3200                         40A / 40A                                     AUCL03040040         24645
 30A/3A                     4           AUCL01030003            3200                         50A / 50A                                     AUCL03050050         35128
 30A/4A                     4           AUCL01030004            3200                         63A / 50A                                     AUCL03063050         38761
 30A/5A                     4           AUCL01030005            3200                         63A / 63A                                     AUCL03063063         43907
 30A/6A                     4           AUCL01030006            3200                         80A / 80A                                     AUCL03080080         66916
 30A/8A                     4           AUCL01030008            3200                         125A / 125A                                   AUCL03125125        112643
 30A/10A                    4           AUCL01030010            3200
 30A/12A                    4           AUCL01030012            3200                                        For 3 Phase ACCL programming video
 30A/15A                    4           AUCL01030015            3200                                        please scan the QR code or click here
 30A/20A                    4           AUCL01030020            3200
 30A/30A                    4          AUCL01030030*            3200
*Non-current limiting variant




                                                                                                                                 Lauritz Knudsen, 15.08.2026            09

BEFORE YOU SPECIFY

Make an informed choice.

LET’S GET THE SPECIFICATION RIGHT

From your shortlist
to a clear quote.

Share the catalog number, rating and quantity. We’ll confirm the current price, availability and lead time.

Send your requirement ↗