LAURITZ KNUDSEN / ELECTRICAL & AUTOMATION
Tripper circuit protection
Protection and distribution products for home electrical systems.

RANGE AT A GLANCE
Choose the right configuration.
Confirm the exact series, finish, module count, electrical rating and matching grid frame or mounting box. Different series should not be assumed interchangeable.
MCBs
RCCBs
RCBOs
ACCL
NXT distribution boards
Enclosures
MANUFACTURER REFERENCE / August 2026
Details, down to
the catalog number.
Browse the supplied specification pages. Published MRP is a dated manufacturer reference; request a current Nova quote and confirm the tax basis and pack size.
Retail Pricelist_Aug 2026.pdf ↗ · PDF pages 5–16
12 catalog pages
PDF page 5 World Class Safety Safety Energy
Extracted reference text; use the original PDF to check column alignment, variants and price units.
World Class Safety Safety Energy Safety Meets Superior True Contact
Standards Redefined Limiting Class - 3 Aesthetics Indication
Tripper products conform to Finger proof terminals eliminate If fault occurs, the rapid Ergonomically designed, profiled Tripper range enhances safety
relevant global standards viz., chances of accidental contact arc quenching mechanism for superior cooling and through true contact indication
IEC, EN and IS. They also have with live parts. You can install, operates and extinguishes the manufactured with fire retardant even from a distance regardless
CE/ISI marking and DEKRA operate and maintain tripper arc quickly, ensuring lowest material. Tripper offers user safety of it’s knob position. Red and
certification. with total confidence. possible energy flow through combined with elegance. Green indication flag positively
the circuit. This minimizes risk of identifies the electrical ON/OFF
fire and maximizes life of your status.
equipment.
Innovatively Profiled Large Terminal Size & Two Position Non-Welding Combihead
Breathing Channels Biconnect DIN Rail Clip Contacts Screw
When two or more poles are Tripper can easily accommodate Installation on a DIN rail is Silver Graphite contact tips Tripper range of products
placed adjacent to each other, cables of up to 35 sq.mm. further simplified with a ensure higher life and maximum provided with combihead
the breathing channels are so Biconnect terminals offer two position DIN rail clip as safety against contact welding screws allow you to use
profiled that the air circulates convenience of connecting both a standard feature. Tripper due to it’s superior anti-welding standard as well as Phillips
around individual pole, cable and bus bar. range makes mounting on properties, enhancing safety screwdrivers, offering flexibility.
resulting in cooler operation, a standard DIN rail more and life of the system.
year after year. convenient.PDF page 6 HIGHLIGHTS
Extracted reference text; use the original PDF to check column alignment, variants and price units.
HIGHLIGHTS
Miniature Circuit Breakers (MCBs) - B CURVE
• marked, marked
• Conforms to IS/IEC 60898 - 6 kA Single Pole
MRP/Unit Std. Pkg.
• Higher life with use of heavy duty contacts Description MW* Cat No
in (Nos.)
• Innovatively designed breathing channels 6A B Curve 1 BA10060B 253 1/12
between poles ensure cooler operation 10A B Curve 1 BA10100B 253 1/12
• Energy saving - watt loss approximately 16A B Curve 1 BA10160B 253 1/12
50% lower than those prescribed 20A B Curve 1 BA10200B 253 1/12
by IEC standard 25A B Curve 1 BA10250B 253 1/12
• Manufactured with high quality 32A B Curve 1 BA10320B 253 1/12
fire retardant material 40A B Curve 1 BA10400B 600 1/12
• True contact indication for enhanced safety
Miniature Circuit Breakers (MCBs) - C CURVE
Single Pole Double Pole Three Pole Four Pole
MRP/Unit Std. Pkg. MRP/Unit Std. Pkg. MRP/Unit Std. Pkg. MRP/Unit Std. Pkg.
Description MW* Cat No MW* Cat No MW* Cat No MW* Cat No
in (Nos.) in (Nos.) in (Nos.) in (Nos.)
6A C Curve 1 BA10060C 253 1/12 2 BA20060C 1025 1/6 3 BA30060C 1695 1/4 4 BA40060C 2285 1/3
10A C Curve 1 BA10100C 253 1/12 2 BA20100C 1025 1/6 3 BA30100C 1695 1/4 4 BA40100C 2285 1/3
16A C Curve 1 BA10160C 253 1/12 2 BA20160C 1025 1/6 3 BA30160C 1695 1/4 4 BA40160C 2285 1/3
20A C Curve 1 BA10200C 253 1/12 2 BA20200C 1025 1/6 3 BA30200C 1695 1/4 4 BA40200C 2285 1/3
25A C Curve 1 BA10250C 253 1/12 2 BA20250C 1025 1/6 3 BA30250C 1695 1/4 4 BA40250C 2285 1/3
32A C Curve 1 BA10320C 253 1/12 2 BA20320C 1025 1/6 3 BA30320C 1695 1/4 4 BA40320C 2285 1/3
40A C Curve 1 BA10400C 600 1/12 2 BA20400C 1535 1/6 3 BA30400C 2420 1/4 4 BA40400C 2960 1/3
63A C Curve 1 BA10630C 668 1/12 2 BA20630C 1710 1/6 3 BA30630C 2595 1/4 4 BA40630C 3150 1/3
*Module Width: 1 Mod = 17.5 mm
6 Lauritz Knudsen, 15.08.2026PDF page 7 HIGHLIGHTS
Extracted reference text; use the original PDF to check column alignment, variants and price units.
HIGHLIGHTS
RESIDUAL CURRENT CIRCUIT BREAKERS (RCCBs/ELCBs)
• marked, marked
• Conforms to IS 12640 - 1, IEC 61008-1 Double Pole Four Pole
MRP/Unit Std. Pkg. MRP/Unit Std. Pkg.
• Available in DP & FP versions from Description MW* Cat No
in (Nos.)
MW* Cat No
in (Nos.)
25A to 63A ratings with 30mA, 25A 30mA 2 BC202503 3145 1 4 BC402503 4410 1
100mA & 300mA sensitivity 25A 100mA 2 BC202510 3470 1 4 BC402510 4490 1
• Operates on Core Balance 25A 300mA 2 BC202530 3470 1 4 BC402530 4490 1
Current Transformer (CBCT) principle New 32 A 30mA 2 BC203203 3565 1 4 BC403203 4475 1
• Finger proof IP20 terminals New 32A 100mA 2 BC203210 3680 1 4 BC403210 4570 1
New 32A 300mA 2 BC203230 3680 1 4 BC403230 4570 1
40A 30mA 2 BC204003 3565 1 4 BC404003 4475 1
40A 100mA 2 BC204010 3680 1 4 BC404010 4570 1
40A 300mA 2 BC204030 3680 1 4 BC404030 4570 1
63A 30mA 2 BC206303 4555 1 4 BC406303 4940 1
63A 100mA 2 BC206310 4840 1 4 BC406310 5100 1
63A 300mA 2 BC206330 4840 1 4 BC406330 5100 1
New 100A 30mA 2 BC210003 7945 1 4 BC410003 8745 1
New 100A 100mA 2 BC210010 8120 1 4 BC410010 9060 1
New 100A 300mA 2 BC210030 8120 1 4 BC410030 9060 1
Isolators
HIGHLIGHTS
Double Pole Three Pole Four Pole
• marked MRP/Unit Std. Pkg. MRP/Unit Std. Pkg. MRP/Unit Std. Pkg.
Description MW* Cat No MW* Cat No MW* Cat No
in (Nos.) in (Nos.) in (Nos.)
• Conforms to IEC 60947 - 3
40A Isolator 2 BE204000 670 1/6 3 BE304000 1185 1/4 4 BE404000 1525 1/3
• Higher life with use of heavy duty contacts
63A Isolator 2 BE206300 835 1/6 3 BE306300 1355 1/4 4 BE406300 1585 1/3
• Innovatively designed breathing channels between poles
100A Isolator 2 BE210000 1160 1/6 3 BE310000 1600 1/4 4 BE410000 1910 1/3
ensure cooler operation
• Manufactured with high quality fire retardant material
• True contact indication for enhanced safety
*Module Width: 1 Mod = 17.5 mm
Lauritz Knudsen, 15.08.2026 7PDF page 8 HIGHLIGHTS
Extracted reference text; use the original PDF to check column alignment, variants and price units.
HIGHLIGHTS
Automatic Changeover with current limiter(ACCL)
• marked MRP/Unit Std. Pkg.
Description EB/DG MW* Cat No
• Conforms to IEC 60947-6, IEC 60947-3 in (Nos.)
New 30A/1A 4 BCL01030001 2500 1
• Wide Range of Current Ratings
30A/1.5A 4 BCL010301E5 2500 1
Generator Side - 1.5A to 30A New 30A/2A 4 BCL01030002 2500 1
Electricity Board Side - 30A 30A/2.5A 4 BCL010302E5 2500 1
• No. of Poles 1P+N, for single phase applications 30A/3A 4 BCL01030003 2500 1
• Protection Degree - IP20 30A/4A 4 BCL01030004 2500 1
30A/5A 4 BCL01030005 2500 1
• Reliable microcontroller based design for sensing & control 30A/6A 4 BCL01030006 2500 1
• Lower power consumption 30A/8A 4 BCL01030008 2500 1
• RoHS compliant 30A/10A 4 BCL01030010 2500 1
30A/12A 4 BCL01030012 2500 1
30A/15A 4 BCL01030015 2500 1
30A/20A 4 BCL01030020 2500 1
30A/30A# 4 BCL01030030 2500 1
#
Non current limiting variant
HIGHLIGHTS
• Settable overload current limit at DG side THREE Phase Automatic Changeover with Current Limiter (3Ph ACCL) NEW
• Separate power consumption monitoring for Mains & Genset MRP/Unit Std. Pkg.
Description ( AC-1) EB/DG Cat No
in (Nos.)
• Settable overvoltage & undervoltage protection 32A / 32A AUCL03032032 22095 1
• Settable TPN or SPN mode at DG side 40A / 32A AUCL03040032 22771 1
• Protection against single phasing 40A / 40A AUCL03040040 24645 1
50A / 50A AUCL03050050 35128 1
For 3 Phase ACCL programming video 63A / 50A AUCL03063050 38761 1
please scan the QR code or click here 63A / 63A AUCL03063063 43907 1
80A / 80A AUCL03080080 66916 1
125A / 125A AUCL03125125 112643 1
HIGHLIGHTS
MODULAR Changeover Switches
• Conforms to IEC 60947-3
• Available with 3 positions (I-O-II) with Double Pole Four Pole
centre off position MRP/Unit Std. Pkg. MRP/Unit Std. Pkg.
Description MW* Cat No Description MW* Cat No
in (Nos.) in (Nos.)
• Utilization category AC-22A 25A 2 AUC00202500 2610 1 40A 4 AUC00404000 6885 1
40A 2 AUC00204000 3995 1 63A 6 AUC00406300 7805 1
63A 3 AUC00206300 4645 1
*Module Width: 1 Mod = 17.5 mm
8 Lauritz Knudsen, 15.08.2026PDF page 9 HIGHLIGHTS
Extracted reference text; use the original PDF to check column alignment, variants and price units.
HIGHLIGHTS
Residual Current Circuit Breaker with Over Current Protection (RCBOs) NEW
• marked, marked
• Conforms to IS 12640-2, IEC 61009-1, Double Pole
Cat No MRP/Unit Std. Pkg. Cat No MRP/Unit Std. Pkg. Cat No MRP/Unit Std. Pkg.
EN 61009-1 Description MW*
(30 mA) in (Nos.)
MW*
(100 mA) in (Nos.)
MW*
(300 mA) in (Nos.)
• Short Circuit Breaking Capacity - 10kA 6A 2P RCBO 2 AUF3C200603 7115 1 2 AUF3C200610 7260 1 2 AUF3C200630 7345 1
• Wide range of current ratings - 6A to 100A 10A 2P RCBO 2 AUF3C201003 7115 1 2 AUF3C201010 7260 1 2 AUF3C201030 7345 1
• Suitable for Isolation 16A 2P RCBO 2 AUF3C201603 7115 1 2 AUF3C201610 7260 1 2 AUF3C201630 7345 1
• Safety Shutter 20A 2P RCBO 2 AUF3C202003 7115 1 2 AUF3C202010 7260 1 2 AUF3C202030 7345 1
• Line-load Reversibility 25A 2P RCBO 2 AUF3C202503 7115 1 2 AUF3C202510 7260 1 2 AUF3C202530 7345 1
• True Position Indication 32A 2P RCBO 2 AUF3C203203 7115 1 2 AUF3C203210 7260 1 2 AUF3C203230 7345 1
• Trip-free Mechanism 40A 2P RCBO 2 AUF3C204003 7115 1 2 AUF3C204010 7260 1 2 AUF3C204030 7345 1
• Easy fault identification -
63A 2P RCBO 4 AUF3C206303 8610 1 4 AUF3C206310 9130 1 4 AUF3C206330 9200 1
1. Short Circuit fault Indication :
Clear indication by amber coloured flag
2. Earth Leakage Fault Indication :
Clear indication by yellow coloured flag
Residual Current Circuit Breaker with Over Current Protection (RCBOs) NEW
Four Pole
Cat No MRP/Unit Std. Pkg. Cat No MRP/Unit Std. Pkg. Cat No MRP/Unit Std. Pkg.
Description MW* MW* MW*
(30 mA) in (Nos.) (100 mA) in (Nos.) (300 mA) in (Nos.)
C16A 4P RCBO 7.5 AUF3C401603 7780 1 7.5 AUF3C401610 8660 1 7.5 AUF3C401630 8835 1
C20A 4P RCBO 7.5 AUF3C402003 7780 1 7.5 AUF3C402010 8660 1 7.5 AUF3C402030 8835 1
C25A 4P RCBO 7.5 AUF3C402503 7780 1 7.5 AUF3C402510 8660 1 7.5 AUF3C402530 8835 1
C32A 4P RCBO 7.5 AUF3C403203 8035 1 7.5 AUF3C403210 8665 1 7.5 AUF3C403230 8860 1
C40A 4P RCBO 7.5 AUF3C404003 8160 1 7.5 AUF3C404010 8665 1 7.5 AUF3C404030 8890 1
C63A 4P RCBO 7.5 AUF3C406303 9780 1 7.5 AUF3C406310 9965 1 7.5 AUF3C406330 9965 1
C80A 4P RCBO 12 AUF3C408003 37895 1 12 AUF3C408010 38745 1 12 AUF3C408030 38745 1
C100A 4P RCBO 12 AUF3C410003 40515 1 12 AUF3C410010 41485 1 12 AUF3C410030 41485 1
*Module Width: 1 Mod = 17.5 mm
Lauritz Knudsen, 15.08.2026 9PDF page 10 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 11 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 12 NXT
Extracted reference text; use the original PDF to check column alignment, variants and price units.
NXT
SPN DISTRIBUTION BOARDS
SPN Distribution Boards NEW
• Available in 4, 6, 8, 12 & 16 way
Modules MRP/Unit Double Door - MRP/Unit
• Ready to use DBs, complete with colour - coded wire set, Description Double Door
in Glazed in
Incomer Outgoing
100A insulated bus bar, Neutral bar/s with shroud/s, Earth
4-Way 2 2 DTSPN004DD 2060 DTSPN004GD 2710
bar/s, Cement Spill Protector, Cable ties, Blanking plates
6-Way 2 4 DTSPN006DD 2415 DTSPN006GD 2900
and Circuit identification label
8-Way 2 6 DTSPN008DD 2565 DTSPN008GD 3165
• Choice of metal and glazed door
12-Way 2 10 DTSPN012DD 3085 DTSPN012GD 3840
• With provision for DP MCB/Isolator/RCCB/RCBO
16-Way 2 14 DTSPN016DD 3865 DTSPN016GD 4745
as incomer and SP MCBs as outgoings
18-Way 2 16 DTSPN018DD 4020 DTSPN018GD 5025
TPN DISTRIBUTION BOARDS
TPN Distribution Boards NEW
• Available in 4, 6, 8 & 12 way
Modules MRP/Unit Double Door - MRP/Unit
• Ready to use DBs, complete with colour - coded wire set, Description Double Door
in Glazed in
Incomer Outgoing
100A insulated bus bars, Neutral bar/s with
4-Way 8 4+4+4 DTTPN004DD 5100 DTTPN004GD 6650
shroud/s, Earth bar/s, Cement Spill Protector, Cable ties,
6-Way 8 6+6+6 DTTPN006DD 6360 DTTPN006GD 8255
Blanking plates and Circuit identification label
8-Way 8 8+8+8 DTTPN008DD 7600 DTTPN008GD 9870
• Choice of metal and glazed door
12-Way 8 12+12+12 DTTPN012DD 11310 DTTPN012GD 15110
• With provision for FP MCB/Isolator/RCCB/RCBO as incomer
and SP MCBs as outgoings
HORIZONTAL PPI (PER PHASE ISOLATION) DBs
Horizontal PPI (Per Phase Isolation) DBs NEW
• Available in 4, 6, 8 & 12 way
Modules MRP/Unit
• Ready to use DBs, complete with colour - coded wire set, 100A Description Double Door
Incomer Sub-Incomer Outgoing in
insulated bus bars, Neutral bar/s with shroud/s, Earth bar/s,
4-Way 8 2+2+2 4+4+4 DTHPI004DD 8425
Cement Spill Protector, Cable ties, Blanking plates and
6-Way 8 2+2+2 6+6+6 DTHPI006DD 10100
Circuit identification label
8-Way 8 2+2+2 8+8+8 DTHPI008DD 12045
• With provision for FP MCB/Isolator/RCCB/RCBO as incomer, DP
12-Way 8 2+2+2 12+12+12 DTHPI012DD 16410
RCCB/RCBO as sub-incomer and SP MCBs as outgoings
12 Lauritz Knudsen, 15.08.2026PDF page 13 NXT
Extracted reference text; use the original PDF to check column alignment, variants and price units.
NXT
Flexi/ROW DBs
Flexi/ROW DBs NEW
• Available in 2 Row 28 Mod, 3 Row 42 Mod, 3 Row 56 Mod,
IP 43 MRP/Unit
4 Row 64 Mod Description Modules
Metal Door in
• Ready to use DBs, complete with colour - coded wire set, 100A
2 Row 28 Module 14 DTROW228DD 6775
insulated bus bars, Neutral bar/s with shroud/s, Earth bar/s,
3 Row 42 Module 14 DTROW342DD 8120
Cement Spill Protector, Cable ties, Blanking plates and Circuit
4 Row 56 Module 14 DTROW456DD 8830
identification label
4 Row 64 Module 16 DTROW464DD 10275
• Gives flexbility to customer to mount modular devices as per
requirement
PHASE SEGREGATED DBs
Phase Segregated DBs NEW
• Available in 4, 6, 8 & 12 way
Modules MRP/Unit
• Ready to use DBs, complete with colour - coded wire set, 100A Description Double Door
in
Incomer Sub-Incomer Outgoing
insulated bus bars, Neutral bar/s with shroud/s, Earth bar/s,
4-Way 8 4+4+4 4+4+4 DTPSG004DD 13275
Cement Spill Protector, Cable ties, Blanking plates and Circuit
6-Way 8 4+4+4 6+6+6 DTPSG006DD 14990
identification label
8-Way 8 4+4+4 8+8+8 DTPSG008DD 16735
• With provision for FP MCB/Isolator as incomer, DP RCCB/RCBO
12-Way 8 4+4+4 12+12+12 DTPSG012DD 21120
as sub-incomer and SP MCBs as outgoings
PHASE SELECTOR DBs
Phase Selector DBs NEW
• Available in 4, 6, 8 & 12 way
• Provided with 63A Selector Switches Description
Modules
Double Door
MRP/Unit
in
• Ready to use DBs, complete with colour - coded wire set, 100A insulated Incomer Outgoing
bus bars, Neutral bar/s with shroud/s, Earth bar/s, Cable ties, 4-Way 8 4+4+4 DTPSR004DD 15825
Blanking plates and Circuit identification label 6-Way 8 6+6+6 DTPSR006DD 16205
• With provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP MCBs 8-Way 8 8+8+8 DTPSR008DD 17185
as outgoings 12-Way 8 12+12+12 DTPSR012DD 19280
VTPN DBs WITH MODULAR INCOMER
VTPN DBs with Modular Incomer NEW
• Available in 4, 6, 8 & 12 way
Modules MRP/Unit
• Ready to use DBs, complete with colour - coded wire set, Description Double Door
in
Incomer Outgoing
Insulated vertical phase bus bars, Neutral bar/s with shroud/s,
4-Way 8 4+4+4 DTVTM004DD 12205
Earth bar/s, Cement Spill Protector, Cable ties, Blanking plates
6-Way 8 6+6+6 DTVTM006DD 14035
and Circuit identification label
8-Way 8 8+8+8 DTVTM008DD 16285
• With provision for FP MCB/Isolator/RCCB/RCBO as incomer
12-Way 8 12+12+12 DTVTM012DD 21545
and SP/TP MCBs as outgoings
Lauritz Knudsen, 15.08.2026 13PDF page 14 VTPN DBs WITH MCCB INCOMER
Extracted reference text; use the original PDF to check column alignment, variants and price units.
VTPN DBs WITH MCCB INCOMER
VTPN DBs WITH MCCB INCOMER NEW
• Available in 4, 6, 8 & 12 way
Modules MRP/Unit
• Ready to use DBs, complete with colour - coded wire set, Insulated Description Double Door
in
Incomer Outgoing
vertical phase bus bars, Neutral bar/s with shroud/s, Earth bar/s,
4-Way MCCB 4+4+4 DTVTL004DD 14570
Cement Spill Protector, Cable ties, Blanking plates and Circuit
6-Way MCCB 6+6+6 DTVTL006DD 17050
identification label
8-Way MCCB 8+8+8 DTVTL008DD 18515
• With provision for MCCB as incomer and SP/TP MCBs as outgoings
12-Way MCCB 12+12+12 DTVTL012DD 23945
• Suitable for 3P/4P MCCB as incomer upto 125A - DY125U
DBS WITH PROVISION FOR TV / TELEPHONE
DBs with provision for TV /
SPLITTERS NEW
Telephone splitters
• Distribution Boards equipped with provisions to mount
DB Modules IP 43 MRP/Unit
TV / Telephone s plitters Description
Type Incomer Outgoing Metal Door in
• Available in SPN & TPN Dbs 6 way 2 4 DTSPN006DDTV 4715
• Communication DB equipped with provisions to mount 2 ONT, 8 way 2 6 DTSPN008DDTV 5065
Spike guard, Data switch, TV / Telephone splitters SPN 12 way 2 10 DTSPN012DDTV 6235
16 way 2 14 DTSPN016DDTV 7235
18 way 2 16 DTSPN018DDTV 8565
4 way 8 4+4+4 DTTPN004DDTV 9265
TPN 6 way 8 6+6+6 DTTPN006DDTV 10705
8 way 8 8+8+8 DTTPN008DDTV 12765
Communication DB DTCOM01DD *
EV CHARGING DB
EV CHARGING DB NEW
• Engineered specifically Charging application-3.3kW
IP 43 MRP/Unit
• Robust earth leakage, short circuit and overload protection Description Modules
Metal Door in
with RCBO
2 way EVDB 2 DTEVC002LD *
• Factory fitted RCBO, switch and socket
4 way EVDB 4 DTEVC004LD *
*For details, please contact nearest branch office
14 Lauritz Knudsen, 15.08.2026PDF page 15 NXT
Extracted reference text; use the original PDF to check column alignment, variants and price units.
NXT
ENCLOSURES
Enclosures NEW
• Available in 2, 3, 4 & 6 way
MRP/Unit
• With provision to mount MCB/Isolator/RCCB/RCBO or Description Modules Single Door
in
other modular devices 2-Way 2 DTENC002SD 605
3-Way 3 DTENC003SD 675
4-Way 4 DTENC004SD 675
Single Door 6-Way 6 DTENC006SD 1020
PLUG & SOCKET DBs
Plug & Socket DBs NEW
• SPN 10A & 20A; TPN - 32A
MRP/Unit
• With provision to mount MCBs/RCCBs Description No. of Pins Modules Single Door
in
10A, 2 Pin+SC^ P+N 1 DTMPS110SD 1535
20A, 2 Pin+SC^ P+N 1 DTMPS120SD 1640
Single Door
20A, 2 Pin+SC^ P+N 2 DTMPS220SD 1785
32A, 3 Pin+SC^ 3P 3 DTMPS332SD 4230
SC^ - Scrapping Earth
METAL PLUG & SOCKET
MRP/Unit
Description No. of Pins Cat No
in
METAL PLUG & SOCKET Metal Plug
• Designed to ensure safe functioning of electrical 10A, 2 Pin+SC^ P+N MPS210P 335
equipment and the user safety 20A, 2 Pin+SC^ P+N MPS220P 355
• Plugs & Sockets find its applications at air conditioners, 20A, 3 Pin+SC^ 3P MPS320P 475
welding machines, industrial equipment, etc., are made of 32A, 3 Pin+SC^ 3P MPS332P 900
non corrosive aluminum alloy Metal Socket
• Conforms to IS 8804 10A, 2 Pin+SC^ P+N MPS210S 350
20A, 2 Pin+SC^ P+N MPS220S 390
20A, 3 Pin+SC^ 3P MPS320S 530
32A, 3 Pin+SC^ 3P MPS332S 900
SC^ - Scrapping Earth
Note: Standard Pack Quantity for Metal Plug & Socket - 20 Nos.
Lauritz Knudsen, 15.08.2026 15PDF page 16 Single Phase Neutral (SPN) DBs
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Single Phase Neutral (SPN) DBs
Modules MRP/Unit MRP/Unit
Description Single Door Double Door
in in
Incomer Outgoing
4 way 2 2 BH104SDB 1150 BH104DDB 1840
6 way 2 4 BH106SDB 1260 BH106DDB 2065
8 way 2 6 BH108SDB 1425 BH108DDB 2250
12 way 2 10 BH112SDB 1895 BH112DDB 2745
Single Door Double Door
16 way 2 14 BH116SDB 2365 BH116DDB 3380
HIGHLIGHTS THREE Phase Neutral (TPN) DBs
• Ready to use DBs, complete Modules MRP/Unit MRP/Unit
Description Single Door Double Door
in in
with colour - coded wire set, Incomer Outgoing
100A bus bar, 4 way 8 4+4+4 BH304SDB 3555 BH304DDB 4595
Neutral bar/s & Earth bar/s 6 way 8 6+6+6 BH306SDB 4395 BH306DDB 5645
• Superior quality powder 8 way 8 8+8+8 BH308SDB 5075 BH308DDB 6845
coating for better looks and 12 way 8 12+12+12 BH312SDB 7205 BH312DDB 9850
longer life Double Door
• DB is suitable for surface or
flush mounting
Phase Selector DBs
Phase Selector DBs
Modules MRP/Unit
Description Double Door
in
Incomer Outgoing
4 way 8 4+4+4 BHC04DDB 14465
6 way 8 6+6+6 BHC06DDB 15105
Double Door
Provided with 40A selector switches
16 Lauritz Knudsen, 15.08.2026No matching text found. Try a shorter model code or check the original PDF, including illustrated pages.
BEFORE YOU SPECIFY
Make an informed choice.
LET’S GET THE SPECIFICATION RIGHT
From your shortlist
to a clear quote.
Share the catalog number, rating and quantity. We’ll confirm the current price, availability and lead time.