LAURITZ KNUDSEN / ELECTRICAL & AUTOMATION
Contactors, accessories & spares
Switching components for motor and control circuits.

RANGE AT A GLANCE
Choose the right configuration.
Share supply voltage, load or motor details, control requirements, enclosure conditions and required accessories for model selection.
MNX, MCX and MO contactors
Control relays
Auxiliary blocks
Connecting links
Coils and contact kits
MANUFACTURER REFERENCE / August 2026
Details, down to
the catalog number.
Browse the supplied specification pages. Published MRP is a dated manufacturer reference; request a current Nova quote and confirm the tax basis and pack size.
ESP Lauritz Knudsen Price List (1).pdf ↗ · PDF pages 10–18
9 catalog pages
PDF page 10 Contactors
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Contactors
Power Contactors Control Relays Capacitor Duty
2 Pole 3 Pole 4 Pole (Auxiliary Contactors) Contactors
› MNX › MO › MCX › MX0 (Mini) AC/DC › MO C
› MNX
› MU-2P › MO0 AC/DC
› MI
› MX Power
› ML
› MDX (DC Control/Electronic coil Control)
MI Contactors
6-150A, AC-3 Rating
Optimum solution
for your applications
Understanding customer requirements, we make sure that our range of contactors caters to their evolving needs. Considering the
changing expectations of customers and a need for an optimum and reliable solution, we introduce MI range of contactors for
applications upto 150 A AC3 rating.
M.R.P. (`)
Type Cat. No.
Features Per Unit
› Finger proof terminals upto 40A MI 6 (With 1 NO aux contact) CS90401
› Can be used with existing MN Range of thermal overload relays MI 9 (With 1 NO aux contact) CS90402
› Top mounting add-on blocks possible upto 80A MI 12 (With 1 NO aux contact) CS90403
› Spares available for entire range MI 18 (With 1 NO aux contact) CS90404
› Optimised for AC1/AC3 applications MI 22 (With 1 NO aux contact) CS90405
MI 25 (With 1 NO aux contact) CS90406 Price
Applications on
MI 25 CS92912#
› Street lighting MI 32 CS90407
Request*
› VFD, Soft Starters applications MI 40 CS90408
› UPS MI 45 CS90704
› Solar and Wind inverters MI 50 CS90705
› Resistive loads MI 70 CS90706
› Battery charging MI 80 CS90707
› Motor Starters MI 95 CS90724
* For accessories and more details please contact nearest branch. MI 120 CS90725
MI 150 CS90726
Notes:
1) Standard coil voltage: 110V, 220V, 240V and 415V, 50Hz
2) For ordering Suffix, please refer page No. 10
3) # For 2 no. of 4 sq. mm wires with lugs in single terminal
4) MI6-25 Available with 1NC on Request
Lauritz Knudsen, 15.08.2026 03PDF page 11 3 Pole Power Contactors [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
3 Pole Power Contactors [8536]
3 Pole Power Contactors - Type MNX 3 Pole Power Contactors - Type MO
Features Features
› Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 › Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1
› Range from 9A – 650A AC-3 › Range from 9A - 300A AC-3
› Click fit type construction up to 40A › Range 140A-300A available with conventional / universal AC/DC
› Coil on top design in 95A and above electronic coil version
› Spares available for entire range › Common coil for 50 & 60Hz application
› Low pick-up VA consumption
› Standardized accessories for 9A-110A and 140A-300A range
› Compact dimensions saving panel space
› Suitable for Lug as well as Lugless termination
› RoHS compliant
MNX 22 MNX 40 MNX 80
MO 18 MO 45 MO 70 MO 110 MO 140 MO 250
MNX 140 MNX 250 MNX 650
AC 4 AC 3e AC 1 M.R.P. Std.
Type Aux.
AC3 AC1 M.R.P. Std. Size Rating Rating Rating Cat. No. (`) Pkg.
Aux. Contacts
Size Rating Rating Type Cat. No. (`) Pkg. (A) (A) (A) Per Unit (Nos.)
Contacts
(A) (A) Per Unit (Nos.) 1 NO CS94833 2970 10
9 9 30 MO 9
1 NO CS94106 1550 20 1NC CS92918 2970 10
9 25 MNX 9
1 NC CS94107 1550 20 1 NO CS94834 3320 10
Fr 0 12 12 32 MO 12
1 NO CS94108 1800 20 1 NC CS92919 3320 10
12 30 MNX 12
1 NC CS94109 1800 20 1 NO CS94835 4010 10
Fr 1 18 18 32 MO 18
1 NO CS94100 2140 20 1 NC CS92920 4010 10
18 30 MNX 18
1 NC CS94101 2140 20 25 25 45 MO 25 # CS94567 5240 10
MNX 22 1 NO CS94980 2670 20 32 32 50 MO 32 # CS94568 9760 10
22 32
1 NC CS94981 2670 20 Fr 1 40 40 50 MO 40 # CS94569 14190 10
25 45 MNX 25 # CS94110 2730 20 45 45 50 MO 45 # CS94570 20590 10
Fr 2 32 55 MNX 32 # CS94111 5320 20 50 50 100 MO 50 # CS94572 20900 1
40 55 MNX 40 # CS94190 7880 20 Fr 2 60 60 100 MO 60 # CS94573 28560 1
50 85 MNX 50 # CS97075 11470 1 70 70 100 MO 70 # CS94574 29100 1
Fr 3 70 100 MNX 70 # CS97076 16160 1 80 80 125 MO 80 # CS94576 35890 1
80 100 MNX 80 # CS97077 20170 1 Fr 3 95 95 125 MO 95 # CS94577 45510 1
95 160 MNX 95 2 NO + 2 NC CS94136 33910 1 110 110 140 MO 110 # CS94578 55350 1
Fr 4 110 160 MNX 110 2 NO + 2 NC CS94137 41370 1 140 140 250 MO 140 2 NO + 2 NC CS95000 71450 1
140 160 MNX 140 2 NO + 2 NC CS94138 52760 1 Fr 4 185 185 275 MO 185 2 NO + 2 NC CS95001 90380 1
185 250 MNX 185 2 NO + 2 NC CS94139 64390 1 225 225 275 MO 225 2 NO + 2 NC CS95002 97180 1
Fr 5 225 300 MNX 225 2 NO + 2 NC CS94140 71760 1 140 140 250 MO 140 2 NO + 2 NC CS95042 93520 1
250 300 MNX 250 2 NO + 2 NC CS94141 80210 1 Fr 4* 185 185 275 MO 185 2 NO + 2 NC CS95047 125770 1
300 400 MNX 300 2 NO + 2 NC CS90280 96890 1 225 225 275 MO 225 2 NO + 2 NC CS95052 129110 1
400 425 MNX 400 2 NO + 2 NC CS94144 140960 1 250 250 400 MO 250 2 NO + 2 NC CS94441 118090 1
Fr 6 Fr 5
550 650 MNX 550 2 NO + 2 NC CS94145 207040 1 300 300 500 MO 300 2 NO + 2 NC CS94440 141720 1
650 800 MNX 650 2 NO + 2 NC CS96327 309720 1 250 250 400 MO 250 2 NO + 2 NC CS94456 152580 1
Fr 5*
Notes: 300 300 500 MO 300 2 NO + 2 NC CS94464 175700 1
1) # Add-on blocks can be ordered separately
2) For ordering MNX/MO add-on aux contact blocks, please refer page No.8
3) For ordering MNX/MO surge suppressor and MNX/MO MIL kit, please
refer page No.9
4) For ordering Suffix, please refer page No.10
5) Standard coil voltage: MNX/MO - 110V, 220V, 240V and 415V, 50Hz.
If using 16 sq mm cable for MO 45 use of spreader link kit is mandatory
AC-15 AC-3/3e
For ordering spreader link kit for MO 45, Please refer page No.9
* Universal AC/DC electronic coil version
AC-8a/8b
AC-4
AC-6a
AC-5a/5b
AC-6b AC-1
Lauritz Knudsen, 15.08.2026 04PDF page 12 2 Pole Power Contactors [8536] 3 Pole
Extracted reference text; use the original PDF to check column alignment, variants and price units.
2 Pole Power Contactors [8536] 3 Pole Power Contactors [8536]
2 Pole Power Contactors - Type MNX 3 Pole Power Contactors - Type MDX
Features Features
› Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 › Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
› Range from 9A - 650A AC-3 › Range from 9 - 115A AC-3
› DC ratings available › Built in surge suppressor for MDX 9 - 115
› Click fit type construction up to 40A
› Coil on top design in 95A and above
› Common spares and accessories as MNX 3P
AC3 AC1 M.R.P. Std.
Type Aux.
Size Rating Rating Cat. No. (`) Pkg.
Contacts
(A) (A) Per Unit (Nos.) MDX 25 MDX 38 MDX 115
9 25 MNX 9-2P 1 NO CS90232 1320 10 AC3 AC1 M.R.P. Std.
Type Aux.
12 30 MNX 12-2P 1 NO CS90234 1530 10 Size Rating Rating Cat. No. (`) Pkg.
Fr 1 Contacts
18 30 1820 10 (A) (A) Per Unit (Nos.)
MNX 18-2P 1 NO CS90236
22 32 MNX 22-2P 1 NO CS90238 2270 10 9 25 MDX 9 1 NO CS96564 4500 1
Fr 1 12 28 MDX 12 1 NO CS96565 5150 1
25 45 MNX 25-2P # CS90240 2320 10 (DC Control
Fr 2 32 55 MNX 32-2P # CS90241 4520 10 Coil) 18 32 MDX 18 1 NO CS96566 6140 1
40 55 MNX 40-2P # CS90242 6700 10 25 32 MDX 25 1 NO CS96567 13730 1
Fr 2 32 56 MDX 32 # CS96552 17500 1
50 85 MNX 50-2P # CS94061 10100 1 (DC Control
Fr 3 70 100 MNX 70-2P # CS94062 14230 1 Coil) 38 56 MDX 38 # CS96553 23220 1
80 100 MNX 80-2P # CS94063 17900 1 50 90 MDX 50 # CS91584 31610 1
95 160 MNX 95-2P # CS94064 28600 1 Fr 3 65 110 MDX 65 # CS91585 35790 1
(Electronic 80 125 MDX 80 # CS91586 44390 1
Fr 4 110 160 MNX 110-2P # CS94065 34900 1 Coil-AC/DC)
95 125 MDX 95 # CS91857 53630 1
140 160 MNX 140-2P # CS94066 44500 1
115 125 MDX 115 # CS91858 60270 1
185 250 MNX 185-2P 2 NO + 2 NC CS94978 55700 1
* MDX Available till stock lasts
Fr 5 225 300 MNX 225-2P 2 NO + 2 NC CS94979 62600 1
250 300 MNX 250-2P 2 NO + 2 NC CS90301 69900 1 Notes:
300 400 MNX 300-2P 2 NO + 2 NC CS90346 84500 1 1) # Add-on blocks can be ordered separately.
400 425 123900 1 2) For ordering MDX/MNX add-on aux contact blocks, please refer page No.8
MNX 400-2P 2 NO + 2 NC CS94069
Fr 6 3) For ordering MNX surge suppressor and MIL kit, please refer page No.9
550 650 MNX 550-2P 2 NO + 2 NC CS90243 182100 1
4) For ordering Suffix, please refer page No.10
650 800 MNX 650-2P 2 NO + 2 NC CS90578 272300 1 5) Standard coil voltage: MDX - 24V, 48V, 115V and 220V DC
6) Standard coil voltage: MNX 2P - 240V, 50Hz
7) For DC power ratings refer catalogue
8) For MDX side add-on and top add-on can not be mounted together
3 Pole Power Contactors [8536]
3 Pole Power Contactors - Type MX Mini 3 Pole Power Contactors - Type ML
Features Features
› Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 › Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
› AC/DC Contactor in 45mm width › Range from 25A- 300A AC-3
› Base as well as DIN Rail mounting facility › Robust and suitable for hostile applications
› Built-in Surge Suppressor in MX DC
MX 06 ML 1.5 ML 3
AC3 AC1 M.R.P. Std. AC3 AC1 M.R.P. Std.
Type Aux. Type Aux.
Rating Rating Cat. No. (`) Pkg. Size Rating Rating Cat. No. (`) Pkg.
Contact Contacts
(A) (A) Per Unit (Nos.) (A) (A) Per Unit (Nos.)
For AC control (Std. Coil Voltage - 24, 110, 240, 415V, 50Hz) Fr 1 25 25 ML 1.5 2 NO + 2 NC SS91851 10190 1
6A 20A MX 06 1 NO CS94012 2020 10 32 40 ML 2 2 NO + 2 NC SS90701 18930 1
Fr 2
6A 20A MX 06 1 NC CS94013 2020 10 40 45 ML 3 2 NO + 2 NC SS90721 27910 1
9A 20A MX 09 1 NO CS94014 2070 10 70 100 ML 4 2 NO + 2 NC SS90910 45600 1
Fr 3
9A 20A MX 09 1 NC CS94015 2070 10 110 125 ML 6 2 NO + 2 NC SS90921 72160 1
12A 20A MX 12 1 NO CS94016 2290 10 Fr 4 300 400 ML 12 2 NO + 2 NC SS91010 163350 1
12A 20A MX 12 1 NC CS94017 2290 10
Notes:
For DC control (Std. Coil Voltage - 24, 110, 220V) 1) For ordering MX add-on aux contact blocks, please refer page No.8
6A 20A MX 06 1 NO CS94021 3120 10 2) For ordering ML add-on aux contact blocks, please refer page No.9
6A 20A MX 06 1 NC CS94022 3120 10 3) For ordering MX surge suppressor and MIL kit, please refer page No.9
9A 20A MX 09 1 NO CS94023 3310 10 4) For Ordering Suffix, please refer page No.10
5) Standard Coil Voltage : ML 1.5/2/3 - 110V, 240V and 440V, 50 Hz
9A 20A MX 09 1 NC CS94024 3310 10
ML 4/6/12 - 110V, 240V and 415V, 50 Hz
12A 20A MX 12 1 NO CS94025 3720 10
12A 20A MX 12 1 NC CS94026 3720 10
Lauritz Knudsen, 15.08.2026 05PDF page 13 4 Pole Power Contactors [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
4 Pole Power Contactors [8536]
4 Pole Power Contactors - Type MCX Notes for MCX:
1) # Add-on blocks can be ordered separately.
Features 2) For ordering MCX add-on aux contact blocks, please refer page No.8
› Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 3) For ordering MCX surge suppressor and MIL kit, please refer page No.9
4) For Ordering Suffix, please refer page No.10
› Range from 18A - 900A
5) Standard Coil Voltage: MCX - 220V, 240V and 415V 50Hz
› Wide operating band up to 130A AC-1 6) Mounting of side add-on aux. contact block is not recommended for
› Power contacts configuration - 4 NO mechanically interlocked MCX 11/12/13 contactors
7) MCX 01-04 and MCX 11-13 available in 48V DC coil. Contact nearest branch
for more details.
To avoid coil failure due to neutral floating, it is recommended to use 415V coil
MCX 22 MCX 34 MCX 47 AST System Components [9032]
AC-1 M.R.P. Std.
Aux
Size Rating
(A)
Type
Contacts
Cat. No. (`)
Per Unit
Pkg.
(Nos.)
Automatic Transfer Controllers (ATC)
18 MCX 01 # CS97009 2220 10
25 MCX 02 # CS97010 2290 10 For AuXC 2000/2100 programming
Fr 1 videos and more details please scan
32 MCX 03 # CS97011 2540 10 the QR code or click here
40 MCX 04 # CS97012 4230 10
55 MCX 11 # CS97013 6030 1 AuXC-2000 Controller
Fr 2 63 MCX 12 # CS97014 9960 1 M.R.P. (`) Std. Pkg.
Type Cat. No.
80 MCX 13 # CS97015 13410 1 Per Unit (Nos.)
105 MCX 22 # CS97017 20420 1 AuXC-2000 Controller ATC2000OOOO 52600 1
Fr 3 AuXC-2100 Controller**
130 MCX 23 # CS97018 21560 1 ATC2100OOOO 104800 1
with Optional RS485
160 MCX 32 2 NO + 2 NC CS97020 40530 1 RS485 Module for
ETACONRS485 20900 1
Fr 4 200 MCX 33 2 NO + 2 NC CS97021 43520 1 AuXC-2100 Controller**
255 MCX 34 2 NO + 2 NC CS97022 54260 1 Can be used along with ACB, Motorised MCCBs, MCX contactors & Motorised
Changeover switches
325 MCX 41 2 NO + 2 NC CS97023 85680 1 **Note: RS485 expansion module needs to be ordered with AuXC-2100 for communication
360 MCX 42 2 NO + 2 NC CS97024 93280 1
400 MCX 43 2 NO + 2 NC CS97025 112980 1
Fr 5 560 MCX 44 2 NO + 2 NC CS97026 153480 1 Control Relays (Auxiliary Contactors) [8536]
600 MCX 45 2 NO + 2 NC CS97027 162240 1
700 MCX 46 2 NO + 2 NC CS97028 182060 1 Type MX0 AC
900 MCX 47 2 NO + 2 NC CS94291 294300 1
Features
2 NO + 2 NC Power Contactor - Type MCX › Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1
Features › Available with AC or DC control in same dimension
› Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 › Inbuilt Surge Suppressor in MX DC
MX0 22E
› Range from 18A - 40A
› Power contacts configuration - 2 NO + 2 NC Rated
Description Cat. No.
M.R.P. (`) Std. Pkg.
Current Per Unit (Nos.)
AC-1 M.R.P. (`) Std. For AC control std. Coil Voltage - 24, 110, 240, 415V, 50Hz
Type Power
Size Rating Cat. No. Per Unit Pkg.
Contacts 2260 10
(A) (Nos.) MX0 40E (4 NO) CS94018
18 MCX 01-22 2 NO + 2 NC CS91107 2220 10 MX0 31E (3 NO + 1 NC) CS94019 2260 10
AC-15
25 MCX 02-22 2 NO + 2 NC CS91108 2290 10 4A MX0 22E (2 NO + 2 NC) CS94020 2260 10
Fr 1 at 415V
32 MCX 03-22 2 NO + 2 NC CS91109 2540 10 MX0 13E (1 NO + 3 NC) CS94041 2260 10
40 MCX 04-22 2 NO + 2 NC CS91110 4230 10 MX0 04E (4 NC) CS94042 2260 10
Block diagrams Type MX0 DC
Single supply and 2 separate loads 2 separate supplies and 2 separate loads Rated M.R.P. (`) Std. Pkg.
Description Cat. No.
Current Per Unit (Nos.)
For DC control std. Coil Voltage - 24, 110, 220V
MX0 40E (4 NO) CS94027 2790 10
MX0 31E (3 NO + 1 NC) CS94028 2790 10
AC-15
4A MX0 22E (2 NO + 2 NC) CS94029 2790 10
at 415V
MX0 13E (1 NO + 3 NC) CS94043 2790 10
MX0 04E (4 NC) CS94044 2790 10
Notes: 1) For Ordering Suffix, please refer page No.10
2) 5 NC & above combinations are not recommended for MX0 DC Control Contactors
! MCX 2NO + 2NC contactors are not suitable for a reversing starter or for controlling a 3) 1 NO + 3 NC, 4 NC add-on block combinations are not recommended for MX0 DC
single load from 2 separate supplies. Control Contactors.
Lauritz Knudsen, 15.08.2026 06PDF page 14 Type MO0 AC Type
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Type MO0 AC Type MO0 DC
Features Features
› Same add-on aux. contact block in MO0 as of › Same add-on aux. contact block in MO0 as of
MO power contactors MO power contactors
› Common coil for 50 & 60Hz application › Inbuilt Surge Suppressor in MO0 DC
MO0 AC MO0 DC
Rated M.R.P. (`) Std. Pkg. Rated Description M.R.P. (`) Std. Pkg.
Description Cat. No. Cat. No.
Current Per Unit (Nos.) Current Per Unit (Nos.)
For AC control std. Coil Voltage - 24, 110, 240, 415V, 50Hz For DC control std. Coil Voltage - 24, 48, 110, 220
MO0 40E (4NO) CS91623 1500 10 MO0 40E (4NO) CS90045 2950 10
AC-15 AC-15
4A MO0 31E (3NO + 1NC) CS91624 1500 10 4A MO0 31E (3NO + 1NC) CS90046 2950 10
at 415V MO0 22E (2NO + 2NC) CS91625 1500 10 at 415 V MO0 22E (2NO + 2NC) CS90047 2950 10
Note: 6NC & above combination is not recommended for MO0 AC Note: 5NC & above combination is not recommended for MO0 DC
For ordering add-on contact blocks of MX0, MO0, please refer page no.8 For ordering add-on contact blocks of MX0, MO0, please refer page no.8
Capacitor Duty Contactors [8536]
Capacitor Duty Contactors - Type MO C Features
› Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1
› MO C Range available from 3 -100 kVAr, AC-6b
› Delatching type early make contacts
› Separate termination for damping resistors
› Encapsulated damping resistor assembly
› Common coil for 50 & 60Hz application
MO C50 MO C100 › Low pick-up VA consumption
kVAr Rating Built-in Std. › Standard accessories throughout the range in line with MO contactor
Type M.R.P. (`) Pkg. › Suitable for Lug as well as Lugless termination
Size @ 440V, Auxiliary Cat. No.
Per Unit (Nos.)
3Ph, 50Hz Contacts › RoHS compliant
3 MO C3 1NO CS96146 3480 1
5 MO C5 1NO CS96127 3700 1
For Power Quality Solutions,
8.5 MO C8.5 1NO CS96320 4800 1
please refer page No. 87-95
10 MO C10 1NO CS96156 4910 1
Fr 1 12.5 MO C12.5 1NO CS96321 5180 1
15 MO C15 1NO CS90019 6980 1
20 MO C20 1NO CS90021 7770 1
Note:
25 MO C25 1NO CS96322 8370 1 1) For ordering add-on aux. contact block, please refer page No.8
30 MO C30$ 1NO CS96148 13330 1 2) For ordering suffix, please refer page No.10
40 MO C40 1NO CS96147 22120 1 3) For ordering spare coils, please refer page No.11
50 MO C50 1NO CS96324 24830 1 4) Standard coil voltage : 240V, 50/60 Hz
Fr 2
5) For ordering MO C surge suppressor, please refer page No.9
60 MO C60$ 1NO CS96149 25820 1
75 MO C75 1NO CS96150 30870 1 If using 16 sq mm cable use of spreader link kit is mandatory
Fr 3 85 MO C85 1NO CS96157 33220 1 For ordering spreader link kit, Please refer page No.9
100 MO C100$ 1NO CS96158 33870 1 Spreader link along with phase barrier included in packing
Definite Purpose Contactors [8536]
Two Pole Contactors - Type MU-2P
Features
› Wide band potted coil
› Neutral isolation
MU 16-2P
Std.
AC3 Rating (A) Type M.R.P. (`)
Cat. No. Pkg.
Per Unit (Nos.)
16A MU16-2P CS90117 1600 10
25A MU25-2P CS90118 1950 10
40A MU40-2P CS90119 2500 10
Note:
1) Coil voltages available for MU-2P are 220V, 240V, wide band coil 160-220V
2) Ordering suffix for wide band coil of MU-2P is NOOO
3) For ordering add-on aux. contact block, please refer page No.8
Lauritz Knudsen, 15.08.2026 07PDF page 15 Accessories - Add-on Auxiliary Contact Blocks [8538]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Accessories - Add-on Auxiliary Contact Blocks [8538]
MNX MNX MO MO MDX MCX MCX
ML MX MX0 MO0 MO C MU-2P
9-80 95-650 9-110 140-300 9-115 01-23 32-47
Front add-on possible Yes No Yes No No Yes Yes Yes No Yes Yes No Yes
Side add-on possible Yes Yes Yes Yes Yes No Yes Yes Yes No No Yes No
Note: 1) Mounting of side add-on aux. contact block is not recommended for mechanically interlocked MCX 11/12/13 contactors
2) Accessories are common for MNX 2P & MNX 3P contactors
Front Mounting
Add-on aux. Contact Block
MNX / MCX MO / MO0 MDX Front MX Front MU-2P
Front Add-on Front Add-on Add-on Add-on Front Add-on
aux. contact Block aux. contact Block aux. contact Block aux. contact Block aux. contact Block
Suitable for
Front MX
Mounting MNX 9-80 / M.R.P. (`) MO 9-110 / M.R.P. (`) MDX# M.R.P. (`)
(6,9,12)
M.R.P. (`)
MU-2P
M.R.P. (`)
MCX 01-23 Per Unit MO0 Per Unit 9-115 Per Unit /MX0 Per Unit Per Unit
4 NO CS94112^ 1195 CS94594^ 1590 CS94033^ 1120 - -
3 NO + 1 NC CS94113^ 1195 CS94595^ 1590 CS94034^ 1120 - -
2 NO + 2 NC CS94114^ 1195 CS94596^ 1590 CS96569~ 2600 CS94035^ 1120 - -
1 NO + 3 NC CS94115^ 1195 CS94597^ 1590 CS90906~ 2600 CS94036^ 1120 - -
4 NC CS94116^ 1195 CS94598^ 1590 CS94037^ 1120 - -
2 NO CS94117^ 785 CS94591^^ 915 CS94030^ 725 CS90692^ 940
1 NO + 1 NC CS94118^ 785 CS94592^^ 915 CS96568~ 1520 CS94031^ 725 CS90693^ 940
2 NC CS94119^ 785 CS94593^^ 915 CS94032^ 725 CS90694^ 940
1 NO CS94120^ 400 CS94585^^ 535 CS90695^ 480
CS96586~ 850
1 NC CS94121^ 400 CS94586^^ 535 CS90696^ 480
#
For MDX Side add-on and top add-on can not be mounted together
*MDX add-on available till stock last
Side Mounting
Add-on aux. Contact Block MNX/MCX MO/MO C
Side Add-on aux. contact Block Left Add-on aux. contact Block
Suitable for
Side
Mounting Aux MNX 9-40 / M.R.P. (`) MCX M.R.P. (`) MNX 50-80 / M.R.P. (`) MO 9-110/ M.R.P. (`)
Contact MCX 01-04 Per Unit 11-13 Per Unit MCX 22-23 Per Unit MO C 3-100 Per Unit
First left 1 NO + 1 NC CS94220^ 1265 CS94201^ 1370 CS94201^ 1370 CS94580^ 1475
First Right 1 NO + 1 NC CS94221^ 1265 CS94202^ 1370 CS94202^ 1370 CS94581^ 1475
Second Left 1 NO + 1 NC CS94203^ 1370 CS94582^ 1475
Second right 1 NO + 1 NC CS94204^ 1370 CS94583^ 1475
Note: Mounting of side add-on aux. contact block is not recommended for mechanically interlocked MCX 11/12/13 contactors
For MO 9-18, only First left and Second left side add-on is allowed.
Side Mounting
Add-on aux. Contact Block
Suitable for
Side
Mounting Aux MNX 95-650/ M.R.P. (`) MO M.R.P. (`) MDX# M.R.P. (`)
Contact MCX 32-47 Per Unit 140-300 Per Unit 9-115 Per Unit
First left 1 NO + 1 NC CS94205^ 1555 CS95033^ 1815
ST94985^ 3110
First Right 1 NO + 1 NC CS94206^ 1555 CS95034^ 1815
Second Left 1 NO + 1 NC CS94207^ 1555 CS95035^ 1815 MDX
Side Add-on aux.
Second right 1 NO + 1 NC CS94208^ 1555 CS95036^ 1815 contact Block
#
For MDX Side add-on and top add-on can not be mounted together
- Standard Packing is 1 ^Standard Packing is 10 ^^Standard Packing is 20
* MDX add-on available till stock last
Lauritz Knudsen, 15.08.2026 08PDF page 16 Accessories - Add-on Auxiliary Contact Blocks [8538]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Accessories - Add-on Auxiliary Contact Blocks [8538]
Side Mounting Add-on aux. Contact Block -ML
ML Add-on aux. contact Block
Suitable for
Side M.R.P.
Mounting M.R.P. (`)
Aux Contact ML 4/6 (`) ML 12
Per Unit
Per Unit
Left 1 NO + 1 NC SS91494^ 1920
Right 1 NO + 1 NC SS91474^ 1920
Note: Ordering Suffix for Add-on aux. contact blocks : OOOO
Accessories - Surge Suppressors [8538]
Std.
For MX, MNX, MCX, MO & MO C For Contactor Cat. No.
M.R.P. (`)
Pkg.
Per Unit
(Nos.)
MX 06 to MX 12 / MX 0 AC (S1) CS94039* 1050 10
MNX 9 - 40 / MCX 01 - 04 (S1) CS94166* 1070 10
MNX 50 - 80 / MCX 11 - 23 (S3) CS94163* 1195 10
MNX 95 - 250 / MCX 32 - 34 (S4) CS94164# 3910 10
MNX 300 - 400 / MCX 41 - 44 (S6) CS94165# 5280 10
MX - S1
MO Frame 0/1, MO C Frame 1, MO0 Control CS91706^ 1070 10
Ordering Suffix * 110-240V : BOOO, 415V : DOOO
#
110V : AOOO, 220-240V : BOOO, 360-525V : DOOO MO/MO C - Frame 2 CS91707^ 1195 10
^ 110V : AOOO, 220-320V : BOOO, 360-415V : DOOO MO/MO C - Frame 3 CS91708^ 3910 10
MDX 9-115, MNX 550-650, MCX 45-47, MX DC, MX0 DC & MO0 DC MO Frame - 4/5 CS91854^ 5280 10
have built in surge suppressor
Accessories - Mechanical Interlock Kits & Spreader Link Kit [8538]
Mechanical Interlock Kit for MX, MO, MDX, MO / MO C Spreader Link Kit
MNX & MCX
MCX M3 (MCX 22)
Std. Std.
M.R.P. (`) For Contactor M.R.P. (`)
For Contactor Cat. No. Pkg. Cat. No. Pkg.
Per Unit Per Unit
(Nos.) (Nos.)
MX 06 to MX 12 / MX 0 CS94038 1010 10 MO 9 - 45 / MOC 3 - 30 CS94274 950 10
MO 9 - 110* CS94584 1795 10 MO 50 - 70 / MOC 40 - 60 CS94093 1505 10
MDX 9 - 38 CS96572 1990 1
MO 80 - 110 / MOC 75 - 100 CS94094 2170 1
MDX 50 - 115 CS96573 6040 1
MO 140 - 225 CS91057 6110 1
MNX 9 - 40 CS94126 820 10
MNX 50 - 80 CS94197 5770 1 MO 250 - 300 CS90940 9500 1
MNX 95 - 140 CS94198 8990 1 Note:
MNX 185 - 250 CS94199 10220 1 1) If using 16 sq mm cable for MO 45/ MO C25 use of spreader link is mandatory
MNX 300 - 650 CS94200 11580 1 2) Spreader Link Kit consists of six terminals along with phase barrier
MCX 01 - 04 CS94126 820 10 (Phase barrier not applicable for MO 250-300)
3) In MO C 30, MO C 60 & MO C 100 spreader link is included in packing
MCX 11 - 13 ST50540 1625 10
4) Ordering Suffix: OOOO
MCX 22 - 23 CS93095 7620 1
! 5) Insert spreader link in top slot only
MCX 32 - 34 SS94992 7870 1
MCX 41 - 47 CS94301 12980 1
*MDX Mechanical interlock kit Available till stock last
Note:
1) Ordering Suffix for Mechanical Interlock Kits : OOOO
2) *MO MIL Kit contains inbuilt 2 NC Contacts
3) Mounting of side add-on aux. contact block is not recommended for mechanically interlocked MCX 11/12/13 contactors
4) MIL kit for MNX 50-80 comes with 2 left & 2 right side add-on aux. contact blocks i.e. 4 NO + 4 NC
Lauritz Knudsen, 15.08.2026 09
5) MIL kit for MCX 22/23 comes with 2 left & 2 right side add-on aux. contact blocks i.e. 4 NO + 4 NCPDF page 17 Accessories - Connecting Links [8538]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Accessories - Connecting Links [8538]
DOL Starter - Link Reversing DOL Starter - Link
Contactor Reversing Paralleling Contactor
MMS Link Starter Link MMS Link
M.R.P. Std. M.R.P. Std.
Suitable For Cat. No. (`) Pkg. Suitable For Cat. No. (`) Pkg.
Per Unit (Nos.) Per Unit (Nos.)
MOG H1/S1 with MO 9-18 CS90396 # 785 10 MOG H1/S1 with MO 9-18 CS90548 # 1970 10
MOG H1/S1 with MO 25-45 CS90391 # 785 10 MOG H1/S1 with MO 25-45 CS90546 # 1970 10
Star Delta Starter - Link Example of Star Delta Starter
Connection with Link
MMS
MMS
MPCB
Reversing / Paralleling Contactor Shorting
star delta Link Link MMS Link Link MMS
MPCB
LINK
M.R.P. Std.
Suitable For Cat. No. (`) Pkg.
Per Unit (Nos.)
MOG H1/S1 with MO 9-18 CS90549 # 2390 10
MOG H1/S1 with MO 25-45 CS90547 # 2390 10
#
Ordering Suffix OOOO
Ordering Suffix for Standard Coil Voltages
Ordering Suffix for Standard Coil Voltages Ordering suffix for Electronic coil Contactor
AC Control DC Control* AC / DC control
Voltage (V) Suffix Voltage (V) Suffix Voltage (V) Suffix Contactor
24 GOOO 24 4OOO 20-48 JOOO MDX 50-115
110 AOOO 48 5OOO 60-110 AOOO MDX 50-115
220 KOOO 110 1OOO 110-240 BOOO MDX 50-115 & MO 140-300
240 BOOO 220 2OOO 240-415 DOOO MO 140-300
415 DOOO Note:
440 POOO 1) * For MX DC, MDX 9-38, MX0 DC, MO0 DC
2) For other coil voltages please contact nearest branch office
Lauritz Knudsen, 15.08.2026 10PDF page 18 Spares [8538]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Spares [8538]
Spare Contact Kit and Spare Coil Spare Contact Kit and Spare Coil
MNX Spare Coils MCX Spare Kits
Spare Contact kit Spare Coil
ML Spare Kits
Type Cat. No. M.R.P. (`) Cat. No. M.R.P. (`)
Per Unit Per Unit
MO 9 (1 NO ) CS94843 ^ 1220
MO 12 (1 NO ) CS94844^ 1580 CS94841^ 1030
MO 18 (1 NO) CS94845^ 1740
ML Spare Coils
MO 9 CS96380^~ 1220
Spare Contact kit Spare Coil MO 12 CS96381^~ 1580
M.R.P. (`) M.R.P. (`) MO 18 CS96382^~ 1740
Type Cat. No. Cat. No.
Per Unit Per Unit MO 25 CS96383^~ 2020 CS96317^ 1265
ML 1.5 5575 SS90873 ^ 1840 MO 32 CS96384^~ 4565
SS95305^
MO 40 CS96385^~ 7705
ML 2 SS95307^ 10200
SS90545 ^ 3410 MO 45 CS96386^~ 7800
ML 3 SS95309^ 18020
MO 50 CS96387^~ 8175
ML 4 SS95311^ 26710
SS91258 ~ MO 60 CS96388^~ 10590 CS96318^ 3900
MO Contactors
6665
ML 6 SS95313^ 49415
MO 70 CS96389^~ 11755
ML 10 SS95315~ 96245 MO 80 CS96390^~ 16175
SS91011 ~ 14220
ML 12 SS95317~ 103715 MO 95 CS96391^~ 20400 CS96319^ 6740
MR - - CS94102 ^ 1400 MO 110 CS96392^~ 29805
MU16-2P CS90217^ 540 MO 140 CS90357~ 35490
MU25-2P CS90218^ 715 CS90793 ^ 620 MO 185 CS90358~ 42580 CS90356~ 15970
MU40-2P CS90219^ 1020 MO 225 CS90359~ 48755
MO 0 AC - - CS94841 ^ 1030 MO 250 CS94444~ 58615
CS94442~ 23295
* MR Coils available till stock last MO 300 CS94443~ 66155
Note: MO 140 (electronic coil) CS90357~ 35490
1) Coil voltages available for MU-2P are 220V, 240V, wide band coil 160-220V MO 185 (electronic coil) CS90358~ 42580 CS90855~ 28930
2) Ordering suffix for wide band coil of MU-2P is NOOO MO 225 (electronic coil) CS90359~ 48755
MO 250 (electronic coil) CS94444~ 58615
CS90738~ 29060
MO 300 (electronic coil) CS94443~ 66155
MO C Spare Coils MNX 9 CS94123^ 975
M.R.P. (`) MNX 12 CS94124^ 1265
Type Cat. No.
Per Unit MNX 18 CS94125^ 1440
MO C3 - 30 CS96317^ 1265 MNX 22 CS94269^ 1600 CS94105 925
MNX 25 CS94127^ 2080 ^
MO C40 - 60 CS96318^ 3900
MNX 32 CS94128^ 4030
MO C75 - 100 CS96319^ 6740
MNX 40 CS94147^ 6560
MNX 50 CS94150^ 7230
MNX 70 CS94151^ 10890 CS94192^ 3700
Front housing & Moving bridge kit and
MNX Contactors
MNX 80 CS94152^ 14840
Combination coil with timer for MNX 95 CS94153~ 20855
CS94154~ 30195 ~
ML contactor MNX 110
MNX 140 CS94155~ 36615
CS94196 6340
MNX 185 CS94156~ 40805
~
MNX 225 CS94157~ 47185 CS94194 14480
MNX 250 CS90310~ 56170
MNX 300 CS90283~ 62795 ~
CS94195 21460
MNX 400 CS94161~ 94780
Front housing and moving bridge kit MNX 550 CS94162~ 127350 ~
CS94193 45355
MNX 650 CS96336~ 198840
Type M.R.P. (`)
Cat. No.
Per Unit MCX 01-04 - - CS94105 ^ 925
MCX 11 CS94077^ 3270
ML 1.5 ST28734~ 1765
MCX 12 CS94078^ 7170 CS94009 ^ 1110
ML 2/ ML 3 ST23866~ 2410
MCX 13 CS90307^ 11115
ML 4/ ML 6 ST28735~ 4370 MCX 22 CS94331~ 13745
ST91291* ~ 3110
Combination coil with timer MCX 23 CS90078~ 15465
M.R.P. (`) MCX 32 CS94082^ 26425
MCX Contactors
Type Cat. No. ~
6340
Per Unit MCX 33 CS94083^ 31060 CS94196
ML 2 SS90650 ~
7530 MCX 34 CS94084^ 36965
MCX 41 CS94295~ 53585
Note:
MCX 42 CS94296~ 61300 ~
1) Ordering Suffix for Spare Contact kit - OOOO CS94195 21460
2) For Spare Coil Ordering Suffix refer page No. 10 MCX 43 CS94297~ 73555
MCX 44 CS94298~ 103955
~ Standard Packing is 1 MCX 45 CS94299~ 102040
^~ Standard Packing is 5 CS94300~ 112960 CS94193
~
45355
MCX 46
^ Standard Packing is 10
MCX 47 CS90308~ 179215
~~ Standard Packing is 50
* Ordering Suffix for 240V AC - FOOO, 415V AC - ROOO
Lauritz Knudsen, 15.08.2026 11No matching text found. Try a shorter model code or check the original PDF, including illustrated pages.
BEFORE YOU SPECIFY
Make an informed choice.
LET’S GET THE SPECIFICATION RIGHT
From your shortlist
to a clear quote.
Share the catalog number, rating and quantity. We’ll confirm the current price, availability and lead time.