LAURITZ KNUDSEN / ELECTRICAL & AUTOMATION
Industrial switchgear & automation
A connected portfolio for motor control, power distribution and industrial automation.

EXPLORE THE COLLECTION
Built around your application.

Contactors, accessories & spares
Switching components for motor and control circuits.

Motor protection relays
Protection and monitoring options for motor circuits.

Manual motor starters
Manual switching and protection devices for motor applications.
Industrial motor starters
Motor starting assemblies and coordination references.

Automatic transfer switches
Automatic supply transfer solutions for planned source changeover.
Switch disconnectors & fuses
Power switching, isolation and fuse protection.

Moulded case circuit breakers
MCCB ranges for distribution and motor back-up protection.

Sub-main distribution boards
SMDB enclosures and matching accessories for power distribution.

Air circuit breakers
ACBs, releases and accessories for low-voltage distribution.

Power quality & correction
Components and systems for power-factor correction and harmonic management.

Numerical protection relays
Protection relay products for specified power-system schemes.

Energy meters & gateways
Measurement and connectivity for electrical monitoring.

AC drives
Variable-frequency drives and matching accessories for motor-control projects.

Digital soft starters
Electronic motor starting with configurable control and optional modules.

PLCs & HMI
Control and operator-interface hardware for industrial automation.
EXORA final distribution
Explore MCBs, RCCBs, RCBOs and final distribution boards.
MANUFACTURER REFERENCE / August 2026
Details, down to
the catalog number.
Browse the supplied specification pages. Published MRP is a dated manufacturer reference; request a current Nova quote and confirm the tax basis and pack size.
ESP Lauritz Knudsen Price List (1).pdf ↗ · PDF pages 1–156
156 catalog pages
PDF page 1 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 2 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 3 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 4 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 5 Efficient DC Solutions
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Efficient DC Solutions
up to 1500V DC
Applications:
› Battery Energy Storage System
› Central Inverter Application MCCB
› Range from 16A to 800A
› EV System › DC Operational Voltages of 1500V,
1000V, 750V, 500V & 250V
› Ambient Temperature Compensated
DC Releases
› Internal Accessory Compatibility for all
DC Applications
› Service Breaking Capacity Ics upto 50kA
ACB - SD
› Disconnector versions up to 6300A*
› DC Voltage ratings 1500V#, 1000V,
750V, 500V & 250V
› Service Breaking Capacity Ics upto 100kA
6300A in two pole series connection for voltage up to 500V DC
*
Upcoming version
#
SWITCH DISCONNECTOR
› Range: 125A to 630A
› Voltage: 1000/1500V DC
MCB
› Conforms to IEC 60947-2
› Current rating upto 63A
› Available in SP/DP and FP versions
› Voltage rating available from 130V DC to 1000V DC
gPV Fuses
› Conforms to IEC 60269-6
› Range: 2A to 32A, 1000V, DC
› Range: 2A to 32A, 1500V, DC
› High breaking capacity: 20kAPDF page 6 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 7 Contents
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Contents Switching & Control Contactors 03 Accessories 08 Spares 11 Motor Protection Solutions Thermal Overload Relays 12 Electronic Motor Protection Relays 14 iMMR - Intelligent Motor Management Relay 19 Manual Motor Starters 21 Starters Motor Starters 23 Powergear Integrated ATS 27 Enclosed Automatic Transfer Switch 28 On Load Changeover Switch-Disconnectors 29 CZ Bypass Switch & CZ Switch Disconnectors 30 gPV Fuses 33 FN Switch Disconnector, Switch Disconnector Fuse & HRC Fuses 34 Moulded Case Circuit Breakers 39 Sub - Main Distribution Boards 68 Air Circuit Breakers 70 Energy Management Power Quality Solutions - Components 88 AHF & ASVG 93 Protection Relays 98 Metering Devices 103 Smartcomm Digital Architecture 104 Digital Panel Meters 108 SmartComm Edge Gateways & Thermal Monitoring Solutions 113 Automation Solution AC Drives 115 Digital Soft Starters 120 Programmable Logic Controllers (PLC) & Human Machine Interface 123 Final Distribution Products 126 Discontinued Products/Suggested Alternate Products 144 Note: [Black colour : HSN code] Current GST 18%, subject to changes as per Govt. notification
PDF page 8 Please contact the nearest branch office for
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Please contact the nearest branch office for Prices of the following products : › Final Distribution Products - 6kA MCBs › Wires, Cables and Flat Cables › Busbar Trunking Systems › Rotary Switches › Modular Remote Control Units & Indicating Units › Timing Devices & Supply Monitors › Cable Ducts & Load Break Switches › Modular Switches and Sockets › Medium Voltage AIS upto 36kV › Agricultural Electrical Products Note: Product photographs shown, are for representative purposes only.
PDF page 9 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 10 Contactors
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Contactors
Power Contactors Control Relays Capacitor Duty
2 Pole 3 Pole 4 Pole (Auxiliary Contactors) Contactors
› MNX › MO › MCX › MX0 (Mini) AC/DC › MO C
› MNX
› MU-2P › MO0 AC/DC
› MI
› MX Power
› ML
› MDX (DC Control/Electronic coil Control)
MI Contactors
6-150A, AC-3 Rating
Optimum solution
for your applications
Understanding customer requirements, we make sure that our range of contactors caters to their evolving needs. Considering the
changing expectations of customers and a need for an optimum and reliable solution, we introduce MI range of contactors for
applications upto 150 A AC3 rating.
M.R.P. (`)
Type Cat. No.
Features Per Unit
› Finger proof terminals upto 40A MI 6 (With 1 NO aux contact) CS90401
› Can be used with existing MN Range of thermal overload relays MI 9 (With 1 NO aux contact) CS90402
› Top mounting add-on blocks possible upto 80A MI 12 (With 1 NO aux contact) CS90403
› Spares available for entire range MI 18 (With 1 NO aux contact) CS90404
› Optimised for AC1/AC3 applications MI 22 (With 1 NO aux contact) CS90405
MI 25 (With 1 NO aux contact) CS90406 Price
Applications on
MI 25 CS92912#
› Street lighting MI 32 CS90407
Request*
› VFD, Soft Starters applications MI 40 CS90408
› UPS MI 45 CS90704
› Solar and Wind inverters MI 50 CS90705
› Resistive loads MI 70 CS90706
› Battery charging MI 80 CS90707
› Motor Starters MI 95 CS90724
* For accessories and more details please contact nearest branch. MI 120 CS90725
MI 150 CS90726
Notes:
1) Standard coil voltage: 110V, 220V, 240V and 415V, 50Hz
2) For ordering Suffix, please refer page No. 10
3) # For 2 no. of 4 sq. mm wires with lugs in single terminal
4) MI6-25 Available with 1NC on Request
Lauritz Knudsen, 15.08.2026 03PDF page 11 3 Pole Power Contactors [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
3 Pole Power Contactors [8536]
3 Pole Power Contactors - Type MNX 3 Pole Power Contactors - Type MO
Features Features
› Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 › Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1
› Range from 9A – 650A AC-3 › Range from 9A - 300A AC-3
› Click fit type construction up to 40A › Range 140A-300A available with conventional / universal AC/DC
› Coil on top design in 95A and above electronic coil version
› Spares available for entire range › Common coil for 50 & 60Hz application
› Low pick-up VA consumption
› Standardized accessories for 9A-110A and 140A-300A range
› Compact dimensions saving panel space
› Suitable for Lug as well as Lugless termination
› RoHS compliant
MNX 22 MNX 40 MNX 80
MO 18 MO 45 MO 70 MO 110 MO 140 MO 250
MNX 140 MNX 250 MNX 650
AC 4 AC 3e AC 1 M.R.P. Std.
Type Aux.
AC3 AC1 M.R.P. Std. Size Rating Rating Rating Cat. No. (`) Pkg.
Aux. Contacts
Size Rating Rating Type Cat. No. (`) Pkg. (A) (A) (A) Per Unit (Nos.)
Contacts
(A) (A) Per Unit (Nos.) 1 NO CS94833 2970 10
9 9 30 MO 9
1 NO CS94106 1550 20 1NC CS92918 2970 10
9 25 MNX 9
1 NC CS94107 1550 20 1 NO CS94834 3320 10
Fr 0 12 12 32 MO 12
1 NO CS94108 1800 20 1 NC CS92919 3320 10
12 30 MNX 12
1 NC CS94109 1800 20 1 NO CS94835 4010 10
Fr 1 18 18 32 MO 18
1 NO CS94100 2140 20 1 NC CS92920 4010 10
18 30 MNX 18
1 NC CS94101 2140 20 25 25 45 MO 25 # CS94567 5240 10
MNX 22 1 NO CS94980 2670 20 32 32 50 MO 32 # CS94568 9760 10
22 32
1 NC CS94981 2670 20 Fr 1 40 40 50 MO 40 # CS94569 14190 10
25 45 MNX 25 # CS94110 2730 20 45 45 50 MO 45 # CS94570 20590 10
Fr 2 32 55 MNX 32 # CS94111 5320 20 50 50 100 MO 50 # CS94572 20900 1
40 55 MNX 40 # CS94190 7880 20 Fr 2 60 60 100 MO 60 # CS94573 28560 1
50 85 MNX 50 # CS97075 11470 1 70 70 100 MO 70 # CS94574 29100 1
Fr 3 70 100 MNX 70 # CS97076 16160 1 80 80 125 MO 80 # CS94576 35890 1
80 100 MNX 80 # CS97077 20170 1 Fr 3 95 95 125 MO 95 # CS94577 45510 1
95 160 MNX 95 2 NO + 2 NC CS94136 33910 1 110 110 140 MO 110 # CS94578 55350 1
Fr 4 110 160 MNX 110 2 NO + 2 NC CS94137 41370 1 140 140 250 MO 140 2 NO + 2 NC CS95000 71450 1
140 160 MNX 140 2 NO + 2 NC CS94138 52760 1 Fr 4 185 185 275 MO 185 2 NO + 2 NC CS95001 90380 1
185 250 MNX 185 2 NO + 2 NC CS94139 64390 1 225 225 275 MO 225 2 NO + 2 NC CS95002 97180 1
Fr 5 225 300 MNX 225 2 NO + 2 NC CS94140 71760 1 140 140 250 MO 140 2 NO + 2 NC CS95042 93520 1
250 300 MNX 250 2 NO + 2 NC CS94141 80210 1 Fr 4* 185 185 275 MO 185 2 NO + 2 NC CS95047 125770 1
300 400 MNX 300 2 NO + 2 NC CS90280 96890 1 225 225 275 MO 225 2 NO + 2 NC CS95052 129110 1
400 425 MNX 400 2 NO + 2 NC CS94144 140960 1 250 250 400 MO 250 2 NO + 2 NC CS94441 118090 1
Fr 6 Fr 5
550 650 MNX 550 2 NO + 2 NC CS94145 207040 1 300 300 500 MO 300 2 NO + 2 NC CS94440 141720 1
650 800 MNX 650 2 NO + 2 NC CS96327 309720 1 250 250 400 MO 250 2 NO + 2 NC CS94456 152580 1
Fr 5*
Notes: 300 300 500 MO 300 2 NO + 2 NC CS94464 175700 1
1) # Add-on blocks can be ordered separately
2) For ordering MNX/MO add-on aux contact blocks, please refer page No.8
3) For ordering MNX/MO surge suppressor and MNX/MO MIL kit, please
refer page No.9
4) For ordering Suffix, please refer page No.10
5) Standard coil voltage: MNX/MO - 110V, 220V, 240V and 415V, 50Hz.
If using 16 sq mm cable for MO 45 use of spreader link kit is mandatory
AC-15 AC-3/3e
For ordering spreader link kit for MO 45, Please refer page No.9
* Universal AC/DC electronic coil version
AC-8a/8b
AC-4
AC-6a
AC-5a/5b
AC-6b AC-1
Lauritz Knudsen, 15.08.2026 04PDF page 12 2 Pole Power Contactors [8536] 3 Pole
Extracted reference text; use the original PDF to check column alignment, variants and price units.
2 Pole Power Contactors [8536] 3 Pole Power Contactors [8536]
2 Pole Power Contactors - Type MNX 3 Pole Power Contactors - Type MDX
Features Features
› Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 › Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
› Range from 9A - 650A AC-3 › Range from 9 - 115A AC-3
› DC ratings available › Built in surge suppressor for MDX 9 - 115
› Click fit type construction up to 40A
› Coil on top design in 95A and above
› Common spares and accessories as MNX 3P
AC3 AC1 M.R.P. Std.
Type Aux.
Size Rating Rating Cat. No. (`) Pkg.
Contacts
(A) (A) Per Unit (Nos.) MDX 25 MDX 38 MDX 115
9 25 MNX 9-2P 1 NO CS90232 1320 10 AC3 AC1 M.R.P. Std.
Type Aux.
12 30 MNX 12-2P 1 NO CS90234 1530 10 Size Rating Rating Cat. No. (`) Pkg.
Fr 1 Contacts
18 30 1820 10 (A) (A) Per Unit (Nos.)
MNX 18-2P 1 NO CS90236
22 32 MNX 22-2P 1 NO CS90238 2270 10 9 25 MDX 9 1 NO CS96564 4500 1
Fr 1 12 28 MDX 12 1 NO CS96565 5150 1
25 45 MNX 25-2P # CS90240 2320 10 (DC Control
Fr 2 32 55 MNX 32-2P # CS90241 4520 10 Coil) 18 32 MDX 18 1 NO CS96566 6140 1
40 55 MNX 40-2P # CS90242 6700 10 25 32 MDX 25 1 NO CS96567 13730 1
Fr 2 32 56 MDX 32 # CS96552 17500 1
50 85 MNX 50-2P # CS94061 10100 1 (DC Control
Fr 3 70 100 MNX 70-2P # CS94062 14230 1 Coil) 38 56 MDX 38 # CS96553 23220 1
80 100 MNX 80-2P # CS94063 17900 1 50 90 MDX 50 # CS91584 31610 1
95 160 MNX 95-2P # CS94064 28600 1 Fr 3 65 110 MDX 65 # CS91585 35790 1
(Electronic 80 125 MDX 80 # CS91586 44390 1
Fr 4 110 160 MNX 110-2P # CS94065 34900 1 Coil-AC/DC)
95 125 MDX 95 # CS91857 53630 1
140 160 MNX 140-2P # CS94066 44500 1
115 125 MDX 115 # CS91858 60270 1
185 250 MNX 185-2P 2 NO + 2 NC CS94978 55700 1
* MDX Available till stock lasts
Fr 5 225 300 MNX 225-2P 2 NO + 2 NC CS94979 62600 1
250 300 MNX 250-2P 2 NO + 2 NC CS90301 69900 1 Notes:
300 400 MNX 300-2P 2 NO + 2 NC CS90346 84500 1 1) # Add-on blocks can be ordered separately.
400 425 123900 1 2) For ordering MDX/MNX add-on aux contact blocks, please refer page No.8
MNX 400-2P 2 NO + 2 NC CS94069
Fr 6 3) For ordering MNX surge suppressor and MIL kit, please refer page No.9
550 650 MNX 550-2P 2 NO + 2 NC CS90243 182100 1
4) For ordering Suffix, please refer page No.10
650 800 MNX 650-2P 2 NO + 2 NC CS90578 272300 1 5) Standard coil voltage: MDX - 24V, 48V, 115V and 220V DC
6) Standard coil voltage: MNX 2P - 240V, 50Hz
7) For DC power ratings refer catalogue
8) For MDX side add-on and top add-on can not be mounted together
3 Pole Power Contactors [8536]
3 Pole Power Contactors - Type MX Mini 3 Pole Power Contactors - Type ML
Features Features
› Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 › Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
› AC/DC Contactor in 45mm width › Range from 25A- 300A AC-3
› Base as well as DIN Rail mounting facility › Robust and suitable for hostile applications
› Built-in Surge Suppressor in MX DC
MX 06 ML 1.5 ML 3
AC3 AC1 M.R.P. Std. AC3 AC1 M.R.P. Std.
Type Aux. Type Aux.
Rating Rating Cat. No. (`) Pkg. Size Rating Rating Cat. No. (`) Pkg.
Contact Contacts
(A) (A) Per Unit (Nos.) (A) (A) Per Unit (Nos.)
For AC control (Std. Coil Voltage - 24, 110, 240, 415V, 50Hz) Fr 1 25 25 ML 1.5 2 NO + 2 NC SS91851 10190 1
6A 20A MX 06 1 NO CS94012 2020 10 32 40 ML 2 2 NO + 2 NC SS90701 18930 1
Fr 2
6A 20A MX 06 1 NC CS94013 2020 10 40 45 ML 3 2 NO + 2 NC SS90721 27910 1
9A 20A MX 09 1 NO CS94014 2070 10 70 100 ML 4 2 NO + 2 NC SS90910 45600 1
Fr 3
9A 20A MX 09 1 NC CS94015 2070 10 110 125 ML 6 2 NO + 2 NC SS90921 72160 1
12A 20A MX 12 1 NO CS94016 2290 10 Fr 4 300 400 ML 12 2 NO + 2 NC SS91010 163350 1
12A 20A MX 12 1 NC CS94017 2290 10
Notes:
For DC control (Std. Coil Voltage - 24, 110, 220V) 1) For ordering MX add-on aux contact blocks, please refer page No.8
6A 20A MX 06 1 NO CS94021 3120 10 2) For ordering ML add-on aux contact blocks, please refer page No.9
6A 20A MX 06 1 NC CS94022 3120 10 3) For ordering MX surge suppressor and MIL kit, please refer page No.9
9A 20A MX 09 1 NO CS94023 3310 10 4) For Ordering Suffix, please refer page No.10
5) Standard Coil Voltage : ML 1.5/2/3 - 110V, 240V and 440V, 50 Hz
9A 20A MX 09 1 NC CS94024 3310 10
ML 4/6/12 - 110V, 240V and 415V, 50 Hz
12A 20A MX 12 1 NO CS94025 3720 10
12A 20A MX 12 1 NC CS94026 3720 10
Lauritz Knudsen, 15.08.2026 05PDF page 13 4 Pole Power Contactors [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
4 Pole Power Contactors [8536]
4 Pole Power Contactors - Type MCX Notes for MCX:
1) # Add-on blocks can be ordered separately.
Features 2) For ordering MCX add-on aux contact blocks, please refer page No.8
› Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 3) For ordering MCX surge suppressor and MIL kit, please refer page No.9
4) For Ordering Suffix, please refer page No.10
› Range from 18A - 900A
5) Standard Coil Voltage: MCX - 220V, 240V and 415V 50Hz
› Wide operating band up to 130A AC-1 6) Mounting of side add-on aux. contact block is not recommended for
› Power contacts configuration - 4 NO mechanically interlocked MCX 11/12/13 contactors
7) MCX 01-04 and MCX 11-13 available in 48V DC coil. Contact nearest branch
for more details.
To avoid coil failure due to neutral floating, it is recommended to use 415V coil
MCX 22 MCX 34 MCX 47 AST System Components [9032]
AC-1 M.R.P. Std.
Aux
Size Rating
(A)
Type
Contacts
Cat. No. (`)
Per Unit
Pkg.
(Nos.)
Automatic Transfer Controllers (ATC)
18 MCX 01 # CS97009 2220 10
25 MCX 02 # CS97010 2290 10 For AuXC 2000/2100 programming
Fr 1 videos and more details please scan
32 MCX 03 # CS97011 2540 10 the QR code or click here
40 MCX 04 # CS97012 4230 10
55 MCX 11 # CS97013 6030 1 AuXC-2000 Controller
Fr 2 63 MCX 12 # CS97014 9960 1 M.R.P. (`) Std. Pkg.
Type Cat. No.
80 MCX 13 # CS97015 13410 1 Per Unit (Nos.)
105 MCX 22 # CS97017 20420 1 AuXC-2000 Controller ATC2000OOOO 52600 1
Fr 3 AuXC-2100 Controller**
130 MCX 23 # CS97018 21560 1 ATC2100OOOO 104800 1
with Optional RS485
160 MCX 32 2 NO + 2 NC CS97020 40530 1 RS485 Module for
ETACONRS485 20900 1
Fr 4 200 MCX 33 2 NO + 2 NC CS97021 43520 1 AuXC-2100 Controller**
255 MCX 34 2 NO + 2 NC CS97022 54260 1 Can be used along with ACB, Motorised MCCBs, MCX contactors & Motorised
Changeover switches
325 MCX 41 2 NO + 2 NC CS97023 85680 1 **Note: RS485 expansion module needs to be ordered with AuXC-2100 for communication
360 MCX 42 2 NO + 2 NC CS97024 93280 1
400 MCX 43 2 NO + 2 NC CS97025 112980 1
Fr 5 560 MCX 44 2 NO + 2 NC CS97026 153480 1 Control Relays (Auxiliary Contactors) [8536]
600 MCX 45 2 NO + 2 NC CS97027 162240 1
700 MCX 46 2 NO + 2 NC CS97028 182060 1 Type MX0 AC
900 MCX 47 2 NO + 2 NC CS94291 294300 1
Features
2 NO + 2 NC Power Contactor - Type MCX › Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1
Features › Available with AC or DC control in same dimension
› Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 › Inbuilt Surge Suppressor in MX DC
MX0 22E
› Range from 18A - 40A
› Power contacts configuration - 2 NO + 2 NC Rated
Description Cat. No.
M.R.P. (`) Std. Pkg.
Current Per Unit (Nos.)
AC-1 M.R.P. (`) Std. For AC control std. Coil Voltage - 24, 110, 240, 415V, 50Hz
Type Power
Size Rating Cat. No. Per Unit Pkg.
Contacts 2260 10
(A) (Nos.) MX0 40E (4 NO) CS94018
18 MCX 01-22 2 NO + 2 NC CS91107 2220 10 MX0 31E (3 NO + 1 NC) CS94019 2260 10
AC-15
25 MCX 02-22 2 NO + 2 NC CS91108 2290 10 4A MX0 22E (2 NO + 2 NC) CS94020 2260 10
Fr 1 at 415V
32 MCX 03-22 2 NO + 2 NC CS91109 2540 10 MX0 13E (1 NO + 3 NC) CS94041 2260 10
40 MCX 04-22 2 NO + 2 NC CS91110 4230 10 MX0 04E (4 NC) CS94042 2260 10
Block diagrams Type MX0 DC
Single supply and 2 separate loads 2 separate supplies and 2 separate loads Rated M.R.P. (`) Std. Pkg.
Description Cat. No.
Current Per Unit (Nos.)
For DC control std. Coil Voltage - 24, 110, 220V
MX0 40E (4 NO) CS94027 2790 10
MX0 31E (3 NO + 1 NC) CS94028 2790 10
AC-15
4A MX0 22E (2 NO + 2 NC) CS94029 2790 10
at 415V
MX0 13E (1 NO + 3 NC) CS94043 2790 10
MX0 04E (4 NC) CS94044 2790 10
Notes: 1) For Ordering Suffix, please refer page No.10
2) 5 NC & above combinations are not recommended for MX0 DC Control Contactors
! MCX 2NO + 2NC contactors are not suitable for a reversing starter or for controlling a 3) 1 NO + 3 NC, 4 NC add-on block combinations are not recommended for MX0 DC
single load from 2 separate supplies. Control Contactors.
Lauritz Knudsen, 15.08.2026 06PDF page 14 Type MO0 AC Type
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Type MO0 AC Type MO0 DC
Features Features
› Same add-on aux. contact block in MO0 as of › Same add-on aux. contact block in MO0 as of
MO power contactors MO power contactors
› Common coil for 50 & 60Hz application › Inbuilt Surge Suppressor in MO0 DC
MO0 AC MO0 DC
Rated M.R.P. (`) Std. Pkg. Rated Description M.R.P. (`) Std. Pkg.
Description Cat. No. Cat. No.
Current Per Unit (Nos.) Current Per Unit (Nos.)
For AC control std. Coil Voltage - 24, 110, 240, 415V, 50Hz For DC control std. Coil Voltage - 24, 48, 110, 220
MO0 40E (4NO) CS91623 1500 10 MO0 40E (4NO) CS90045 2950 10
AC-15 AC-15
4A MO0 31E (3NO + 1NC) CS91624 1500 10 4A MO0 31E (3NO + 1NC) CS90046 2950 10
at 415V MO0 22E (2NO + 2NC) CS91625 1500 10 at 415 V MO0 22E (2NO + 2NC) CS90047 2950 10
Note: 6NC & above combination is not recommended for MO0 AC Note: 5NC & above combination is not recommended for MO0 DC
For ordering add-on contact blocks of MX0, MO0, please refer page no.8 For ordering add-on contact blocks of MX0, MO0, please refer page no.8
Capacitor Duty Contactors [8536]
Capacitor Duty Contactors - Type MO C Features
› Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1
› MO C Range available from 3 -100 kVAr, AC-6b
› Delatching type early make contacts
› Separate termination for damping resistors
› Encapsulated damping resistor assembly
› Common coil for 50 & 60Hz application
MO C50 MO C100 › Low pick-up VA consumption
kVAr Rating Built-in Std. › Standard accessories throughout the range in line with MO contactor
Type M.R.P. (`) Pkg. › Suitable for Lug as well as Lugless termination
Size @ 440V, Auxiliary Cat. No.
Per Unit (Nos.)
3Ph, 50Hz Contacts › RoHS compliant
3 MO C3 1NO CS96146 3480 1
5 MO C5 1NO CS96127 3700 1
For Power Quality Solutions,
8.5 MO C8.5 1NO CS96320 4800 1
please refer page No. 87-95
10 MO C10 1NO CS96156 4910 1
Fr 1 12.5 MO C12.5 1NO CS96321 5180 1
15 MO C15 1NO CS90019 6980 1
20 MO C20 1NO CS90021 7770 1
Note:
25 MO C25 1NO CS96322 8370 1 1) For ordering add-on aux. contact block, please refer page No.8
30 MO C30$ 1NO CS96148 13330 1 2) For ordering suffix, please refer page No.10
40 MO C40 1NO CS96147 22120 1 3) For ordering spare coils, please refer page No.11
50 MO C50 1NO CS96324 24830 1 4) Standard coil voltage : 240V, 50/60 Hz
Fr 2
5) For ordering MO C surge suppressor, please refer page No.9
60 MO C60$ 1NO CS96149 25820 1
75 MO C75 1NO CS96150 30870 1 If using 16 sq mm cable use of spreader link kit is mandatory
Fr 3 85 MO C85 1NO CS96157 33220 1 For ordering spreader link kit, Please refer page No.9
100 MO C100$ 1NO CS96158 33870 1 Spreader link along with phase barrier included in packing
Definite Purpose Contactors [8536]
Two Pole Contactors - Type MU-2P
Features
› Wide band potted coil
› Neutral isolation
MU 16-2P
Std.
AC3 Rating (A) Type M.R.P. (`)
Cat. No. Pkg.
Per Unit (Nos.)
16A MU16-2P CS90117 1600 10
25A MU25-2P CS90118 1950 10
40A MU40-2P CS90119 2500 10
Note:
1) Coil voltages available for MU-2P are 220V, 240V, wide band coil 160-220V
2) Ordering suffix for wide band coil of MU-2P is NOOO
3) For ordering add-on aux. contact block, please refer page No.8
Lauritz Knudsen, 15.08.2026 07PDF page 15 Accessories - Add-on Auxiliary Contact Blocks [8538]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Accessories - Add-on Auxiliary Contact Blocks [8538]
MNX MNX MO MO MDX MCX MCX
ML MX MX0 MO0 MO C MU-2P
9-80 95-650 9-110 140-300 9-115 01-23 32-47
Front add-on possible Yes No Yes No No Yes Yes Yes No Yes Yes No Yes
Side add-on possible Yes Yes Yes Yes Yes No Yes Yes Yes No No Yes No
Note: 1) Mounting of side add-on aux. contact block is not recommended for mechanically interlocked MCX 11/12/13 contactors
2) Accessories are common for MNX 2P & MNX 3P contactors
Front Mounting
Add-on aux. Contact Block
MNX / MCX MO / MO0 MDX Front MX Front MU-2P
Front Add-on Front Add-on Add-on Add-on Front Add-on
aux. contact Block aux. contact Block aux. contact Block aux. contact Block aux. contact Block
Suitable for
Front MX
Mounting MNX 9-80 / M.R.P. (`) MO 9-110 / M.R.P. (`) MDX# M.R.P. (`)
(6,9,12)
M.R.P. (`)
MU-2P
M.R.P. (`)
MCX 01-23 Per Unit MO0 Per Unit 9-115 Per Unit /MX0 Per Unit Per Unit
4 NO CS94112^ 1195 CS94594^ 1590 CS94033^ 1120 - -
3 NO + 1 NC CS94113^ 1195 CS94595^ 1590 CS94034^ 1120 - -
2 NO + 2 NC CS94114^ 1195 CS94596^ 1590 CS96569~ 2600 CS94035^ 1120 - -
1 NO + 3 NC CS94115^ 1195 CS94597^ 1590 CS90906~ 2600 CS94036^ 1120 - -
4 NC CS94116^ 1195 CS94598^ 1590 CS94037^ 1120 - -
2 NO CS94117^ 785 CS94591^^ 915 CS94030^ 725 CS90692^ 940
1 NO + 1 NC CS94118^ 785 CS94592^^ 915 CS96568~ 1520 CS94031^ 725 CS90693^ 940
2 NC CS94119^ 785 CS94593^^ 915 CS94032^ 725 CS90694^ 940
1 NO CS94120^ 400 CS94585^^ 535 CS90695^ 480
CS96586~ 850
1 NC CS94121^ 400 CS94586^^ 535 CS90696^ 480
#
For MDX Side add-on and top add-on can not be mounted together
*MDX add-on available till stock last
Side Mounting
Add-on aux. Contact Block MNX/MCX MO/MO C
Side Add-on aux. contact Block Left Add-on aux. contact Block
Suitable for
Side
Mounting Aux MNX 9-40 / M.R.P. (`) MCX M.R.P. (`) MNX 50-80 / M.R.P. (`) MO 9-110/ M.R.P. (`)
Contact MCX 01-04 Per Unit 11-13 Per Unit MCX 22-23 Per Unit MO C 3-100 Per Unit
First left 1 NO + 1 NC CS94220^ 1265 CS94201^ 1370 CS94201^ 1370 CS94580^ 1475
First Right 1 NO + 1 NC CS94221^ 1265 CS94202^ 1370 CS94202^ 1370 CS94581^ 1475
Second Left 1 NO + 1 NC CS94203^ 1370 CS94582^ 1475
Second right 1 NO + 1 NC CS94204^ 1370 CS94583^ 1475
Note: Mounting of side add-on aux. contact block is not recommended for mechanically interlocked MCX 11/12/13 contactors
For MO 9-18, only First left and Second left side add-on is allowed.
Side Mounting
Add-on aux. Contact Block
Suitable for
Side
Mounting Aux MNX 95-650/ M.R.P. (`) MO M.R.P. (`) MDX# M.R.P. (`)
Contact MCX 32-47 Per Unit 140-300 Per Unit 9-115 Per Unit
First left 1 NO + 1 NC CS94205^ 1555 CS95033^ 1815
ST94985^ 3110
First Right 1 NO + 1 NC CS94206^ 1555 CS95034^ 1815
Second Left 1 NO + 1 NC CS94207^ 1555 CS95035^ 1815 MDX
Side Add-on aux.
Second right 1 NO + 1 NC CS94208^ 1555 CS95036^ 1815 contact Block
#
For MDX Side add-on and top add-on can not be mounted together
- Standard Packing is 1 ^Standard Packing is 10 ^^Standard Packing is 20
* MDX add-on available till stock last
Lauritz Knudsen, 15.08.2026 08PDF page 16 Accessories - Add-on Auxiliary Contact Blocks [8538]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Accessories - Add-on Auxiliary Contact Blocks [8538]
Side Mounting Add-on aux. Contact Block -ML
ML Add-on aux. contact Block
Suitable for
Side M.R.P.
Mounting M.R.P. (`)
Aux Contact ML 4/6 (`) ML 12
Per Unit
Per Unit
Left 1 NO + 1 NC SS91494^ 1920
Right 1 NO + 1 NC SS91474^ 1920
Note: Ordering Suffix for Add-on aux. contact blocks : OOOO
Accessories - Surge Suppressors [8538]
Std.
For MX, MNX, MCX, MO & MO C For Contactor Cat. No.
M.R.P. (`)
Pkg.
Per Unit
(Nos.)
MX 06 to MX 12 / MX 0 AC (S1) CS94039* 1050 10
MNX 9 - 40 / MCX 01 - 04 (S1) CS94166* 1070 10
MNX 50 - 80 / MCX 11 - 23 (S3) CS94163* 1195 10
MNX 95 - 250 / MCX 32 - 34 (S4) CS94164# 3910 10
MNX 300 - 400 / MCX 41 - 44 (S6) CS94165# 5280 10
MX - S1
MO Frame 0/1, MO C Frame 1, MO0 Control CS91706^ 1070 10
Ordering Suffix * 110-240V : BOOO, 415V : DOOO
#
110V : AOOO, 220-240V : BOOO, 360-525V : DOOO MO/MO C - Frame 2 CS91707^ 1195 10
^ 110V : AOOO, 220-320V : BOOO, 360-415V : DOOO MO/MO C - Frame 3 CS91708^ 3910 10
MDX 9-115, MNX 550-650, MCX 45-47, MX DC, MX0 DC & MO0 DC MO Frame - 4/5 CS91854^ 5280 10
have built in surge suppressor
Accessories - Mechanical Interlock Kits & Spreader Link Kit [8538]
Mechanical Interlock Kit for MX, MO, MDX, MO / MO C Spreader Link Kit
MNX & MCX
MCX M3 (MCX 22)
Std. Std.
M.R.P. (`) For Contactor M.R.P. (`)
For Contactor Cat. No. Pkg. Cat. No. Pkg.
Per Unit Per Unit
(Nos.) (Nos.)
MX 06 to MX 12 / MX 0 CS94038 1010 10 MO 9 - 45 / MOC 3 - 30 CS94274 950 10
MO 9 - 110* CS94584 1795 10 MO 50 - 70 / MOC 40 - 60 CS94093 1505 10
MDX 9 - 38 CS96572 1990 1
MO 80 - 110 / MOC 75 - 100 CS94094 2170 1
MDX 50 - 115 CS96573 6040 1
MO 140 - 225 CS91057 6110 1
MNX 9 - 40 CS94126 820 10
MNX 50 - 80 CS94197 5770 1 MO 250 - 300 CS90940 9500 1
MNX 95 - 140 CS94198 8990 1 Note:
MNX 185 - 250 CS94199 10220 1 1) If using 16 sq mm cable for MO 45/ MO C25 use of spreader link is mandatory
MNX 300 - 650 CS94200 11580 1 2) Spreader Link Kit consists of six terminals along with phase barrier
MCX 01 - 04 CS94126 820 10 (Phase barrier not applicable for MO 250-300)
3) In MO C 30, MO C 60 & MO C 100 spreader link is included in packing
MCX 11 - 13 ST50540 1625 10
4) Ordering Suffix: OOOO
MCX 22 - 23 CS93095 7620 1
! 5) Insert spreader link in top slot only
MCX 32 - 34 SS94992 7870 1
MCX 41 - 47 CS94301 12980 1
*MDX Mechanical interlock kit Available till stock last
Note:
1) Ordering Suffix for Mechanical Interlock Kits : OOOO
2) *MO MIL Kit contains inbuilt 2 NC Contacts
3) Mounting of side add-on aux. contact block is not recommended for mechanically interlocked MCX 11/12/13 contactors
4) MIL kit for MNX 50-80 comes with 2 left & 2 right side add-on aux. contact blocks i.e. 4 NO + 4 NC
Lauritz Knudsen, 15.08.2026 09
5) MIL kit for MCX 22/23 comes with 2 left & 2 right side add-on aux. contact blocks i.e. 4 NO + 4 NCPDF page 17 Accessories - Connecting Links [8538]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Accessories - Connecting Links [8538]
DOL Starter - Link Reversing DOL Starter - Link
Contactor Reversing Paralleling Contactor
MMS Link Starter Link MMS Link
M.R.P. Std. M.R.P. Std.
Suitable For Cat. No. (`) Pkg. Suitable For Cat. No. (`) Pkg.
Per Unit (Nos.) Per Unit (Nos.)
MOG H1/S1 with MO 9-18 CS90396 # 785 10 MOG H1/S1 with MO 9-18 CS90548 # 1970 10
MOG H1/S1 with MO 25-45 CS90391 # 785 10 MOG H1/S1 with MO 25-45 CS90546 # 1970 10
Star Delta Starter - Link Example of Star Delta Starter
Connection with Link
MMS
MMS
MPCB
Reversing / Paralleling Contactor Shorting
star delta Link Link MMS Link Link MMS
MPCB
LINK
M.R.P. Std.
Suitable For Cat. No. (`) Pkg.
Per Unit (Nos.)
MOG H1/S1 with MO 9-18 CS90549 # 2390 10
MOG H1/S1 with MO 25-45 CS90547 # 2390 10
#
Ordering Suffix OOOO
Ordering Suffix for Standard Coil Voltages
Ordering Suffix for Standard Coil Voltages Ordering suffix for Electronic coil Contactor
AC Control DC Control* AC / DC control
Voltage (V) Suffix Voltage (V) Suffix Voltage (V) Suffix Contactor
24 GOOO 24 4OOO 20-48 JOOO MDX 50-115
110 AOOO 48 5OOO 60-110 AOOO MDX 50-115
220 KOOO 110 1OOO 110-240 BOOO MDX 50-115 & MO 140-300
240 BOOO 220 2OOO 240-415 DOOO MO 140-300
415 DOOO Note:
440 POOO 1) * For MX DC, MDX 9-38, MX0 DC, MO0 DC
2) For other coil voltages please contact nearest branch office
Lauritz Knudsen, 15.08.2026 10PDF page 18 Spares [8538]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Spares [8538]
Spare Contact Kit and Spare Coil Spare Contact Kit and Spare Coil
MNX Spare Coils MCX Spare Kits
Spare Contact kit Spare Coil
ML Spare Kits
Type Cat. No. M.R.P. (`) Cat. No. M.R.P. (`)
Per Unit Per Unit
MO 9 (1 NO ) CS94843 ^ 1220
MO 12 (1 NO ) CS94844^ 1580 CS94841^ 1030
MO 18 (1 NO) CS94845^ 1740
ML Spare Coils
MO 9 CS96380^~ 1220
Spare Contact kit Spare Coil MO 12 CS96381^~ 1580
M.R.P. (`) M.R.P. (`) MO 18 CS96382^~ 1740
Type Cat. No. Cat. No.
Per Unit Per Unit MO 25 CS96383^~ 2020 CS96317^ 1265
ML 1.5 5575 SS90873 ^ 1840 MO 32 CS96384^~ 4565
SS95305^
MO 40 CS96385^~ 7705
ML 2 SS95307^ 10200
SS90545 ^ 3410 MO 45 CS96386^~ 7800
ML 3 SS95309^ 18020
MO 50 CS96387^~ 8175
ML 4 SS95311^ 26710
SS91258 ~ MO 60 CS96388^~ 10590 CS96318^ 3900
MO Contactors
6665
ML 6 SS95313^ 49415
MO 70 CS96389^~ 11755
ML 10 SS95315~ 96245 MO 80 CS96390^~ 16175
SS91011 ~ 14220
ML 12 SS95317~ 103715 MO 95 CS96391^~ 20400 CS96319^ 6740
MR - - CS94102 ^ 1400 MO 110 CS96392^~ 29805
MU16-2P CS90217^ 540 MO 140 CS90357~ 35490
MU25-2P CS90218^ 715 CS90793 ^ 620 MO 185 CS90358~ 42580 CS90356~ 15970
MU40-2P CS90219^ 1020 MO 225 CS90359~ 48755
MO 0 AC - - CS94841 ^ 1030 MO 250 CS94444~ 58615
CS94442~ 23295
* MR Coils available till stock last MO 300 CS94443~ 66155
Note: MO 140 (electronic coil) CS90357~ 35490
1) Coil voltages available for MU-2P are 220V, 240V, wide band coil 160-220V MO 185 (electronic coil) CS90358~ 42580 CS90855~ 28930
2) Ordering suffix for wide band coil of MU-2P is NOOO MO 225 (electronic coil) CS90359~ 48755
MO 250 (electronic coil) CS94444~ 58615
CS90738~ 29060
MO 300 (electronic coil) CS94443~ 66155
MO C Spare Coils MNX 9 CS94123^ 975
M.R.P. (`) MNX 12 CS94124^ 1265
Type Cat. No.
Per Unit MNX 18 CS94125^ 1440
MO C3 - 30 CS96317^ 1265 MNX 22 CS94269^ 1600 CS94105 925
MNX 25 CS94127^ 2080 ^
MO C40 - 60 CS96318^ 3900
MNX 32 CS94128^ 4030
MO C75 - 100 CS96319^ 6740
MNX 40 CS94147^ 6560
MNX 50 CS94150^ 7230
MNX 70 CS94151^ 10890 CS94192^ 3700
Front housing & Moving bridge kit and
MNX Contactors
MNX 80 CS94152^ 14840
Combination coil with timer for MNX 95 CS94153~ 20855
CS94154~ 30195 ~
ML contactor MNX 110
MNX 140 CS94155~ 36615
CS94196 6340
MNX 185 CS94156~ 40805
~
MNX 225 CS94157~ 47185 CS94194 14480
MNX 250 CS90310~ 56170
MNX 300 CS90283~ 62795 ~
CS94195 21460
MNX 400 CS94161~ 94780
Front housing and moving bridge kit MNX 550 CS94162~ 127350 ~
CS94193 45355
MNX 650 CS96336~ 198840
Type M.R.P. (`)
Cat. No.
Per Unit MCX 01-04 - - CS94105 ^ 925
MCX 11 CS94077^ 3270
ML 1.5 ST28734~ 1765
MCX 12 CS94078^ 7170 CS94009 ^ 1110
ML 2/ ML 3 ST23866~ 2410
MCX 13 CS90307^ 11115
ML 4/ ML 6 ST28735~ 4370 MCX 22 CS94331~ 13745
ST91291* ~ 3110
Combination coil with timer MCX 23 CS90078~ 15465
M.R.P. (`) MCX 32 CS94082^ 26425
MCX Contactors
Type Cat. No. ~
6340
Per Unit MCX 33 CS94083^ 31060 CS94196
ML 2 SS90650 ~
7530 MCX 34 CS94084^ 36965
MCX 41 CS94295~ 53585
Note:
MCX 42 CS94296~ 61300 ~
1) Ordering Suffix for Spare Contact kit - OOOO CS94195 21460
2) For Spare Coil Ordering Suffix refer page No. 10 MCX 43 CS94297~ 73555
MCX 44 CS94298~ 103955
~ Standard Packing is 1 MCX 45 CS94299~ 102040
^~ Standard Packing is 5 CS94300~ 112960 CS94193
~
45355
MCX 46
^ Standard Packing is 10
MCX 47 CS90308~ 179215
~~ Standard Packing is 50
* Ordering Suffix for 240V AC - FOOO, 415V AC - ROOO
Lauritz Knudsen, 15.08.2026 11PDF page 19 Thermal Overload Relays [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Thermal Overload Relays [8536]
Type MN - Suitable for MNX Contactor Type RTO - Suitable for MO Contactor
Features Features
› Available in 3 frame sizes from 0.2-570 A › Ambient temperature compensated upto 55oC
› Ambient temperature compensated up to 55оC › Built-in Single Phasing protection
› Built-in Single Phasing protection › Manual and auto reset mode
› Manual and auto reset mode › Front access to START and STOP/RESET buttons
› Conforms IS/IEC 60947-4-1 & IEC 60947-4-1 › Sealable in OFF condition
› Conforms IS/IEC 60947-4-1 & IEC 60947-4-1
MN 2 MN 5 MN 12 MN 12L RTO 1 RTO 2 RTO 3
Type of M.R.P. Std. Type of M.R.P. Std.
Relay Range Relay Range
Mounting Cat. No. (`) Pkg. Mounting Cat. No. (`) Pkg.
(A) (A)
(Operation) Per Unit (Nos.) (Operation) Per Unit (Nos.)
Direct Mounting on MNX 9 - 40 Direct Mounting on MO 9 - 45
0.2 - 0.33 SS94141OOEO 2680 10 0.23 - 0.41 CS96355OOFO 4090 10
0.3 - 0.5 SS94141OOGO 2680 10 0.31 - 0.55 CS96355OOGO 4090 10
0.45 - 0.75 SS94141OOJO 2680 10 0.55 - 0.85 CS96355OOJO 4090 10
0.6 - 1 SS94141OOKO 2680 10 0.78 - 1.2 CS96355OOLO 4090 10
0.9 - 1.5 SS94141OOMO 2780 10 1.2 - 2.0 CS96355OONO 4090 10
MN 2 1.4 - 2.3 SS94141OOPO 2780 10 1.9 - 2.8 CS96355OOPO 4280 10
RTO - 1
(Directly 2 - 3.3 SS94141OOQO 2780 10 2.4 - 3.6 CS96355OOQO 4280 10
(Directly
Operated) 3-5 SS94141OOSO 2780 10 3.5 - 5.2 CS96355OOSO 4280 10
Operated)
4.5 - 7.5 SS94141OOUO 2780 10 4.6 - 6.7 CS96355OOTO 4280 10
6 - 10 SS94142OOVO 2780 10 6.7 - 9.7 CS96355OOVO 4280 10
9 - 15 SS94142OOBO 2900 10 8.5 - 12.5 CS96355OOAO 4330 10
14 - 23 SS94144OODO 3070 10 12.5 - 18.5 CS96356OOCO 4800 10
20 - 33 SS94145OOEO 4630 10 17 - 25.5 CS96356OODO 4800 10
24 - 40 SS94145OOFO 4840 10 25 - 37 CS96356OOEO 7300 10
Direct Mounting on MNX 50 - 80 35 - 45 CS96356OOGO 7530 10
9 - 15 SS94135OOBO 5730 10 Direct Mounting on MO 50 - 70
14 - 23 SS94135OODO 5730 10 5 - 7.5 CS96366OOUO 8610 1
MN 5 7 - 11 CS96366OOVO 8610 1
20 - 33 SS94136OOEO 5730 10
(Directly
30 - 50 SS94136OOGO 7610 10 RTO - 2 10.5 - 16 CS96366OOBO 8610 1
Operated)
36 - 60 SS94136OOTO 7700 10 (Directly 15 - 21 CS96366OOCO 8610 1
Operated) 20 - 31 CS96366OOEO 8960 1
45 - 75 SS94137OOJO 8870 10
66 - 110 SS94137OOKO 9520 10 30 - 43 CS96366OOFO 9970 1
Separate Mounting 40 - 57 CS96366OOSO 11920 1
SB94211OOGO 50 - 75 CS96367OOJO 12320 1
28 - 46.5 14010 1
Direct Mounting on MO 80 - 110
42 - 69 SS94138OOHO 14010 1
23 - 30 CS90873OOEO 13140 1
MN 12 60 - 100 SS94138OOKO 14010 1
(CT Operated) RTO - 3 29 - 38 CS96303OOQO 13660 1
90 - 150 SS94138OOMO 14010 1
(Directly 37 - 49 CS96304OOGO 14090 1
135 - 225 SS94138OOPO 15700 1
Operated) 47 - 62 CS96312OOTO 14350 1
180 - 300 SS94139OOQO 17610 1
60 - 78 CS96313OOJO 16910 1
270 - 450 SS94139OORO 22110 1
75 - 110 CS96314OOKO 18470 1
Separate Mounting
Separate Mounting
42 - 69 SS94127OOHO 41570 1
23.4 - 36 CS97096OOGO 22180 1
60 - 100 SS94127OOKO 41570 1
MN 12L # 36 - 60 CS97096OOJO 22180 1
(CT Operated) 90 - 150 SS94127OOMO 41570 1
57 - 84 CS97096OOKO 22180 1
135 - 225 SS94127OOPO 41570 1 RTO - 4
(CT Operated) 72 - 108 CS97096OOLO 22180 1
180 - 300 SS94127OOQO 41570 1
105 - 156 CS97096OOMO 22180 1
340 - 570 SS94127OOSO 41570 1 138 - 201 CS97096OONO 26320 1
# For motors with longer starting time (Trip class 30) 201 - 291 CS97096OOQO 27490 1
255 - 375 CS97096OORO 33710 1
Lauritz Knudsen, 15.08.2026 12PDF page 20 Thermal Overload Relays [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Thermal Overload Relays [8536]
Type RX Type ML
Features
› Direct mounting on MX contactor
› Built-in single phasing protection
› Front access to START and STOP/RESET buttons ML
Type of M.R.P. Std. Type of M.R.P. Std.
Relay Range Relay Range
Mounting Cat. No. (`) Pkg. Mounting Cat. No. (`) Pkg.
(A) (A)
(Operation) Per Unit (Nos.) (Operation) Per Unit (Nos.)
0.23-0.41 CS96357OOFO 2420 10 Direct Mounting on ML 1.5 Contactors
0.45-0.78 CS96357OOJO 2420 10 0.15 - 0.25 SS91858OODO 6710 10
RX 0.78-1.2 CS96357OOLO 2420 10 0.25 - 0.4 SS91858OOFO 6710 10
(Directly 1.2-1.9 CS96357OONO 2420 10 0.4 - 0.65 SS91858OOHO 6710 10
Operated) 0.6 - 1 SS91858OOKO 6710 10
1.8-2.8 CS96357OOPO 2420 10 ML 1
2.6-3.6 CS96357OOQO 2420 10 (Directly 1 - 1.6 SS91858OOMO 6710 10
Direct
Operated) 1.5 - 2.5 SS91858OOPO 6710 10
Mounting on 3.6-5.2 CS96357OOSO 2420 10
MX Contactors 4.8-7 CS96357OOTO 2420 10 2.5 - 4 SS91858OORO 6710 10
6.4-9.7 CS96357OOVO 2420 10 4 - 6.5 SS91858OOTO 6710 10
8.2-12.1 CS96357OOAO 2420 10 6 - 10 SS91858OOVO 6710 10
10 - 16 SS91858OOBO 6710 10
Type MU-2P (2 Pole) 11 - 18 SS91858OOCO 6710 10
Direct Mounting on ML 2/3 Contactors
ML 2 / ML 3 9 - 14 SS91859OOAO 9930 10
(Directly 13 - 21 SS91859OOCO 9930 10
Operated) 20 - 32 SS91859OOEO 9930 10
MU-2P 28 - 42 SS91859OOFO 9930 10
Type of Relay Range M.R.P. Std. Type of Relay Range M.R.P. Std.
Mounting Cat. No. (`) Pkg. Mounting Cat. No. (`) Pkg.
(A) (A)
(Operation) Per Unit (Nos.) (Operation) Per Unit (Nos.)
MU 2P (2 Pole) MU 2P (2 Pole)
Direct 1 - 1.6A CS90207OOMO 1130 1 Direct 11 - 18A CS90207OOCO 1260 1
Mounting on 1.5 - 2.5A CS90207OOPO 1130 1 Mounting on 13 - 22A CS90207OODO 1260 1
MU-2P 2.5 - 4A CS90207OORO 1130 1 MU-2P 16 - 26A CS90207OOBO 1260 1
Contactor 4 - 6.5A CS90207OOTO 1130 1 Contactor 20 - 32A CS90207OOEO 1580 1
6 - 10A CS90207OOVO 1130 1 26 - 40A CS90207OOFO 1580 1
9 - 14A CS90207OOAO 1130 1
Accessories for Thermal Overload Relays [8538]
Accessories for Thermal Overload Relays Relay Reset Cord for MN & RTO relay
Relay Mounting Kit Kit for Mounting MN5 Relay Din Rail Mounting Kit
MN2 Relay 400 mm 650 mm 900 mm 1200 mm
M.R.P. Std. M.R.P. (`) Std. Pkg.
Description Cat. No.
Description Cat. No. (`) Pkg. Per Unit (Nos.)
Per Unit (Nos.)
MN Relay reset cord - 400mm SB94207OOOO 1430 1
Push button extn. unit for MN 2 Relays SS94968OOOO 115 100
Kit for Mounting MN 2 Relay on MN Relay reset cord - 650mm SB94208OOOO 1490 1
ML 1.5 contactor SS94701OOOO 395 50
Kit for Mounting MN 2 Relay MN Relay reset cord - 900mm SB94209OOOO 1525 1
separately (Direct Mounting Type) SS94700OOOO 395 50
MN Relay reset cord - 1200mm SB94210OOOO 1715 1
Kit for Mounting MN 5 Relay on
MNX 95 / 110 / 140 contactor SS94638OOOO 635 20 RTO Relay reset cord - 400mm CS90941OOOO 1
1430
Kit for Mounting MN 5 Relay on
ML 2 / ML 3 contactor SS94151OOOO 410 20 RTO Relay reset cord - 650mm CS90942OOOO 1490 1
Kit for Mounting MN5 Relay on RTO Relay reset cord - 900mm CS90943OOOO 1525 1
ML 4 / ML 6 contactor SS94152OOOO 565 20
DIN Rail Mounting Kit Relay on RTO Relay reset cord - 1200mm CS90944OOOO 1715 1
MN 2 Relay SS91887OOOO 310 50
M.R.P.(`) Std. Pkg.
Description Cat. No.
Per Unit (Nos.)
Separate Mounting Kit for RTO-1 Relay Separate Mounting Kit CS96335OOOO 535 1
RTO Relay RTO-2 Relay Separate Mounting Kit CS96306OOOO 1260 1
RTO-3 Relay Separate Mounting Kit CS96307OOOO 1800 1
Lauritz Knudsen, 15.08.2026 13PDF page 21 Electronic Motor Protection Relay [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Electronic Motor Protection Relay [8536]
Type REO - Electronic Overload Relay To Experience the Benefits of
REO Electronic Overload Relay
Features
› Protections: › Trip indication
» Overload › Selectable Trip class - 10A, 10,
Click or Scan
» Single Phasing, Phase unbalance 20, 30 as per IEC 60947-4-1
» Locked Rotor › Conforms IS/IEC 60947-4-1 & IEC 60947-4-1
» Earth Fault in REO 1.1G & REO 4G
With in-built earth fault
Without earth fault protection protection
Relay Std.
Type of Range Pkg.
Model Mounting M.R.P. Model M.R.P.
(A) Cat. No. (`) Cat. No. (`) (Nos.)
Per Unit Per Unit
0.15 - 0.75 CS90418OOJO 10540 CS90423OOJO 17570 10
Direct 0.6 - 3 CS90418OOQO 10540 CS90423OOQO 17570 10
REO 1.1 REO 1.1G
Mounting on
MO 9-45 2.4 - 12 CS90418OOLO 10540 CS90423OOLO 17570 10
9 - 45 CS90418OOGO 11830 CS90423OOGO 18160 10
REO 4 Separate 18-90 CS90418OOUO 31220 REO 4G CS90423OOUO 31520 1
Mounting 72-360 CS90418OORO 42780 CS90423OORO 42940 1
Type REO - Electronic Over Current Relay
Electronic Overcurrent Relay (EOCR) is a type of Electronic relay that has tripping based on Definite mean time characteristics.
The tripping of relay is decided by trip time selected by user.
Features
› Protections: › Settable start time (5s, 10s, 20s, 40s)
» Overload and trip time (2s, 4s, 8s, 16s)
» Single Phasing, Phase unbalance › Trip indication
» Locked Rotor › Conforms IS/IEC 60947-4-1 & IEC 60947-4-1
Relay M.R.P. Std. Accessories for REO - Electronic Overload Relay
Model Type of Range Cat. No. (`) Pkg.
Mounting Std.
(A) Per Unit (Nos.) M.R.P.
Description Cat. No. (`) Pkg.
0.15 - 0.75 CS91911OOJO 13540 1 Per Unit (Nos.)
Direct 0.6 - 3 CS91911OOQO 13540 1
REO 1.1c REO Relay Reset Cord - 400mm CS90425OOOO 1430 1
Mounting on
MO 9-45 2.4 - 12 CS91911OOLO 13540 1 Separate Mounting Kit for
REO 1.1/1.1G/1.1c Relay CS96335OOOO 535 1
9 - 45 CS91911OOGO 13540 1
Lauritz Knudsen, 15.08.2026 14PDF page 22 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 23 Microcontroller based Motor Protection Relay [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Microcontroller based Motor Protection Relay [8536]
eMPR150 - Electronic Motor Protection eMPR300 - Electronic Motor Protection
Relay Relay with Built-in Earth Fault Protection
› Protections › Protections
» Overload » Overload
» Locked Rotor » Locked Rotor
» Single Phasing, Current Unbalance, » Single Phasing, Current Unbalance,
» Under Current » Under Current
› Inbuilt CT’s (1 A to 88 A) » Earth Fault
› Trip indication » Phase Sequence Reversal
› Test facility › Inbuilt CT’s (1 A to 88 A)
› Site Selectable – Fail-safe / Non › Trip indication
Fail-safe mode › Test facility
› Selectable trip class - 10A, 10, 20 › Site Selectable Phase Sequence -
and 30 as per IEC 60947-4-1 RYB/ RBY
› Site Selectable – Fail-safe / Non
Fail-safe mode
› Selectable trip class - 10A, 10, 20
and 30 as per IEC 60947-4-1
M.R.P. M.R.P.
Thermal O/L Device Model Aux.Supply Thermal O/L Device Cat. No.
Model Aux.Supply Cat. No. (`) (`)
Range (A) Code Range (A) Code
Per Unit Per Unit
1-5.5 EMPR150XAAO 4480 1-5.5 EMPR300XAAO 11760
110V 4-22 EMPR150XABO 6830 110V 4-22 EMPR300XABO 14110
AC AC
16-88 16460
eMPR150
16-88 49, 51LR, EMPR150XACO
9180 eMPR300 49, 51LR, EMPR300XACO
1-5.5 37, 46 EMPR150XBAO 4480 1-5.5 64, 37, 46 EMPR300XBAO 11760
230V 4-22 EMPR150XBBO 6830 230V 4-22 EMPR300XBBO 14110
AC AC
16-88 EMPR150XBCO 9180 16-88 EMPR300XBCO 16460
eMPR selection must be done as per Line Current of Motor eMPR selection must be done as per Line Current of Motor
eMPR300D - Electronic Motor Protection eMPR300I - Electronic Motor Protection Relay
Relay with inbuilt display with inbuilt display & Modbus RTU Communication
One solution for both EOLR and EOCR applications One solution for both EOLR and EOCR applications
› Protections › Protections
» Overload » Overload
» Locked Rotor » Locked Rotor
» Single Phasing, Current Unbalance, » Single Phasing, Current Unbalance,
» Dry Run Protection with Programmable » Dry Run Protection with Programmable
Under Current Under Current
» Earth Fault » Earth Fault
» Phase Sequence Reversal » Phase Sequence Reversal
» Overcurrent » Overcurrent
› 7 Segment LED Display › 7 Segment LED Display
› Inbuilt CT’s (1 A to 88 A) › Inbuilt CT’s (1 A to 88 A)
› 5 trip records › 5 trip records
› Test facility › Test facility
› Site Selectable – Fail-safe / Non › Site Selectable – Fail-safe / Non
Fail-safe mode Fail-safe mode
› Selectable trip class - 10A, 10, 20 › Selectable trip class - 10A, 10, 20
and 30 as per IEC 60947-4-1 and 30 as per IEC 60947-4-1
› Inbuilt Communication port
Modbus - RS-485
M.R.P. M.R.P.
Model Aux.Supply Thermal O/L Device Cat. No. (`) Model Aux.Supply Thermal O/L Device Cat. No. (`)
Range (A) Code Per Unit Range (A) Code Per Unit
1-5.5 EMPR300DCAO 12390 1-5.5 EMPR300ICAO 17850
85-265V 37, 46, 49, EMPR300DCBO 14600 85-265V 37, 46, 49, EMPR300ICBO 20060
eMPR300D 4-22 eMPR300I 4-22 51LR, 51, 64
AC 51LR, 51, 64 AC
16-88 EMPR300DCCO 16800 16-88 EMPR300ICCO 22260
eMPR selection must be done as per Line Current of Motor eMPR selection must be done as per Line Current of Motor
Lauritz Knudsen, 15.08.2026 16PDF page 24 Microcontroller based Motor Protection Relay [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Microcontroller based Motor Protection Relay [8536]
Application Schemes : eMPR150, eMPR300, eMPR300D, eMPR300I
R R R
Y Y Y
B B B
SCPD SCPD SCPD
In case of Reversible starters; eMPR must sense Line current
eMPR must be placed before in case of STAR-Delta Starter
the reversing contactors.
Contactor Forward Reverse
Contactor Contactor
Line
Contactor
Delta Star
Contactor Contactor
3Ø
Motor
3Ø 3Ø
Motor Motor
DOL RDOL Star - Delta
eMPR300D or eMPR300I with External 5P10 Class CTs for Motors with FLC > 88 Amp
Compact Motor Protection Relay - MM10 Draw-out Motor Protection Relay - MPR21
Features › MPR21 – 37, 46, 48, 49, 50BF, 50, 51, 50N, 51N, 51LR, 64, 66, 74TCS.
› Flush Mounting with display › Microcontroller-based design
› Last trip data recording › Draw-out enclosure.
› Protections:
› CT rating#- 1A/ 5A (site selectable)
» Thermal Overload with pre-alarm
» Short Circuit › Display of 250 event and 30 Trip records
» Earth fault › 128*64 graphical display
» Phase loss, Unbalance, Phase reversal › Modbus RS-485 Communication
» Under Current › Front Micro USB port for numrAL Suite
» Prolong starting, Locked Rotor
Aux. M.R.P. M.R.P. (`)
CT# Device Model Aux. Supply (V) Communication Cat. No.
Model secondary Cat. No. (`) Per Unit
Supply code
Per Unit
20 - 60V DC Modbus RS 485 NRMPR2A28RA 69000
37, 46, 49, numrAL
110 - 240 V MPR21 85 - 265V AC,
MM10* 5 Amp 50 / 51, MM10240E005 46640 Modbus RS 485 NRMPR2B28RA 69000
AC / DC 87 - 265V DC
51LR, 64
#
#
- Protection Class CT - Protection Class CT
*- Available till stock last
Lauritz Knudsen, 15.08.2026 17PDF page 25 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 26 iMMR - Intelligent Motor Management Relay [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
iMMR - Intelligent Motor Management Relay [8536]
Display Unit iMMR is a comprehensive Motor protection, control and monitoring
relay for intelligent MCC’s
“Besides control, protection and diagnostics, iMMR provides accurate
real time data for analytics and insights into the performance of plant
and process”
Features
› Comprehensive Current & Voltage based Protections
› 20 nos. of last trip records, 100 event records and 20 IRF Records
are available
› Preprogrammed Starter logics reduces manufacturing and
commissioning time
› Software iMMR Suite is available for Easy and effective
configuration and monitoring
› Ethernet IP, Profinet, Modbus RTU, Modbus TCP/IP and Profibus-
DP protocols available for seamless integration with DCS/PLC
› Redundant network for seamless Motor control and monitoring,
iMMR Main Unit CT Unit with Profinet/ Ethernet IP
Description M.R.P. (`)
Product Cat. No.
Per Unit
iMMR MODBUS RTU 85-265 VAC/DC CS91244OOOO 30000
iMMR PROFIBUS-DP 85-265 VAC/DC *Available On Request
Main Unit iMMR MODBUS TCP/IP 85-265 VAC/DC *Available On Request
iMMR Ethernet IP 85-265 VAC/DC *Available On Request
iMMR Profinet 85-265 VAC/DC *Available On Request
CT1 (0.3-3A) with 15 cm cable CS91245OOOO 6900
CT Unit CT2 (2.5-25A) with 15 cm cable CS91246OOOO 9200
CT3 (7-70A) with 15 cm cable CS91247OOOO 14600
CT1 (0.3-3A) + VT with 15 cm cable CS91249OOOO 15900
CTVT Unit CT2 (2.5-25A) + VT with 15 cm cable CS91250OOOO 18700
CT3 (7-70A) + VT with 15 cm cable CS91251OOOO 24600
Display Unit iMMR Display unit without cable CS91253OOOO 16000
iMMR Display Cable - 1 meter XK13128OOOO 1400
Display Cable
iMMR Display Cable - 2 meter XK13129OOOO 2100
iMMR EXP 4DI + 2DO with 10 cm cable *Available On Request
iMMR EXP 6DI 110V/240V with 10cm cable *Available On Request
Expansion Unit
iMMR EXP Earth Leakage + 2DI + 2DO with 10 cm cable *Available On Request
iMMR EXP 2AI + 1AO with 10 cm cable *Available On Request
* Please contact our nearest branch for details
iMMR with external CT’s for Motors >37kW
S1
S2
-/5 Amp S1
Class 5P10
S2
S1
CT2 Main Unit
S2
Contactor
Pass Through CT
Display Unit
CT Cable
U1 V1 W1
M
Lauritz Knudsen, 15.08.2026 19PDF page 27 iMMR selection guide
Extracted reference text; use the original PDF to check column alignment, variants and price units.
iMMR selection guide
Main Unit
+ CT / CTVT
Unit
+ Display Unit
+ Display Cable
+ Expansion
Unit
= iMMR
for
one motor
For Current Add up to 5
Select based protection Select a panel Expansion
Main Unit select CT Unit. Complete
mounted Unit
based on For Current & package
Display Unit & Cable based
required Voltage based selection of
for monitoring and on DI/DO &
communication protection iMMR.
parametrization. AI/AO
protocol. select requirement.
CTVT Unit.
Cat.no. selection guide
Modbus RTU communication and Current based protection and metering
Main Unit - Display Cable -
Motor Rating Total MRP CT Unit Display Unit
Modbus RTU 2 meter
<1.1 KW 55000 CS91244OOOO CS91245OOOO CS91253OOOO XK13129OOOO
1.1 KW to 11 KW 57300 CS91244OOOO CS91246OOOO CS91253OOOO XK13129OOOO
11 KW to 37 KW 62700 CS91244OOOO CS91247OOOO CS91253OOOO XK13129OOOO
>37 KW 57300 CS91244OOOO CS91246OOOO* CS91253OOOO XK13129OOOO
* with External Protection class CT ,s of -/5Amp
Modbus RTU communication and Current + Voltage based protection and metering
Main Unit - Display Cable -
Motor Rating Total MRP CTVT Unit Display Unit
Modbus RTU 2 meter
<1.1 KW 64000 CS91244OOOO CS91249OOOO CS91253OOOO XK13129OOOO
1.1 KW to 11 KW 66800 CS91244OOOO CS91250OOOO CS91253OOOO XK13129OOOO
11 KW to 37 KW 72700 CS91244OOOO CS91251OOOO CS91253OOOO XK13129OOOO
>37 KW 66800 CS91244OOOO CS91250OOOO* CS91253OOOO XK13129OOOO
* with External Protection class CT ,s of -/5Amp
iMMR Main Unit
iMMR Display Unit
iMMR Display Cable
} iMMR CT/CTVT Unit
with 15 cm cable
Lauritz Knudsen, 15.08.2026 20PDF page 28 Manual Motor Starters [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Manual Motor Starters [8536]
Rocker Type Rotary Type Rotary Type
› MOG-S1: upto 32A › MOG-H1M: upto32A › MOG-H1: upto 32A
› Short circuit + Overload protection › MOG-H2M: 32A-63A › MOG-H2: 32A-63A
› Short circuit protection › Short circuit + Overload protection
Rocker type and Rotary Type Manual Motor Starters conforms to IEC 60947-4-1
R
Y
B
› Short circuit protection › Compact
Circuit
Breaker › High breaking capacity
› Over current protection
MMS
› Short circuit protective Overload + Short
coordination circuit protection
› Reduction in wiring work
› High switching durability
› Overload protection
› Padlocking feature
Contactor
› Phase loss protection available even without
Thermal extended rotary handle
› Wide range of current No separate
Overload › Stand alone motor OLR - Saves
adjustment dial cost of OLR
Relay protection
MMS
› Ambient temperature
› Common accessories
compensation Motor
Type MOG-S1 (Rocker Type) Type MOG-H1 (Rotary Type) - Frame1
With short circuit & overload protection With short circuit & overload protection
Recommended Thermal M.R.P. Std. Recommended Thermal M.R.P. Std.
Rating Motor Rating Instantaneous Rating Motor Rating Instantaneous
Release (`) Pkg. Release (`) Pkg.
Trip Cat. No. Trip Cat. No.
(A) at 415V, 3-Ph, range Per (Nos.) (A) at 415V, 3-Ph, range Per (Nos.)
Current (A) Current
50Hz (KW) (A) Unit 50Hz (KW) (A) Unit
0.16 - 0.1 - 0.16 2.1 ST41889OOOO 5360 1 0.16 - 0.1 - 0.16 2.1 ST41904OOOO 6000 1
0.25 0.06 0.16 - 0.25 3.3 ST41890OOOO 5360 1 0.25 0.06 0.16 - 0.25 3.3 ST41905OOOO 6215 1
0.40 0.09 0.25 - 0.40 5.2 ST41891OOOO 5360 1 0.40 0.09 0.25 - 0.40 5.2 ST41906OOOO 6215 1
0.63 0.12 0.40 - 0.63 8.2 ST41892OOOO 6105 1 0.63 0.12 0.40 - 0.63 8.2 ST41907OOOO 6950 1
1.00 0.25 0.63 - 1.00 13 ST41893OOOO 6105 1 1.00 0.25 0.63 - 1.00 13 ST41908OOOO 6950 1
1.60 0.55 1.00 - 1.60 20.8 ST41894OOOO 6135 1 1.60 0.55 1.00 - 1.60 20.8 ST41909OOOO 7175 1
2.50 0.75 1.60 - 2.50 32.5 ST41895OOOO 6135 1 2.50 0.75 1.60 - 2.50 32.5 ST41910OOOO 7175 1
4.00 1.50 2.50 - 4.00 52 ST41896OOOO 6370 1 4.00 1.50 2.50 - 4.00 52 ST41911OOOO 7310 1
6.30 2.20 4.00 - 6.30 81.9 ST41897OOOO 6370 1 6.30 2.20 4.00 - 6.30 81.9 ST41912OOOO 7375 1
10.00 4.00 6.30 - 10.00 130 ST41898OOOO 6795 1 10.00 4.00 6.30 - 10.00 130 ST41913OOOO 7860 1
13.00 5.40 9.00 - 13.00 169 ST41899OOOO 7645 1 13.00 5.40 9.00 - 13.00 169 ST41914OOOO 8715 1
16.00 7.50 11.00 - 16.00 208 ST41900OOOO 8370 1 16.00 7.50 11.00 - 16.00 208 ST41915OOOO 9375 1
20.00 9.00 14.00 - 20.00 260 ST41901OOOO 8790 1 20.00 9.00 14.00 - 20.00 260 ST41916OOOO 10105 1
25.00 12.50 19.00 - 25.00 325 ST41902OOOO 9235 1 25.00 12.50 19.00 - 25.00 325 ST41917OOOO 10505 1
32.00 15.00 24.00 - 32.00 416 ST41903OOOO 16405 1 32.00 15.00 24.00 - 32.00 416 ST41918OOOO 17030 1
Note: Extended rotary handle cannot be fitted with MOG - S1
Lauritz Knudsen, 15.08.2026 21PDF page 29 Manual Motor Starters [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Manual Motor Starters [8536]
Type MOG-H1M (Rotary Type) - Frame 1 Type MOG-H2 (Rotary Type) - Frame 2
With short circuit protection only With short circuit & overload protection
Recommended Thermal M.R.P. Std.
Rating Motor Rating Instantaneous
Recommended Release (`)
Std. Trip Cat. No. Pkg.
Rating Motor Rating Instantaneous M.R.P. (A) at 415V, 3-Ph, range Per (Nos.)
Trip Cat. No. (`) Pkg. Current
(A) at 415V, 3-Ph, 50Hz (KW) (A) Unit
Current Per Unit (Nos.)
50Hz (KW) 32.00 15.00 24.00 - 32.00 416 ST41919OOOO 20700 1
0.16 - 2.1 ST41923OOOO 5785 1 40.00 20.00 28.00 - 40.00 520 ST41920OOOO 22825 1
0.25 0.06 3.3 ST41924OOOO 5785 1 50.00 25.00 35.00 - 50.00 650 ST41921OOOO 28495 1
0.40 0.09 5.2 ST41925OOOO 5785 1 63.00 34.00 45.00 - 63.00 819 ST41922OOOO 28915 1
0.63 0.12 8.2 ST41926OOOO 6545 1
1.00 0.25 13 ST41927OOOO 6670 1 Type MOG-H2M (Rotary Type) - Frame 2
1.60 0.55 20.8 ST41928OOOO 6670 1
With short circuit protection only
2.50 0.75 32.5 ST41929OOOO 6715 1
4.00 1.50 52 ST41930OOOO 6790 1
6.30 2.20 81.9 ST41931OOOO 6790 1
10.00 4.00 130 ST41932OOOO 7010 1
13.00 5.40 169 ST41933OOOO 7320 1
16.00 7.50 208 ST41934OOOO 7320 1 Recommended
M.R.P. Std.
20.00 9.00 260 ST41935OOOO 7685 1 Rating Motor Rating Instantaneous
Trip Cat. No. (`) Pkg.
25.00 12.50 325 ST41936OOOO 7920 (A) at 415V, 3-Ph,
1 Current Per Unit (Nos.)
50Hz (KW)
32.00 15.00 416 ST41937OOOO 12580 1
32.00 15.00 416 ST41938OOOO 19845 1
40.00 20.00 520 ST41939OOOO 19985 1
50.00 25.00 650 ST41940OOOO 20550 1
Accessories for MOG [8538] 63.00 34.00 819 ST41941OOOO 20980 1
Short Circuit Auxiliary + Alarm Extended Shunt Trip
Alarm Rotary Handle MMSs with bus bar Connecting 3 Phase Feed
connection Busbar link in terminal
Mounting M.R.P. Std. M.R.P. Std.
Position* Description Cat. No. (`) Pkg. Description Cat. No. (`) Pkg.
Per Unit (Nos.) Per Unit (Nos.)
Connecting Busbar link
F1/F2 Auxiliary Contact Front mtg. 1NO ST41942OOOO 1000 10
F1/F2 Auxiliary Contact Front mtg. 1NC ST41943OOOO 1000 10 2 MMS 45 mm width w/o acc ST41957OOOO 1150 5
L Auxiliary Contact Left side mtg. 2NO ST41944OOOO 1375 1 3 MMS 45 mm width w/o acc ST41958OOOO 1265 5
Auxiliary Contact Left side mtg. 4 MMS 45 mm width w/o acc ST41959OOOO 1370 5
L ST41945OOOO 1375 1 5 MMS 45 mm width w/o acc ST41960OOOO 1745 5
1NO + 1NC
L Auxiliary Contact Left side mtg. 2NC ST41946OOOO 1375 1 2 MMS 45 mm width with one acc 9 mm ST41961OOOO 1345 5
F2 Trip Alarm Contact Front mtg. 1NO ST41947OOOO 1780 10 3 MMS 45 mm width with one acc 9 mm ST41962OOOO 1450 5
F2 Trip Alarm Contact Front mtg. 1NC ST41948OOOO 1780 10 4 MMS 45 mm width with one acc 9 mm ST41963OOOO 1560 5
L Auxiliary + Alarm Left side mtg. 2NO ST41949OOOO 1890 1 5 MMS 45 mm width with one acc 9 mm ST41964OOOO 1665 5
Short circuit alarm Left side mtg. 2 MMS 55 mm width w/o acc ST41966OOOO 2100 1
L ST41950OOOO 1890 1 3 MMS 55 mm width w/o acc ST41967OOOO 2395 1
1NO + 1NC
R Shunt trip 24V DC ST41951OOOO 3635 1 4 MMS 55 mm width w/o acc ST41968OOOO 2870 1
R Shunt trip 110V, 50Hz ST41952OOOO 3825 1 2 MMS 55 mm width with one acc 9 mm ST41969OOOO 2285 1
R Shunt trip 230V, 50Hz ST42952OOOO 3825 1 3 MMS 55 mm width with one acc 9 mm ST41970OOOO 2605 1
R Under Voltage release, 110V, 50Hz ST41953OOOO 3825 1 4 MMS 55 mm width with one acc 9 mm ST41971OOOO 3060 1
R Under Voltage release, 415V, 50Hz ST41954OOOO 3825 1 2 MMS 55 mm width with two acc 18 mm ST41972OOOO 2675 1
External operating handle, 4 MMS 55 mm width with two acc 18 mm ST41973OOOO 2985 1
- ST41955OOOO 2205 1 Feed in terminal for 45 mm width Busbar ST41965OOOO 1345 1
(Black) Frame 1
External operating handle, Feed in terminal for 55 mm width Busbar ST41974OOOO 2320 1
- ST41956OOOO 2205 1 Bus bar safety cover 45 mm width Busbar ST41975OOOO 580 10
(Black) Frame 2
Bus bar safety cover 55 mm width Busbar ST41976OOOO 630 10
* F1- Front left slot F2- Front right slot L- Left side R- Right side
acc: Accessories
Lauritz Knudsen, 15.08.2026 22PDF page 30 Motor Starters [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Motor Starters [8536]
Direct-on-Line Starters Spares for MN Starters [8538]
in Sheet-Steel Enclosure Type MN / ML
(Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) M.R.P. Std.
Description Cat. No. (`) Pkg.
Per Unit (Nos.)
Bracket for Mounting cont. MNX 25 - 32 SS94030OOOO 320 20
MN DOL/FASD Push Button SS93941OOOO 550 10
MN 16 ML 1.5
Timers
Max. Motor Relay
Std.
Output at Max. Description M.R.P. (`)
Cat. No. Pkg.
415V, 3-Ph Range Per Unit
HP kW (A)
(Nos.) Electronic Timers Type ST100 [9107]
10.0 7.5 9 - 15 MN 16 DOL SS94351 9820 1
15.0 11.0 14 - 23 MN 25 DOL SS94352 14990 1
20.0 15.0 20 - 33 MN 32 DOL SS94353 24200 1
30.0 22.5 30 - 50 MN 45 DOL SS94017 41200 1
45.0 33.5 45 - 75 MN 65 DOL SS94018 56600 1
30.0 22.5 28 - 42 ML 3 DOL SS90722 53300 1
Fully Automatic Star-Delta Starters [8536]
in Sheet-Steel Enclosure Type MN / ML
(Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)
Max. Motor Relay
Std. ST 100
Output at Max. M.R.P. (`)
415V, 3-Ph Description Cat. No. Pkg.
Range Per Unit
(Nos.) M.R.P. Std
HP kW (A)
Description Cat. No. (`) Pkg.
17.5 13.0 9 - 15 MN 16 FASD SS94362 33100 1 Per Unit (Nos.)
240 / 360 / 415V, 50Hz for
30.0 22.5 14 - 23 MN 25 FASD SS94364 37000 1
3 - 30 secs. ST80328OOOO 2470 1
40.0 30.0 20 - 33 MN 32 FASD SS94366 60800 1
12 - 120 secs. ST80329OOOO 2470 1
50.0 37.5 30 - 50 MN 45 FASD SS94021 97500 1
Note:
75.0 55.0 45 - 75 MN 65 FASD SS94022 161800 1 ST 100 supplied with Mounting Kit, suitable for ET 100 replacement.
For Complete range of Timing Devices, please refer the Panel Accessories Price List.
90.0 67.5 45 - 75 MN 80 FASD SS94705 176700 1
150.0 110.0 66 - 110 MN 110 FASD SS94706 231400 1
180.0 132.0 90 - 150 MN 140 FASD SS94707 252800 1
50.0 37.5 28 - 42 ML3 FASD SS90730 128500 1
75.0 55.0 45 - 75 ML4 FASD SS90913 220000 1
125.0 90.0 66 - 110 ML6 FASD SS90923 361000 1
Ordering Suffix for ML & MN Starters
Coil Voltages Relay Range (A)
B - 240 V ML MN
C - 360 V A : 9 - 14 B : 9 - 15
D - 415 V B : 10 - 16 D : 14 - 23
P - 440 V C : 13 - 21 E : 20 - 33
E : 20 - 32 G : 30 - 50
F : 28 - 42 J : 45 - 75
G : 30 - 50 K : 66 - 110
J : 45 - 75 Q : 2 - 3.3
K : 66 - 110 S:3-5
M : 90 - 150 T : 36 - 60
P : 135 - 225 U : 4.5 - 7.5
Q : 180 - 310 V : 6 - 10
R : 2.5 - 4 M : 90 - 150
T : 13 - 21
Lauritz Knudsen, 15.08.2026 23PDF page 31 Selection as per Type 2 Co-ordination
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Selection as per Type 2 Co-ordination
All our Type 2 charts are available on Knowledge Portal
Access E&A's Knowledge Portal from
www.LK-EA.com/kp
Following combination of Type 2 Charts available
Fuse Based Charts Fuseless Charts
IE2/IE3 IE2/IE3 IE2 IE2 IE3 IE3
DOL SD DOL SD DOL SD
FN FN MMS/MCCB MMS/MCCB MMS/MCCB MMS/MCCB
MNX/MO MNX/MO MNX/MO MNX/MO MNX/MO MNX/MO
Charts available at Iq of
› 50kA
› 65kA
› 80kA
› 100kA
MCCB charts are available with
Microprocessor Releases too
Lauritz Knudsen, 15.08.2026 24PDF page 32 ©2026. All Rights Reserved.
Extracted reference text; use the original PDF to check column alignment, variants and price units.
©2026. All Rights Reserved.
PDF page 33 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 34 M.R.P. (`) Std. Pkg.
Extracted reference text; use the original PDF to check column alignment, variants and price units.
M.R.P. (`) Std. Pkg.
Description Type Cat. No.
Per Unit (Nos.)
Integrated ATS, Frame 2-125A 125A CK90161BATS 80000 1
Integrated ATS, Frame 2-160A 160A CK90162BATS 85000 1
Integrated ATS, Frame 2-200A 200A CK90163BATS 96100 1
Integrated ATS, Frame 3-250A 250A CK90164BATS 114600 1
Integrated ATS, Frame 3-315A 315A CK90165BATS 116500 1
Integrated ATS, Frame 4-400A 400A CK90166BATS 138600 1
Integrated ATS, Frame 4-630A 630A CK90167BATS 168200 1
Integrated ATS, Frame 5-800A 800A CK90169BATS 233370 1
Integrated ATS, Frame 5-1000A 1000A CK90170BATS 262500 1
Chapter ID [8536] Lauritz Knudsen, 15.08.2026 27PDF page 35 Enclosed Automatic Transfer Switch
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Enclosed Automatic Transfer Switch
Automatic Solution | Pre-wired | Flexible Settings
Switch to ATS
Now, experience seamless transfer between two power sources…
Convenience Flexibility
› Ample Space for Cable Termination › Priority Source Selection
› Ease of Generator Control › Adjustable Time Delay (0.1sec to 3 hours)
(ON-OFF, Cooling Cycle Self-Test) › Suitable for 3-Phase as well as 1-Phase Sources
› Cyclic Event Logger: Logs 100 Events
Performance Safety
› Wide range: 125A to 630A, 415V ac. › Protections: UV/OV, Phase Sequence,
› Double-Break Contact System offering High Single Phasing, Frequency
Short-time Withstand (Icw) › Authorized Access Control through Password
› High Mechanical and Electrical Life: Double than Protection
requirement of IS/IEC standard › Terminal Shrouds, Phase Barriers & Source Separator
› Suitable for Aluminum Termination
M.R.P. (`) Std. Pkg.
Description Type Cat. No.
Per Unit (Nos.)
Enclosed ATS, Frame 2, 125A 125A CK90161BSOO 105800 1
Enclosed ATS, Frame 2, 160A 160A CK90162BSOO 121220 1
Enclosed ATS, Frame 2, 200A 200A CK90163BSOO 126510 1
Enclosed ATS, Frame 3, 250A 250A CK90164BSOO 147350 1
Enclosed ATS, Frame 3, 315A 315A CK90165BSOO 154600 1
Enclosed ATS, Frame 4, 400A 400A CK90166BSOO 178910 1
Enclosed ATS, Frame 4, 630A 630A CK90167BSOO 217340 1
Chapter ID [8537]
For AuXC 2000 programming videos and Customer Interaction Center (CIC)
Phone no: 022-6932 7800
more details please scan the QR code
Web: www.LK-EA.com | e-mail: CIC@LK-EA.com
or click here
Lauritz Knudsen, 15.08.2026 28PDF page 36 On Load Changeover Switch - Disconnectors [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
On Load Changeover Switch - Disconnectors [8536]
Changeover Switch-Disconnector (Conforms to IEC 60947-3, IS/IEC 60947-3)
Features offered by Manual Changeover Features offered by Motorised Changeover
› Range 63A to 2000A, 415V, AC 23A, 4P › Range 40 A to 2000A, 415V, AC 23A, 4P
› Enclosure version does not require separate cable (Control Voltage 240 Vac )
gland box › No change in HxWxD dimension of motorised
› Terminal Shrouds, Source Separator and Phase and manual changeover switch
Barriers included › Padlocking in OFF position
› Staggered Terminals make cable termination easy › Option for selection between manual and
Open SS Motorised auto mode
› Suitable for horizontal as well as vertical mounting execution enclosure Changeover
Manual Changeover Manual Changeover Motorised Changeover
Open Execution In Sheet Steel Enclosure# Open Execution
Rated Std.
Size Current Type Pkg.
M.R.P. (`) M.R.P. (`) M.R.P. (`)
(A) Cat. No. Cat. No. Cat. No. (Nos.)
Per Unit Per Unit Per Unit
40 CO1-40 New CK90944BOOO 34240 1
63 CO1-63 CO10630OOOO 7870
CO10630OSOO 12650 New CK90945BOOO 35710 1
63 CO1-63 CO10630OOOD 7640
Fr 1
100 CO1-100 CO11000OOOO 9960
CO11000OSOO 14050 New CK90946BOOO 42060 1
100 CO1-100 CO11000OOOD 9470
125 CO1-125 CO11250OOOO 13130 CO11250OSOO 17400 New CK90947BOOO 44720 1
125 CO2-125 CO21250OOOO 16270 CO21250OSOO 24790 CK90161BOOO 60630 1
Fr 2 160 CO2-160 CO21600OOOO 17840 CO21600OSOO 26060 CK90162BOOO 75470 1
200 CO2-200 CO22000OOOA 20990 CO22000OSOO 29970 CK90163BOOO 82290 1
250 CO3-250 CO32500OOOO 30350 CO32500OSOO 41430 CK90164BOOO 99530 1
Fr 3
315 CO3-315 CO33150OOOO 33250 CO33150OSOO 43590 CK90165BOOO 104150 1
400 CO4-400 CO44000OOOO 47070 CO44000OSOO 57810 CK90166BOOO 135860 1
Fr 4
630 CO4-630 CO46300OOOO 59950 CO46300OSOO 77090 CK90167BOOO 171070 1
630 CO5-630 CO56300OOOO 73070 - - CK90168BOOO 177690 1
Fr 5 800 CO5-800 CO58000OOOO 79100 CO58000OSOO 147250 CK90169BOOO 248450 1
1000 CO5-1000 CO51000OOOO 175400 CO51000OSOO 224490 CK90170BOOO 325770 1
1250 CO6-1250 CO61250OOOO 212300 - - CK90081BOOO 368300 1
Fr 6 1600 CO6-1600 CO61600OOOO 266530 - - CK90082BOOO 452100 1
2000 CO6-2000 CO62000OOOO 372380 - - CK90083BOOO 558610 1
Direct handle version # Sheet Steel Enclosure version is with CO with extended handle
Note: Changeovers will be without inbuilt Aux contact and same to be purchased separately
as an accessories if required.
Spares & Accessories for Automatic Transfer Controllers (ATC) for
Changeover S-D [8538] Motorised Changeover [8538]
Auxiliary Operating Handle Flip-able Handle Castell AST Controller with AuXC-2000 Controller Illuminated Push
Contact (63A to 200A) (250A to 2000A) Type Lock wire harness with wire harness Button assembly
M.R.P. Std. M.R.P. Std.
Description Type Cat. No. (`) Pkg. Description Type Cat. No.
(`) Pkg.
Per Unit (Nos.) Per Unit (Nos.)
CO1-(63-125A) CX10002OOOO 770 1 Automatic AST Controller with wire harness CK90192OOOO 29620 1
Transfer β
CO2-(125-200A) CX20002OOOO 1310 1 Controllers AuXC-2000 Controller** AuXC-2000 ATC2000OOOO 52600 1
Auxiliary with wire harness wire harness CK90099OOOO 1
CO3-(250-315A) CX30002OOOO 1860 6040
Contact Kit 1
(2 sets of Control Illuminated Push Button
CO4-(400-630A) CX40002OOOO 1970 1 CK90195OOOO 6030 1
C/O contact) Accessories assembly with Wire harness
CO5-(630-1000A) CX50002OOOO 2290 1
β Chapter ID [9032]
CO6-(1250-2000A) CX60002OOOO 2500 1 ** Note: For communication version of AuXC controller refer page no-6
CO1-(63-125A) CX10001OOOO 1170 1 *** For CO6, the kit will have only operating handle.
Operating
Handle Kit CO2-(125-200A) CX30001OOOO 2460 1
(handle +
shaft + CO3-(250-315A) CK90392OOOO 2530 1
center bush + CO4-(400-630A) CX40001OOOO 2570 1
bush clip)
CO5-(630-1000A) CX50001OOOO 2780 1
CO6-(1250-2000A)*** CX60001OOOO 3160 1
Castell Type CO-(125-1000A) CX40004OOOO 4370 1
Lock $ CO6-(1250-2000A) CX60004OOOO 4180 1
Output CO1-(63-125A) Top Side CX10005OOOT 1220 1
shorting link
CO1-(63-125A) Bottom Side CX10005OOOB 1440 1
C/O Frame 1 (40-125A) CK90937OOOO 1650 1
Operating
Handle C/O Frame 2 & 3 (125-315A) CK90374OOOO 2210 1
for Motorised C/O Frame 4 & 5 (400-1000A) CK90378OOOO 2780 1
Changeover
C/O Frame 6 (1250-2000A CK90645OOOO 6910 1
$ Chapter ID [8301] Lauritz Knudsen, 15.08.2026 29PDF page 37 CZ Bypass Switches
Extracted reference text; use the original PDF to check column alignment, variants and price units.
CZ Bypass Switches
125A to 630A
Bypass Switches are meant for special application and help to maintain continuity of power supply to the load by
simply ‘bypassing’ UPS or Servo stabilizer. Removal of the UPS or Servo, for maintenance or repair is safe, as it is
isolated from both input and output sides in the ‘bypass’ mode.
Time-Saving Convenient solution Phase Barriers
No hassle of operating multiple devices for safe and Easy to fit and long phase barriers for
positive isolation on both sides of Servo/UPS complete isolation between phases
Suitable for Aluminum Termination Safety interlock and padlocking
Entire range is suitable for Aluminum cable/link Door interlock is provided in ON position with defeat
termination as per the size prescribed by the feature Also, Bypass Switch can be padlocked in
standards OFF position; upto 3 padlocks can be fitted
Mounting flexibility Finger proof protection (IP30)
Suitable for mounting in horizontal as well as Terminal Shrouds provide protection against
vertical orientation. Also, the shaft is ‘cut-able’ and accidental contact with live terminals.
can be adjusted to suit different panel depth As it is swivellable, there is no need to remove
requirements. during termination/inspection
4P, Open Execution with extended handle Accessories for CZ Bypass switch
Rating Std. Std.
M.R.P. (`) M.R.P. (`)
Frame 440Vac, Cat No. Pkg. Frame Description Cat No. Pkg.
Per Unit Per Unit
AC 23A (Nos.) (Nos.)
CZ1 125A CK90813OOOO 30650 1 Auxiliary
CZ1/
Contact Kit* CK90805OOOO 735 1
CZ1 160A CK90814OOOO 31930 1 CZ2 (1 C/O contact)
CZ1 200A CK90815OOOO 33760 1
Chapter ID [8538]
CZ1 250A CK90816OOOO 44860 1 * Upto 2 C/O contacts can be installed for status / indication
CZ1 315A CK90817OOOO 50250 1
CZ2 315A CK90875OOOO 55530 1
CZ2 400A CK90876OOOO 67750 1 Customer Interaction Center (CIC)
Phone no: 022-6932 7800
CZ2 630A CK90877OOOO 82210 1 Web: www.LK-EA.com | e-mail: CIC@LK-EA.com
Chapter ID [8536]
Lauritz Knudsen, 15.08.2026 30PDF page 38 Multiple Applications, One Solution
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Multiple Applications, One Solution
CZ Switch Disconnectors
› Compact 2P, 3P & 4P configurations › Extra assurance with visible contact system
› 1250Vac Insulation Voltage › High electrical and mechanical life
› AC-23A @ 690Vac without derating (double than requirement in IS/IEC standards)
› Suitable for 50OC ambient temperature › Terminal shrouds and phase barriers are provided as
› Direct termination without the need of standard offering along with the product
any extended links › Higher ground clearance ensure safety at all times
Versions: Upto 690V
4P AC Switch Disconnector 4P AC Switch Disconnector in SS enclosure (with extended handle)
Rating Upto M.R.P. (`) Std. Pkg. Rating Upto M.R.P. (`) Std. Pkg.
Frame Handle Type CAT No. Frame CAT No.
690V, AC 23A Per Unit (Nos.) 690V, AC 23A Per Unit (Nos.)
CZ1 125A Extended CK90769OOOO 9900 1 CZ1 125A CK90819OOOO 20400 1
CZ1 160A Extended CK90770OOOO 13100 1 CZ1 160A CK90820OOOO 23600 1
CZ1 200A Extended CK90771OOOO 15200 1 CZ1 200A CK90821OOOO 26600 1
CZ1 250A Extended CK90772OOOO 17100 1 CZ1 250A CK90822OOOO 30500 1
CZ1 315A Extended CK90773OOOO 19400 1 CZ1 315A CK90823OOOO 32200 1
CZ2 315A Extended CK90857OOOO 20200 1 CZ2 315A CK90878OOOO 38400 1
CZ2 400A Extended CK90858OOOO 25300 1 CZ2 400A CK90879OOOO 44500 1
CZ2 630A Extended CK90859OOOO 33900 1 CZ2 630A CK90880OOOO 52100 1
CZ1 125A Direct CK90799OOOO 9590 1 Chapter ID [8536]
CZ1 160A Direct CK90800OOOO 12500 1
Accessories for CZ Switch Disconnector
CZ1 200A Direct CK90801OOOO 14500 1
Description M.R.P. (`) Std. Pkg.
CZ1 250A Direct CK90802OOOO 16300 1 Frame CAT No.
Per Unit (Nos.)
CZ1 315A Direct CK90803OOOO 17200 1 Auxiliary
CZ1/CZ2 Contact Kit CK90805OOOO 735 1
CZ2 315A Direct CK90872OOOO 19100 1
(1 C/O contact)
CZ2 400A Direct CK90873OOOO 24500 1
Extended
C Z1 CK90740OOOO 1535 1
CZ2 630A Direct CK90874OOOO 30800 1 Handle
Chapter ID [8536]
Extended
C Z2 CK90842OOOO 1765 1
Handle
Chapter ID [8538]
Notes:
› 2P and 3P versions are also available. Please contact our nearest
branch office for further details
› Please refer next page for details on offerings for Solar applications
Customer Interaction Center (CIC)
Phone no: 022-6932 7800
Web: www.LK-EA.com | e-mail: CIC@LK-EA.com
Lauritz Knudsen, 15.08.2026 31PDF page 39 CZ Switch Disconnectors - For Solar/PV Application
Extracted reference text; use the original PDF to check column alignment, variants and price units.
CZ Switch Disconnectors - For Solar/PV Application
› Designed for tough conditions at solar sites
› Separate versions for 800Vac string inverter systems and upto 1500Vdc for central inverter systems
› Suitable for Aluminum termination of double the size recommended by IEC standards
› 1250Vac Rated Insulation Voltage
› Direct termination without the need of any extended links
› Terminal shrouds and phase barriers are provided as standard offering along with CZ AC Isolator
Versions: 800Vac I 1000Vdc I 1500Vdc
AC SD 800Vac, 3P Switch Disconnectors
› Operational Voltage upto 800Vac M.R.P. (`)
Frame Rating Handle Type Cat. No.
Per Unit
CZ2 400A Direct CK90852OOOO *
800Vac, 3P Switch Disconnectors CZ2 630A Direct CK90853OOOO *
CZ1 125A Extended CK90763OOOO *
M.R.P. (`)
Frame Rating Handle Type Cat. No.
Per Unit CZ1 160A Extended CK90764OOOO *
CZ1 125A Direct CK90757OOOO CZ1 200A Extended CK90765OOOO *
*
CZ1 160A Direct CK90758OOOO CZ1 250A Extended CK90766OOOO *
*
CZ1 200A Direct CK90759OOOO CZ1 315A Extended CK90767OOOO *
*
CZ1 250A Direct CK90760OOOO CZ2 315A Extended CK90854OOOO *
*
CZ1 315A Direct CK90761OOOO CZ2 400A Extended CK90855OOOO *
*
CZ2 315A Direct CK90851OOOO CZ2 630A Extended CK90856OOOO *
*
Chapter ID [8536]
DC Switch Disconnectors
DC SD
No. of Description M.R.P. (`)
Frame Rating Voltage Cat. No.
› Operational Voltage 1000Vdc & 1500Vdc Poles Per Unit
CZ2 315A 1500Vdc 2 Direct Handle, Side operated CK91157OOOO *
DC Switch Disconnectors CZ2 400A 1500Vdc 2 Direct Handle, Side operated CK91158OOOO *
CZ2 500A 1500Vdc 2 Direct Handle, Side operated CK91159OOOO *
No. of Description M.R.P. (`)
Frame Rating Voltage Cat. No. CZ2 630A 1500Vdc 2 Direct Handle, Side operated CK91160OOOO *
Poles Per Unit
CZ1 125A 1000Vdc 2 Direct Handle, Side operated CK90793OOOO * CZ2 315A 1500Vdc 2 Direct Handle, Center operated CK91161OOOO *
CZ1 160A 1000Vdc 2 Direct Handle, Side operated CK90794OOOO * CZ2 400A 1500Vdc 2 Direct Handle, Center operated CK91162OOOO *
CZ1 200A 1000Vdc 2 Direct Handle, Side operated CK90795OOOO * CZ2 500A 1500Vdc 2 Direct Handle, Center operated CK91163OOOO *
CZ1 250A 1000Vdc 2 Direct Handle, Side operated CK90796OOOO * CZ2 630A 1500Vdc 2 Direct Handle, Center operated CK91164OOOO *
CZ1 315A 1000Vdc 2 Direct Handle, Side operated CK90797OOOO * CZ2 315A 1500Vdc 2 Extended Handle, Side operated CK91165OOOO *
CZ2 315A 1000Vdc 2 Direct Handle, Side operated CK90869OOOO * CZ2 400A 1500Vdc 2 Extended Handle, Side operated CK91166OOOO *
CZ2 400A 1000Vdc 2 Direct Handle, Side operated CK90870OOOO * CZ2 500A 1500Vdc 2 Extended Handle, Side operated CK91167OOOO *
CZ2 630A 1000Vdc 2 Direct Handle, Side operated CK90871OOOO * CZ2 630A 1500Vdc 2 Extended Handle, Side operated CK91168OOOO *
CZ0 16A 1500 Vdc 4 Direct Handle, Center operated CK91314OOOO * CZ2 315A 1500Vdc 2 Extended Handle, Center operated CK91169OOOO *
CZ0 25A 1500 Vdc 4 Direct Handle, Center operated CK91315OOOO * CZ2 400A 1500Vdc 2 Extended Handle, Center operated CK91170OOOO *
CZ0 32A 1500 Vdc 4 Direct Handle, Center operated CK91316OOOO * CZ2 500A 1500Vdc 2 Extended Handle, Center operated CK91171OOOO *
CZ0 40A 1500 Vdc 4 Direct Handle, Center operated CK91317OOOO * CZ2 630A 1500Vdc 2 Extended Handle, Center operated CK91172OOOO *
CZ1 125A 1500Vdc 2 Direct Handle, Side operated CK90787OOOO * CZ2 315A 1500Vdc 4 Direct Handle, Center operated CK91177OOOO *
CZ1 160A 1500Vdc 2 Direct Handle, Side operated CK90788OOOO * CZ2 400A 1500Vdc 4 Direct Handle, Center operated CK91178OOOO *
CZ1 200A 1500Vdc 2 Direct Handle, Side operated CK90789OOOO * CZ2 500A 1500Vdc 4 Direct Handle, Center operated CK91179OOOO *
CZ1 250A 1500Vdc 2 Direct Handle, Side operated CK90790OOOO * CZ2 630A 1500Vdc 4 Direct Handle, Center operated CK91180OOOO *
CZ1 315A 1500Vdc 2 Direct Handle, Side operated CK90791OOOO * CZ2 315A 1500Vdc 4 Extended Handle, Center operated CK91185OOOO *
CZ2 315A 1500Vdc 3 Direct Handle, Side operated CK90866OOOO * CZ2 400A 1500Vdc 4 Extended Handle, Center operated CK91186OOOO *
CZ2 400A 1500Vdc 3 Direct Handle, Side operated CK90867OOOO * CZ2 500A 1500Vdc 4 Extended Handle, Center operated CK91187OOOO *
CZ2 630A 1500Vdc 3 Direct Handle, Side operated CK90868OOOO * CZ2 630A 1500Vdc 4 Extended Handle, Center operated CK91188OOOO *
Chapter ID [8536] Chapter ID [8536]
*Available on Request *Available on Request
Note: CZ1 & CZ2 DC will be without inbuild terminal shroud & same to be purchased separately as an accessory if required
M.R.P. (`) Std. Pkg.
Frame Description Cat. No.
Per Unit (Nos.)
CZ2 DC 2P Terminal Shroud CK50191OOOO 1000 1
CZ2 DC 4P Terminal Shroud CK50072OOOO 1100 1
CZ1 DC 2P Terminal Shroud CK50060OOOO 700 1
Chapter ID [8538]
Customer Interaction Center (CIC)
Phone no: 022-6932 7800
Lauritz Knudsen, 15.08.2026 32
Web: www.LK-EA.com | e-mail: CIC@LK-EA.comPDF page 40 New
Extracted reference text; use the original PDF to check column alignment, variants and price units.
New
gPV Fuses [8536]
Features offered by Photovoltaic Fuse, gPV
› Conforms to IEC 60269-6
› Range: 2A to 32A, 1000V, DC
› Range: 2A to 32A, 1500V, DC
› High breaking capacity: 20kA
Cylindrical fuse links Type gPV 1000Vdc New
Rated Std.
M.R.P. (`)
Size Current Description Cat. No. Pkg.
Per Unit
(A) (Nos.)
2 PV10DC103802 145 12
3 PV10DC103803 145 12
4 PV10DC103804 145 12
5 PV10DC103805 145 12
6 PV10DC103806 145 12
8 PV10DC103808 145 12
10 1000Vdc Fuse size 10 x 38 Suitable for PV10DC103810 145 12
10 X 38
12 Fuse holder PV10DC1038FH PV10DC103812 145 12
15 PV10DC103815 255 12
16 PV10DC103816 255 12
gPV Fuse 20 PV10DC103820 255 12
25 PV10DC103825 345 12
30 PV10DC103830 370 12
32 PV10DC103832 370 12
Cylindrical fuse links Type gPV 1500Vdc New
Rated Std.
M.R.P. (`)
Size Current Description Cat. No. Pkg.
Per Unit
(A) (Nos.)
2 PV15DC108502 430 6
4 PV15DC108504 430 6
6 PV15DC108506 430 6
8 PV15DC108508 430 6
10 PV15DC108510 430 6
1000Vdc Fuse size 10 x 38 Suitable
10 X 85 15 PV15DC108515 430 6
for Fuse holder PV10DC1038FH
16 PV15DC108516 430 6
20 PV15DC108520 570 6
25 PV15DC108525 570 6
gPV Fuse PV15DC108530 715
30 6
32 PV15DC108532 715 6
New
Cylindrical fuse links + fuse holder Type gPV 1000Vdc
Rated Std.
M.R.P. (`)
Size Current Description Cat. No. Pkg.
Per Unit
(A) (Nos.)
20 PV10DC103820A 500 6
25 PV10DC103825A 500 6
10 X 38 Fuse + Fuse holder
30 PV10DC103830A 520 6
32 PV10DC103832A 570 6
Fuse + Fuse Holder
1000V DC
Cylindrical fuse links + fuse holder Type gPV 1500Vdc New
Rated Std.
M.R.P. (`)
Size Current Description Cat. No. Pkg.
Per Unit
(A) (Nos.)
20 PV15DC108520A 1140 6
25 PV15DC108525A 1140 6
10 X 85 Fuse + Fuse holder
Fuse + Fuse Holder 30 PV15DC108530A 1430 6
1500V DC 32 PV15DC108532A 1430 6
Lauritz Knudsen, 15.08.2026 33PDF page 41 Switch-Disconnector Units [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Switch-Disconnector Units [8536]
Type FN & C-Line Switch Disconnector (2P/TPN/4P)
Features offered by S-D
› Telescopic shaft for depth adjustment
› Range 32A to 2000A, 415V, AC 23A
› Flip-able handle 1000A and above
FN 2P S-D
› Conforms to IEC 60947-3, IS/IEC 60947-3
FN TPN S-D
› Door interlock & padlock facility
Rated Open Execution 2P S-D Std. Pkg. Open Execution TPN S-D * Std. Pkg.
Size
Current (A) Type Cat. No. (Nos.) Type Cat. No. (Nos.)
M.R.P. (`) Per Unit M.R.P. (`) Per Unit
32 FN 32 2P SK90418OOOO 3100 1 FN 32 TPN / 4P SK95541OOOO 3700 1
Fr 1
63 FN 63 2P SK90419OOOO 3560 1 FN 63 TPN / 4P SK95540OOOO 4420 1
100 FN 100 2P SK90420OOOO 6410 1 FN 100 TPN SK95571OOOO 7970 1
Fr 2
125 FN 125 2P SK90421OOOO 8030 1 FN 125 TPN SK95405OOOO 10000 1
200 FN 200 2P SK90450OOOO 13200 1 FN 200 TPN SK95607OOOO 15600 1
Fr 3
250 FN 250 2P SK90454OOOO 14700 1 FN 250 TPN SK95683OOOO 17900 1
315 FN 315 2P SK90465OOOO 19900 1 FN 315 TPN SK95609OOOO 21700 1
Fr 4
400 FN 400 2P SK90466OOOO 21000 1 FN 400 TPN SK95610OOOO 25100 1
630 FN 630 2P SK90467OOOO 33600 1 FN 630 TPN SK95611OOOO 39500 1
Fr 5 800 FN 800 2P SK90468OOOO 36100 1 FN 800 TPN SK95551OOOO 42400 1
1000 FN 1000 2P SK90469OOOO 46500 1 FN 1000 TPN SK95710OOOO 65300 1
1000 - - - - C-Line SD 1000 4P$ COS1000OO4O 79500 1
1250 - - - - C-Line SD 1250 4P$ COS1250OO4O 99100 1
Fr 6
1600 - - - - C-Line SD 1600 4P$ COS1600OO4O 126000 1
2000 - - - - C-Line SD 2000 4P$ COS2000OO4O 165200 1
$ For C-Line SD 3P (1000A to 2000A), please contact nearest branch office
* For Switched Neutral Pole in FN TPN S-D, order Switched Neutral Kit separately.
Refer ‘Spares & Accessories for type FN’ table
Spares & Accessories for type FN [8538] * FN SDF and FN SD models are supplied without terminal shrouds
Handle Assembly Earthing Link Switched Neutral Kit Auxiliary Contact Kit Castell Type Lock
Description Type M.R.P. (`) Std. Pkg. Description Type M.R.P. (`) Std. Pkg.
Cat. No. Cat. No.
Per Unit (Nos.) Per Unit (Nos.)
FN 32 / 63 SK91302 840 1 A SK00333 4010 1
Auxiliary Contact Kit FN 100 / 125 / 160 SK91328 1020 1 FN 100 / 125 / B SK00334 4010 1
(1NO + 1 NC) FN 200 / 250 SK91329 1370 1 160 / 200 / 250 C SK00335 4010 1
FN 315 / 400 / 630 SK91330 1430 1 D SK00336 4010 1
Castell Type
FN 800/630(1) CK91034 # 1430 1 A SK00345# 4010 1
Lock$
2nd Aux. Contact FN 32 / 63 SK90670 910 1 FN 315 / 400 / B SK00346# 4010 1
(1NO + 1NC) 1050 630 / 800 C SK00347# 4010 1
FN 100 to FN 1000 SK90696 1
Earthing Link FN 32 to FN 1000 @
CK90396 840 1 D SK00348# 4010 1
FN 32 / 63 SK91257 800 1 FN 100 / 125 / 160 SK95233 7710 1
Handle Assembly - A FN 100 to FN 250 SK91258 1700 1 Switched Neutral FN 200 / 250 SK95516 8210 1
FN 315 / 400 / 630 / 800 SK91259# 1880 Kit FN 315 / 400 SK95517 8870 1
1
FN 32 / 63 SK91277 800 1 FN 630 / 800 SK95546# 12290 1
Handle Assembly - B FN 100 to FN 250 SK91278 1700 1
@For terminating earth busbar upto 25mm width. Order Qty 1 for 10 earthing links
FN 315 / 400 / 630 / 800 SK91279# 1880 1 (1)
FN 630 units manufactured from Dec-2025: Use Auxiliary Contact CK91034.
FN 630 units manufactured before Dec-2025: Use Auxiliary Contact Sk91330.
Handle Assembly - CE FN 32 / 63 SK91337 470 1
FN 200 SK91343 720 1
Interphase Barrier
FN 315 / 400 SK91344 760 1
Kit
FN 630 / 800 SK91345# 780 1
Spares & Accessories for type COS
Switch-Disconnector [8538]
Fuse pulling
handle [8538] For Type HN fuse-link For Type HF fuse-link Type Cat. No.
M.R.P. (`) Std. Pkg.
Per Unit (Nos.)
Description M.R.P. (`) Std. Pkg.
Cat. No. Auxiliary Contact Kit
Per Unit (Nos.)
(1 sets of C/O contact) CXS6002 1410 1
Fuse pulling handle for
SK91185 340 1 Operating Handle CXS6001 3020 1
HF Fuse-link from 2A-63A
Castell Type Lock$ CX60004 4010 1
Insulated fuse pulling handle for
SF90126 1170 1 $ Chapter ID [8301] # Also suitable for Switch-Disconnector FN 1000
Type HN fuse-link from 63A-800A
Notes: 1) Add suffix "OOOO" to all cat nos. of Spares and Accessories.
Lauritz Knudsen, 15.08.2026 34PDF page 42 Switch-Disconnector-Fuse Units [8537]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Switch-Disconnector-Fuse Units [8537]
Type TPN S-D-F suitable for
DIN fuse-link (TPN & FP) in open execution
Features offered by FN S-D-F
in-built
› Range 32A to 800A, 415V, AC 23A Neutral Link
› Conforms to IEC 60947-3, IS/IEC 60947-3
› Phase Barriers included
› Telescopic shaft for depth adjustment
› TPN SDF has isolable neutral
› 4P SDF has Switched Neutral Pole and is 100% rated
› Door interlock & padlock facility FN - TPN S-D-F FN - 4P S-D-F
(Open Execution) (Open Execution)
Open Execution Type FN (TPN) S-D-F Open Execution Type FN S-D-F
Suitable HRC fuse-link
Rated suitable for DIN fuse-link Std. suitable for DIN fuse-link (4P) Std.
Size Current Range M.R.P. Pkg. M.R.P. Pkg.
(A) Type Type Cat. No. (`) (Nos.) Type Cat. No. (`) (Nos.)
(A)
Per Unit Per Unit
32 HF Size 14x51 2 to 32 FN 32 TPN / FP SK95518 3740 1 FN 32 TPN/FP SK95518 3740 1
32 HF Size 14x51 2 to 32 FN 32 TPN / FP CE* SK95703* 3390 1 FN 32 TPN/FP CE* SK95703* 3390 1
Fr 1
63 HF Size 14x51 2 to 63 FN 63 TPN / FP SK95421 4930 1 FN 63 TPN/FP SK95421 4930 1
63 HF Size 14x51 2 to 63 FN 63 TPN / FP CE* SK95704* 4600 1 FN 63 TPN/FP CE* SK95704* 4600 1
New 100 HN Size 000 63 to 100 FN 100C TPN CK91079 7100 1 - - - -
100 HN Size 000/00 63 to 100 FN 100 TPN SK95568 9350 1 FN 100 FP SK90496 10700 1
Fr 2
125 HN Size 000/00 63 to 125 FN 125 TPN SK95001 12400 1 FN 125 FP SK90497 13300 1
160 HN Size 000/00 63 to 160 FN 160 TPN SK95713 13300 1 FN 160 FP SK90498 15000 1
200 HN Size 0 80 to 200 FN 200 TPN SK95418 18100 1 FN 200 FP SK90471 21400 1
Fr 3
250 HN Size 1 125 to 250 FN 250 TPN SK95642 20500 1 FN 250 FP SK90472 24300 1
315 HN Size 1 125 to 315 FN 315 TPN SK95461 25600 1 FN 315 FP SK90473 29400 1
Fr 4
400 HN Size 2 200 to 400 FN 400 TPN SK95481 30700 1 FN 400 FP SK90480 33400 1
630 HN Size 3 315 to 630 FN 630 TPN SK95521 52500 1 FN 630 FP SK90481 56200 1
Fr 5
800 HN Size 3 315 to 800 FN 800 TPN SK95679 92300 1 FN 800 FP SK90482 109400 1
* ‘CE’ handle has door interlock facility without defeat feature
* FN SDF and FN SD models are supplied without terminal shrouds
New
FN S-D-F With Fuse Cover [8537]
Terminal Shroud Fuse Cover FN Switch =
New
Spares & Accessories for type FN [8538]
Description Type M.R.P. (`) Std. Pkg. Description Type M.R.P. (`) Std. Pkg.
Cat. No. Cat. No.
Per Unit (Nos.) Per Unit (Nos.)
FN 32/63 CK91321 250 1 FN 100/125/160 CK91326 575 1
FN 100/125/160 CK91322 750 1 FN 200/250 CK91327 1080 1
Fuse Cover Kit Fuse Cover Kit for 4P
FN 200/250 CK91323 1000 1 FN 315/400 CK91328 1210 1
for 3P/TPN
FN 315/400 CK91324 1125 1 FN 630/800 CK91329 1355 1
FN 630/800 CK91325 1250 1 FN 100/125/160 CK91334 400 1
FN 32/63 SK91190 290 1 Terminal Shroud Kit FN 200/250 CK91335 1060 1
FN 100/125/160 SK91137 360 1 4P FN 315/400 CK91336 1100 1
Terminal Shroud Kit
FN 200/250 SK91335 1030 1 FN 630/800 CK91337 1200 1
3P/TPN
FN 315/400 SK91346 1050 1
FN 630/800 SK91347 1110 1
Lauritz Knudsen, 15.08.2026 35PDF page 43 HRC Fuses [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
HRC Fuses [8536]
Features offered by HRC Cylindrical fuse links Type HF
fuse link
Rated Std.
› Conforms to IEC 60269-2, M.R.P. (`)
Pkg.
Size Current Description Cat. No.
IS 13703 part 2 Per Unit
(A) (Nos.)
› Range: 2A to 800A, 415V, 2 SF93802 110 12
AC 50Hz 4 SF93804 110 12
› Type: Cylindrical (2A to 6 SF93806 110 12
63A), DIN (63A to 800A) & New 10 Suitable for Type SF93810 110 12
Bolted (2A to 630A) 10 X 38 for Fuse Holder
16 SF93816 110 12
› High breaking capacity: 20
10 x 38 -SF93868
SF93820 110 12
100kA for type HN and 25 SF93825 110 12
80kA for type HF/HG/HQ 2 SF90144 245 30
4 SF90145 245 30
6 SF90146 245 30
8 Suitable for Type FN 32 / 63 / SF90147 245 30
10 FNX 32 / 63 S-D-F SF90148 245 30
HF 16 & for HCO 32 Fuse base SF90150 245 30
14 X 51
20 SF90151 245 30
25 SF90152 245 30
32 SF90142 245 30
40 SF90143 260 30
Suitable for Type FN 63 / FNX 63 S-D-F
50 SF90158 570 30
& for HC 63 Fuse base
63 SF90159 615 30
DIN Type Fuse Links Type HN
Rated Std.
Size M.R.P. (`)
Current Description Cat. No. Pkg.
Per Unit
(A) (Nos.)
63 SF94940 650 3
80 Suitable for Type SF94941 685 3
000 000 FN 100/125/160 / FNX 100/125/160 S-D-F
100 & for HB 160 Fuse base SF94942 695 3
125 SF94946 810 3
63 SF94027 855 3
80 SF94028 855 3
Suitable for Type
00 00 100 FN 100/125/160 / FNX 125/160 S-D-F SF94029 855 3
125 & for HB 160 Fuse base SF94030 865 3
160 SF94939 885 3
80 SF94128 1120 3
100 SF94129 1160 3
Suitable for Type
0 0 125 FN 200 / FNX 200 S-D-F SF94130 1160 3
160 & for HB 250 Fuse base SF94131 1170 3
200 SF94132 1210 3
125 SF94230 1130 3
160 Suitable for Type SF94231 1210 3
1 1 200 FN 250/315 / FNX 250/315 S-D-F SF94232 1210 3
250 & for HB 250 Fuse base SF94233 1360 3
315 SF94234 1730 3
200 SF94332 1720 3
250 Suitable for Type SF94333 1760 3
2 2 FN 400 / FNX 400 S-D-F
315 & for HB 800 Fuse base SF94334 1810 3
400 SF94335 1840 3
315 SF94434 2550 1
400 Suitable for Type SF94435 2700 1
3 3 500 FN 630/800 / FNX 630/800 S-D-F SF94436 2780 1
630 & for HB 800 Fuse base SF94437 2930 1
800 SF94938 3620 1
Fuse holders & Fuse bases suitable for Cylindrical / DIN fuse-links
Suitable fuse-link M.R.P. Std.
Rated
Type Description Cat. No. (`) Pkg.
Current (A) Type Range (A) Per Unit (Nos.)
New 32 HCM 32 Fuse holder HF(10x38) 2-25 SF93868 400 12
32 HCO 32 Fuse holder HF(14x51) 2-32 SK91314 455 10
63 HC 63 Fuse holder HF(14x51) 2-63 SK91043 520 10
160 HB 160 Fuse base HN-Size 000 & 00 63-160 SK90405 695 12
250 HB 250 Fuse base HN-Size 0 & 1 80-250 SK90406 1470 3
400 HB 400 Fuse base HN-Size 2 200-400 SK90717 2040 3
HCM HB HC 800 HB 800 Fuse base HN-Size 3 315-800 SK91051 2970 3
Notes : 1) Add suffix "OOOO" to all cat nos.
Lauritz Knudsen, 15.08.2026 36PDF page 44 Switch-Disconnector-Fuse Units [8537]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Switch-Disconnector-Fuse Units [8537]
Type FN S-D-F suitable for Type FN S-D-F suitable for
DIN fuse-link (2P) in open execution BS fuse-link (TPN) in open execution
Features offered by FN S-D-F
For BOLTED fuse-link
› Range 32A to 630A, 415V, Also for 220Vdc &
AC 23A 240Vac application Features offered by FN S-D-F
› Conforms to IEC 60947-3, › Range 32A to 630A, 415V, AC 23A
IS/IEC 60947-3 › Conforms to IEC 60947-3, IS/IEC 60947-3
› Phase Barriers included › Phase Barriers included
› Telescopic shaft for depth › Telescopic shaft for depth adjustment
adjustment › Door interlock & padlock facility
› Door interlock & padlock
facility
FN 2P S-D-F FN - TPN S-D-F
Type FN (2P) S-D-F suitable Type FN (2P) S-D-F suitable
for DIN fuse-link for DIN fuse-link
Size Rated Suitable Open Execution Size Rated Suitable Open Execution
Current fuse-link type Current fuse-link type
M.R.P. (`) Std. Pkg M.R.P. (`) Std. Pkg
(A) Type Cat. No. (A) Type Cat. No.
Per Unit (Nos.) Per Unit (Nos.)
32 HF Size 14x51 FN 32 2P SK95594 3210 1 32 A1L FN 32 TPN SK95653 3610 1
Fr 1 Fr 1
63 HF Size 14x51 FN 63 2P SK95595 4280 1 63 A1L FN 63 TPN SK95651 4880 1
100 HN Size 000/00 FN 100 2P ST35086 7360 1 100 A4 FN 100 TPN SK95570 9340 1
Fr 2 125 HN Size 000/00 FN 125 2P ST35087 10900 1 Fr 2 125 A4 FN 125 TPN SK95009 11900 1
160 HN Size 000/00 FN 160 2P ST35088 11400 1 160 A4 FN 160 TPN SK95714 12900 1
200 HN Size 0 FN 200 2P ST35089 14900 1 200 B1 / B2 FN 200 TPN SK95588 17200 1
Fr 3 Fr 3
250 HN Size 1 FN 250 2P ST31674 17200 1 250 B2 / B3 FN 250 TPN SK95682 20200 1
315 HN Size 1 FN 315 2P ST38930 21300 1 315 B3 FN 315 TPN SK95590 25100 1
Fr 4 Fr 4
400 HN Size 2 FN 400 2P ST31676 24000 1 400 B4 FN 400 TPN SK95591 30400 1
Fr 5 630 HN Size 3 FN 630 2P ST35090 41400 1 Fr 5 630 C2 FN 630 TPN SK95592 52300 1
* Add suffix "OOOO" to all cat nos.
* FN SDF and FN SD models are supplied without terminal shrouds
FN- TPN S-D-F in SS Enclosure Benefit of
Cable Gland Box 3 in 1
Features offered by FN S-D-F in SS Enclosure: Top
› Range 32A to 800A, 415V, AC 23A
Separate cable
› Spacious Sheet Steel Enclosure gland box
SDF in Enclosure
› Separate cable gland box not required NOT required
› Phase Barriers included
› Conforms to IEC 60947-3, IS/IEC 60947-3 Cable Gland Box
› Suitable for Cylindrical/DIN fuse-link Bottom
FN - TPN S-D-F in SS Enclosure
› Door interlock & padlock facility
In Sheet Steel Enclosure Type FN (TPN) S-D-F
Suitable HRC fuse-link
Rated suitable for DIN fuse-link Std.
Size Current Range Pkg.
Type Type M.R.P. (`)
(A) Cat. No. (Nos.)
(A) Per Unit
32 HF Size 14x51 2 to 32 FN 32 TPN / FP CE* SK90483* 8640 1
Fr 1
63 HF Size 14x51 2 to 63 FN 63 TPN / FP CE* SK90484* 10300 1
100 HN Size 000/00 63 to 100 FN 100 TPN SK90485 16700 1
Fr 2 125 HN Size 000/00 63 to 125 FN 125 TPN SK90486 18900 1
160 HN Size 000/00 63 to 160 FN 160 TPN SK90487 19800 1
200 HN Size 0 80 to 200 FN 200 TPN SK90488 28600 1
Fr 3
250 HN Size 1 125 to 250 FN 250 TPN SK90489 31500 1
315 HN Size 1 125 to 315 FN 315 TPN SK90490 36500 1
Fr 4
400 HN Size 2 200 to 400 FN 400 TPN SK90491 41100 1
630 HN Size 3 315 to 630 FN 630 TPN SK90492 64200 1
Fr 5
800 HN Size 3 315 to 800 FN 800 TPN SK90493 116800 1
* ‘CE’ handle has door interlock facility without defeat feature
Notes:
1) Type FN S-D-F range (Bolted fuse-link) suitable for harsh environment is also available. Please contact nearest branch office for further details
2) For 690V AC application, please contact nearest branch office
3) The prices for S-D-F range are without HRC fuses
4) The SDF units in SS enclosure version can be replaced with FN TPN SDF open execution units. Please refer point 5 for replacement of 250A unit
5) For replacement of FN 250 SDF unit in sheet steel enclosure version (Cat. No. SK90489OOOO & SK95681OOOO), order Cat. No. ST97895OOOO
6) Please refer Page 36 for Switch-Disconnectors
7) Add suffix "OOOO" to all cat nos. Lauritz Knudsen, 15.08.2026 37
8) FN SDF and FN SD models are supplied without terminal shroudsPDF page 45 HRC Fuses [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
HRC Fuses [8536]
Bolted fuse links: Type HG and HQ
Std.
Fixing Rating M.R.P. (`)
Type Size Description Cat. No. Pkg.
Method (A) Per Unit
F1 (Nos.)
2 ST30725 100 24
4 ST30726 100 24
6 ST30727 100 24
10 Suitable for type ST30728 100
Offset, 24
A2 HG F1 HD 20H/20P/20B,
staggered 16 ST30729 110 24
A1 L HD 32H/32P/32B fuse base
20 ST30730 110 24
25 ST30731 110 24
32 ST30732 110 24
20 ST34527 200 15
25 ST34528 200 15
Suitable for type
A1L 32 ST34529 200 15
FN 32/63 S-D-F
50 ST35827 245 15
A3
63 ST35828 245 15
A4 4 ST30747 170 12
6 ST30748 170 12
10 ST30749 170 12
Suitable for type
A2 16 ST30750 170 12
HK 32H/32B fuse base
Offset 20 ST30751 170 12
25 ST30752 170 12
32 ST30753 170 12
B1 35 ST30759 260 12
Suitable for type
A3 50 ST30760 280 12
HK 63B/63H Fuse base
63 ST30761 290 12
B2 80 ST30767 560 12
HQ Suitable for type
100 ST30768 560 12
A4 FN 100/125/160 S-D-F
125 & for HK 125H/125B Fuse base ST30769 625 12
160 ST35829 715 12
80 ST30774 625 12
B1 100 Suitable for type ST30775 625 12
FN 200 S-D-F
B3 125 ST30776 740 12
125 ST30777 760 3
B2 Suitable for type
Centre Tag, 160 ST30778 785 3
FN 200/250 S-D-F
2 holes 200 ST30779 850 3
C2 250 Suitable for type ST30781 1240 3
B3
315 FN 250/315 S-D-F ST30782 1310 3
355 Suitable for type ST30783 1840 3
B4
400 FN 400 S-D-F ST30784 1890 3
400 ST30785 3570 1
Centre Tag, Suitable for type
C2 500 ST30786 3770 1
4 holes FN 630 S-D-F
630 ST30787 4310 1
Fuse holders suitable for Bolted fuse-links
Rated Suitable M.R.P. Std.
Fuse
Current Type Connection Method Fuse Cat. No. (`) Pkg.
Type
(A) Range (A) Per Unit (Nos.)
HD 20H Both side cable (Front) F1 2-20 ST30772 365 12
20 HD 20P Both side busbar (Back) F1 2-20 ST30773 380 12
HD 20B Top busbar & bottom cable F1 2-20 ST30766 380 12
HD 32H Both side cable (Front) F1 2-32 ST30733 390 12
HK 125B HK 32H HD 20P HD 32P Both side busbar (Back) F1 2-32 ST30734 390 12
32
HD 32B Top busbar & bottom cable F1 2-32 ST30735 400 12
Rear View
HK 32H Both side cable (Front) A2 4-32 ST30754 485 12
HK 32B Top busbar & bottom cable A2 4-32 ST30755 485 12
HK 63H Both side cable (Front) A3 35-63 ST30762 690 6
63
HK 63B Top busbar & bottom cable A3 35-63 ST30763 690 6
HK 125H Both side cable (Front) A4 80-125 ST30770 1910 3
125
HK 125B Top busbar & bottom cable A4 80-125 ST30771 1910 3
HD 20B HD 20H HD 20P
Notes: 1) Add suffix "OOOO" to all cat nos.
HRC DIN FUSES (500 VAC)
FOR RAILWAY APPLICATIONS
For specifications, pricing, and ordering details, please contact your nearest branch office.
Lauritz Knudsen, 15.08.2026 38PDF page 46 DZ MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DZ MCCB Range [8536]
Contact System
› Double Break with low let-through energy
› High Breaking Capacity up to 200kA @ 415V AC Thermal - Magnetic Release
› 100kA @690V AC at 100% Ics › Extended Overload Setting of 67%
› 50kA @ 800V AC offering for Solar PV String inverters › 16A to 800A Offering
› 1000V/1500V PV DC Offering › Ambient Temperature Compensation
› Suitable for wide temperature range
Microprocessor Release
Mechanism › Extended Overload Setting of 25%
› Class II Front Facia › Individual Fault Indication LEDs
› Double Insulation › Battery Operated In-built Display
› Positive Isolation › Advanced Metering and Protection
› High Electrical and Mechanical Life › Motor Protection Variant with effective
Type 2 Coordination
Modular Architecture
› Compact Size Modules
› Late Personalization › Temperature Monitoring & Protection
› Interchangeability of Releases › Zone Selective Interlocking for effective Selectivity
› Reduced Inventory for internal accessories › Communication Module for metering & control
› Remote Operation for Motorized MCCB
› Breaker Status, Alarm & Trip with Records
FUTURE READY FOR COMPLIANCE AND NEW APPLICATIONSPDF page 47 DZ MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DZ MCCB Range [8536]
RESILIENT FOR BETTER SAFETY AND MAINTENANCE
Inventory & Application friendly Internal Accessories Robust Rotary & Electrically Operated Mechanisms
Direct Extended
Aux/TAC Shunt UVR ROM EOM
ROM
Reduced Downtime with Plug-in & Drawout Modules Shrouds for increased personnel safety
Short Long
Plug-in Draw-out Shroud Shroud
Multiple options for Mechanical Interlocking Versatile Range of Terminations
Front Cable Base Rear Base Direct Box Clamp Spreader Rear
Slider Plate Plate Termination Termination Termination Termination
CONNECTED TO DRIVE ENERGY EFFICIENCY
* Multiple Breakers
Internal BUS
Modbus RTU
AUX / TAC
Comm
Module
Data Analytics Trend Analysis
EOM
Real Time Monitoring Status & Control
Metering & Protection Data AcquisitionPDF page 48 DZ MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DZ MCCB Range [8536]
DZ With Thermal - Magnetic Release
Rating (A)
16 20 25 32 40 50 63 80 100 125 160 200 250 320 400 500 630 800
Icu=Ics (kA)*
25/36 DZ0
36/50 DZ1
36/50/80/120 DZ2
36/50/80/120/200 DZ4
36/50/80/120/200 DZ6 DZ7
› Conforms to IS/IEC 60947-2
› 16A to 125A, 3P & 4P
› 25kA & 36kA breaking capacities
› Ics= 100% of Icu*
› Adjustable overload settings: 0.8 - 1.0 x In
› Fixed short-circuit settings: 10 x In
› Compact size
› Manual and Rotary versions available
› Wide range of accessories
dsine-DZ0 TM
Overload Breaking 3 Pole 4 Pole
Std.
Release Capacity Icu
Type Pkg.
Range at 415V AC, Cat No M.R.P. (`) Cat No M.R.P. (`)
Per Unit Per Unit (Nos.)
(A) 50Hz. (kA)
13-16 DZ0T0016D5C1AOOOO 12400 DZ0F0016D5C1AOOOO 17400 1
16-20 DZ0T0020D5C1AOOOO 12400 DZ0F0020D5C1AOOOO 17400 1
20-25 DZ0T0025D5C1AOOOO 12400 DZ0F0025D5C1AOOOO 17400 1
26-32 DZ0T0032D5C1AOOOO 12400 DZ0F0032D5C1AOOOO 17400 1
32-40 DZ0T0040D5C1AOOOO 12400 DZ0F0040D5C1AOOOO 17400 1
DZ0-125D* 36kA
40-50 DZ0T0050D5C1AOOOO 12400 DZ0F0050D5C1AOOOO 17400 1
50-63 DZ0T0063D5C1AOOOO 12100 DZ0F0063D5C1AOOOO 16800 1
64-80 DZ0T0080D5C1AOOOO 12100 DZ0F0080D5C1AOOOO 16800 1
80-100 DZ0T0100D5C1AOOOO 12100 DZ0F0100D5C1AOOOO 16800 1
100-125 DZ0T0125D5C1AOOOO 15700 DZ0F0125D5C1AOOOO 21000 1
13-16 DZ0T0016CXC1AOOOO 12900 DZ0F0016CXC1AOOOO 18000 1
16-20 DZ0T0020CXC1AOOOO 12900 DZ0F0020CXC1AOOOO 18000 1
20-25 DZ0T0025CXC1AOOOO 12900 DZ0F0025CXC1AOOOO 18000 1
26-32 DZ0T0032CXC1AOOOO 12900 DZ0F0032CXC1AOOOO 18000 1
32-40 DZ0T0040CXC1AOOOO 12900 DZ0F0040CXC1AOOOO 18000 1
DZ0-125C 25kA
40-50 DZ0T0050CXC1AOOOO 12900 DZ0F0050CXC1AOOOO 18000 1
50-63 DZ0T0063CXC1AOOOO 12400 DZ0F0063CXC1AOOOO 17500 1
64-80 DZ0T0080CXC1AOOOO 12400 DZ0F0080CXC1AOOOO 17500 1
80-100 DZ0T0100CXC1AOOOO 12400 DZ0F0100CXC1AOOOO 17500 1
100-125 DZ0T0125CXC1AOOOO 17300 DZ0F0125CXC1AOOOO 21800 1
- Spreader Terminals are included
Note:
Breaking Capacity: C = 25kA, D = 36kA
*DZ0-125D : Ics= 50% Icu
Phase barriers are supplied with all MCCBs
Lauritz Knudsen, 15.08.2026 41PDF page 49 DZ MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DZ MCCB Range [8536]
DZ With Thermal - Magnetic Release
› Conforms to IS/IEC 60947-2
› 16A to 800A, 3P & 4P
› 36kA, 50kA, 80kA,120kA & 200kA breaking capacities
› Ics= 100% of Icu
› Adjustable overload settings: 0.67 - 1.0 x In
› Adjustable short-circuit settings: 6 - 12 x In*
› Transparent sealable release cover
› Ambient Temperature Compensation
› Compact size
dsine-DZ1 TM › Fixed, Plug-in, Drawout, Rotary and Motorised versions available
› Wide range of accessories
Overload Breaking 3 Pole 4 Pole
Std.
Release Capacity Icu
Type Pkg.
Range at 415V AC, Cat No M.R.P. (`) Cat No M.R.P. (`)
Per Unit Per Unit (Nos.)
(A) 50Hz. (kA)
11-16 DZ1T0016DXC1AOOOO 22200 DZ1F0016DXC1AOOOO 27600 1
14-20 DZ1T0020DXC1AOOOO 22200 DZ1F0020DXC1AOOOO 27600 1
17-25 DZ1T0025DXC1AOOOO 22200 DZ1F0025DXC1AOOOO 27600 1
22-32 DZ1T0032DXC1AOOOO 22200 DZ1F0032DXC1AOOOO 27600 1
27-40 DZ1T0040DXC1AOOOO 22200 DZ1F0040DXC1AOOOO 27600 1
DZ1-160D/
DZ1-200D 34-50 DZ1T0050DXC1AOOOO 22200 DZ1F0050DXC1AOOOO 27600 1
43-63 DZ1T0063DXD1AOOOO 21500 DZ1F0063DXD1AOOOO 26600 1
54-80 DZ1T0080DXD1AOOOO 21500 DZ1F0080DXD1AOOOO 26600 1
67-100 DZ1T0100DXD1AOOOO 21500 DZ1F0100DXD1AOOOO 26600 1
84-125 DZ1T0125DXD1AOOOO 24200 DZ1F0125DXD1AOOOO 29800 1
108-160 DZ1T0160DXD1AOOOO 31700 DZ1F0160DXD1AOOOO 37700 1
134-200 DZ1T0200DXD1AOOOO 48000 DZ1F0200DXD1AOOOO 57600 1
11-16 DZ2T0016DXC1AOOOO 22600 DZ2F0016DXC1AOOOO 28200 1
14-20 DZ2T0020DXC1AOOOO 22600 DZ2F0020DXC1AOOOO 28200 1
17-25 DZ2T0025DXC1AOOOO 22600 DZ2F0025DXC1AOOOO 28200 1
22-32 DZ2T0032DXC1AOOOO 22600 DZ2F0032DXC1AOOOO 28200 1
27-40 36kA DZ2T0040DXC1AOOOO 22600 DZ2F0040DXC1AOOOO 28200 1
34-50 DZ2T0050DXC1AOOOO 22600 DZ2F0050DXC1AOOOO 28200 1
DZ2-160D 43-63 DZ2T0063DXD1AOOOO 21800 DZ2F0063DXD1AOOOO 27300 1
54-80 DZ2T0080DXD1AOOOO 21800 DZ2F0080DXD1AOOOO 27300 1
67-100 DZ2T0100DXD1AOOOO 21800 DZ2F0100DXD1AOOOO 27300 1
84-125 DZ2T0125DXD1AOOOO 24500 DZ2F0125DXD1AOOOO 30400 1
108-160 DZ2T0160DXD1AOOOO 32100 DZ2F0160DXD1AOOOO 38300 1
108-160 DZ4T0160DXD1AOOOO 40600 DZ4F0160DXD1AOOOO 50000 1
DZ4-250D 134-200 DZ4T0200DXD1AOOOO 46500 DZ4F0200DXD1AOOOO 55900 1
168-250 DZ4T0250DXD1AOOOO 49000 DZ4F0250DXD1AOOOO 59000 1
134-200 DZ6T0200DXD1AOOOO 60500 DZ6F0200DXD1AOOOO 73900 1
168-250 DZ6T0250DXD1AOOOO 64900 DZ6F0250DXD1AOOOO 79300 1
DZ6-400D
215-320 DZ6T0320DXD1AOOOO 67200 DZ6F0320DXD1AOOOO 81900 1
268-400 DZ6T0400DXD1AOOOO 67200 DZ6F0400DXD1AOOOO 81900 1
335-500 DZ7T0500DXD1AOOOO 76800 DZ7F0500DXD1AOOOO 96800 1
DZ7-800D 422-630 DZ7T0630DXD1AOOOO 76800 DZ7F0630DXD1AOOOO 96800 1
536-800 DZ7T0800DXD1AOOOO 107000 DZ7F0800DXD1AOOOO 136200 1
- Spreader Terminals are included
Note:
Breaking Capacity: D = 36kA, N = 50kA, H = 80kA
dsine DZ-120kA & 200kA @415V (Ics=100% Icu) MCCBs are available on request.
It is recommended to use spreader terminals for enhancing termination capacity
For Motor back-up protection, use ‘M’ series of MCCBs such as DZ0-N, DZ1-N, DZ4-N, DZ6-N, DZ7-N
* For DZ1 & DZ2 - 16A to 50A, Fixed Magnetic setting (375A)
For DZ7 630A / 800A, Magnetic setting from 6 In to 10 In / 6 In to 8 In respectively
Lauritz Knudsen, 15.08.2026 42PDF page 50 DZ MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DZ MCCB Range [8536]
Overload Breaking Capacity 3 Pole 4 Pole Std.
Type Release Range Icu at 415V AC, Pkg.
(A) 50Hz. (kA) Cat No M.R.P.(`) Per Unit Cat No M.R.P.(`) Per Unit (Nos.)
11-16 DZ1T0016NXC1AOOOO 26200 DZ1F0016NXC1AOOOO 31500 1
14-20 DZ1T0020NXC1AOOOO 26200 DZ1F0020NXC1AOOOO 31500 1
17-25 DZ1T0025NXC1AOOOO 26200 DZ1F0025NXC1AOOOO 31500 1
22-32 DZ1T0032NXC1AOOOO 26200 DZ1F0032NXC1AOOOO 31500 1
27-40 DZ1T0040NXC1AOOOO 26200 DZ1F0040NXC1AOOOO 31500 1
34-50 DZ1T0050NXC1AOOOO 26200 DZ1F0050NXC1AOOOO 31500 1
DZ1-160N/
43-63 DZ1T0063NXD1AOOOO 25400 DZ1F0063NXD1AOOOO 30600 1
DZ1-200N
54-80 DZ1T0080NXD1AOOOO 25400 DZ1F0080NXD1AOOOO 30600 1
67-100 DZ1T0100NXD1AOOOO 25400 DZ1F0100NXD1AOOOO 30600 1
84-125 DZ1T0125NXD1AOOOO 33500 DZ1F0125NXD1AOOOO 37000 1
108-160 DZ1T0160NXD1AOOOO 36400 DZ1F0160NXD1AOOOO 43500 1
134-200 DZ1T0200NXD1AOOOO 53500 DZ1F0200NXD1AOOOO 67100 1
11-16 DZ2T0016NXC1AOOOO 30300 DZ2F0016NXC1AOOOO 36300 1
14-20 DZ2T0020NXC1AOOOO 30300 DZ2F0020NXC1AOOOO 36300 1
17-25 50kA DZ2T0025NXC1AOOOO 30300 DZ2F0025NXC1AOOOO 36300 1
22-32 DZ2T0032NXC1AOOOO 30300 DZ2F0032NXC1AOOOO 36300 1
27-40 DZ2T0040NXC1AOOOO 30300 DZ2F0040NXC1AOOOO 36300 1
DZ2-160N 34-50 DZ2T0050NXC1AOOOO 30300 DZ2F0050NXC1AOOOO 36300 1
43-63 DZ2T0063NXD1AOOOO 29300 DZ2F0063NXD1AOOOO 35200 1
54-80 DZ2T0080NXD1AOOOO 29300 DZ2F0080NXD1AOOOO 35200 1
67-100 DZ2T0100NXD1AOOOO 29300 DZ2F0100NXD1AOOOO 35200 1
84-125 DZ2T0125NXD1AOOOO 38500 DZ2F0125NXD1AOOOO 42500 1
108-160 DZ2T0160NXD1AOOOO 41800 DZ2F0160NXD1AOOOO 49900 1
108-160 DZ4T0160NXD1AOOOO 47500 DZ4F0160NXD1AOOOO 60000 1
DZ4-250N 134-200 DZ4T0200NXD1AOOOO 51800 DZ4F0200NXD1AOOOO 65000 1
168-250 DZ4T0250NXD1AOOOO 54600 DZ4F0250NXD1AOOOO 68600 1
134-200 DZ6T0200NXD1AOOOO 63300 DZ6F0200NXD1AOOOO 78200 1
168-250 DZ6T0250NXD1AOOOO 66600 DZ6F0250NXD1AOOOO 82400 1
DZ6-400N
215-320 DZ6T0320NXD1AOOOO 68800 DZ6F0320NXD1AOOOO 85000 1
268-400 DZ6T0400NXD1AOOOO 68800 DZ6F0400NXD1AOOOO 85000 1
335-500 DZ7T0500NXD1AOOOO 85300 DZ7F0500NXD1AOOOO 110200 1
DZ7-800N
422-630 DZ7T0630NXD1AOOOO 85300 DZ7F0630NXD1AOOOO 110200 1
536-800 DZ7T0800NXD1AOOOO 115100 DZ7F0800NXD1AOOOO 146500 1
11-16 DZ2T0016HXC1AOOOO 38800 DZ2F0016HXC1AOOOO 42900 1
14-20 DZ2T0020HXC1AOOOO 38800 DZ2F0020HXC1AOOOO 42900 1
17-25 DZ2T0025HXC1AOOOO 38800 DZ2F0025HXC1AOOOO 42900 1
22-32 DZ2T0032HXC1AOOOO 38800 DZ2F0032HXC1AOOOO 42900 1
27-40 DZ2T0040HXC1AOOOO 38800 DZ2F0040HXC1AOOOO 42900 1
DZ2-160H
34-50 DZ2T0050HXC1AOOOO 38800 DZ2F0050HXC1AOOOO 42900 1
43-63 DZ2T0063HXD1AOOOO 37600 DZ2F0063HXD1AOOOO 41700 1
54-80 DZ2T0080HXD1AOOOO 37600 DZ2F0080HXD1AOOOO 41700 1
67-100 DZ2T0100HXD1AOOOO 37600 DZ2F0100HXD1AOOOO 41700 1
84-125 DZ2T0125HXD1AOOOO 56100 DZ2F0125HXD1AOOOO 62000 1
108-160 80kA DZ2T0160HXD1AOOOO 59800 DZ2F0160HXD1AOOOO 66900 1
108-160 DZ4T0160HXD1AOOOO 68100 DZ4F0160HXD1AOOOO 76000 1
DZ4-250H 134-200 DZ4T0200HXD1AOOOO 79200 DZ4F0200HXD1AOOOO 95300 1
168-250 DZ4T0250HXD1AOOOO 82500 DZ4F0250HXD1AOOOO 99100 1
134-200 DZ6T0200HXD1AOOOO 89000 DZ6F0200HXD1AOOOO 105400 1
168-250 DZ6T0250HXD1AOOOO 91700 DZ6F0250HXD1AOOOO 108700 1
DZ6-400H
215-320 DZ6T0320HXD1AOOOO 92800 DZ6F0320HXD1AOOOO 109800 1
268-400 DZ6T0400HXD1AOOOO 92800 DZ6F0400HXD1AOOOO 109800 1
335-500 DZ7T0500HXD1AOOOO 110400 DZ7F0500HXD1AOOOO 131800 1
DZ7-800H 422-630 DZ7T0630HXD1AOOOO 110400 DZ7F0630HXD1AOOOO 131800 1
536-800 DZ7T0800HXD1AOOOO 129800 DZ7F0800HXD1AOOOO 169600 1
Lauritz Knudsen, 15.08.2026 43PDF page 51 DZ MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DZ MCCB Range [8536]
DZ MCCB with Microprocessor Release
Rating (A)
40 63 100 160 200 250 400 630 800 1000
Icu (kA)
36/50 DZ1
36/50/80/120 DZ2
36/50/80/120/200 DZ4 DZ4
36/50/80/120/200 DZ6 DZ7
DZ MCCB with Microprocessor Release iTRP1
› Conforms to IS/IEC 60947-2
› 16A to 1000A, 3P & 4P
› 36kA, 50kA, 80kA, 120kA & 200kA breaking capacities
› Ics=100% Icu
› Adjustable overload setting from 0.25 to 1.0 x In
› Adjustable short-circuit setting from 1.5 to 12 x Ir*
› Switchable thermal memory
› Variable trip class
› Transparent sealable release cover
› Compact size
› Fixed, Plug-in, Drawout, Rotary and Motorised versions available
dsine-DZ iTRP1 › Wide range of accessories
Overload Breaking 3 Pole 4 Pole
Std.
Release Capacity Icu
Type Pkg.
Range at 415V AC, Cat No M.R.P. (`) Cat No M.R.P. (`)
Per Unit Per Unit (Nos.)
(A) 50Hz. (kA)
10-40 DZ1T0040DXF1AOOOO 39600 DZ1F0040DXF1AOOOO 48300 1
16-63 DZ1T0063DXF1AOOOO 39600 DZ1F0063DXF1AOOOO 48300 1
DZ1-160D#/ DZ1T0100DXF1AOOOO DZ1F0100DXF1AOOOO 1
25-100 39600 48300
DZ1-200D
40-160 DZ1T0160DXF1AOOOO 46600 DZ1F0160DXF1AOOOO 65000 1
50-200 DZ1T0200DXF1AOOOO 60900 DZ1F0200DXF1AOOOO 84000 1
10-40 DZ2T0040DXF1AOOOO 41800 DZ2F0040DXF1AOOOO 50900 1
16-63 DZ2T0063DXF1AOOOO 41800 DZ2F0063DXF1AOOOO 50900 1
DZ2-160D#
25-100 36kA DZ2T0100DXF1AOOOO 41800 DZ2F0100DXF1AOOOO 50900 1
40-160 DZ2T0160DXF1AOOOO 49300 DZ2F0160DXF1AOOOO 68400 1
40-160 DZ4T0160DXF1AOOOO 60300 DZ4F0160DXF1AOOOO 84000 1
DZ4-250D
63-250 DZ4T0250DXF1AOOOO 62800 DZ4F0250DXF1AOOOO 86900 1
63-250 DZ6T0250DXF1AOOOO 75100 DZ6F0250DXF1AOOOO 97300 1
DZ6-400D
100-400 DZ6T0400DXF1AOOOO 79100 DZ6F0400DXF1AOOOO 102400 1
158-630 DZ7T0630DXF1AOOOO 96700 DZ7F0630DXF1AOOOO 125300 1
DZ7-800D/
200-800 DZ7T0800DXF1AOOOO 127000 DZ7F0800DXF1AOOOO 157200 1
DZ7-1000D
250-1000 DZ7T1000DXF1AOOOO 208600 DZ7F1000DXF1AOOOO 289200 1
10-40 DZ1T0040NXF1AOOOO 45900 DZ1F0040NXF1AOOOO 63200 1
16-63 DZ1T0063NXF1AOOOO 45900 DZ1F0063NXF1AOOOO 63200 1
DZ1-160N#/ 25-100 DZ1T0100NXF1AOOOO 45900 DZ1F0100NXF1AOOOO 63200 1
DZ1-200N
40-160 DZ1T0160NXF1AOOOO 57600 DZ1F0160NXF1AOOOO 75700 1
50-200 DZ1T0200NXF1AOOOO 71900 DZ1F0200NXF1AOOOO 91000 1
50kA
10-40 DZ2T0040NXF1AOOOO 48300 DZ2F0040NXF1AOOOO 66800 1
16-63 DZ2T0063NXF1AOOOO 48300 DZ2F0063NXF1AOOOO 66800 1
DZ2-160N#
25-100 DZ2T0100NXF1AOOOO 48300 DZ2F0100NXF1AOOOO 66800 1
40-160 DZ2T0160NXF1AOOOO 60700 DZ2F0160NXF1AOOOO 79600 1
Lauritz Knudsen, 15.08.2026 44PDF page 52 DZ MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DZ MCCB Range [8536]
DZ MCCB with Microprocessor Release iTRP1
Overload Breaking 3 Pole 4 Pole
Std.
Release Capacity Icu
Type Pkg.
Range at 415V AC, Cat No M.R.P. (`) Cat No M.R.P. (`)
Per Unit Per Unit (Nos.)
(A) 50Hz. (kA)
40-160 DZ4T0160NXF1AOOOO 69300 DZ4F0160NXF1AOOOO 88900 1
DZ4-250N
63-250 DZ4T0250NXF1AOOOO 73900 DZ4F0250NXF1AOOOO 93700 1
63-250 DZ6T0250NXF1AOOOO 83800 DZ6F0250NXF1AOOOO 109300 1
DZ6-400N
100-400 50kA DZ6T0400NXF1AOOOO 88100 DZ6F0400NXF1AOOOO 115000 1
158-630 DZ7T0630NXF1AOOOO 106900 DZ7F0630NXF1AOOOO 136600 1
DZ7-800N/
200-800 DZ7T0800NXF1AOOOO 145400 DZ7F0800NXF1AOOOO 185000 1
DZ7-1000N
250-1000 DZ7T1000NXF1AOOOO 259700 DZ7F1000NXF1AOOOO 360100 1
10-40 DZ2T0040HXF1AOOOO 56500 DZ2F0040HXF1AOOOO 70200 1
16-63 DZ2T0063HXF1AOOOO 56500 DZ2F0063HXF1AOOOO 70200 1
DZ2-160H#
25-100 DZ2T0100HXF1AOOOO 56500 DZ2F0100HXF1AOOOO 70200 1
40-160 DZ2T0160HXF1AOOOO 73800 DZ2F0160HXF1AOOOO 92400 1
40-160 DZ4T0160HXF1AOOOO 79200 DZ4F0160HXF1AOOOO 99100 1
DZ4-250H 80kA
63-250 DZ4T0250HXF1AOOOO 88800 DZ4F0250HXF1AOOOO 122000 1
63-250 DZ6T0250HXF1AOOOO 111000 DZ6F0250HXF1AOOOO 146800 1
DZ6-400H
100-400 DZ6T0400HXF1AOOOO 116900 DZ6F0400HXF1AOOOO 154200 1
158-630 DZ7T0630HXF1AOOOO 121100 DZ7F0630HXF1AOOOO 176400 1
DZ7-800H/
200-800 DZ7T0800HXF1AOOOO 176300 DZ7F0800HXF1AOOOO 230500 1
DZ7-1000H
250-1000 DZ7T1000HXF1AOOOO 301300 DZ7F1000HXF1AOOOO 436000 1
- Spreader Terminals are included
* For DZ7 630A / 800A & 1000A: Magnetic setting from 1.5 In to 10 In / 1.5 In to 8 In respectively
#
For 25A, please contact nearest branch office
Note:
Breaking Capacity: D = 36kA, N = 50kA, H = 80kA
dsine DZ-120kA & 200kA @415V (Ics=100% Icu) MCCBs are available on request.
It is recommended to use spreader terminals for enhancing termination capacity
dsine DZ Selectivity Version MCCBs are available on request.
DZ MCCB with Microprocessor Release iTRP3
› Conforms to IS/IEC 60947-2
› 16A to 1000A, 3P & 4P
› 36kA, 50kA, 80kA, 120kA & 200kA breaking capacities
› Ics=100% Icu
› Adjustable overload setting from 0.25 to 1.0 x In
› Adjustable short-circuit setting from 1.5 to 12 x Ir*
› Adjustable Instantaneous setting, 6 In & 12 In
› Inbuilt ground fault protection from 20% to 70% of In
› Adjustable neutral overload protection from 50% to 200% of Ir
› Switchable thermal memory
› Provision for release testing
› Individual fault indication LEDs
› Transparent sealable release cover
dsine-DZ iTRP3 › Compact size
› Fixed, Plug-in, Drawout, Rotary and Motorised versions available
› Wide range of accessories
Lauritz Knudsen, 15.08.2026 45PDF page 53 DZ MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DZ MCCB Range [8536]
DZ MCCB with Microprocessor Release iTRP3
Overload Breaking 3 Pole 4 Pole
Std.
Release Capacity Icu
Type Pkg.
Range at 415V AC, Cat No M.R.P. (`) Cat No M.R.P. (`)
Per Unit Per Unit (Nos.)
(A) 50Hz. (kA)
10-40 DZ1T0040DXH1AOOOO 66500 DZ1F0040DXH1AOOOO 77400 1
16-63 DZ1T0063DXH1AOOOO 66500 DZ1F0063DXH1AOOOO 77400 1
DZ1-160D#/
25-100 DZ1T0100DXH1AOOOO 66500 DZ1F0100DXH1AOOOO 77400 1
DZ1-200D
40-160 DZ1T0160DXH1AOOOO 76400 DZ1F0160DXH1AOOOO 94100 1
50-200 DZ1T0200DXH1AOOOO 87300 DZ1F0200DXH1AOOOO 107100 1
10-40 DZ2T0040DXH1AOOOO 69400 DZ2F0040DXH1AOOOO 81000 1
16-63 DZ2T0063DXH1AOOOO 69400 DZ2F0063DXH1AOOOO 81000 1
DZ2-160D#
25-100 DZ2T0100DXH1AOOOO 69400 DZ2F0100DXH1AOOOO 81000 1
36kA
40-160 DZ2T0160DXH1AOOOO 79800 DZ2F0160DXH1AOOOO 98200 1
40-160 DZ4T0160DXH1AOOOO 86300 DZ4F0160DXH1AOOOO 106000 1
DZ4-250D
63-250 DZ4T0250DXH1AOOOO 89900 DZ4F0250DXH1AOOOO 110400 1
63-250 DZ6T0250DXH1AOOOO 103600 DZ6F0250DXH1AOOOO 120000 1
DZ6-400D
100-400 DZ6T0400DXH1AOOOO 108800 DZ6F0400DXH1AOOOO 126200 1
158-630 DZ7T0630DXH1AOOOO 121600 DZ7F0630DXH1AOOOO 151400 1
DZ7-800D/
200-800 DZ7T0800DXH1AOOOO 163000 DZ7F0800DXH1AOOOO 193700 1
DZ7-1000D
250-1000 DZ7T1000DXH1AOOOO 242800 DZ7F1000DXH1AOOOO 320500 1
10-40 DZ1T0040NXH1AOOOO 73600 DZ1F0040NXH1AOOOO 87700 1
16-63 DZ1T0063NXH1AOOOO 73600 DZ1F0063NXH1AOOOO 87700 1
DZ1-160N#/ 25-100 DZ1T0100NXH1AOOOO 73600 DZ1F0100NXH1AOOOO 87700 1
DZ1-200N
40-160 DZ1T0160NXH1AOOOO 87400 DZ1F0160NXH1AOOOO 104600 1
50-200 DZ1T0200NXH1AOOOO 98200 DZ1F0200NXH1AOOOO 119900 1
10-40 DZ2T0040NXH1AOOOO 76800 DZ2F0040NXH1AOOOO 91600 1
16-63 DZ2T0063NXH1AOOOO 76800 DZ2F0063NXH1AOOOO 91600 1
DZ2-160N#
25-100 DZ2T0100NXH1AOOOO 76800 DZ2F0100NXH1AOOOO 91600 1
50kA
40-160 DZ2T0160NXH1AOOOO 91300 DZ2F0160NXH1AOOOO 109500 1
40-160 DZ4T0160NXH1AOOOO 97400 DZ4F0160NXH1AOOOO 118800 1
DZ4-250N
63-250 DZ4T0250NXH1AOOOO 101200 DZ4F0250NXH1AOOOO 123600 1
63-250 DZ6T0250NXH1AOOOO 110900 DZ6F0250NXH1AOOOO 132200 1
DZ6-400N
100-400 DZ6T0400NXH1AOOOO 116800 DZ6F0400NXH1AOOOO 139100 1
158-630 DZ7T0630NXH1AOOOO 129400 DZ7F0630NXH1AOOOO 171100 1
DZ7-800N/ 200-800 199400 236800
DZ7T0800NXH1AOOOO DZ7F0800NXH1AOOOO 1
DZ7-1000N
250-1000 DZ7T1000NXH1AOOOO 302400 DZ7F1000NXH1AOOOO 399000 1
10-40 DZ2T0040HXH1AOOOO 91500 DZ2F0040HXH1AOOOO 108800 1
16-63 DZ2T0063HXH1AOOOO 91500 DZ2F0063HXH1AOOOO 108800 1
DZ2-160H#
25-100 DZ2T0100HXH1AOOOO 91500 DZ2F0100HXH1AOOOO 108800 1
40-160 DZ2T0160HXH1AOOOO 108900 DZ2F0160HXH1AOOOO 121400 1
40-160 80kA DZ4T0160HXH1AOOOO 116700 DZ4F0160HXH1AOOOO 134700 1
DZ4-250H
63-250 DZ4T0250HXH1AOOOO 133600 DZ4F0250HXH1AOOOO 157400 1
63-250 DZ6T0250HXH1AOOOO 154100 DZ6F0250HXH1AOOOO 193000 1
DZ6-400H
100-400 DZ6T0400HXH1AOOOO 162500 DZ6F0400HXH1AOOOO 203000 1
158-630 DZ7T0630HXH1AOOOO 175800 DZ7F0630HXH1AOOOO 241700 1
DZ7-800H/ 236000 294600
200-800 DZ7T0800HXH1AOOOO DZ7F0800HXH1AOOOO 1
DZ7-1000H
250-1000 DZ7T1000HXH1AOOOO 379600 DZ7F1000HXH1AOOOO 492100 1
- Spreader Terminals are included
* For DZ7 630A / 800A & 1000A: Magnetic setting from 1.5 In to 10 In / 1.5 In to 8 In respectively
#
For 25A, please contact nearest branch office
Note:
Breaking Capacity : D = 36kA, N = 50kA, H = 80kA
dsine DZ 120kA & 200kA @415V (Ics=100% Icu) MCCBs are available on request.
It is recommended to use spreader terminals for enhancing termination capacity
dsine DZ Selectivity Version MCCBs are available on request. Lauritz Knudsen, 15.08.2026 46PDF page 54 DZ MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DZ MCCB Range [8536]
Rating (A)
40 63 100 160 200 250 400 630 800 1000
Icu (kA)
DZ1$
36/50/80/120 DZ2
36/50/80/120/200 DZ4 DZ4
36/50/80/120/200 DZ6 DZ7
iTRP4 Only
$
DZ MCCB with Microprocessor Releases iTRP4 & iTRP5
› Confirms to IS/IEC 60947-2
› 16A to 1000A, 3P & 4P
› 36kA, 50kA, 80kA, 120kA & 200kA breaking capacities
› Ics=100% Icu
› Adjustable Overload Settings from 0.25 to 1 In (in steps of 0.01)
› Adjustable Short Circuit Settings from 1.5 to 12 Ir (in steps of 0.1)
› Adjustable Instantaneous Settings from 1.5 to 12 Ir (in steps of 0.1)
› In-built Ground Fault Protection from 0.1 to 1 In (in steps of 0.05)
› Adjustable Neutral Overload Protection from 50% to 160% of Ir
› Local LCD Display Menu Navigation using Keypad
› Modbus RTU Communication Capable
› Switchable Thermal Memory
› Provision for Release Testing
Advance Metering
› Variable trip class
Solution
› Transparent sealable release cover
› Compact size
› Wide range of accessories
Measurement & Diagnostics
› Advanced Current based protection function via iTRP4 Release
› Advanced Energy based protection function via iTRP5 Release
› I²T, SI, LI-VI based over load curves
› Advanced Protections like Maximum Demand, Phase Sequence, THD etc
› Common Fault Indication and Diagnostic LED
› Self, Auxiliary and Battery Mode
› Trip & Event Records available
› Communication module for remote monitoring & control
› Temperature module with thermal sensors for online temperature monitoring
› Zone Selective Interlocking (ZSI) module for system level coordination of faults
Accessories for iTRP4 & iTRP5 [8538]
Modules Details
Communication Module
Aux. Power Supply Module
Temperature Module (with Thermal Sensors)
Zone Selective Interlocking Module
Programmable Relay Module
* On request
Lauritz Knudsen, 15.08.2026 47PDF page 55 DZ MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DZ MCCB Range [8536]
DZ MCCBs for Motor back-up Protection
› Range: 16A to 800A, 50kA
› Suitable for isolation
› Wide Range of snap fit Internal and External Accessories
3 Pole
Current Breaking Capacity Std.
Type Rating Icu at 415V. AC, Cat. No. M.R.P. (`) Pkg.
Per Unit
(A) 50Hz. (kA) (Nos.)
32 DZ0T0032N5M1AOOOO 10300 1
DZ M Version
40 DZ0T0040N5M1AOOOO 10300 1
63 DZ0T0063N5M1AOOOO 10200 1
DZ0-125N 80 DZ0T0080N5M1AOOOO 10200 1
100 DZ0T0100N5M1AOOOO 10200 1
125 DZ0T0125N5M1AOOOO 13400 1
32 DZ1T0032NXM1AOOOO 13500 1 Contactor
40 DZ1T0040NXM1AOOOO 13500 1
63 DZ1T0063NXM1AOOOO 13400 1
DZ1-160N/ 80 DZ1T0080NXM1AOOOO 13400 1 Overload Relay
DZ1-200N 50kA
100 DZ1T0100NXM1AOOOO 13400 1
125 DZ1T0125NXM1AOOOO 14000 1
160 DZ1T0160NXM1AOOOO 16100 1
200 DZ1T0200NXM1AOOOO 30000 1
DZ4-250N 250 DZ4T0250NXM1AOOOO 38800 1
320 DZ6T0320NXM1AOOOO 49000 1 Motor
DZ6-400N
400 DZ6T0400NXM1AOOOO 51400 1
500 DZ7T0500NXM1AOOOO 68600 1
DZ7-800N 630 DZ7T0630NXM1AOOOO 72900 1 Representative Application Image
800 DZ7T0800NXM1AOOOO 76000 1
- Spreader Terminals are included
Note:
Please contact nearest branch office for Fuseless Type 2 Co-ordination selection charts.
For Microprocessor based Motor back-up Protection MCCBs, please contact nearest branch office.
For lower HP Motors, Please select MMS. Details are given on page no.21
Give your motor
the right protection
dsine DZ is compact and comes with a wide range of snap-fit accessories.
Why settle for anything else?
-DZ
Lauritz Knudsen, 15.08.2026 48PDF page 56 DZ 800V MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DZ 800V MCCB Range [8536]
Rating (A)
200 250 320 400 500 630
Icu (kA) @ 800V
25/36/50 DZ6
36/50 DZ7
› Conforms to IS/IEC 60947-2
› 200A to 630A, 3P/4P
› 25kA, 36kA & 50kA @800V breaking capacities
› Ics=100% Icu
› Rated insulation voltage: 1250V AC rms
› Adjustable overload settings: 0.67 - 1.0 x In
› Adjustable short-circuit settings: 6 - 12 x In**
› Transparent sealable release cover
› Ambient Temperature Compensation
› High Electrical & Mechanical life***
› Manual and Rotary versions available
› Standard Back Insulating Plates included for 3P MCCBs
dsine-DZ TM › Wide range of accessories
DZ 800V with Thermal - Magnetic Release
Overload Breaking 3 Pole 4 Pole
Std.
Release Capacity Icu
Type Pkg.
Range at 800V AC, Cat No M.R.P. (`) Cat No M.R.P. (`)
Per Unit Per Unit (Nos.)
(A) 50Hz. (kA)
134-200 DZ6T0200WXD1AOOOO DZ6F0200WXD1AOOOO 1
DZ6-400W 25kA
168-250 DZ6T0250WXD1AOOOO DZ6F0250WXD1AOOOO 1
134-200 DZ6T0200YXD1AOOOO DZ6F0200YXD1AOOOO 1
168-250 DZ6T0250YXD1AOOOO DZ6F0250YXD1AOOOO 1
DZ6-400Y
214-320 DZ6T0320YXD1AOOOO DZ6F0320YXD1AOOOO 1
36kA
268-400 DZ6T0400YXD1AOOOO DZ6F0400YXD1AOOOO 1
335-500 DZ7T0500YXD1AOOOO DZ7F0500YXD1AOOOO 1
DZ7-800Y
422-630 DZ7T0630YXD1AOOOO DZ7F0630YXD1AOOOO 1
134-200 DZ6T0200ZXD1AOOOO DZ6F0200ZXD1AOOOO 1
168-250 DZ6T0250ZXD1AOOOO DZ6F0250ZXD1AOOOO 1
DZ6-400Z
214-320 DZ6T0320ZXD1AOOOO DZ6F0320ZXD1AOOOO 1
50kA
268-400 DZ6T0400ZXD1AOOOO DZ6F0400ZXD1AOOOO 1
335-500 DZ7T0500ZXD1AOOOO DZ7F0500ZXD1AOOOO 1
DZ7-800Z
422-630 DZ7T0630ZXD1AOOOO DZ7F0630ZXD1AOOOO 1
* Price on request
** For DZ7 630A - Magnetic setting from 6 In to 10 In
*** Mechanical Life - 20000 Operations; Electrical Life - 4000 Operations (DZ6) & 2500 Operations (DZ7)
General Information
› Ambient temperature compensation in MCCBs helps prevent nuisance tripping by adjusting for temperature variations that affect the thermal elements.
High ambient temperatures can cause premature tripping, while low temperatures may delay it. This is most suitable for Solar application.
Lauritz Knudsen, 15.08.2026 49PDF page 57 DZ 800V MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DZ 800V MCCB Range [8536]
Rating (A)
125 160 200 250 320 400 500 630 800
Icu (kA) @ 800V
25/36/50 DZ6
DZ6
36/50 DZ7
DZ7
› Conforms to IS/IEC 60947-2
› 125A to 800A, 3P/4P
› 25kA, 36kA & 50kA @800V breaking capacities
› Ics=100% Icu
› Rated insulation voltage: 1250V AC rms
› Adjustable overload setting from 0.25 to 1.0 x In
› Adjustable short-circuit setting from 1.5 to 12 x Ir**
› Switchable thermal memory
› Variable trip class
› Transparent sealable release cover
› High Electrical & Mechanical life***
› Manual and Rotary versions available
dsine-DZ iTRP1 › Standard Back Insulating Plates included for 3P MCCBs
› Wide range of accessories
DZ 800V with Microprocessor Release iTRP1
Overload Breaking 3 Pole 4 Pole
Std.
Release Capacity Icu
Type Pkg.
Range at 800V AC, Cat No M.R.P. (`) Cat No M.R.P. (`)
Per Unit Per Unit (Nos.)
(A) 50Hz. (kA)
31-125 DZ6T0125WXF1AOOOO DZ6F0125WXF1AOOOO 1
40-160 DZ6T0160WXF1AOOOO DZ6F0160WXF1AOOOO 1
50-200 DZ6T0200WXF1AOOOO DZ6F0200WXF1AOOOO 1
DZ6-400W 25kA
63-250 DZ6T0250WXF1AOOOO DZ6F0250WXF1AOOOO 1
80-320 DZ6T0320WXF1AOOOO DZ6F0320WXF1AOOOO 1
100-400 DZ6T0400WXF1AOOOO DZ6F0400WXF1AOOOO 1
31-125 DZ6T0125YXF1AOOOO DZ6F0125YXF1AOOOO 1
40-160 DZ6T0160YXF1AOOOO DZ6F0160YXF1AOOOO 1
50-200 DZ6T0200YXF1AOOOO DZ6F0200YXF1AOOOO 1
DZ6-400Y
63-250 DZ6T0250YXF1AOOOO DZ6F0250YXF1AOOOO 1
80-320 36kA DZ6T0320YXF1AOOOO DZ6F0320YXF1AOOOO 1
100-400 DZ6T0400YXF1AOOOO DZ6F0400YXF1AOOOO 1
125-500 DZ7T0500YXF1AOOOO DZ7F0500YXF1AOOOO 1
DZ7-800Y 156-630 DZ7T0630YXF1AOOOO DZ7F0630YXF1AOOOO 1
200-800 DZ7T0800YXF1AOOOO DZ7F0800YXF1AOOOO 1
31-125 DZ6T0125ZXF1AOOOO DZ6F0125ZXF1AOOOO 1
40-160 DZ6T0160ZXF1AOOOO DZ6F0160ZXF1AOOOO 1
50-200 DZ6T0200ZXF1AOOOO DZ6F0200ZXF1AOOOO 1
DZ6-400Z
63-250 DZ6T0250ZXF1AOOOO DZ6F0250ZXF1AOOOO 1
80-320 50kA DZ6T0320ZXF1AOOOO DZ6F0320ZXF1AOOOO 1
100-400 DZ6T0400ZXF1AOOOO DZ6F0400ZXF1AOOOO 1
125-500 DZ7T0500ZXF1AOOOO DZ7F0500ZXF1AOOOO 1
DZ7-800Z 156-630 DZ7T0630ZXF1AOOOO DZ7F0630ZXF1AOOOO 1
200-800 DZ7T0800ZXF1AOOOO DZ7F0800ZXF1AOOOO 1
* Price on request
** For DZ7 630A / 800A, Magnetic setting from 1.5 In to 10 In / 1.5 In to 8 In respectively
*** Mechanical Life - 20000 Operations; Electrical Life - 4000 Operations (DZ6) & 2500 Operations (DZ7)
Lauritz Knudsen, 15.08.2026 50PDF page 58 DZ 800V MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DZ 800V MCCB Range [8536]
Rating (A)
200 250 320 400 500 630 800
Icu (kA) @ 800V
25/36/50 DZ6
36/50 DZ7
› Conforms to IS/IEC 60947-2
› 125A to 800A, 3P/4P
› 25kA, 36kA & 50kA @800V breaking capacities
› Ics=100% Icu
› Rated insulation voltage: 1250V AC rms
› Adjustable overload setting from 0.25 to 1.0 x In
› Adjustable short-circuit setting from 1.5 to 12 x Ir**
› Adjustable Instantaneous setting, 6 In & 12 In
› Inbuilt ground fault protection from 20% to 70% of In
› Adjustable neutral overload protection from 50% to 200% of Ir
› Switchable thermal memory
› Variable trip class
› Individual fault indication LEDs
› Transparent sealable release cover
dsine-DZ iTRP3
› High Electrical & Mechanical life***
› Manual and Rotary versions available
› Standard Back Insulating Plates included for 3P MCCBs
› Wide range of accessories
DZ 800V with Microprocessor Release iTRP3
Overload Breaking 3 Pole 4 Pole
Std.
Release Capacity Icu
Type Pkg.
Range at 800V AC, M.R.P. (`) Cat No M.R.P. (`)
Cat No Per Unit Per Unit (Nos.)
(A) 50Hz. (kA)
50-200 DZ6T0200WXH1AOOOO DZ6F0200WXH1AOOOO 1
63-250 DZ6T0250WXH1AOOOO DZ6F0250WXH1AOOOO 1
DZ6-400W 25kA
80-320 DZ6T0320WXH1AOOOO DZ6F0320WXH1AOOOO 1
100-400 DZ6T0400WXH1AOOOO DZ6F0400WXH1AOOOO 1
50-200 DZ6T0200YXH1AOOOO DZ6F0200YXH1AOOOO 1
63-250 DZ6T0250YXH1AOOOO DZ6F0250YXH1AOOOO 1
DZ6-400Y
80-320 DZ6T0320YXH1AOOOO DZ6F0320YXH1AOOOO 1
100-400 36kA DZ6T0400YXH1AOOOO DZ6F0400YXH1AOOOO 1
125-500 DZ7T0500YXH1AOOOO DZ7F0500YXH1AOOOO 1
DZ7-800Y 156-630 DZ7T0630YXH1AOOOO DZ7F0630YXH1AOOOO 1
200-800 DZ7T0800YXH1AOOOO DZ7F0800YXH1AOOOO 1
50-200 DZ6T0200ZXH1AOOOO DZ6F0200ZXH1AOOOO 1
63-250 DZ6T0250ZXH1AOOOO DZ6F0250ZXH1AOOOO 1
DZ6-400Z
80-320 DZ6T0320ZXH1AOOOO DZ6F0320ZXH1AOOOO 1
100-400 50kA DZ6T0400ZXH1AOOOO DZ6F0400ZXH1AOOOO 1
125-500 DZ7T0500ZXH1AOOOO DZ7F0500ZXH1AOOOO 1
DZ7-800Z 156-630 DZ7T0630ZXH1AOOOO DZ7F0630ZXH1AOOOO 1
200-800 DZ7T0800ZXH1AOOOO DZ7F0800ZXH1AOOOO 1
* Price on request
** For DZ7 630A / 800A, Magnetic setting from 1.5 In to 10 In / 1.5 In to 8 In respectively
*** Mechanical Life - 20000 Operations; Electrical Life - 4000 Operations (DZ6) & 2500 Operations (DZ7)
Lauritz Knudsen, 15.08.2026 51PDF page 59 Accessories for DZ MCCBs [8538]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Accessories for DZ MCCBs [8538]
Auxiliary Contact Shunt Release UV Release
Trip Alarm Contact
Internal Accessories Internal Accessories
Std. Std.
M.R.P. (`) Pkg. M.R.P. (`) Pkg.
Description Cat No Per Unit (Nos.) Description Cat No Per Unit (Nos.)
Auxillary Contact/ Trip Alarm Contact [8538] Under Voltage Release [8538]
DZ0 Aux/TAC 1 C/o EM90966OOOO 1150 1 DZ0 UVR 240V AC EM90518BOOO 4690 1
DZ1/2/4 Aux/TAC 1 C/o EM90110OOOO 1800 1 DZ1/2/4 UVR 415V AC EM90031POOO 6180 1
DZ6/7 Aux/TAC 1 C/o EM90114OOOO 1960 1 DZ1/2/4 UVR 240V AC EM90031BOOO 6180 1
Shunt Release [8538] DZ1/2/4 UVR 110V AC EM90031EOOO 6180 1
DZ0 Shunt 110/240/415V AC EM90520OMOO 1560 1 DZ1/2/4 UVR 48V AC EM90031JOOO 6180 1
DZ1/2/4 Shunt 415V AC EM90032OPOO 4780 1 DZ1/2/4 UVR 24V AC EM90031GOOO 6180 1
DZ1/2/4 Shunt 240V AC EM90032OBOO 4780 1 DZ1/2/4 UVR 220V DC EM900312OOO 6180 1
DZ1/2/4 Shunt 110V AC EM90032OAOO 4780 1 DZ1/2/4 UVR 110V DC EM900311OOO 6180 1
DZ1/2/4 Shunt 48V AC EM90032OJOO 4780 1 DZ1/2/4 UVR 48V DC EM900315OOO 6180 1
DZ1/2/4 Shunt 24V AC EM90032OGOO 4780 1 DZ1/2/4 UVR 24V DC EM900314OOO 6180 1
DZ1/2/4 Shunt 220V DC EM90032O2OO 4780 1 DZ1/2/4 UVR 12V DC EM900313OOO 6180 1
DZ1/2/4 Shunt 110V DC EM90032O1OO 4780 1 DZ6/7 UVR 415V AC EM90033POOO 6860 1
DZ1/2/4 Shunt 48V DC EM90032O5OO 4780 1 DZ6/7 UVR 240V AC EM90033BOOO 6860 1
DZ1/2/4 Shunt 24V DC EM90032O4OO 4780 1 DZ6/7 UVR 110V AC EM90033EOOO 6860 1
DZ1/2/4 Shunt 12V DC EM90032O3OO 4780 1 DZ6/7 UVR 48V AC EM90033JOOO 6860 1
DZ6/7 Shunt 415V AC EM90034OPOO 5350 1 DZ6/7 UVR 24V AC EM90033GOOO 6860 1
DZ6/7 Shunt 240V AC EM90034OBOO 5350 1 DZ6/7 UVR 220V DC EM900332OOO 6860 1
DZ6/7 Shunt 110V AC EM90034OEOO 5350 1 DZ6/7 UVR 110V DC EM900331OOO 6860 1
DZ6/7 Shunt 48V AC EM90034OJOO 5350 1 DZ6/7 UVR 48V DC EM900335OOO 6860 1
DZ6/7 Shunt 24V AC EM90034OGOO 5350 1 DZ6/7 UVR 24V DC EM900334OOO 6860 1
DZ6/7 Shunt 220V DC EM90034O2OO 5350 1 DZ6/7 UVR 12V DC EM900333OOO 6860 1
DZ6/7 Shunt 110V DC EM90034O1OO 5350 1
DZ6/7 Shunt 48V DC EM90034O5OO 5350 1
DZ6/7 Shunt 24V DC EM90034O4OO 5350 1
DZ6/7 Shunt 12V DC EM90034O3OO 5350 1
Lauritz Knudsen, 15.08.2026 52PDF page 60 Accessories for DZ MCCBs [8538]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Accessories for DZ MCCBs [8538]
Direct ROM Extended ROM Key Lock EOM Spreaders Terminals Rear Terminals Box Clamp
Terminals
External Accessories External Accessories
Std. Std.
M.R.P. (`) Pkg. Cat No M.R.P. (`) Pkg.
Description Cat No Per Unit (Nos.) Description Per Unit (Nos.)
Rotary Mechanism (Direct/Extended) [8538] Spreader Terminals (Up to 690V AC #) [8538]
DZ0 Direct ROM EM90969OOOO 2130 1 DZ0-100 3 Pole CM97785OOOO@ 770 Set of 6
DZ1 Direct ROM EM90207OOOO 2370 1 DZ0-100 4 Pole CM97921OOOO @
1200 Set of 8
DZ2 Direct ROM EM90208OOOO 2700 1 DZ1, DZ2-160 3 Pole EM90609OOOO 2930 Set of 6
DZ4 Direct ROM EM90386OOOO 3150 1 DZ1, DZ2-160 4 Pole EM90610OOOO 3830 Set of 8
DZ6 Direct ROM EM90228OOOO 3900 1 DZ4-250 - 3 Pole EM94096OOOO 4760 Set of 6
DZ7 Direct ROM EM90350OOOO 5410 1 DZ4-250 - 4 Pole EM94097OOOO 6360 Set of 8
DZ0 Extended ROM EM90970OOOO 3060 1 DZ6-400 - 3 Pole EM90611OOOO 7140 Set of 6
DZ1 Extended ROM EM90209OOOO 3200 1 DZ6-400 - 4 Pole EM90612OOOO 9590 Set of 8
DZ2 Extended ROM EM90210OOOO 3760 1 DZ7-630 - 3 Pole EM97050OOOO 21500 Set of 6
DZ4 Extended ROM EM90293OOOO 4770 1 DZ7-630 - 4 Pole EM97052OOOO 28600 Set of 8
DZ6 Extended ROM EM90276OOOO 6290 1 DZ7-800 - 3 Pole EM97051OOOO 26900 Set of 6
DZ7 Extended ROM EM90381OOOO 6600 1 DZ7-800 - 4 Pole EM97053OOOO 35000 Set of 8
Panel Door mounted Key lock for Extended ROM [8301] Rear Terminals [8538]
DZ0/1/2/4 Key Lock Type 1 8760 DZ1-160 3 Pole EM91176OOOO 7460 Set of 6
EM99031OOOO 1
8760 DZ1-160 4 Pole EM91177OOOO 10700 Set of 8
DZ0/1/2/4 Key Lock Type 2 EM99031OOOA 1
DZ2-160 3 Pole EM92088OOOO 8270 Set of 6
DZ0/1/2/4 Key Lock Type 3 EM99031OOOB 8760 1
DZ2-160 4 Pole EM92089OOOO 11700 Set of 8
DZ0/1/2/4 Key Lock Type 12 EM99031OOOC 8760 1
DZ4-250 - 3 Pole EM94058OOOO 10000 Set of 6
DZ0/1/2/4 Key Lock Type 23 EM99031OOOD 8760 1
DZ4-250 - 4 Pole EM94059OOOO 14400 Set of 8
DZ6/7 Key Lock Type 1 EM99141OOOO 10400 1
DZ6-400 - 3 Pole EM96045OOOO 13600 Set of 6
DZ6/7 Key Lock Type 2 EM99141OOOA 10400 1
DZ6-400 - 4 Pole EM96046OOOO 19700 Set of 8
DZ6/7 Key Lock Type 3 EM99141OOOB 10400 1
DZ7-800 - 3 Pole EM97045OOOO 25400 Set of 6
DZ6/7 Key Lock Type 12 EM99141OOOC 10400 1
DZ7-800 - 4 Pole EM97046OOOO 36900 Set of 8
DZ6/7 Key Lock Type 23 EM99141OOOD 10400 1
Box Clamp Termination [8538]
Electrical Operating Mechanism [8538]
DZ1, DZ2-160 3 Pole EM92176OOOO 6270 Set of 6
DZ1 240V AC EM90490BOOO 54900 1
DZ1, DZ2-160 4 Pole EM92177OOOO 8960 Set of 8
DZ2 240V AC EM90545BOOO 59900 1
DZ4-250 - 3 Pole EM94094OOOO 11600 Set of 6
DZ4 240V AC *
DZ4-250 - 4 Pole EM94095OOOO 16700 Set of 8
DZ6 240V AC EM90355BOOO 85300 1
DZ6-400 - 3 Pole EM96985OOOO 15800 Set of 6
DZ7 240V AC EM90480BOOO 115700 1
DZ6-400 - 4 Pole EM96370OOOO 22800 Set of 8
* Price on request
Note:
Note:
For Electrical Operating Mechanism, refer wiring diagram from
Phase Barriers are supplied along with MCCBs
Product Catalogue or Product Manual. @
Change in CAT No.
#
For 800V Application Spreaders, please contact nearest branch office
Lauritz Knudsen, 15.08.2026 53PDF page 61 Accessories for DZ MCCBs [8538]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Accessories for DZ MCCBs [8538]
DZ1 DZ2 DZ4 DZ6 DZ7
Fixed Kit +
Plug-in Full Kit
Conversion Kit
Draw-out - Fixed Kit + Conversion Kit
Plug-in Draw-out
External Accessories External Accessories
Std. Std.
M.R.P. (`) Pkg. Description Cat No M.R.P. (`) Pkg.
Description Cat No Per Unit (Nos.) Per Unit (Nos.)
Plug-in Module [8538] Draw-out Module [8538]
DZ1 3 Pole Full Kit EM90201OOOO * 1 DZ4 3 Pole Fixed Kit EM90260OOOO * 1
DZ1 4 Pole Full Kit EM90202OOOO * 1 DZ4 3 Pole Conversion Kit EM90258OOOO * 1
DZ2 3 Pole Full Kit EM90262OOOO * 1 DZ4 4 Pole Fixed Kit EM90261OOOO * 1
DZ2 4 Pole Full Kit EM90263OOOO * 1 DZ4 4 Pole Conversion Kit EM90259OOOO * 1
DZ4 3 Pole Full Kit EM90250OOOO * 1 DZ6 3 Pole Fixed Kit EM90256OOOO * 1
DZ4 4 Pole Full Kit EM90251OOOO * 1 DZ6 3 Pole Conversion Kit EM90254OOOO * 1
DZ6 3 Pole Full Kit EM90246OOOO * 1 DZ6 4 Pole Fixed Kit EM90257OOOO * 1
DZ6 4 Pole Full Kit EM90247OOOO * 1 DZ6 4 Pole Conversion Kit EM90255OOOO * 1
DZ7-630 3 Pole Fixed Kit EM99256OOOO * 1 DZ7-630 3 Pole Fixed Kit EM99105OOOO * 1
DZ7-630 3 Pole Conversion Kit EM99254OOOO * 1 DZ7-630 3 Pole Conversion Kit EM99103OOOO * 1
DZ7-630 4 Pole Fixed Kit EM99257OOOO * 1 DZ7-630 4 Pole Fixed Kit EM99106OOOO * 1
DZ7-630 4 Pole Conversion Kit EM99255OOOO * 1 DZ7-630 4 Pole Conversion Kit EM99104OOOO * 1
DZ7-800 3 Pole Fixed Kit EM99061OOOO * 1 DZ7-800 3 Pole Fixed Kit EM90455OOOO * 1
DZ7-800 3 Pole Conversion Kit EM99069OOOO * 1 DZ7-800 3 Pole Conversion Kit EM90453OOOO * 1
DZ7-800 4 Pole Fixed Kit EM99062OOOO * 1 DZ7-800 4 Pole Fixed Kit EM90456OOOO * 1
DZ7-800 4 Pole Conversion Kit EM99070OOOO * 1 DZ7-800 4 Pole Conversion Kit EM90454OOOO * 1
* Price on request Direct ROM or EOM is to be ordered mandatorily along with Drawout Module
* Price on request
Std. Std.
M.R.P. (`) Pkg. M.R.P. (`) Pkg.
Description Cat No Per Unit (Nos.) Description Cat No Per Unit (Nos.)
Short Terminal Shroud $ [8538] External Neutral CT [8504]
DZ1-160 3 Pole EM99081OOOO 3570 1 DZ1, DZ2 - 40A, 63A, 80A EM90507OOOO 4420 1
DZ1-160 4 Pole EM99082OOOO 4300 1 DZ1, DZ2 - 100A, 160A EM90508OOOO 4530 1
DZ2-160 3 Pole EM99085OOOO 3570 1 DZ1 - 200A EM90509OOOO 4570 1
DZ2-160 4 Pole EM99087OOOO 4300 1 DZ4 - 160A, 250A EM90512OOOO 6780 1
DZ4-250 - 3 Pole EM99089OOOO 3760 1 DZ6 - 250A, 400A EM90515OOOO 8330 1
DZ4-250 - 4 Pole EM99091OOOO 5480 1 DZ7 - 630A, 800A EM90516OOOO 12900 1
DZ6-400 - 3 Pole EM99093OOOO 5000 1 DZ7 - 1000A EM97326OOOO 13600 1
DZ6-400 - 4 Pole EM99094OOOO 6790 1 Adaptor Kit for External Neutral CT [8538]
DZ7-630/800 - 3 Pole EM99097OOOO 5440 1 DZ1, DZ2 & DZ4 - Up to 250A CM99994OOOO 1410 Set of 2
DZ7-630/800 - 4 Pole EM99099OOOO 7500 1 DZ6 - Up to 400A CM99995OOOO 2600 Set of 2
$ Long Terminal Shrouds available on request DZ7 - Up to 1000A EM97227OOOO 9440 Set of 2
Lauritz Knudsen, 15.08.2026 54PDF page 62 Accessories for DZ MCCBs [8538]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Accessories for DZ MCCBs [8538]
Mechanical Interlocking
Kit Range DZ1 DZ2 DZ4 DZ6
Front Slider ü ü ü
Rear Base Plate - - ü ü
Cable Base Plate ü ü ü ü
Front Slider Cable Base Plate Rear Base Plate
External Accessories External Accessories
Std. Std.
M.R.P. (`) Pkg. M.R.P. (`) Pkg.
Description Cat No Per Unit Description Cat No Per Unit
(Nos.) (Nos.)
Mechanical Interlocking Options [8538] 3. Cable Base Plate MIL #
1. Front Slider MIL # a. Base Plate with Cable (for MCCBs without Rear Terminations)
DZ1 Front Slider EM90396OOOO 5350 1 DZ1/DZ2 Cable Base Plate $ EM90404OOOO 9600 1
DZ2 Front Slider EM90397OOOO 5630 1 DZ4 Cable Base Plate $ EM90405OOOO 11500 1
DZ2/DZ4 Front Slider EM90398OOOO 7620 1 DZ6 Cable Base Plate $ EM90406OOOO 15000 1
b. Base Plate with Cable (for MCCBs with Rear Terminations)
Front Slider MIL
DZ1 DZ2 DZ4
Selection Table DZ1/DZ2 Cable Base Plate RT $ EM90401OOOO 10600 1
DZ1 ü DZ4 Cable Base Plate RT $ EM90402OOOO 12700 1
DZ2 ü ü DZ6 Cable Base Plate RT $ EM90403OOOO 16600 1
DZ4 ü ü c. Cable Types and Lengths - For DZ1/ DZ2/ DZ4/ DZ6 MCCBs
(for both MCCBs with and without Rear Terminations)
L Cable (1 m Length) $ EM00471OOOO 2500 1
External Accessories
Std. L Cable (3 m Length) $ EM00474OOOO 3770 1
M.R.P. (`) Pkg.
Description Cat No Per Unit (Nos.) L Cable (5 m Length) $ EM00477OOOO 5220 1
#
2. Rear Base Plate MIL
M Cable (1 m Length) $ EM00472OOOO 2500 1
DZ4 Mounting Plate ~ EM90400OOOO 5560 1
M Cable (3 m Length) $ EM00475OOOO 3770 1
DZ6 Mounting Plate ~ EM90399OOOO 6930 1
M Cable (5 m Length) $ EM00478OOOO 5220 1
DZ4 Rear Base Plate ~ EM90354OOOO 27400 1
H Cable (1 m Length) $ EM00473OOOO 2500 1
DZ4/DZ6 Rear Base Plate ~ EM90353OOOO 34400 1
H Cable (3 m Length) $ EM00476OOOO 3770 1
DZ7 Rear Base Plate EM99142OOOO 68000 1 H Cable (5 m Length) $ EM00479OOOO 5220 1
~ - 2 Nos of Mounting Plate and 1 No of Base Plate must be ordered
$ - 2 Nos of Base Plate & 1 No of suitable length of Cable must be ordered
together along with 2 Nos of MCCBs. together along with 2 Nos of MCCBs.
Rear Base Plate Base Plate Mounting Plate
MIL Selection Table
(DZ4 & DZ6) EM90353 EM90354 EM90399 EM90400
DZ4-DZ4 X 1No. X 2 Nos.
DZ4-DZ6 1No. X 1No. 1No.
DZ6-DZ6 1No. X 2 Nos. X
Cable Base Plate DZ1 DZ2 DZ4 DZ6
MIL Selection Table
EM90404 EM90401 EM90404 EM90401 EM90405 EM90402 EM90406 EM90403
EM90404 L L
DZ1
EM90401 M
EM90404 L L L M L M
DZ2
EM90401 M L M M H
EM90405 L M L M
DZ4
EM90402 H M H
EM90406 M H
DZ6
EM90403 H
#
Common for 3P & 4P MCCBs
Lauritz Knudsen, 15.08.2026 55PDF page 63 DN MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DN MCCB Range [8536]
DN MCCB with Thermal - Magnetic Release
Rating (A)
16 20 25 32 40 50 63 80 100 125 160 200 250 320 400 500 630
Icu=Ics (kA)*
25 DN0-100C DN1-C
36 DN0-100D/125D DN3B
36/50/70 DN2 DN3
› Conforms to IS/IEC 60947-2
› 20A to 630A, 3P & 4P
› 25kA, 36kA, 50kA & 70kA breaking capacities
› Ics= 100% of Icu*
› Adjustable overload settings: 0.8 - 1.0 x In
› Adjustable short-circuit settings: 6 - 10 x In**
› Manual & Rotary versions available
› Wide range of accessories
dsine TM
Thermal Breaking 3 Pole 4 Pole
Std.
Release Capacity Icu
Type Pkg.
Range at 415V AC, Cat. No. M.R.P. (`) Cat. No. M.R.P. (`)
Per Unit Per Unit (Nos.)
(A) 50Hz. (kA)
16-20 CM97893OOC2OG 11600 CM97919OOC2OG 16400 1
20-25 CM97893OOD2OG 11600 CM97919OOD2OG 16400 1
25-32 CM97893OOE2OG 11600 CM97919OOE2OG 16400 1
32-40 CM97893OOF2OG 11600 CM97919OOF2OG 16400 1
DN0-100D* 36
40-50 CM97893OOG2OG 11600 CM97919OOG2OG 16400 1
50-63 CM97893OOH2OG 11300 CM97919OOH2OG 15900 1
63-80 CM97893OOJ2OG 11300 CM97919OOJ2OG 15900 1
80-100 CM97893OOK2OG 11300 CM97919OOK2OG 15900 1
DN0-125D* 100-125 CM90680OOLOOG 14100 CM90681OOLOOG 18600 1
16-20 CM91612OOCOOG 12100 CM91712OOCOOG 16900 1
20-25 CM91612OODOOG 12100 CM91712OODOOG 16900 1
25-32 CM91612OOEOOG 12100 CM91712OOEOOG 16900 1
32-40 CM91612OOFOOG 12100 CM91712OOFOOG 16900 1
DN0-100C
40-50 CM91612OOGOOG 12100 CM91712OOGOOG 16900 1
50-63 CM91612OOHOOG 11700 CM91712OOHOOG 16400 1
25
63-80 CM91612OOJOOG 11700 CM91712OOJOOG 16400 1
80-100 CM91612OOKOOG 11700 CM91712OOKOOG 16400 1
100-125 CM90638OOLO 16600 CM90642OOLO 20300 1
125-160 CM90638OOMO 21500 CM90642OOMO 26100 1
DN1-250C
160-200 CM90638OONO 27500 CM90642OONO 32900 1
200-250 CM90638OOPO 32200 CM90642OOPO 37400 1
Note:
Breaking Capacity : C = 25kA, D = 36kA, N = 50kA, S = 70kA
* DN0-100D/125D : Ics= 50% Icu
** For DN0, DN1, DN3B-Short Circuit Setting: 9In
For DN1-250N (50kA) please contact nearest branch office
*** From 16A to 50A, Fixed Magnetic setting (375A)
Lauritz Knudsen, 15.08.2026 56PDF page 64 DN MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DN MCCB Range [8536]
DN MCCB with Thermal - Magnetic Release
Thermal Breaking 3 Pole 4 Pole
Capacity Icu Std.
Release
Type Pkg.
Range at 415V AC, Cat. No. M.R.P. (`) Cat. No. M.R.P. (`)
Per Unit (Nos.)
(A) 50Hz. (kA) Per Unit
100-125 CM92008OOL1OG 28700 CM92108OOL1OG 35500 1
125-160 CM92008OOM1OG 35500 CM92108OOM1OG 43800 1
DN2-250D
160-200 CM92009OON1OG 36800 CM92109OON1OG 47100 1
200-250 CM92009OOP1OG 41900 CM92109OOP1OG 51700 1
250-320 CM98401OOQOOG 57000 CM98403OOQOOG 69500 1
DN3B-400D
320-400 36 CM98401OOROOG 57000 CM98403OOROOG 69500 1
250-320 CM94005OOQ1OG * CM94105OOQ1OG * 1
DN3-400D
320-400 CM94005OOR1OG * CM94105OOR1OG * 1
400-500 CM94006OOS1OG 73400 CM94106OOS1OG 92500 1
DN3-630D
500-630 CM94006OOT1OG 73400 CM94106OOT1OG 92500 1
100-125 CM92005OOL1OG 39900 CM92105OOL1OG 48400 1
125-160 CM92005OOM1OG 40900 CM92105OOM1OG 51500 1
DN2-250N
160-200 CM92006OON1OG 41800 CM92106OON1OG 52400 1
200-250 50 CM92006OOP1OG 47000 CM92106OOP1OG 58900 1
250-320 CM94003OOQ1OG 61900 CM94103OOQ1OG 76700 1
DN3-400N
320-400 CM94003OOR1OG 61900 CM94103OOR1OG 76700 1
400-500 CM94004OOS1OG 81500 CM94104OOS1OG 105200 1
DN3-630N
500-630 CM94004OOT1OG 81500 CM94104OOT1OG 105200 1
100-125 CM92002OOL1OG * CM92102OOL1OG * 1
125-160 CM92002OOM1OG * CM92102OOM1OG * 1
DN2-250S
160-200 CM92003OON1OG * CM92103OON1OG * 1
200-250 CM92003OOP1OG * CM92103OOP1OG * 1
70##
250-320 CM94001OOQ1OG * CM94101OOQ1OG * 1
DN3-400S
320-400 CM94001OOR1OG * CM94101OOR1OG * 1
400-500 CM94002OOS1OG * CM94102OOS1OG * 1
DN3-630S
500-630 CM94002OOT1OG * CM94102OOT1OG * 1
* Price on request
## Available till stock lasts.
General Information
› Use of phase barriers is mandatory. These are supplied along with MCCBs
› It is recommended to use spreader terminals for enhancing termination capacity
› Spreader terminals are available as accessories, unless otherwise specified against cat. nos.
Special Applications
› dsine-DN/DU/DY MCCBs with TM release can be used for DC application (2P/3P/4P)
› dsine-DN/DU MCCBs can be used for Capacitor back-up protection
› For Motor back-up protection, use ‘M’ series of MCCBs
› For isolator applications, use SD version (without protection release)
Lauritz Knudsen, 15.08.2026 57PDF page 65 DN MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DN MCCB Range [8536]
DN MCCB with Microprocessor Release
Rating (A)
40 63 100 160 250 400 630 800 1000 1250
Icu (kA)
36/50/70/100 DN2 DN3
50/70/100 DN4
DN MCCB with Microprocessor Release MTX1.0
› Conforms to IS/IEC 60947-2
› 40A to 1250A, 3P & 4P
› 36kA, 50kA, 70kA and 100kA breaking capacities
› Ics=100% Icu
› Adjustable overload setting from 0.4 to 1.0 x In
› Adjustable short-circuit setting from 1.5 to 8 x Ir
› Inbuilt instantaneous Protection
› Switchable thermal memory
› Variable trip class
› Front LED Indication
› Manual & Rotary versions available
› Wide range of accessories
dsine DN MTX1.0
Breaking 3 Pole 4 Pole
Release Std.
Capacity Icu
Type Range M.R.P. (`) M.R.P. (`) Pkg.
(A) at 415V AC, Cat. No. Cat. No. (Nos.)
Per Unit Per Unit
50Hz. (kA)
16-40 CM92063OOOOX1 48800 CM92155OOOOX1 61200 1
25-63 CM92071OOOOX1 48800 CM92154OOOOX1 61200 1
DN2-250D 40-100 CM92051OOOOX1 48800 CM92153OOOOX1 61200 1
63-160 36 CM92074OOOOX1 61500 CM92152OOOOX1 85600 1
100-250 CM92054OOOOX1 64100 CM92151OOOOX1 88700 1
DN3-400D 160-400 CM93001OOOOX1 78800 CM93003OOOOX1 102000 1
DN3-630D 250-630 CM93005OOOOX1 87100 CM93007OOOOX1 115200 1
16-40 CM92064OOOOX1 55500 CM92160OOOOX1 73500 1
25-63 CM92072OOOOX1 55500 CM92159OOOOX1 73500 1
DN2-250N 40-100 CM92052OOOOX1 55500 CM92158OOOOX1 73500 1
63-160 CM92075OOOOX1 72000 CM92157OOOOX1 93600 1
100-250 CM92055OOOOX1 76900 CM92156OOOOX1 95700 1
50
DN3-400N 160-400 CM93002OOOOX1 86100 CM93004OOOOX1 112400 1
DN3-630N 250-630 CM93006OOOOX1 94600 CM93008OOOOX1 123400 1
320-800 CM96021OOOOX1 136000 CM96111OOOOX1 172900 1
DN4-1250N 400-1000 CM96022OOOOX1 201100 CM96112OOOOX1 283100 1
500-1250 CM96023OOOOX1 251100 CM96113OOOOX1 339600 1
16-40 CM92065OOOOX1 * CM92165OOOOX1 * 1
25-63 CM92073OOOOX1 * CM92164OOOOX1 * 1
DN2-250S 40-100 CM92059OOOOX1 * CM92163OOOOX1 * 1
63-160 CM92076OOOOX1 * CM92162OOOOX1 * 1
100-250 CM92056OOOOX1 * CM92161OOOOX1 * 1
70##
DN3-400S 160-400 CM94053OOOOX1 * CM94153OOOOX1 * 1
DN3-630S 250-630 CM94079OOOOX1 * CM94179OOOOX1 * 1
320-800 CM96025OOOOX1 145800 CM96115OOOOX1 191000 1
DN4-1250S 400-1000 CM96026OOOOX1 210000 CM96116OOOOX1 309100 1
500-1250 CM96027OOOOX1 271900 CM96117OOOOX1 369900 1
Note:
## Available till stock lasts.
dsine DN-V Version (Icu=Ics=100kA) MCCBs are available till stock lasts.
Lauritz Knudsen, 15.08.2026 58PDF page 66 DN MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DN MCCB Range [8536]
DN MCCB with Microprocessor Release MTX2.0
› Conforms to IS/IEC 60947-2
› 40A to 1250A, 3P & 4P
› 36kA, 50kA, 70kA and 100kA breaking capacities
› Ics=100% Icu
› Adjustable overload setting from 0.4 to 1.0 x In
› Adjustable short-circuit setting from 1.5 to 8 x Ir
› Inbuilt instantaneous Protection
› Inbuilt ground fault protection from 20%-50% of In
› Adjustable neutral overload protection from 50% to 150% of Ir
› Switchable thermal memory
› Variable trip class
› Front LED Indication
› Panel mounted display for current metering & trip record
dsine DN MTX2.0
› Manual & Rotary versions available
› Wide range of accessories
Breaking 3 Pole 4 Pole
Release Std.
Capacity Icu
Type Range Pkg.
at 415V AC, Cat. No. M.R.P. (`) Cat. No. M.R.P. (`)
(A) Per Unit Per Unit (Nos.)
50Hz. (kA)
16-40 CM92063OOOOAG 83400 CM92155OOOOAG 95900 1
25-63 CM92071OOOOAG 83400 CM92154OOOOAG 95900 1
DN2-250D 40-100 CM92051OOOOAG 83400 CM92153OOOOAG 95900 1
63-160 36 CM92074OOOOAG 90600 CM92152OOOOAG 111200 1
100-250 CM92054OOOOAG 91800 CM92151OOOOAG 112600 1
DN3-400D 160-400 CM93001OOOOAG 108600 CM93003OOOOAG 125700 1
DN3-630D 250-630 CM93005OOOOAG 118800 CM93007OOOOAG 144000 1
16-40 CM92064OOOOAG 90600 CM92160OOOOAG 108000 1
25-63 CM92072OOOOAG 90600 CM92159OOOOAG 108000 1
DN2-250N 40-100 CM92052OOOOAG 90600 CM92158OOOOAG 108000 1
63-160 CM92075OOOOAG 94400 CM92157OOOOAG 114900 1
100-250 50 CM92055OOOOAG 95200 CM92156OOOOAG 115800 1
DN3-400N 160-400 CM93002OOOOAG 114000 CM93004OOOOAG 136000 1
DN3-630N 250-630 CM93006OOOOAG 126300 CM93008OOOOAG 162700 1
320-800 CM96021OOOOAG 181300 CM96111OOOOAG 215100 1
DN4-1250N 400-1000 CM96022OOOOAG 233400 CM96112OOOOAG 309300 1
500-1250 CM96023OOOOAG 291900 CM96113OOOOAG 377800 1
16-40 CM92065OOOOAG * CM92165OOOOAG * 1
25-63 CM92073OOOOAG * CM92164OOOOAG * 1
DN2-250S 40-100 CM92059OOOOAG * CM92163OOOOAG * 1
63-160 CM92076OOOOAG * CM92162OOOOAG * 1
100-250 CM92056OOOOAG * CM92161OOOOAG * 1
70##
DN3-400S 160-400 CM94053OOOOAG * CM94153OOOOAG * 1
DN3-630S 250-630 CM94079OOOOAG * CM94179OOOOAG * 1
320-800 CM96025OOOOAG 208600 CM96115OOOOAG 260900 1
DN4-1250S 400-1000 CM96026OOOOAG 291300 CM96116OOOOAG 379400 1
500-1250 CM96027OOOOAG 358900 CM96117OOOOAG 470600 1
Accessories for MTX2.0 [8538]
Modules for M.R.P. (`)
Cat. No.
MTX2.0 release Per Unit
Current Metering Module
(Display & Metering Module)## CM95698OOOO 72700
Current Metering &
Cable (2m length)## CM01196OOOO 3390 latest trip record
Power Supply Module## CL90722OOOO *
UNCO Module for Status Indication 24300
CL90852OOOO
& Control through communication##
Note:
* Price on request
## Available till stock lasts.
dsine DN-V Version (Icu=Ics=100kA) MCCBs are available till stock lasts.
Lauritz Knudsen, 15.08.2026 59PDF page 67 DN MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DN MCCB Range [8536]
DN MCCB with Microprocessor Release MTX3.0
› Conforms to IS/IEC 60947-2 & IEC 60947-2
› Range: 40A to 1250A, 3P & 4P
› Choice of 36kA / 50kA / 70kA / 100kA breaking capacities
› Ics = 100% Icu
› Suitable for Isolation
› Adjustable Over Load from 0.4 - 1.0 x In
› Adjustable Short Circuit from 1.5 - 8 x Ir with selectable time delay
› Instantaneous protection with fine settings
› Inbuilt ground fault protection from 10% - 50% of In
› Adjustable neutral overload protection available : 50% to 150% of Ir
› Advanced Current, Voltage, Frequency & Power based protections
› Other Protections like Maximum Demand, Phase Sequence, THD etc.
› Comprehensive Current, Power, Energy, PF, MD, THD metering
› Provision of Thermal Memory : ON/OFF
› Variable trip class at 1.5 Ir,6 Ir & 7.2 Ir
› Front LED indication of Over Load, short circuit & earth fault
dsine DN MTX3.0 › Panel mounted display available for advanced protections & metering
› Communication capable release
› Manual & Rotary versions available
› For 3 phase 4 wire system, External neutral CTs available for 3P MCCBs
› Wide Range of snap fit Internal and External Accessories
Breaking 3 Pole 4 Pole
Release Std.
Capacity Icu
Type Range Pkg.
at 415V AC, Cat. No. M.R.P. (`) Cat. No. M.R.P. (`)
(A) Per Unit Per Unit (Nos.)
50Hz. (kA)
16 - 40 CM92063OOOOBG CM92155OOOOBG 1
25 - 63 CM92071OOOOBG CM92154OOOOBG 1
DN2-250D 40 - 100 CM92051OOOOBG CM92153OOOOBG 1
63 - 160 36 CM92074OOOOBG CM92152OOOOBG 1
100 - 250 CM92054OOOOBG CM92151OOOOBG 1
DN3-400D 160 - 400 CM93001OOOOBG CM93003OOOOBG 1
DN3-630D 250 - 630 CM93005OOOOBG CM93007OOOOBG 1
16 - 40 CM92064OOOOBG CM92160OOOOBG 1
25 - 63 CM92072OOOOBG CM92159OOOOBG 1
DN2-250N 40 - 100 CM92052OOOOBG CM92158OOOOBG 1
63 - 160 CM92075OOOOBG CM92157OOOOBG 1
100 - 250 CM92055OOOOBG CM92156OOOOBG 1
50
DN3-400N 160 - 400 CM93002OOOOBG CM93004OOOOBG 1
DN3-630N 250 - 630 CM93006OOOOBG CM93008OOOOBG 1
320 - 800 CM96021OOOOBG CM96111OOOOBG 1
DN4-1250N 400 - 1000 CM96022OOOOBG CM96112OOOOBG 1
500 - 1250 CM96023OOOOBG CM96113OOOOBG 1
16 - 40 CM92065OOOOBG CM92165OOOOBG 1
25 - 63 CM92073OOOOBG CM92164OOOOBG 1
DN2-250S 40 - 100 CM92059OOOOBG CM92163OOOOBG 1
63 - 160 CM92076OOOOBG CM92162OOOOBG 1
100 - 250 CM92056OOOOBG CM92161OOOOBG 1
70##
DN3-400S 160 - 400 CM94053OOOOBG CM94153OOOOBG 1
DN3-630S 250 - 630 CM94079OOOOBG CM94179OOOOBG 1
320 - 800 CM96025OOOOBG CM96115OOOOBG 1
DN4-1250S 400 - 1000 CM96026OOOOBG CM96116OOOOBG 1
500 - 1250 CM96027OOOOBG CM96117OOOOBG 1
Accessories for MTX3.0 [8538]
M.R.P.
Modules for MTX3.0 release Cat. No. (`)
Per Unit
Communication Module## CM95680OOOO *
Voltage Module## CM95685OOOO *
Display Module## CM95676OOOO *
Power Supply Module## CL90722OOOO *
UNCO Module for Status Indication &
Control through communication## CL90852OOOO 24300
Note:
* Price on request
## Available till stock lasts.
dsine DN-V Version (Icu=Ics=100kA) MCCBs are available till stock lasts.
Lauritz Knudsen, 15.08.2026 60PDF page 68 DN MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DN MCCB Range [8536]
DN MCCBs for Motor back-up Protection
##
› Range: 32A to 630A, 50kA
› Suitable for isolation
› Wide Range of snap fit Internal and External Accessories
3 Pole
Current Breaking
Std. MCCB-M version
Capacity Icu M.R.P. (`)
Type Rating Cat. No. Pkg.
at 415V. AC, Per Unit
(A) (Nos.)
50Hz. (kA)
32 CM98944OOEO * 1
40 CM98944OOFO * 1
50 CM98944OOGO * 1
DN0-100M
63 CM98944OOHO * 1 Contactor
80 CM98944OOJO * 1
100 CM98944OOKO * 1
100 CM90345OOKO * 1 Overload Relay
DN1-160M 125 50 CM90345OOLO * 1
160 CM90345OOMO * 1
200 CM92171OONOOG * 1
DN2-250M
250 CM92171OOPOOG * 1
320 CM94516OOQOOG * 1
DN3-400M
400 CM94516OOROOG * 1 Motor
500 CM94515OOSOOG * 1
DN3-630M
630 CM94515OOTOOG * 1
* Price on request Representative Application Image
Note:
Please contact nearest branch office for fuseless type 2 co-ordination selection chart
For lower HP Motors, Please select MMS. Details are given on page no.21
dsine-DN M version MCCBs are available till stock lasts.
## Available till stock lasts.
Lauritz Knudsen, 15.08.2026 61PDF page 69 DN MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DN MCCB Range [8536]
DN Switch Disconnector - SD (MCCBs without protection release)
› Used as switching devices for isolation
› Range: 32A to 1250A, 3P & 4P
› Suitable for isolation
› Wide Range of snap fit Internal and External Accessories PCC
DG
Transformer
CB-1 MCCB-5 as Isolator CB-2
3 Pole 4 Pole
Current Std.
Type Rating M.R.P. M.R.P. Pkg.
(A) Cat. No. (`) Cat. No. (`) (Nos.) CB-3 CB-4
Per Unit Per Unit
32 CM90716OOEO 10500 CM90717OOEO 14100 1
63 CM90716OOHO 10500 CM90717OOHO 14100 1
DN0-160SD 100 CM90716OOKO 12400 CM90717OOKO 16400 1
125 CM90716OOLO 13800 CM90717OOLO 18300 1
160 CM90716OOMO 14900 CM90717OOMO 19400 1 MCC
200 CM96814OONOOG 29800 CM96815OONOOG 39700 1
DN2-250SD MCCB-6 as Isolator
250 CM96802OOPOOG 32100 CM96803OOPOOG 42500 1
320 CM98410OOQOOG 47400 CM98412OOQOOG 61500 1
DN3B-400SD
400 CM98410OOROOG 47400 CM98412OOROOG 61500 1
SCPD-1 SCPD-2
500 CM96806OOSOOG 53700 CM96807OOSOOG 73400 1
DN3-630SD
630 CM96806OOTOOG 53700 CM96807OOTOOG 73400 1 Starter-1 Starter-2
800 CM93041OOUO 107300 CM93042OOUO 132100 1
M M
DN4-1250SD 1000 CM93041OOVO 142500 CM93042OOVO 182400 1
1250 CM93041OOAO 189000 CM93042OOAO 234300 1 Representative Application Image
Automatic Source Transfer System (ASTS)**
› 128x80 pixel, backlit LCD screen with 4 grey levels
› Advanced programmable I/O function
› Management of automatic generator start/stop
› Controls of UV, OV, phase loss, asymmetry, minimum frequency,
maximum frequency, with independent enabling and time delay
AuXC-2000
Automatic Transfer Controllers (ATC) [9032] 2 MCCBs + 2 SE-EOM + 2 ATAC + 1 MIL kit
M.R.P. (`) Std. Pkg.
Type Cat. No.
Per Unit (Nos.)
AuXC-2000 controller** ATC2000OOOO 52600 1 For AuXC 2000/2100 programming videos and more details
please scan the QR code or click here
Can be used along with ACB, Motorised MCCBs, MCX contactors &
Motorised Changeover switches
Note:
** For communication version of AuXC controller refer page no-6
Total Set
Frame Accessories Remarks
M.R.P. (`)
Add MRPs of Similar 2 MCCBs of DN2 of
DN2 * desired no. of Poles, Breaking Cap. &
2 Nos : SEOMs with Aux + Trip Alarm Contact Release to arrive at ASTS Solution.
+
DN3-400 1 No. : MIL *
Add MRPs of Similar 2 MCCBs of DN3 of
+ desired no. of Poles, Breaking Cap. &
Release to arrive at ASTS Solution.
1 No. : AuXC2000
DN3-630 *
* Price on request
Note:
Picture shown is for representation purpose only, MCCB + EOM + ATAC combination, MIL kit & AuXC-2000 to be purchased separately & assembled at site.
dsine-DN COMBO MCCBs are available till stock lasts.
For ASTS Solution in MCCB, please refer DZ range.
Lauritz Knudsen, 15.08.2026 62PDF page 70 Accessories for DN MCCBs [8538]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Accessories for DN MCCBs [8538]
Auxiliary Contact TAC Shunt Release UV Release Neutral CT Direct ROM Extended ROM Key Lock
Internal External
Description M.R.P. Std.
Description M.R.P. Std.
Cat. No. (`) Pkg.
Cat. No. (`) Pkg.
Per Unit (Nos.)
Per Unit (Nos.)
Auxiliary Contact [8538]
Rotary Handle [8538]
DN0, DN1 - 1 C/O - Right CM97886OOOO 1650 1 1
DN0 Direct ROM CM97895OOOO 2100
DN0, DN1 - 2 C/O - Right CM97887OOOO 2910 1 1
DN1 Direct ROM CM98040OOOO 2260
DN2, DN3B, DN3, DN4 - 1 C/O CM99801OOOO 1920 1
DN2 Direct ROM CM99829OOOO 2330 1
DN2, DN3B, DN3, DN4 - 2 C/O CM99802OOOO 3710 1 1
DN3B, DN3 Direct ROM CM99860OOOO 3480
Trip Alarm Contact [8538] 1
DN0 Extended ROM CM97896OOOO 2720
DN0, DN1 - 1 C/O - Right CM97888OOOO 1650 1 1
DN1 Extended ROM CM98041OOOO 2900
DN0, DN1 - 2 C/O - Right CM97889OOOO 2910 1
DN2 Extended ROM CM99830OOOO 3500 1
DN2, DN3B, DN3, DN4 - 1 C/O - Right CM99803OOOO 2010 1
DN3B, DN3 Extended ROM CM99861OOOO 5720 1
Auxiliary 1 C/O + TAC 1 C/O [8538] 1
DN4 Extended ROM CM99884OOOO 7260
DN0, DN1 - Right CM97890OOOO 2800 1 Panel door mounted Key lock for Extended ROM # [8301]
DN2, DN3B, DN3, DN4 - Right CM99804OOOO 3710 1
Type 1 CM99958TOOOO 9670 1
Shunt Release [8538]
Type 2 CM99958TOOOA 9670 1
DN0, DN1 - 24V DC - Left CM91402O4OO 3260 1
Type 3 CM99958TOOOB 9670 1
DN0, DN1 - 110V AC - Left CM97883OAOO 3260 1
Type 12 CM99958TOOOC 9670 1
DN0, DN1 - 240/415V AC - Left CM97883OMOO 3260 1
Type 23 CM99958TOOOD 9670 1
DN2, DN3 - 110V DC - Left CM99807OOOO 5760 1
# - Can be used with dsine DN & DU new look extended ROM
DN2, DN3B, DN3, DN4 - 110/240/415V AC,220V DC CM99805OOOO 4800@ 1
DN2, DN3B, DN3 - 24V DC CM98976O4OO 4800@ 1
Under Voltage Release [8538]
DN0, DN1 - 240V AC - Left CM97892BOOO 5400 1
DN2, DN3B, DN3 - 240V AC - Left CM99986BOOO 6680 **
1
DN4 - 240V AC - Left CM99906OOOO 7630** 1 Spreader Terminals MIL Kit - Base Mounted
@
- ‘NO’ of control contactor to be connected in series for DC control supply External
** Use these UV Cat. Nos. with Grey look MCCBs only
Description M.R.P. Std.
Cat. No. (`) Pkg.
Per Unit (Nos.)
External Spreader Terminals [8538]
Description M.R.P. Std.
Cat. No. (`) Pkg. DN0-100 - 3 Pole CM97785OOOO 770 Set of 6
Per Unit (Nos.) DN0-125D - 3 Pole CM90687OOLO 900 Set of 6
External Neutral CT [8504]
DN1, DN2 - 250 - 3 Pole ST98053OOOO 3000 Set of 6
DN2 - 40A CM99946OOOO 3110 1
DN3B/DN3 - 400 - 3 Pole ST98065OOOO 5520 Set of 6
DN2 - 63A CM99947OOOO 3110 1
DN3-630 - 3 Pole ST98054OOOO 6500 Set of 6
DN2 - 100A CM99948OOOO 3110 1
DN4-800 - 3 Pole CM91161OOUO 16600 Set of 6
DN2 - 160A CM99949OOOO 4470 1
DN4-1000 - 3 Pole CM91161OOVO 24500 Set of 6
DN2 - 250A CM99950OOOO 4470 1
DN4-1250 - 3 Pole CM91161OOAO 68300 Set of 6
DN3 - 400A CM99954OOOO 9130 1
DN0-100 - 4 Pole CM97921OOOO 1200 Set of 8
DN3 - 630A CM99955OOOO 9130 1
DN0-125D - 4 Pole CM90688OOLO 1310 Set of 8
DN4 - 800A CM99889OOOO 14000 1
DN1, DN2 - 250 - 4 Pole CM92007OOOO 3980 Set of 8
DN4 - 1000A CM99890OOOO 14600 1
DN3B/DN3-400 - 4 Pole ST98066OOOO 7910 Set of 8
DN4 - 1250A CM99891OOOO 16200 1
DN3-630 - 4 Pole CM92004OOOO 8250 Set of 8
Adaptor kit for External Neutral CT [8538]
DN4-800- 4 Pole ST90362OOOO 21300 Set of 8
DN2 - 250 CM99994OOOO 1410 Set of 2
DN4-1000- 4 Pole CM90064OOVO 32300 Set of 8
DN3 - 400 CM99995OOOO 2600 Set of 2
DN4-1250 - 4 Pole ST98058OOOO 87200 Set of 8
DN3 - 630 CM99997OOOO 2850 Set of 2
Mechanical Interlock Kit - Base Plate [8538]
DN4 - 800 CM99996OOOO 6990 Set of 2
DN2-250 CM99731OOOO 11000 1
DN4 - 1000 CM90966OOOO 14800 Set of 4
DN3-400 CM99732OOOO 16800 1
DN4 - 1250 CM99998OOOO 25400 Set of 2
DN3-630 CM99854OOOO 18000 1
DIN rail kit [8538]
DN0 CM90944OOOO 250 1
Note:
Phase Barriers are supplied along with MCCBs
Lauritz Knudsen, 15.08.2026 63PDF page 71 DU/DY MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DU/DY MCCB Range [8536]
DU/DY with Thermal - Magnetic Release :
Rating (A)
16 20 25 32 40 50 63 80 100 125 160 200 250 320 400
Icu (kA)
10 DY125U DY250U1
18 DU100D DU125D
DU250C
25
DU100H DU125H
30
DU250
36
DU400N
50
DY125U MCCBs
› Conforms to IS/IEC 60947-2, › No Load-Line Bias
IEC 60947-2 & EN 60947-2 › ON-TRIP-OFF indication
› Range: 16A to 125A, 2P/3P/4P › Suitable for Isolation
› Ics=100% of Icu › Common SS Enclosure for 3P & 4P
› High Electrical & Mechanical life
› Thermal Magnetic Release
Current Breaking 2 Pole Breaking 3 Pole 4 Pole Std.
Type Rating Capacity M.R.P. (`) Capacity M.R.P. (`) M.R.P. (`) Pkg.
(A) Icu (kA) Cat. No. Icu (kA) Cat. No. Cat. No. (Nos.)
Per Unit Per Unit Per Unit
16 EM90982OOBO 2900 EM90983OOBO 3410 EM90984OOBO 4590 1
20 EM90982OOCO 2900 EM90983OOCO 3410 EM90984OOCO 4590 1
25 EM90982OODO 2900 EM90983OODO 3410 EM90984OODO 4590 1
32 EM90982OOEO 2900 EM90983OOEO 3410 EM90984OOEO 4590 1
AC : 25kA AC : 10kA
40 EM90982OOFO 2900 EM90983OOFO 3410 EM90984OOFO 4590 1
@ 240V AC, @ 415V AC,
50 50 Hz/60 Hz EM90982OOGO 2900 50 Hz/60 Hz EM90983OOGO 3410 EM90984OOGO 4590 1
DY125U DC : 10kA DC : 10kA EM90983OOHO
63 EM90982OOHO 2820 3310 EM90984OOHO 4460 1
@ 250V DC @ 250V DC
(2P in series) EM90982OOJO 3100 (3P in series) EM90983OOJO 3730 EM90984OOJO 5150 1
80
EM90812OOJO 2820 EM90813OOJO 3310 EM90814OOJO 4460 1
EM90982OOKO 3100 EM90983OOKO 3730 EM90984OOKO 5150 1
100
EM90812OOKO 2820 EM90813OOKO 3310 EM90814OOKO 4460 1
125 EM90982OOLO 4330 EM90983OOLO 5480 EM90984OOLO 6720 1
- Spreader Terminals are included
Note: 2 Pole in 3 Pole frame size
Phase barriers are supplied with all MCCBs
Accessories for DY125U MCCBs [8538]
Auxiliary/Trip Alarm Contact Shunt Release Spreader Terminals Direct ROM Extended ROM
Internal External
Description M.R.P. Std. Description M.R.P. Std.
Cat. No. (`) Pkg. Cat. No. (`) Pkg.
Per Unit (Nos.) Per Unit (Nos.)
Auxiliary/Trip Alarm Contact Spreader Terminals
1C/O EM90966OOOO 1150 1 2 Pole (upto 100A) CM97785OOO2 460 Set of 4
Shunt Release 3 Pole (upto 100A) CM97785OOOO 770 Set of 6
Short Rated 110/240/415V AC EM90520OMOO 1560 1 4 Pole (upto 100A) CM97921OOOO 1200 Set of 8
Under Voltage Release Rotary Handle
240V AC EM90518BOOO 4690 1 Direct ROM EM90969OOOO 2130 1
Extended ROM EM90970OOOO 3060 1
SS Enclosure
Size I Enclosure for 3P & 4P CM90996OOOO 4110 1
Lauritz Knudsen, 15.08.2026 64PDF page 72 DU MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DU MCCB Range [8536]
3 Pole / 4 Pole MCCBs
DU100D/DU125D MCCBs
› Conforms to IS/IEC 60947-2 & IEC 60947-2 › Common SS Enclosure for 3P & 4P
› Range: 20A to 125A, 3P & 4P › Wide Range of snap fit Internal and
› Ics=100% of Icu External Accessories
› Compact size › Adjustable Overload Setting: 0.8 - 1.0 x In
Thermal Breaking Capacity 3 Pole 4 Pole Std.
Type Release Icu at 415V AC M.R.P. M.R.P. Pkg.
Range (A) 50Hz. (kA) Cat. No. (`) Cat. No. (`) (Nos.)
Per Unit Per Unit
16-20 CM90517OOCO 6920 CM90518OOCO 8480 1
20-25 CM90517OODO 6920 CM90518OODO 8480 1
25-32 CM90517OOEO 6920 CM90518OOEO 8480 1
32-40 CM90517OOFO 6920 CM90518OOFO 8480 1
DU100D 40-50 18 CM90517OOGO 6920 CM90518OOGO 8480 1
Note:
50-63 CM90517OOHO 6720 CM90518OOHO 8230 1 DIN rail kit available as
63-80 CM90517OOJO 6720 CM90518OOJO 8230 1 an accessory. Please refer
DU100D/DU125D
80-100 CM90517OOKO 6720 CM90518OOKO 8230 1
accessories table.
DU125D 100-125 CM90676OOLO 8140 CM90677OOLO 10200 1
2 Pole / 3 Pole / 4 Pole MCCBs
DU100H/DU125H MCCBs
› Conforms to IS/IEC 60947-2 & IEC 60947-2 › Wide Range of snap fit Internal and External
› Range: 20A to 125A, 2P, 3P & 4P Accessories
› Compact size › Adjustable Overload Setting: 0.8 - 1.0 x In
› Common SS Enclosure for 2P, 3P & 4P
Thermal Breaking 2 Pole Breaking 3 Pole 4 Pole Std.
Type Release Capacity M.R.P. Capacity M.R.P. M.R.P. Pkg.
Icu (kA) Cat. No. (`) Icu at 415V AC Cat. No. (`) Cat. No. (`)
Range (A) (Nos.)
Per Unit 50Hz. (kA) Per Unit Per Unit
16-20 CM97898OOC2 5560 CM97894OOC2 7770 CM97933OOC2 10300 1
20-25 CM97898OOD2 5560 CM97894OOD2 7770 CM97933OOD2 10300 1
25-32 AC : 65kA @ CM97898OOE2 5560 CM97894OOE2 7770 CM97933OOE2 10300 1
240V AC, 50Hz
32-40 CM97898OOF2 5560 CM97894OOF2 7770 CM97933OOF2 10300 1
DU100H
40-50 DC : 15kA @ CM97898OOG2 5560 30 CM97894OOG2 7770 CM97933OOG2 10300 1
50-63 250V DC, CM97898OOH2 5400 CM97894OOH2 7540 CM97933OOH2 10000 1
(2P in Series)
63-80 L/R < 15 msec. CM97898OOJ2 5400 CM97894OOJ2 7540 CM97933OOJ2 10000 1
80-100 CM97898OOK2 5400 CM97894OOK2 7540 CM97933OOK2 10000 1
DU125H 100-125 CM91198OOLO 8380 CM90678OOLO 8780 CM90679OOLO 11400 1
Note: 2 Pole in 3 pole frame size DIN rail kit available as an accessory. Please refer DU100H/DU125H accessories table.
Accessories for DU100D/DU125D/DU100H/DU125H MCCBs [8538]
Auxiliary Contact ATAC Shunt Release UV Release Spreader Terminals Direct ROM Extended ROM
Internal External
Description M.R.P. (`) Std. Pkg. Description M.R.P. (`) Std. Pkg.
Cat. No. (Nos.) Cat. No. (Nos.)
Per Unit Per Unit
Auxiliary Contact Spreader Terminals
1 C/O - Right CM97886OOOO 1650 1 DU100H - 2 Pole CM97785OOO2 460 Set of 4
2 C/O - Right CM97887OOOO 2910 1 DU125H - 2 Pole CM91199OOLO 580 Set of 4
Trip Alarm Contact DU100D/DU100H - 3 Pole CM97785OOOO 770 Set of 6
1 C/O - Right CM97888OOOO 1650 1 DU125D/DU125H - 3 Pole CM90687OOLO 900 Set of 6
2 C/O - Right CM97889OOOO 2910 1 DU100D/DU100H - 4 Pole CM97921OOOO 1200 Set of 8
Auxiliary + Trip Alarm Contact DU125D/DU125H - 4 Pole CM90688OOLO 1310 Set of 8
1 C/O + 1C/O - Right CM97890OOOO 2800 1 Rotary Handle
Shunt Release DU100D/DU125D/ Direct ROM CM97895OOOO 2100 1
24V DC - Left CM91402O4OO 3260 1 DU100H/DU125H Extended ROM CM97896OOOO 2720 1
110V AC - Left CM97883OAOO 3260 1 DIN rail kit
240/415V AC - Left CM97883OMOO 3260 1 DU100D/DU125D/DU100H/DU125H CM90944OOOO 250 1
Under Voltage Release SS Enclosure
240V AC - Left CM97892BOOO 5400 1 Size I Enclosure CM90996OOOO 4110 1
Note: Phase Barriers are supplied along with all MCCBs
Lauritz Knudsen, 15.08.2026 65PDF page 73 DU/DY MCCB Range [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DU/DY MCCB Range [8536]
2 Pole / 3 Pole / 4 Pole MCCBs
DY250U1/DU250C/DU250/DU400N MCCBs
› Conforms to IS/IEC 60947-2 & IEC 60947-2
› Range: 160A to 400A, 2P, 3P & 4P
› Common SS Enclosure for 2P, 3P & 4P*
› Compact size
› Wide Range of snap fit Internal and External Accessories
› Adjustable Overload Setting: 0.8 - 1.0 x In
Thermal 2 Pole Breaking 3 Pole 4 Pole Std.
Type Breaking Capacity M.R.P. Capacity M.R.P. M.R.P.
Release Pkg.
Icu (kA) Cat. No. (`) Icu (kA) Cat. No. (`) Cat. No. (`)
Range (A) (Nos.)
Per Unit Per Unit Per Unit
125-160 CM98195OOMO 10600 CM98196OOMO 13100 1
DY250U1 160-200 10 CM98195OONO 11300 CM98196OONO 14600 1
200-250 CM98195OOPO 14600 CM98196OOPO 19700 1
125-160 CM90631OOMO 11900 CM90634OOMO 15200 1
DU250C 160-200 25 CM90631OONO 14400 CM90634OONO 18300 1
200-250 CM90631OOPO 15800 CM90634OOPO 20900 1
125-160 CM90905OOMO 10400 CM98062OOOO 13800 CM98065OOMO 17100 1
DU250 160-200 AC : 65kA @ 240V AC, 50Hz CM90905OONO 12000 36 CM98061OOOO 16900 CM98065OONO 22900 1
DC : 15kA for DU250 @250V DC
200-250 CM90905OOPO 13400 CM98060OOOO 19000 CM98065OOPO 25100 1
& 25kA for DU400N @ 250V DC,
250-320 (2P in Series) L/R < 15 msec. CM90886OOQO 26400 CM98402OOQO 30900 CM98404OOQO 38000 1
DU400N 50
320-400 CM90886OORO 26400 CM98402OORO 30900 CM98404OORO 38000 1
- Spreader Terminals are included
Note: 2 Pole in 3 Pole frame size * For DU250/DU250C
Accessories for DY250U1/DU250/DU250C MCCBs [8538]
Internal External
Description M.R.P. (`) Std. Pkg. Description Cat. No. M.R.P. (`) Std. Pkg.
Cat. No. (Nos.) (Nos.)
Per Unit Per Unit
Auxiliary Contact Spreader Terminals
1 C/O - Right CM97886OOOO 1650 1 DU250 - 2 Pole CM90960OOOO 2340 Set of 4
2 C/O - Right CM97887OOOO 2910 1 DU250C/DU250 - 3 Pole ST98053OOOO 3000 Set of 6
Trip Alarm Contact DU250C/DU250 - 4 Pole CM92007OOOO 3980 Set of 8
1 C/O - Right CM97888OOOO 1650 1 Rotary Handle
2 C/O - Right CM97889OOOO 2910 1 Direct ROM CM98040OOOO 2260 1
Auxiliary + Trip Alarm Contact Extended ROM CM98041OOOO 2900 1
1 C/O + 1C/O - Right CM97890OOOO 2800 1 SS Enclosure
Shunt Release Size II Enclosure CM91003OOOO 9440 1
24V DC - Left CM91402O4OO 3260 1 Note: Phase Barriers are supplied along with all MCCBs
110V AC - Left CM97883OAOO 3260 1
240/415V AC - Left CM97883OMOO 3260 1
Under Voltage Release
240V AC - Left CM97892BOOO 5400 1
Accessories for DU400N MCCBs [8538]
Auxiliary Contact TAC Shunt Release UV Release Spreader Terminals Direct ROM Extended ROM
Internal External
Description M.R.P. (`) Std. Pkg. Description M.R.P. (`) Std. Pkg.
Cat. No. (Nos.) Cat. No. (Nos.)
Per Unit Per Unit
Auxiliary Contact Spreader Terminals
1 C/O CM99801OOOO 1920 1 2 Pole CM90964OOOO 3610 Set of 4
2 C/O CM99802OOOO 3710 1 3 Pole ST98065OOOO 5520 Set of 6
Trip Alarm Contact 4 Pole ST98066OOOO 7910 Set of 8
1 C/O - Right CM99803OOOO 2010 1 Rotary Handle
Auxiliary + Trip Alarm Contact Direct ROM CM99860OOOO 3480 1
1 C/O + 1C/O - Right CM99804OOOO 3710 1 Extended ROM CM99861OOOO 5720 1
Shunt Release
Note:
110/240/415V AC, 220V DC CM99805OOOO 4800@ 1 Phase Barriers are supplied along with all MCCBs
24V DC CM98976O4OO 4800@ 1 All internal accessories & ROMs are common for 2P MCCBs
@
- ‘NO’ of control contactor to be connected in series for DC control supply
Under Voltage Release
240V AC - Left CM99986BOOO 6680 1
Lauritz Knudsen, 15.08.2026 66PDF page 74 SS Enclosure for MCCBs [8538]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
SS Enclosure for MCCBs [8538]
Perfect home for your MCCB
Separate cable
gland box
Suitable to NOT required
accommodate › Superior Aesthetics
185 sq. mm. 3 1/2 core › Common Enclosure for 3P and 4P MCCBs
Aluminum
› Generous space for cable termination
armoured cable
› In-built neutral Link for TPN system
› IK08 and IP30 Protection
› Mounting holes for easy wall mounting
Suitable to › Louvers for better heat dissipation
accommodate › Effortless Installation
70 sq. mm. 3 1/2 core › Size I suitable up to 125A MCCBs, 36kA
Aluminum
armoured cable › Size II suitable from 160A to 250A MCCBs, 50kA
M.R.P. Std.
Description Cat. No. (`) Pkg.
Per Unit (Nos.)
Size I Enclosure for DU100H/DU125H/
CM90996OOOO 4110 1
DU100D/DU125D/DN0/DY125U
Size II Enclosure for
CM91003OOOO 9440 1
DY250U1/DU250C/DU250/DN1
Size I & Size II Enclosures
Easy wall Mounting In-built Neutral Link Better Heat Dissipation
Note:
Pictorial is for representation purpose only.
Does not include cabling. MCCB to be purchased separately.
Ground Fault Module [8538]
› Provides protection against ground fault
› GF Module for ground fault protection can be used with all
Thermal Magnetic MCCBs
› Adjustable ground fault sensitivity selection: 10% - 50% of In
› Adjustable time delay: 100ms / 200ms
› Test facility to check healthiness of ground fault protection
system without tripping MCCB
› Suitable for 3 phase 3 wire & 3 phase 4 wire electrical
distribution network with cable termination
› LED for earth fault indication
Ground Fault Protection
Std.
Range M.R.P. (`)
Type Cat. No. CT Pkg.
(A) Per Unit
(Nos.)
GF1 100 - 200A ST27745OOOO 16400 Built in CBCT 1
GF2 200 - 400A ST27746OOOO 24200 Built in CBCT 1
GF11 up to 800A ST28594OOOO 14600# External CT required 1
#
External CTs of 5P10 class with secondary rating of 1A or 5A
Lauritz Knudsen, 15.08.2026 67PDF page 75 SMDBs for Power Distribution [8537]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
SMDBs for Power Distribution [8537]
Metering Extension Box Range Highlights
› Sub Main Distribution Board (SMDB) with MCCB as incomer
and MCCBs as outgoing devices
Corner Box
Corner Box › Conforms to IEC 61439-2
› DEKRA and ASTA certified
› Rating up to 630 A
› Short-time withstand current
» 250A & 400A SMDB - 36 kA 1s
Side Cabling Box Side Cabling Box » 630A SMDB - 50 kA 1s
› Ingress protection - IP 43
› Choice in number of outgoing ways - 4, 8, 12 and 16
› Ready to use, off the shelf solution
› Suitable for range of MCCBs
Corner Box › Metering & cabling extensions are available as accessories
Corner Box
Bottom Cabling Box
SMDB
No of ways Height (H) Width (W) Depth (D)
Description Cat. No. M.R.P. (`)
250A Per Unit (mm) (mm) (mm)
100A
SMDB - TN250D, O/G 100A 4 ways DA20D1044CZZ0 - 4 56450 637 670 208.5
SMDB - TN250D, O/G 100A 8 ways DA20D1084CZZ0 - 8 68655 787 670 208.5
SMDB - TN250D, O/G 100A 12 ways DA20D1124CZZ0 - 12 86355 937 670 208.5
SMDB - TN250D, O/G 100A 16 ways DA20D1164CZZ0 - 16 101490 1087 670 208.5
SMDB - TN400D, O/G 100A 4 ways DA40D1044CZZ0 - 4 63250 937 670 208.5
SMDB - TN400D, O/G 100A 8 ways DA40D1084CZZ0 - 8 72070 1087 670 208.5
SMDB - TN400D, O/G 100A 12 ways DA40D1124CZZ0 - 12 92670 1237 670 208.5
SMDB - TN400D, O/G 100A 16 ways DA40D1164CZZ0 - 16 109225 1387 670 208.5
SMDB - TN630D, O/G 100A 8 ways DA60D1084CZZ0 - 8 119500 1287 870 208.5
SMDB - TN630D, O/G 100A 12 ways DA60D1124CZZ0 - 12 161385 1507 870 208.5
SMDB - TN630D, O/G 100A 16 ways DA60D1164CZZ0 - 16 176900 1507 870 208.5
SMDB - TN630D, O/G 250A 4 ways DA62D1044CZZ0 4 - 116380 1067 870 208.5
SMDB - TN630D, O/G 250A 8 ways DA62D1084CZZ0 8 - 130345 1287 870 208.5
SMDB - TN630D, O/G 250A 12 ways DA62D1124CZZ0 12 - 167590 1507 870 208.5
SMDB - TN630D, O/G 250A 16 ways DA62D1164CZZ0 16 - 187765 1727 870 208.5
SMDB - TN630D, O/G COMBI 4 ways DA6AD1044CZZ0 2 2 114055 1067 870 208.5
SMDB - TN630D, O/G COMBI 8 ways DA6AD1084CZZ0 2 6 124140 1287 870 208.5
SMDB - TN630D, O/G COMBI 12 ways DA6AD1124CZZ0 2 10 164485 1507 870 208.5
SMDB - TN630D, O/G COMBI 16 ways DA6AD1164CZZ0 2 14 181550 1507 870 208.5
Incoming Device [8536] Outgoing Device [8536]
SMDB M.R.P. SMDB M.R.P.
Description Cat. No. (`) Description Cat. No. (`)
Type Type
Per Unit Per Unit
DN1-250C 3 Pole MCCB - 160A CM90638OOMO 21500 DN0-100C 3 Pole MCCB - 20A CM91612OOCOOG 12100
TN250D* DN1-250C 3 Pole MCCB - 200A CM90638OONO 27500 DN0-100C 3 Pole MCCB - 25A CM91612OODOOG 12100
DN1-250C 3 Pole MCCB - 250A CM90638OOPO 32200 DN0-100C 3 Pole MCCB - 32A CM91612OOEOOG 12100
TN250D,
DN3-400D 3 Pole MCCB - 320A CM94005OOQ1OG * TN400D DN0-100C 3 Pole MCCB - 40A CM91612OOFOOG 12100
TN400D
DN3-400D 3 Pole MCCB - 400A CM94005OOR1OG * & DN0-100C 3 Pole MCCB - 50A CM91612OOGOOG 12100
TN630D
DN3-630D 3 Pole MCCB - 500A CM94006OOS1OG 73400 DN0-100C 3 Pole MCCB - 63A CM91612OOHOOG 11700
TN630D
DN3-630D 3 Pole MCCB - 630A CM94006OOT1OG 73400 DN0-100C 3 Pole MCCB - 80A CM91612OOJOOG 11700
Note: DN0-100C 3 Pole MCCB - 100A CM91612OOKOOG 11700
› While ordering SMDB, incoming and outgoing MCCBs have to be ordered DN1-250C 3 Pole MCCB - 160A CM90638OOMO 21500
separately. TN630D DN1-250C 3 Pole MCCB - 200A CM90638OONO 27500
› Prices of MCCBs are not included in SMDB prices. DN1-250C 3 Pole MCCB - 250A CM90638OOPO 32200
* TN250D - Suitable for DN1-250N, DU250 & DU250C MCCB as incomer.
## Price on Request. DN0, DU100D & DU100H MCCBs are suitable as outgoing devices up to 100A
DN1-250N, DU250 & DU250C MCCBs are suitable as outgoing devices up to 250A
Lauritz Knudsen, 15.08.2026 68PDF page 76 SMDB Accessories [8537]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
SMDB Accessories [8537]
Metering, Bottom Cabling & Corner Box
› Provision of 3 nos of 1-phase ammeter (96*96), 1 nos of 1-phase
voltmeter (96*96) with selector switch and indicating lamps.
SMDB M.R.P.
Description Cat. No. (`)
Type
Per Unit
TN250D & Metering Extension Box CM90439OOPO 8715
TN400D Bottom Cabling Box CM90437OOOO 8170
Metering Extension Box CM91064OOTO 9190
TN630D
Bottom Cabling Box CM91062OOOO 8640
TN250D, TN400D & Corner Box CM91089OOOO 3035
TN630D Mounting base CM70260OOOO 4095
Note:
› Ammeter, voltmeter, selector switch and indicating lights have to be ordered separately.
› Mounting base to be used without bottom cabling box.
Side Cabling Box
No. of Ways Left Right
SMDB
Type M.R.P. (`) M.R.P. (`)
250A 100A Cat. No. Cat. No.
Per Unit Per Unit
- 4 CM91085ODOO 8360 CM91086ODOO 8360
- 8 CM91085OFOO 10795 CM91086OFOO 10795
TN250D
- 12 CM91085OHOO 12935 CM91086OHOO 12935
- 16 CM91085OKOO 15100 CM91086OKOO 15100
- 4 CM91087ODOO 12935 CM91088ODOO 12935
- 8 CM91087OFOO 15100 CM91088OFOO 15100
TN400D
- 12 CM91087OHOO 16540 CM91088OHOO 16540
- 16 CM91087OKOO 18690 CM91088OKOO 18690
- 8 CM91120OOFO 15665 CM91121OOFO 15665
- 12
CM91120OOHO 18250 CM91121OOHO 18250
- 16
4 - CM91120OODO 14040 CM91121OODO 14040
8 - CM91120OOFO 15665 CM91121OOFO 15665
TN630D 12 - CM91120OOHO 18250 CM91121OOHO 18250
16 - CM91120OOKO 19885 CM91121OOKO 19885
2 2 CM91120OODO 14040 CM91121OODO 14040
2 6 CM91120OOFO 15665 CM91121OOFO 15665
2 10
CM91120OOHO 18250 CM91121OOHO 18250
2 14
Lauritz Knudsen, 15.08.2026 69PDF page 77 Introducing Lauritz Knudsen's
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Introducing Lauritz Knudsen's
FIRST SERVE PROGRAM
Peace of Mind with Priority Service for our Air Circuit Breaker
Avail Exclusive Benefits Under "FIRST SERVE" Program
for Our Air Circuit Breakers in India
› Priority Service: Enjoy expedited
service for our ACB.
Benefits
› Expert Support: Receive guidance and
technical assistance from our team.
› Peace of Mind: Rest assured knowing
our ACB is in good hands.
C-POWER Eligibility
› ACB should be within
the warranty period.
To learn more about the First Serve Program or
to schedule our ACB’s first service visit, please contact
Customer Connect Hub
at +91-22-6932-7800PDF page 78 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 79 Air Circuit Breakers
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Air Circuit Breakers
Range of Air Circuit Breakers
› Complete range conforms to IS/IEC 60947-2 & IEC 60947-2
› Current Rating from 400A to 6300A in 3 Frame sizes for application voltages upto 690V AC
› Special ACB range available for Voltage Applications upto 800V AC and 1000V AC#
› Available in 3 Pole/4 Pole, Manually & Electrically operated, Fixed/Draw-out version
› Common Height & Depth across the range
› High short time fault withstand capacity, Icu = Ics = Icw for 1 sec for total selectivity
› High mechanical and electrical operating life
› Neutral pole is 100% rated, option of 50% & 200% rated neutral also available
› Available in standard NRYB & RYBN/NBYR/BYRN configurations in 4 Pole ACBs with on-site
change facility
› In-built Electrical & Mechanical Anti-Pumping
› Modular & snap-fit accessories
› Ease of on-site conversion from Fixed to Draw-out version
› Pollution Degree 4 suitability
› Best in Class Overlap with Bus bars
› Break Time of 25msec
› RoHS Compliant
Matrix Protection & Control Units:
› Available in versions - MTX1.0/1G/1Gi/1.5G/1.5Gi,
MTX3.5/3.5EC/3.5H & MTX 3.5T/MTX 3.5ET/3.5A
› Unique O-LED display for metering
› Unique withdrawable Communication & Power metering modules
› Dual protection curve settings & Password protection
› Soft-rating plug for precise protection at lower load currents UW-MTX1G/1Gi UW-MTX1.5G/1.5Gi UW-MTX3.5/3.5EC/3.5H
› Provision for on-load self-diagnosis of Releases & modules
› Data communication on Modbus RTU, Modbus TCP/IP (ETHERNET),
Profibus & wireless Zigbee protocols
› Power & Harmonics measurement
› Temperature rise monitoring & protection
› Easy to integrate with HMI & PLC
› Add-on modules for advance protections
› Protection Releases conform to EMI/EMC standard
Breaking Capacities Offered: New Integrated MODBUS TCP/IP (ETHERNET) Communicable ACB
at 415V/440V AC (Please refer Catalogue for Breaking Capacities above 440V AC)
Icu = Ics = Icw for 1 sec
Rated current 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6300A
N : 50kA
Frame-1
S : 65kA
H : 80kA
UW1-08 UW1-10 UW1-12 UW1-16 UW1-20 UW1-25
N : 50kA
Frame-2
S : 65kA
H : 80kA
UW2-08 UW2-10 UW2-12 UW2-16 UW2-20 UW2-25 UW2-32 UW2-40
H : 80kA
Frame-3
V : 100kA
UW3-08 UW3-10 UW3-12 UW3-16 UW3-20 UW3-25 UW3-32 UW3-40 UW3-50 UW3-63
Note: 400A & 630A ACBs are also available on request. # Please contact the nearest branch office for more details of 1000V AC ACBs
Lauritz Knudsen, 15.08.2026 72PDF page 80 Air Circuit Breakers
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Air Circuit Breakers
ACB ordering information:
UW 1 08 N X D 1 2 9 0 0# UW1 800N 3P ED 1.5G BotV
Selection for Termination (For Drawout ACBs Only)
Standard Termination 0
Frame Size
For Top Horizontal (Long), Bottom Vertical for Fr2 & Fr3 X
Frame - I 1
For Top & Bottom Horizontal (Long) for Fr3 Y
Frame - II 2
Note: X is applicable for 4000A (Fr2 & Fr3) and 5000A (Fr3).
Frame - III 3 Y is applicable for 4000A (Fr3) & 5000A (Fr3).
X & Y recommended for Buscoupler only.
For 800V AC Application ZM
For 1000V AC Application ZH
Current Ratings
Temperature Rise Monitoring(3)
400A 04
Not Required 0
630A 06
Required 1
800A 08
Type Selection for P&C Units
1000A 10
Manually Operated 1 B/C (w/o protection) 0
1250A 12
Electrically Operated 2 UW - MTX1.0 7
1600A 16
UW - MTX1G 8
2000A 20
UW - MTX1Gi B
2500A(4) 25 Version UW - MTX1.5G 9
3200A 32 Draw-out D UW - MTX1.5Gi C
4000A 40 Fixed F UW-MTX3.5 3
5000A 50 (5) 4
Cradle/Fixed Part
(7)
C UW-MTX3.5EC
6300A 63 Breaker/Moving Part B UW-MTX4.5 5
UW-MTX3.5H 6
New UW-MTX3.5T (8) D
New UW-MTX3.5ET (8) E
Selection for Breaking Capacity (Icu=Ics)(1)
New UW-MTX4.5T (8) F
50kA (Fr-I upto 2000A & Fr-II upto 4000A) N
New UW-MTX3.5A(6) K
65kA (Fr-I & Fr-II) S
80kA (Fr-l, Fr-II & Fr-III) H
100kA (Fr-III) V Selection for control voltage(2)
For Manually Operated 0
Please Note:
(1)
For Icw values please refer technical specification 240V AC/DC ECD & CR + 240V AC/DC SR 1
(2)
Other options of control voltage are available as accessory 240V AC/DC ECD & CR + 24V DC SR 2
(3)
Temperature monitoring & protection is available only for Drawout 110V AC/DC ECD & CR + 110V AC/DC SR 3
type ACBs with MTX3.5 Series & above releases 240V AC/DC ECD & CR + 110V AC/DC SR 4
(4)
For Fr-1, 2500A selection, please contact the nearest branch office
(5)
For system requiring 690V metering, kindly order separate Selection for No. of Poles
Power Metering module with MTX3.5. 3 Pole X
(6)
For MTX3.5A technical specifications please get in touch with the local sales team
4 Pole 100% N F
(7)
For Cradle Cat Number last 5 digits shall be "00000" of any combination
(8)
MODBUS TCP/IP (Ethernet) ready ACB as an Integrated Release Offering 4 Pole 50% N (in Fr-III only) H
4 Pole 200% N (upto 2500A) D
ACBs are offered with following standard features
Draw-out Version: OMEGA ACBs with UW-MTX release will have inbuilt-
Current Metering (MTX 1.5G/1.5Gi/3.5 Series/4.5 Series), Common Fault Indication microswitch,
4NO+4NC Aux. contacts, Smart-racking shutter, Safety shutter assembly, Racking Handle, Door sealing
frame, Pad-locking arrangement for ON/OFF button, Rating Error Preventer, Arc shield.
A) For ratings upto 1600A, one side vertical terminal adaptors (Bottom) for Frame 1, 2 & 3.
B) For ratings 2000A & above, both side vertical terminal adaptors (Top & Bottom) for Frames 1, 2 & 3.
C) For rating 4000A and above operation counter inbuilt for Frames 2 & 3 both.
Fixed Version: OMEGA ACBs with UW-MTX release will have inbuilt-
Current Metering (MTX 1.5G/1.5Gi/3.5 Series/4.5 Series), Common Fault Indication microswitch,
4NO+4NC Aux. contacts, Door sealing frame & Pad-locking arrangement for ON/OFF push button.
A) For ratings upto 1600A, one side vertical terminal adaptors (Bottom) for Frames 1, 2 & 3.
B) For ratings 2000A & above, both side vertical terminal adaptors (Top & Bottom) for Frames 1, 2 & 3.
C) For ratings 4000A & above, operation counter inbuilt for Frames 2 & 3 both.
# Please contact the nearest branch office for more details of 800V & 1000V AC ACBs
Lauritz Knudsen, 15.08.2026 73PDF page 81 Air Circuit Breakers
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Air Circuit Breakers
ACBs upto 690V AC with UW-MTX1G (LSING - BCD Switches) and
UW-MTX1.5G (LSING + Current Metering - BCD Switches) [8536]
3 Pole Manual Draw-out ACB 4 Pole Manual Draw-out ACB
Breaking
Current Capacity UW-MTX1G UW-MTX1.5G UW-MTX1G UW-MTX1.5G
Rating Version
@ M.R.P. M.R.P. M.R.P. M.R.P.
415V AC Cat. No. (`) Cat. No. (`) Cat. No. (`) Cat. No. (`)
Per Unit Per Unit Per Unit Per Unit
800A UW108NXD01800 322600 UW108NXD01900 343900 UW108NFD01800 402900 UW108NFD01900 424200
1000A UW110NXD01800 333400 UW110NXD01900 354700 UW110NFD01800 428500 UW110NFD01900 449800
1250A UW112NXD01800 367200 UW112NXD01900 388500 UW112NFD01800 463300 UW112NFD01900 484600
1600A UW116NXD01800 416200 UW116NXD01900 437500 UW116NFD01800 519100 UW116NFD01900 540400
MDO 50kA
2000A UW120NXD01800 507900 UW120NXD01900 529200 UW120NFD01800 610800 UW120NFD01900 632100
2500A UW225NXD01800 654900 UW225NXD01900 676200 UW225NFD01800 787500 UW225NFD01900 808800
3200A UW232NXD01800 782900 UW232NXD01900 804200 UW232NFD01800 961200 UW232NFD01900 982500
4000A UW240NXD01800 902100 UW240NXD01900 923400 UW240NFD01800 1097300 UW240NFD01900 1118600
3 Pole Manual Fixed ACB 4 Pole Manual Fixed ACB
Breaking
Current Capacity UW-MTX1G UW-MTX1.5G UW-MTX1G UW-MTX1.5G
Rating Version
@ M.R.P. M.R.P. M.R.P. M.R.P.
415V AC Cat. No. (`) Cat. No. (`) Cat. No. (`) Cat. No. (`)
Per Unit Per Unit Per Unit Per Unit
800A UW108NXF01800 248200 UW108NXF01900 269500 UW108NFF01800 309900 UW108NFF01900 331200
1000A UW110NXF01800 256500 UW110NXF01900 277800 UW110NFF01800 329600 UW110NFF01900 350900
1250A UW112NXF01800 282500 UW112NXF01900 303800 UW112NFF01800 356400 UW112NFF01900 377700
1600A UW116NXF01800 320200 UW116NXF01900 341500 UW116NFF01800 399300 UW116NFF01900 420600
MF 50kA
2000A UW120NXF01800 390700 UW120NXF01900 412000 UW120NFF01800 469800 UW120NFF01900 491100
2500A UW225NXF01800 503800 UW225NXF01900 525100 UW225NFF01800 605800 UW225NFF01900 627100
3200A UW232NXF01800 602200 UW232NXF01900 623500 UW232NFF01800 739400 UW232NFF01900 760700
4000A UW240NXF01800 693900 UW240NXF01900 715200 UW240NFF01800 844100 UW240NFF01900 865400
M.R.P. changes for product customization M.R.P. (`)
Per Unit
MDO to EDO or MF to EF Conversion kit (ECD + CR + SR) 88000
Buscoupler (without protection release)
UW-MTX1.0 (LSI - BCD Switches)
UW-MTX1Gi (LSING + Inbuilt ZSI - BCD Switches)
UW-MTX1.5Gi (LSING + Current Metering + Inbuilt ZSI - BCD Switches)
UW-MTX3.5 (LSING + Current Metering) + can be upgraded for Power Metering & Communication
UW-MTX3.5EC (LSING + Power Metering + Communication)
UW-MTX3.5H (LSING + Power Metering + Harmonic Metering) *
UW-MTX4.5 (LSING + Power Metering + Harmonic Metering + Communication with Touch Screen navigation + PS Module)
PS (Auxiliary power supply module for display in No-load or OFF condition)**$
COM Module (MODBUS) for communication$
PM Module for power metering$
New UW-MTX3.5T (LSING + Current Metering + MODBUS TCP/IP (ETHERNET) Communication) + can be upgraded for Power Metering#
New UW-MTX3.5ET (LSING + Power Metering +MODBUS TCP/IP (ETHERNET) Communication)#
* Available on request
** Applicable only for MTX 1Gi, MTX 1.5Gi & MTX 3.5 Series
# Integrated Release along with ACB - available as Factory-fitted option only
$ Chapter ID [8538]
Lauritz Knudsen, 15.08.2026 74PDF page 82 Air Circuit Breakers
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Air Circuit Breakers
3 Pole ACBs upto 690V AC with UW-MTX1G (LSING - BCD Switches) [8536]
3 Pole Manual Draw-out ACB with UW-MTX1G
Current S (65kA @ 415V AC) H (80kA @ 415V AC) V (100kA @ 415V AC)
Rating Version M.R.P. M.R.P. M.R.P.
Cat. No. (`) Cat. No. (`) Cat. No. (`)
Per Unit Per Unit Per Unit
800A UW108SXD01800 UW108HXD01800 UW308VXD01800
1000A UW110SXD01800 UW110HXD01800 UW310VXD01800
1250A UW112SXD01800 UW112HXD01800 UW312VXD01800
1600A UW116SXD01800 UW116HXD01800 UW316VXD01800
2000A UW120SXD01800 * UW120HXD01800 UW320VXD01800
2500A MDO UW225SXD01800 UW225HXD01800 * UW325VXD01800 *
3200A UW232SXD01800 UW232HXD01800 UW332VXD01800
4000A UW240SXD01800 UW240HXD01800 UW340VXD01800
4000A - - UW340HXD01800 UW340VXD01800
5000A - - UW350HXD01800 UW350VXD01800
6300A - - UW363HXD01800 UW363VXD01800
3 Pole Manual Fixed ACB with UW-MTX1G
800A UW108SXF01800 UW108HXF01800 UW308VXF01800
1000A UW110SXF01800 UW110HXF01800 UW310VXF01800
1250A UW112SXF01800 UW112HXF01800 UW312VXF01800
1600A UW116SXF01800 UW116HXF01800 UW316VXF01800
2000A UW120SXF01800 UW120HXF01800 UW320VXF01800
2500A MF UW225SXF01800 UW225HXF01800 UW325VXF01800
3200A UW232SXF01800 UW232HXF01800 UW332VXF01800
4000A UW240SXF01800 UW240HXF01800 UW340VXF01800
4000A - - UW340HXF01800 UW340VXF01800
5000A - - UW350HXF01800 UW350VXF01800
6300A - - * *
M.R.P. changes for product customization M.R.P. (`)
Per Unit
MDO to EDO or MF to EF Conversion kit (ECD + CR + SR) 88000
Buscoupler (without protection release)
UW-MTX1.0 (LSI - BCD Switches)
UW-MTX1Gi (LSING + Inbuilt ZSI - BCD Switches)
UW-MTX1.5G (LSING + Current Metering - BCD Switches)
UW-MTX1.5Gi (LSING + Current Metering + Inbuilt ZSI - BCD Switches)
UW-MTX3.5 (LSING + Current Metering) + can be upgraded for Power Metering & Communication
UW-MTX3.5EC (LSING + Power Metering + Communication)
UW-MTX3.5H (LSING + Power Metering + Harmonic Metering)
*
UW-MTX4.5 (LSING + Power Metering + Harmonic Metering + Communication with Touch Screen navigation + PS Module)
PS (Auxiliary power supply module for display in No-load or OFF condition)**$
COM Module (MODBUS) for communication$
PM Module for power metering$
New UW-MTX3.5T (LSING + Current Metering + MODBUS TCP/IP (ETHERNET) Communication) + can be upgraded for Power Metering#
New UW-MTX3.5ET (LSING + Power Metering +MODBUS TCP/IP (ETHERNET) Communication)#
* Available on request
** Applicable only for MTX 1Gi, MTX 1.5Gi & MTX 3.5 Series
# Integrated Release along with ACB - available as Factory-fitted option only
$ Chapter ID [8538]
Lauritz Knudsen, 15.08.2026 75PDF page 83 Air Circuit Breakers
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Air Circuit Breakers
4 Pole ACBs upto 690V AC with UW-MTX1G (LSING - BCD Switches) [8536]
4 Pole Manual Draw-out ACB with UW-MTX1G
Current S (65kA @ 415V AC) H (80kA @ 415V AC) V (100kA @ 415V AC)
Rating Version M.R.P. M.R.P. M.R.P.
Cat. No. (`) Cat. No. (`) Cat. No. (`)
Per Unit Per Unit Per Unit
800A UW108SFD01800 UW108HFD01800 UW308VFD01800
1000A UW110SFD01800 UW110HFD01800 UW310VFD01800
1250A UW112SFD01800 UW112HFD01800 UW312VFD01800
1600A UW116SFD01800 UW116HFD01800 UW316VFD01800
2000A UW120SFD01800 * UW120HFD01800 UW320VFD01800
2500A MDO UW225SFD01800 UW225HFD01800 * UW325VFD01800 *
3200A UW232SFD01800 UW232HFD01800 UW332VFD01800
4000A UW240SFD01800 UW240HFD01800 UW340VFD01800
4000A - - UW340HFD01800 UW340VFD01800
5000A - - UW350HFD01800 UW350VFD01800
6300A - - UW363HFD01800 UW363VFD01800
4 Pole Manual Fixed ACB with UW-MTX1G
800A UW108SFF01800 UW108HFF01800 UW308VFF01800
1000A UW110SFF01800 UW110HFF01800 UW310VFF01800
1250A UW112SFF01800 UW112HFF01800 UW312VFF01800
1600A UW116SFF01800 UW116HFF01800 UW316VFF01800
2000A UW120SFF01800 UW120HFF01800 UW320VFF01800
2500A MF UW225SFF01800 UW225HFF01800 UW325VFF01800
3200A UW232SFF01800 UW232HFF01800 UW332VFF01800
4000A UW240SFF01800 UW240HFF01800 UW340VFF01800
4000A - - UW340HFF01800 UW340VFF01800
5000A - - UW350HFF01800 UW350VFF01800
6300A - - * *
* Available on request
Accessories of Air Circuit Breakers [8538]
Terminal Adaptor configuration upto 690V AC
Draw-out ACBs Terminal Adaptors Fixed ACBs Terminal Adaptors
M.R.P. M.R.P.
Description Cat. No. (`) Description Cat. No. (`)
Per Unit Per Unit
Terminal Adaptor for Draw-out Omega ACBs Terminal Adaptor for Fixed Omega ACBs
Frame-1 400-1000A N/S/H (Vertical / Horizontal) CL60438OOOO Frame-1 400-2000A N/S (Vertical / Horizontal) CL60967OOOO
Frame-1 1250-2000A N/S/H (Vertical / Horizontal) CL60963OOOO Frame-1 400-2000A H (Vertical / Horizontal) CL60968OOOO
Frame-1 2500A S/H (Vertical) Frame-1 2500A S/H (Vertical) CL60976OOOO
CL60964OOOO
Frame-2 400-3200A N/S/H (Vertical / Horizontal) Frame-2 400-2500A N/S (Vertical / Horizontal) CL60122OOOO
Frame-2 4000A N/S/H (Vertical) CL60420OOOO Frame-2 400-3200A H, 3200A N/S (Vertical / Horizontal) CL60977OOOO *
*
Frame-2 4000A N/S/H (Horizontal) CL60316OOOO Frame-2 4000A S/H (Vertical) CL60417OOOO
Frame-3 400-4000A H/V (Vertical)# CL60128OOOO Frame-3 400-4000A H/V (Vertical)# CL60418OOOO
Frame-3 400-4000A H/V (Horizontal-Long) CL60073OOOO # CL60347OOOO
Frame-3 5000A H/V (Vertical)
Frame-3 5000A H/V (Horizontal-Long) CL60966OOOO Frame-3 400-5000A H/V (Horizontal-Long) CL60373OOOO
#
Frame-3 5000A H/V (Vertical) CL60067OOOO # : Please consider 4 terminal adaptors per phase.
Frame-3 6300A H/V (Vertical)# CL60965OOOO
# : Please consider 4 terminal adaptors per phase. Lauritz Knudsen, 15.08.2026 76PDF page 84 Air Circuit Breakers
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Air Circuit Breakers
800V AC ACBs with UW-MTX1G (LSING - BCD Switches) [8536]
Breaking Capacity @ 800V AC (Icu=Ics=Icw for 1s)
800V AC Manual Fixed/Draw-out ACB with UW-MTX1G
3P 4P
Breaking
Current Capacity Fixed Draw-out Fixed Draw-out
Frame
Rating @ M.R.P. M.R.P. M.R.P. M.R.P.
800V AC Cat. No. (`) Cat. No. (`) Cat. No. (`) Cat. No. (`)
Per Unit Per Unit Per Unit Per Unit
800A UW108NXF0180ZM UW108NXD0180ZM UW108NFF0180ZM UW108NFD0180ZM
1000A UW110NXF0180ZM UW110NXD0180ZM UW110NFF0180ZM UW110NFD0180ZM
1250A 1 50kA UW112NXF0180ZM * UW112NXD0180ZM * UW112NFF0180ZM * UW112NFD0180ZM *
1600A UW116NXF0180ZM UW116NXD0180ZM UW116NFF0180ZM UW116NFD0180ZM
2000A UW120NXF0180ZM UW120NXD0180ZM UW120NFF0180ZM UW120NFD0180ZM
2000A UW220NXF0180ZM UW220NXD0180ZM UW220NFF0180ZM UW220NFD0180ZM
2500A UW225NXF0180ZM UW225NXD0180ZM UW225NFF0180ZM UW225NFD0180ZM
2 50kA * * * *
3200A UW232NXF0180ZM UW232NXD0180ZM UW232NFF0180ZM UW232NFD0180ZM
4000A - UW240NXD0180ZM - UW240NFD0180ZM
3200A UW332NXF0180ZM UW332NXD0180ZM UW332NFF0180ZM UW332NFD0180ZM
4000A 3 50kA UW340NXF0180ZM * UW340NXD0180ZM * UW340NFF0180ZM * UW340NFD0180ZM *
5000A UW350NXF0180ZM UW350NXD0180ZM UW350NFF0180ZM UW350NFD0180ZM
3200A UW332SXF0180ZM UW332SXD0180ZM UW332SFF0180ZM UW332SFD0180ZM
4000A 3 65kA UW340SXF0180ZM * UW340SXD0180ZM * UW340SFF0180ZM * UW340SFD0180ZM *
5000A UW350SXF0180ZM UW350SXD0180ZM UW350SFF0180ZM UW350SFD0180ZM
Note: 1. Above mentioned Cat. No. of ACBs are without Terminal Adaptors. Please consider Terminal Adaptors from below table.
2. Phase-Barriers are mandatory to be used with 800V AC ACBs:
(a) For Draw-out ACBs, Phase-Barriers are provided as standard supply along with ACBs
(b) For Fixed ACBs, kindly consider Phase-Barriers from below table
M.R.P. changes for product customization M.R.P. (`) Per Unit
Buscoupler (without protection release)
UW-MTX1.0 (LSI - BCD switch for selection)
UW-MTX1G (LSING - BCD switch for selection)
UW-MTX1.5G (LSING + display - BCD switch for selection)
UW-MTX3.5 (LSING + Display + Option for other features) *
UW-TM - Temperature Rise Module ( for MTX3.5)
MDO to EDO or MF to EF Conversion kit (ECD + CR + SR)
COM Module (MODBUS) for communication
PS (Auxiliary power supply module for display in No-load or OFF condition)**
** Applicable only for MTX 1Gi, MTX 1.5Gi & MTX 3.5 Series
Terminal Adaptors for 800V ACBs [8538]
Fixed Draw-out
Current Draw-out ACBs Terminal Adaptors
Rating Frame M.R.P. Qty M.R.P. Qty
Cat. No. (`) (3P/4P) Cat. No. (`) (3P/4P)
Per Unit Per Unit
630A CL60967OOOO (6/8) CL60963OOOO (6/8)
800A CL60967OOOO (6/8) CL60963OOOO (6/8)
1000A CL60967OOOO (6/8) CL60963OOOO (6/8) Fixed ACBs Terminal Adaptors
1
1250A CL60967OOOO (6/8) CL60963OOOO (6/8)
1600A CL60967OOOO (6/8) CL60963OOOO (6/8) Phase-Barriers for 800V AC Fixed ACBs
2000A CL60122OOOO (6/8) CL60964OOOO (6/8) [8538]
2000A CL60977OOOO (6/8) CL60964OOOO (6/8)
* *
2500A 2 CL60318OOOO (6/8) CL60964OOOO (6/8) M.R.P. (`)
Cat. No. Type Pole Qty. per ACB
3200A CL60417OOOO (6/8) CL60419OOOO (6/8) Per Unit
4000A - - CL60420OOOO (6/8) CL91258OOOO Fixed 3P 2
3200A CL60418OOOO (12/16) CL60128OOOO (12/16) CL91259OOOO Fixed 4P * 2
4000A 3 (12/16) CL60067OOOO (12/16)
CL60418OOOO * Available on request
5000A CL60347OOOO (12/16) CL60965OOOO (12/16)
Note: Please contact the nearest branch office for more details of 1000V AC ACBs Lauritz Knudsen, 15.08.2026 77PDF page 85 Accessories of Air Circuit Breakers
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Accessories of Air Circuit Breakers
Operation Counter Door Interlock Closing Release Shunt Release UV Release
M.R.P. M.R.P.
Description Cat. No. (`) Description Cat. No. (`)
Per Unit Per Unit
Other Accessories [8538] Electrical Charging Device (ECD) [8501]
Operation Counter CL90983OOOO# 24-30V DC CL90362OOOO
Door Interlock CL90978OOOO 48/60V DC CL90363OOOO
*
Electrical Position Indication (EPI) CL95826OOOO 110V AC / 110-125V DC CL90360OOOO *
Microswitches for Indication [8536] 220V AC / 200V DC CL90364OOOO
240V AC / 250V DC CL90359OOOO
Microswitch for Common Fault Indication (CFI) CL90949OOOO
415V AC / 400V DC CL90361OOOO
Microswitch for Ready To Close Indication (RTC) CL90953OOOO^
Closing Release (CR) [8538]
Microswitch for Shunt Release CL90951OOOO * 24-30V DC CL908174OOO
Microswitch for Undervoltage Release CL90947OOOO
48/60V DC CL908175OOO
Microswitch for Spring Charging Indication ST42672OOOO
110V AC / 110V DC CL90817AOOO *
# Operation Counter inbuilt for rating 4000A to 6300A 125/127V DC CL908171OOO
^ Cradle SIC block CL95825OOOO needs to be ordered separately, 220 - 240V AC / 220 - 250V DC CL90817BOOO
If EPI not installed in same ACB
415V AC CL90817DOOO
Shunt Release (SR) [8538]
24-30V DC CL90816O4OO
48/60V DC CL90816O5OO
R-Lock C-Lock 110V AC / 110V DC CL90816OAOO
M.R.P. *
125/127V DC CL90816O1OO
Description Cat. No. (`)
Per Unit 220 - 240V AC / 220 - 250V DC CL90816OBOO
Mechanical Interlock using Key & Lock$ 415V AC CL90816ODOO
Under Voltage Release (UVR) with time delay (0-1-3-5 sec) [8538]
R - Lock Type - 1 CL00659OOOO
24-30V DC CL908184OOO
R - Lock Type - 2 CL00660OOOO
48V DC CL908185OOO
R - Lock Type - 3 CL00661OOOO
110V AC / 110V DC CL90818AOOO
R - Lock Type - 12 CL00662OOOO *
240V AC / 220V DC CL90818BOOO
R - Lock Type - 23 CL00663OOOO
415V AC CL90818DOOO
Locking arrangement for OFF button CL90815OOOO
with R - Lock (on breaker)
Neutral CT
Locking arrangement for ISO position
CL90865OOOO
with R - Lock (on Cradle)
Description Cat. No. M.R.P. (`)
Per Unit
Locking arrangement for ANY position CL90927OOOO
with R - Lock (on Cradle) External Neutral CT for UW-MTX Releases [8504]
*
C - Lock Type - S CL00664OOOO Frame-1, 2 & 3 400-800A CL00717OOOO
C - Lock Type - T CL00665OOOO Frame-1, 2 & 3 1000-1600A CL00718OOOO
C - Lock Type - ST CL00666OOOO Frame-1 2000-2500A CL00719OOOO *
C - Lock Type - SS CL00667OOOO Frame-2 & 3 2000-4000A CL00720OOOO
C - Lock Type - TT Frame-3 5000-6300A CL00721OOOO
CL00668OOOO
Locking arrangement for OFF button
with C - Lock (on breaker) CL90814OOOO Automatic Transfer
Controllers (ATC) [9032]
Locking arrangement for ISO position AuXC-2000 Controller
CL90982OOOO
for C - Lock (on Cradle)
M.R.P. (`) Std. Pkg.
Type Cat. No.
Per Unit (Nos.)
Locking arrangement for ANY position CL90981OOOO
with C - Lock (on Cradle) AuXC-2000 controller** ATC2000OOOO 52600 1
Can be used along with ACB, Motorised MCCBs, MCX contactors & Motorised
Note: For Mechanical Interlock using Key & Lock please order combination Changeover switches
of Lock and Locking arrangement. ** Note: For communication version of AuXC controller refer page no-6
* Available on request $ Only locks [8301] Locking arrangement [8538]
For AuXC 2000/2100 programming videos and more details
please scan the QR code or click here
Lauritz Knudsen, 15.08.2026 78PDF page 86 Accessories of Air Circuit Breakers
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Accessories of Air Circuit Breakers
MODBUS Module Power Metering Module
M.R.P.
Description Cat. No. (`)
Per Unit
MATRIX Releases & Modules [8538]
UW-MTX1.0 CL91966OOOO
UW-MTX1G CL91971OOOO
Mechanical Interlock using Bowden Cable [8538] UW-MTX1Gi CL90562OOOO
M.R.P. UW-MTX1.5G CL91965OOOO
Description Cat. No. (`) UW-MTX1.5Gi CL90552OOOO
Per Unit
UW-MTX3.5 CL90645OOOO
Mechanical Interlock using Bowden Cable (5 meters length)
UW-MTX3.5EC CL90644OOOO
Between 2 Incomers CL90663OOOO
UW-MTX3.5H CL90646OOOO
Between 3 Incomers CL90664OOOO * UW-MTX4.5 *
Between 2 Incomers & 1 Standby CL90665OOOO New UW-MTX3.5T #
Between 2 Incomers & 1 Buscoupler CL90666OOOO New UW-MTX3.5ET #
Mechanical Interlock using Bowden Cable (3 meters length) New UW-MTX4.5T #
New UW-MTX3.5A *
Between 2 Incomers CL90659OOOO *
Power supply module with 2 Ports CL90722OOOO
Between 3 Incomers CL90660OOOO * New 1A Power supply module CL91895OOOO
Between 2 Incomers & 1 Standby CL90661OOOO New DigiCom Module CL91896OOOO
Between 2 Incomers & 1 Buscoupler CL90662OOOO Relay Module CL90716OOOO
Mechanical Interlock using Bowden Cable (2 meters length) MODBUS Module CL90709OOOO
Profibus Module CL90295OOOO
Between 2 Incomers CL90810OOOO
Matrix Smart Card Module CL90705OOOO
Between 3 Incomers CL90811OOOO * Power Metering Module (415V) CL90649OOOO
Between 2 Incomers & 1 Standby CL90812OOOO Power Metering Module (690V) CL90685OOOO
Between 2 Incomers & 1 Buscoupler CL90813OOOO ZSI Module CL90718OOOO
Note: Common from 400A to 6300A and can be interlocked between TCS Module CL90719OOOO
Fixed / Draw-out / Mixed version EL Module CL90720OOOO
* Available on request REF Module CL90721OOOO
Simulation Kit CL90724OOOO
For Energy Management Communication Software Please contact the nearest branch office
# Integrated Release along with ACB - available as Factory-fitted option only
Presenting the pre-engineered
CNCS to OMEGA Retrofit kit
CNCS to OMEGA Retrofit kit is a
pre-engineered solution which
allows you to upgrade from the
old CNCS ACB to the advanced
OMEGA ACB - with minimal
modification. All installations
are done by trained Engineers
from the nearestAuthorised Service
Centre to ensure total reliability
and minimum shut-down time.
Specifications
› ETP grade Copper links with
Silver Plating
› CNCS to OMEGA Retrofit solution
is available from 800A to 3200A
For more details please
scan the QR code or click here
For retrofitting of any ACB to Omega ACB please contact the nearest branch office
Customer Interaction Center (CIC)
Phone no: 022-6932 7800
Web: www.LK-EA.com | e-mail: CIC@LK-EA.com Lauritz Knudsen, 15.08.2026 79PDF page 87 New Digital Offerings of Air Circuit Break
Extracted reference text; use the original PDF to check column alignment, variants and price units.
New Digital Offerings of Air Circuit Breakers
New Power Supply Module (230V AC - 24V DC 1A) MTX Release Units
› 100-265V AC Input Voltage Communication Module
› Regulated 24V DC Output Voltage
› Suitability of up to 1 Amp Loading ZSI Module
› Compact (2M) and Modular Design
› Suitable for DIN Rail & Base mounting
Temperature Module
DigiCom Module
Module Compatibility M.R.P. (`)
PS Module Details Function
Per Unit
New
PS Module Suitable for providing regulated 24V DC All MTX Release Units for Powering ON, MODBUS Module,
(CAT Code: CL91895OOOO) Power Supply ZSI Module, Temperature Module, UN-CO Module & DigiCom Module 11400
UW-PS Module Suitable for providing regulated 24V DC
Power Supply and Internal Communication All MTX Release Units and MTX Modules 29700
(CAT Code: CL90722OOOO)
Bus
New DigiCom Module
Status Monitoring & Control of up to 3 Circuit Breakers
› 3 Digital Inputs for 3 Circuit Breakers - 9 Digital Inputs Input Terminal Block
(24V DC)
› 2 Relay Outputs for 3 Circuit Breakers – 6 Relay Outputs Main Power For
Input Communication
› 24V DC Input Voltage
› Status Monitoring & Control of up to 3 Circuit Breakers through
communication over MODBUS RTU protocol with RS 485 port.
› For optimal performance, CFI and RTC micro switches should be
selected along with the ACB.
CBS1 ON/OFF Indication for Circuit Breaker 1
Input Status
TS1 Trip status Indication for Circuit Breaker 1
CB1 Indicator
Ready spring/Ready to Close Status Indication for
RS1 Indicator For
Circuit Breaker 1
System Status
Input Status CBS2 ON/OFF Indication for Circuit Breaker 2
Indicator TS2 Trip status Indication for Circuit Breaker 2 Output Status
CB2 Indicator
Ready spring/Ready to Close Status Indication for
RS2
Circuit Breaker 2
CBS3 ON/OFF Indication for Circuit Breaker 3
TS3 Trip status Indication for Circuit Breaker 3
CB3
Ready spring/Ready to Close Status Indication for
RS3
Circuit Breaker 3
Output Teminal Block
O1 Open Circuit Breaker 1 (230V AC/24V DC)
CB1
C1 Close Circuit Breaker 1
Output Status DigiCom Module Details M.R.P. (`)
O2 Open Circuit Breaker 2
Indicator CB2 Per Unit
C2 Close Circuit Breaker 2
New
O3 Open Circuit Breaker 3 DigiCom Module
CB3 (CAT Code: CL91896OOOO) 33800
C3 Close Circuit Breaker 3
Connection Architecture of DigiCom
MODBUS RS485
SmartComm/PC
DigiCom Module
Circuit Breakers / Switching Devices Lauritz Knudsen, 15.08.2026 80PDF page 88 C-POWER Air Circuit Breakers
Extracted reference text; use the original PDF to check column alignment, variants and price units.
C-POWER Air Circuit Breakers
C-POWER S1 Range of Air Circuit Breakers
› Conforms to IS/IEC 60947-2 & IEC 60947-2
› Current rating from 400A to 3200A
› Available in 50kA & 60kA breaking capacity
› Available in 3 Pole/4 Pole, Manually & Electrically operated, Fixed & Draw-out versions
› High short time withstand capacity, Icu = Ics = Icw for 1 sec for total selectivity
› High mechanical and electrical operating life
› 100% rated neutral pole
› Common height and depth across the range
› Protection through Thermal - Magnetic (DN1) & Microprocessor releases
(SR18G, SR18G+D & SR18Gi+D)
› Self diagnostic Microprocessor based Releases with on-load testing through TEST button
C-POWER S1 ACB
› Inbuilt thermal memory
› Protection Releases conform to EMI/EMC standards
› Breaker Status and Control through MODBUS protocol
C-POWER C Range of Air Circuit Breakers
› Conforms to IS/IEC 60947-2 & IEC 60947-2
› Current rating from 800A to 6300A
› Available in 50,55,60 & 95kA breaking capacity
› Available in 3 Pole/4 Pole, Manually & Electrically operated, Fixed & Draw-out versions
› High short time fault withstanding capacity, Icu = Ics = Icw for 1 sec for total selectivity
› High mechanical and electrical operating life
› 100% rated neutral pole
› Protection through Thermal - Magnetic (DN1) & Microprocessor releases
(SR18G, SR18G+D, SR18Gi+D)
› Self diagnostic Microprocessor based Releases with on-load testing through TEST button
C-POWER C ACB
› Inbuilt thermal memory
› Protection Releases conform to EMI/EMC standards
› Data communication & Power Management
› Breaker Status and Control through MODBUS protocol
C-POWER HE ACBs for Harsh Environment
› Designed to operate at peak efficiency in Sulphur-rich Harsh corrosive environments
› Range 1250A to 5000A, 415/690V ac
› Available in 3 Pole/4 Pole, Manually & Electrically operated, Fixed and Draw-out versions
› Protection through Microprocessor release
› Operates reliably in 3C4 environmental conditions containing SO2 and H2S
Please contact the nearest branch office for Details & product Selection
C-POWER HE Range
Breaking Capacities Offered:
Icu = Ics = Icw for 1 sec
630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6300A
CN-CS : E / G 50kA 50kA 50kA 50kA 50kA 50kA
Frame-1
CN-CS : S1 50kA 50kA 50kA 50kA 50kA 50kA 60kA 60kA
Frame-1 Frame-2
CN-CS : C 50kA 50kA 50kA 50kA 55kA 60kA 95kA 95kA
CN-CS : H 65kA 65kA 65kA 65kA 75kA 75kA
CN-CS : H2 75kA 75kA
CN-CS : H / H1 100kA 100kA
CN-CS : HE 50kA 60kA 75kA 95kA
Frame-1 Frame-2 Frame-3 Frame-4
For technical & dimension details please refer product catalogue. 400A ACB also available on request.
Lauritz Knudsen, 15.08.2026 81PDF page 89 C-POWER Air Circuit Breakers [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
C-POWER Air Circuit Breakers [8536]
C-POWER S1 3 & 4 Pole Draw-out ACBs
Microprocessor Based SR18G Thermal-Magnetic DN1
Breaking
Capacity 3 Pole 4 Pole 3 Pole 4 Pole
Rating Version
Icu=Ics=Icw
(1 sec) M.R.P. (`) M.R.P. (`) Cat. No. M.R.P. (`) Cat. No. M.R.P. (`)
Cat. No. Cat. No. Per Unit Per Unit
Per Unit Per Unit
MDO SL96041 307200 SL96061 385400 SL95331 304000 SL95351 382200
630A 50kA
EDO SL96051 378500 SL96071 456700 SL95341 375300 SL95361 453500
MDO SL96042 307200 SL96062 385400 SL95332 304000 SL95352 382200
800A 50kA
EDO SL96052 378500 SL96072 456700 SL95342 375300 SL95362 453500
MDO SL96043 319400 SL96063 403600 SL95333 316200 SL95353 400400
1000A 50kA
EDO SL96053 390700 SL96073 474900 SL95343 387500 SL95363 471700
MDO SL96044 352400 SL96064 444500 SL95334 349200 SL95354 441300
1250A 50kA
EDO SL96054 423700 SL96074 515800 SL95344 420500 SL95364 512600
MDO SL96045 401700 SL96065 494100 SL95335 398500 SL95355 490900
1600A 50kA
EDO SL96055 473000 SL96075 565400 SL95345 469800 SL95365 562200
MDO SL96046 471900 SL96066 579600 SL95336 468700 SL95356 576400
2000A 50kA
EDO SL96056 543200 SL96076 650900 SL95346 540000 SL95366 647700
MDO SL96047 583300 SL96067 703100 SL95337 580100 SL95357 699900
2500A 60kA
EDO SL96057 654600 SL96077 774400 SL95347 651400 SL95367 771200
Note : Add a Suffix "OOOO" for all the above mentioned cat. nos.
C-POWER S1 3 & 4 Pole Fixed ACBs
Microprocessor Based SR18G Thermal-Magnetic DN1
Breaking
Capacity 3 Pole 4 Pole 3 Pole 4 Pole
Rating Version
Icu=Ics=Icw M.R.P. (`) M.R.P. (`)
M.R.P. (`) Cat. No. M.R.P. (`) Cat. No. Cat. No.
(1 sec) Cat. No.
Per Unit Per Unit Per Unit Per Unit
MF SL95561 167500 SL95581 213600 SL95481 164300 SL95501 210400
630A 50kA
EF SL95571 238800 SL95591 284900 SL95491 235600 SL95511 281700
MF SL95562 167500 SL95582 213600 SL95482 164300 SL95502 210400
800A 50kA
EF SL95572 238800 SL95592 284900 SL95492 235600 SL95512 281700
MF SL95563 182900 SL95583 230900 SL95483 179700 SL95503 227700
1000A 50kA
EF SL95573 254200 SL95593 302200 SL95493 251000 SL95513 299000
MF SL95564 210800 SL95584 263400 SL95484 207600 SL95504 260200
1250A 50kA
EF SL95574 282100 SL95594 334700 SL95494 278900 SL95514 331500
MF SL95565 233600 SL95585 300500 SL95485 230400 SL95505 297300
1600A 50kA
EF SL95575 304900 SL95595 371800 SL95495 301700 SL95515 368600
Note Add a Suffix "OOOO" for all the above mentioned cat. nos.
M.R.P. changes for product customization w.r.t. SR18G ACB M.R.P. M.R.P. (`) Per Unit
Bus - Coupler (w/o protection) Reduce 8400
Microprocessor based SR18G+D (LSING + Current Metering) Add 22600
Microprocessor based SR18Gi+D (LSING + Current metering + ZSI) Add 29900
C-POWER S1 Draw-Out ACBs will have inbuilt - 2NO+2NC Aux contact for MDO & 6NO+6NC Aux contact for EDO breakers, Safety shutter assembly,
Racking handle, Door sealing frame, Push-button cover & Rating error preventor.
Electrical version includes 240V AC Shunt trip coil, Closing coil and Motor for electrical charging.
C-POWER S1 Fixed ACBs will have inbuilt - 2NO+2NC Aux contact for MF & 6NO+6NC Aux contact for EF breakers, Door sealing frame & Push-button cover.
Electrical version includes 240V AC Shunt trip coil, Closing coil and Motor for electrical charging.
Note: 1 NO Aux contact in manual version & 2NO+2NC in electrical version breakers will be pre-wired with accessories mounted in breaker.
In electrically operated breaker with DN1 release, either earth fault or undervoltage protection can be used.
CN-CS-E Range 3 Pole Manual Fixed
Breaking Thermal-Magnetic Release Type DN1
Capacity M.R.P.
Rating Version
Icu=Ics=Icw Cat. No. (`)
(1 sec)
Per Unit
400A 50kA 3P MF SL95721OOOO 108900
630A 50kA 3P MF SL95722OOOO 109900
800A 50kA 3P MF SL95723OOOO 116400
1000A 50kA 3P MF SL95724OOOO 119300
1250A 50kA 3P MF SL95725OOOO 149300
1600A 50kA 3P MF SL95726OOOO 157200
2000A 50kA 3P MF SL93297OOOO 180500
Lauritz Knudsen, 15.08.2026 82PDF page 90 C-POWER Air Circuit Breakers [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
C-POWER Air Circuit Breakers [8536]
C-POWER 3 & 4 Pole Draw-out ACBs
Microprocessor Based SR18G Thermal-Magnetic DN1
Breaking
Capacity 3 Pole 4 Pole 3 Pole 4 Pole
Rating Version Type
Icu=Ics=Icw M.R.P. (`) M.R.P. (`) M.R.P. (`) M.R.P. (`)
(1 sec) Cat. No. Cat. No. Cat. No. Cat. No.
Per Unit Per Unit Per Unit Per Unit
MDO H SL95311 543900 # 704700 # 540700 # 701500
800A 65kA
EDO H SL95321 615200 # 776000 # 612000 # 772800
MDO H SL95312 553900 # 749000 # 550700 # 745800
1000A 65kA
EDO H SL95322 625200 # 820300 # 622000 # 817100
MDO H SL95313 605600 # 803300 # 602400 # 800100
1250A 65kA
EDO H SL95323 676900 # 874600 # 673700 # 871400
MDO H SL95314 681600 # 884100 # 678400 # 880900
1600A 65kA
EDO H SL95324 752900 # 955400 # 749700 # 952200
MDO H SL95315 753300 # 903900 # 750100 # 900700
2000A 75kA
EDO H SL95325 824600 # 975200 # 821400 # 972000
MDO H SL95316 784100 # 954600 # 780900 # 951400
2500A 75kA
EDO H SL95326 855400 # 1025900 # 852200 # 1022700
MDO H2 SL94822 826200 SL94826 1014100 # * # *
3200A 75kA
EDO H2 SL94824 897500 SL94828 1085400 # * # *
MDO H2 SL94823 939000 SL94827 1173500 # * # *
4000A 75kA
EDO H2 SL94825 1010300 SL94829 1244800 # * # *
5000A 95kA MDO/EDO C # * # # #
* * *
6300A 95kA MDO/EDO C # # # #
* * * *
Note: For higher breaking capacities & 690V AC application please contact the nearest branch office
Add a Suffix "OOOO" for all the above mentioned cat. nos.
C-POWER 3 & 4 Pole Manual Fixed ACBs
Microprocessor Based SR18G Thermal-Magnetic DN1
Breaking
Capacity 3 Pole 4 Pole 3 Pole 4 Pole
Rating Version Type
Icu=Ics=Icw M.R.P. (`) M.R.P. (`) M.R.P. (`) M.R.P. (`)
(1 sec) Cat. No. Cat. No. Cat. No. Cat. No.
Per Unit Per Unit Per Unit Per Unit
800A 50kA
1000A 50kA
1250A 50kA * *
MF C
1600A 50kA
2000A 55kA SL97635 355500 # 461200 SL93005 352300 # 458000
2500A 60kA SL97636 391800 # 528000 SL93006 388600 # 524800
Note: For higher breaking capacities & 690V AC application please contact the nearest branch office
Add a Suffix "OOOO" for all the above mentioned cat. nos.
M.R.P. changes for product customization w.r.t. SR18G M.R.P. M.R.P. (`)
Per Unit
Bus-Coupler (w/o protection) Reduce 8400
Microprocessor based SR18G+D (LSING + Current Metering) Add 22600
Microprocessor based SR18Gi+D (LSING + Current metering + ZSI) Add 29900
C-POWER Draw-Out ACBs will have inbuilt - 6NO+6NC Aux contact, Safety shutter assembly, Racking handle, Door sealing frame, Push-button cover & Rating
Error preventor. Option of horizontal & vertical termination upto 4000A also available. Operation counter for 4000A & above.
EDO version includes 240V AC Shunt trip coil, Closing coil and Motor for electrical charging.
C-POWER Fixed ACBs will have inbuilt - 6NO+6NC Aux contact, Door sealing frame & Push-button cover. Operation counter for 4000A & above.
Note: 1 NO Aux contact in manual version & 2NO+2NC in electrical version breakers will be pre-wired with accessories mounted in breaker.
In electrically operated breaker with DN1 release, either earth fault or undervoltage protection can be used.
Note: Electrical Fixed type breakers are available on request.
# Available on "Made to order" basis. * Available on request
Lauritz Knudsen, 15.08.2026 83PDF page 91 Accessories of C-POWER Air Circuit Breakers
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Accessories of C-POWER Air Circuit Breakers
Accessories (Common for C-POWER Family)
LTPB LIP Shunt Release UV Release
M.R.P. M.R.P.
Description Cat. No. (`) Description Cat. No. (`)
Per Unit Per Unit
Lockable Trip Push Button (LTPB) [8301] Shunt Release (SR) [8538]
Type AA SL93148OOOA 8260 Type EA : 24/48V DC SL92718O4OO 5300
Type BB SL93148OOOB 8260 Type EA : 110V DC SL92718O1OO 5300
Type CC SL93148OOOC 8260 Type EA : 220V DC SL92718O2OO 5300
Type DD SL93148OOOD 8260 Type EA1 : 110V AC SL92718OAOO 5300
Lockable Trip Push Button kit (3 I/C & 2 B/C) SL91936OOOO 41400 Type EA1 : 240V AC SL92718OBOO 5300
Locking of ACB in Isolated position (LIP) [8301] Type EA1 : 415V AC SL92718ODOO 5300
Type A SL93146OOOA 8260 Under Voltage Release (UVR) [8538]
Type B SL93146OOOB 8260 Type MV : 24V DC ST36877OOOO 9310
Type C SL93146OOOC 8260 Type MV : 240V AC SL92720BOOO 9310
Type D SL93146OOOD 8260 Type MV : 415V AC SL92720DOOO 9310
Locking of ACB in Any position (LAP) [8301] Earth Fault Release ( for DN1) [8538]
Type A SL93147OOOA 8260 Type EF1 (10%, 20% In ) SL91340OOOO 8230
Type B SL93147OOOB 8260 Type EF2 (30%, 40%, 50% In) SL91341OOOO 8230
Type C SL93147OOOC 8260 Remote Fault Indication [8538]
Type D SL93147OOOD 8260 AN1 Remote Annunciation Module for
SL94654OOOO 20000
Racking Interlock [8301] SR18G/SR18G+D/SR18Gi+D : 240V AC
Type AA SL93149OOOA 11300 Microswitches for Indication [8536]
Type BB SL93149OOOB 11300 Microswitch for Voltmetric Releases (2) each SL92703OOOO 5110
Type CC SL93149OOOC 11300 Microswitch for Common Indication of O/L &
SL92704OOOO 5110
Type DD SL93149OOOD 11300 S/C (3) each
Padlock [8301] Microswitch for Separate Indication of O/L &
SL92705OOOO 8540
Racking Padlock Assembly CL90025OOOO 3840 S/C (3) each (for DN1 release)
Other Accessories [8538] Service Position Microswitch - Right (2) SL93142OOOO 3450
Door Interlock SL93150OOOO 6050 Service Position Microswitch - Left (2) SL93143OOOO 3450
Mechanical Operation Counter* XM80837OOOO 6000 Test or Isolated Position Microswitch - Right (2) SL93144OOOO 3450
Mounting Kit for Front Mounted Counter SL95882OOOO 2120 Test or Isolated Position Microswitch - Left (2) SL93145OOOO 3450
Spring Charge Indication Microswitch SL96000OOOO 4800
Note:
* For mounting the Operation counter, mounting kit “SL95882OOOO” needs to be a. The Numerical in brackets, against various accessories indicate the SICs
ordered separately. Operation Counter inbuilt for rating 4000A to 6300A. required for wiring purpose in Draw-Out breakers
b. Shunt release requires one set of auxiliary contacts
c. Maximum 24 SICs can be fitted on an ACB. In Electrical ACBs 5 SICs are
prewired for control circuit purpose
Vertical Terminal Adaptor
M.R.P. Std. Features
Description & Rating Cat. No. (`) Pkg. › Remote Status & Control of ACB
Per Unit (Nos.)
› Communicates on MODBUS Protocol
Vertical Terminal Adaptors for Draw out C-POWER ACB [8538] › Inbuilt RS485 Port
400-1250 S1/800-1000 C SL93281OOOO 10300 1
1600-2000 S1/1250-1600 C/800-1600 H SL93282OOOO 12500 1 M.R.P. Std.
Description Cat. No. (`) Pkg.
2000 C SL93284OOOO 18500 1 Per Unit (Nos.)
2000 H/2500 C/H SL93285OOOO 19300 1 UN-CO module for Breaker control CL90852OOOO** 24300 1
2500 S1 SL93289OOOO 19300 1 **Available till stock last
3200 S1 SL93286OOOO 23800 1
3200H2/H1, 4000H2/H SL93288OOOO 57500 1
Lauritz Knudsen, 15.08.2026 84PDF page 92 Spares of C-POWER Air Circuit Breakers
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Spares of C-POWER Air Circuit Breakers
Protection Releases M.R.P.
Description Cat. No. (`)
Per Unit
Protection Releases [8538]
Microprocessor based type SR18Gi+D SL94813OOOO 98400
Microprocessor based type SR18G+D SL94812OOOO 91100
Microprocessor based type SR18G SL96030OOOO 68500
Thermal-Magnetic Release type DN1 SL93152OOOO 65300
Universal Test Kit CL90462OOOO 140200
SR18G SR18G+D Universal Test Kit
Compatible with following Lauritz Knudsen Protection Releases
› SR protection releases of C-Power ACB family
› UNRS protection releases of U-Power ACB family
› MTX and RC releases of D-Sine MCCB family
Retrofit kit solutions are available
For further details please contact the nearest branch office
M.R.P. Std.
Description Cat. No. (`) Pkg.
Per Unit (Nos.)
CTs for SR18G / SR18G+D / SR18Gi+D [8504]
400 S1 Fix & Draw-out SL01523OOOO 11400 1
SR18Gi+D 630 S1 Fix & Draw-out ST37495OOOO 11400 1
800 C/H/S1 Fix & Draw-out SL01857OOOO 11400 1
1000 C/H/S1 Fix & Draw-out SL01858OOOO 11400 1
1250 C/H/S1 Fix & Draw-out SL90571OOOO 13900 1
1600 C/H/S1 Fix & Draw-out SL90572OOOO 13900 1
2000 C/H Fix & Draw-out SL90565OOOO 15200 1
2000 S1 Draw-out SL93210OOOO 15200 1
2500 C/H Fix & Draw-out
SL90566OOOO 15200 1
2500 S1 Draw-out
3200 H2/H1 Draw-out SL01740OOOO 17600 1
4000 H2/H Draw-out SL01739OOOO 20900 1
For External Neutral C.T.s please use the above Cat. No.
CT
Lauritz Knudsen Electrical & Automations HE range of Air Circuit Breakers (ACBs) and Switch-Disconnector-Fuse (S-D-F) are designed to
ensure that they operate at peak efficiency for their entire lifespan in harsh, Sulphur-rich Harsh corrosive environments.
For more details please Customer Interaction Center (CIC)
scan the QR code or click here Phone no: 022-6932 7800
Web: www.LK-EA.com | e-mail: CIC@LK-EA.com
Lauritz Knudsen, 15.08.2026 85PDF page 93 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 94 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 95 Power Quality Solutions
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Power Quality Solutions
Power Factor Correction Capacitors [8532]
Heavy Duty HD Plus Super
Standard Duty Heavy Duty APP LTXL Ultra Heavy Duty
Gas Filled
Parameters
Cylindrical Box Cylindrical Box Cylindrical Cylindrical Box Cylindrical Box
Over current
withstand 1.5 x In 1.5 x In 1.8 x In 1.8 x In 2.0 x In 2.5 x In 2.5 x In 3 x In 3 x In
capability
Operating
0.45 W/kVAr 0.45 W/kVAr 0.5 W/kVAr 0.5 W/kVAr 0.45 W/kVAr 0.45 W/kVAr 0.5 W/kVAr 0.45 W/kVAr 0.5 W/kVAr
losses
Peak Inrush
current
withstand 200 x In 200 x In 250 x In 300 x In 300 x In 350 x In 300 x In 500 x In 500 x In
capability
Number of
switching
operations 5000 5000 7500 8000 10000 15000 10000 18000 20000
per year
Max. 55OC 55OC 55OC 55OC 55OC 65OC 55OC 65OC 70OC
Temperature
Operating life 100000 hrs. 100000 hrs. 130000 hrs. 150000 hrs. 180000 hrs. 200000 hrs. 200000 hrs. 300000 hrs. 300000 hrs.
Standard Duty Capacitors
Features
› Finger proof terminal in Cyl capacitor
› 150% continuous current carrying capacity
› Self-Healing property
› Soft resin as coolant
› Inbuilt Over Pressure Disconnector (OPD)
M.R.P.
Type
kVAr
Rating
Voltage
(V)
(`) Heavy Duty Capacitors
per kVAr
Features
1 to 25 440 299
Cylindrical › 180% continuous current carrying capacity
1 to 6 kVAr - Series : LTCCF 1.2 to 27.7 480 299
7.5 to 33.1 kVAr - Series : LTCCD › Finger proof terminal in Cyl capacitor
1.3 to 33.1 525 299 › Self-Healing property
Box
1 to 50 440 383 › Soft resin as coolant
1 to 6 kVAr - Series : LTBCF 11.1 to 27.7 480 383 › Inbuilt over pressure disconnector (OPD)
7.5 to 33.1 kVAr - Series : LTBCD › Low losses
13.2 to 33.1 525 383
M.R.P.
kVAr Voltage
Type (`)
Rating (V)
per kVAr
HD Plus Gas Filled Capacitor 1 to 4 572
Features 5 to 15 440 V 526
› High inrush current carrying capacity 300 x In 20 to 30 512
› Inert gas as coolent (Non-flammable) Cylindrical Series:
1.2 to 4.4* 572
› Finger proof terminal in Cyl capacitor LTCCH
› Self-Healing property 5.5 to 16.6 480 V 526
› Inbuilt Over Pressure Disconnector (OPD) 22.1 to 27.7 512
› Long life 1.3 to 5.3* 572
6.6 to 16.6 525 V 526
M.R.P.
kVAr Voltage 20 to 33.1 512
Type (`)
Rating (V)
per kVAr
1 to 4 733
7.5 to 15 623 440 V
440 5 to 15 634
20 & 25 579
20 to 50 621
7.5 to 15 623
480 Box Series:
Cylindrical Series: LTCCN 20 to 30 579 LTBCH 5.5 to 15 634
480 V
7.5 to 15 623 20 to 27.7 621
525
20 to 33.1 579 6.6 to 15 634
525 V
20 to 33.1 621
* Now smaller rating also available in Heavy Duty Cylindrical
Lauritz Knudsen, 15.08.2026 88PDF page 96 Power Quality Solutions
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Power Quality Solutions
Super Heavy Duty APP Capacitors
Capacitors Features
Features › High over current withstand capacity 2.5 x In
› High over current withstand capacity 2.5 x In
› High Inrush current withstand capacity 300 x In
› High Inrush current withstand capacity 350 x In
› Glazed ceramic bushing
› Finger proof Sigut terminal in Cyl capacitor
› Tinned Copper studs
M.R.P.
Type
kVAr Voltage › Corrosion proof stainless steel Earthing pad
Rating (V) (`)
per kVAr
M.R.P.
kVAr Voltage
3 to 5 860 Type (`)
Rating (V)
per kVAr
7.5 to 15 703
440 V 5 to 15 1079
20 & 25 665 440 V
20 to 50 1044
1.2 to 5.5 860
Cylindrical Series: Box 5.5 to 13.8 1079
11.1 & 15 480 V 703 480 V
LTCCR Series: LTBCP 16.6 to 55.3 1044
20 to 27.7 665
6.6 & 13.2 1079
1.3 to 5 860 525 V
16.6 to 66.2 1044
6.6 to 15 525 V 703
20 to 33.3 665
LTXL - Ultra Heavy Duty Capacitors
Features
› High over current withstand capacity 3 x In Ordering Information for Capacitors
› High Inrush current withstand capacity 500 x In C - Cylindrical, B - Box
› Glazed ceramic bushing (In box type capacitor)
› Lower thermal impedance
› Designed to operate at temperature up to 70oC Duty: D/F – Standard**
› Corrosion proof stainless steel Earthing pad H - Heavy
N - Gas Filled
kVAr Voltage M.R.P. R - Super Heavy
Type (`)
Rating (V) P - APP
per kVAr
U - Ultra Heavy
5 to 15 1660
440V
20 & 25 1633
Sample ratings
Cylindrical 7.5 to 15 1660
Series : LTCCU 480V
20 1633 01 - 1 kVAr
kVAr
7.5 to 15 1660 07 - 7.5 kVAr
525V Rating
20 1633
10 - 10 kVAr
5 to 15 1848
440V 12 - 12.5 kVAr
20 to 50 1812
7.5 to 15 1848
Voltages:B - 440V, C - 480V, M- 525V
Box
Series: LTBCU 480V
20 to 30 1812 ** F - 1 to 6 kVAr. D - 7.5 kVAr & above
7.5 to 15 1848
20 to 33.1
525V
1812
L T C 3 2 Catalogue Number
kVAr ratings
Capacitor
Series 440 V 480 V 525 V
LTCCF 1, 2, 3, 4, 5, 6 1.2, 2.2, 3.3, 4.4, 5.5 1.3, 2.6, 3.9, 5.3, 6.6
LTBCF 1, 2, 3, 4, 5, 6 - -
LTCCD/LTBCD 7.5, 8.33, 10, 12.5, 15, 20, 25, 30* 11.1, 13.8, 16.6, 22.1, 27.7 13.2, 16.6, 20, 26.5, 30, 33.1
LTCCH 1, 2, 3, 4, 5, 7.5, 10, 12.5, 15, 20, 25, 30 1.2, 2.2, 3.3, 4.4, 5.5, 11.1, 13.8, 16.6, 22.1, 27.7 1.3, 2.6, 3.9, 5.3, 6.6, 13.2, 16.6, 20, 26.5, 30, 33.1
LTBCH 1, 2, 3, 4, 5, 7.5, 8.33, 10, 12.5, 15, 20, 25, 30, 50 5.5, 11.1, 15, 20, 25, 27.7 6.6, 13.2, 15, 20, 25, 30, 33.1
LTCCN 7.5, 8.33, 10, 12.5, 15, 20, 25 7.5, 12.5, 15, 20, 25, 30 7.5, 12.5, 15, 20, 25, 30, 33.1
LTCCR 3, 4, 5, 7.5, 8.33, 10, 12.5, 15, 20, 25 1.2, 2.2, 3.3, 4.4, 5.5, 11.1, 15, 20, 25, 27.7 1.3, 2.6, 3.9, 5, 6.6, 13.2, 15, 20, 25, 30, 33.3
LTBCP 5, 7.5, 10, 12.5, 15, 20, 25, 50 5.5, 11.1, 13.8, 16.6, 22.1, 27.7, 55.3 6.6, 13.2, 16.6, 20, 26.5, 30, 33.1, 66.2
LTCCU 5, 7.5, 8.33, 10, 12.5, 15, 20, 25 7.5, 10, 12.5, 15, 20 7.5, 10, 12.5, 15, 20
LTBCU 5, 7.5, 8.33, 10, 12.5, 15, 20, 25, 30, 50 7.5, 10, 12.5, 15, 20, 25, 30 7.5, 12.5, 15, 20, 25, 30, 33.1
*Only LTBCD is available at 30 kVAr
Lauritz Knudsen, 15.08.2026 89PDF page 97 Power Quality Solutions
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Power Quality Solutions
Detuned Reactors, 440 V, 50 Hz [8504]
Features
› Copper & Aluminium wound reactors
› H-class insulation
› Lower operating losses
› 180% linearity*
› Thermal cut off
› High Quality Factor
7% Copper Reactor 7% Aluminium Reactor 14% Copper Reactor 14% Aluminium Reactor
kVAr
Rating M.R.P. (`) M.R.P. (`) M.R.P. (`) M.R.P. (`)
Cat. No. Cat. No. Cat. No. Cat. No.
Per Unit Per Unit Per Unit Per Unit
1 LTFR0701B2 15821 LTAL0701B2 9733 LTFR1401B2 30755 LTAL1401B2 16062
2 LTFR0702B2 17277 LTAL0702B2 10616 LTFR1402B2 33528 LTAL1402B2 17493
3 LTFR0703B2 19585 LTAL0703B2 12024 LTFR1403B2 38025 LTAL1403B2 19821
4 LTFR0704B2 20817 LTAL0704B2 12783 LTFR1404B2 40427 LTAL1404B2 21085
5 LTFR0705B2 23373 LTAL0705B2 13822 LTFR1405B2 43710 LTAL1405B2 24124
10 LTFR0710B2 31927 LTAL0710B2 19617 LTFR1410B2 61958 LTAL1410B2 34314
12.5 LTFR0712B2 36028 LTAL0712B2 21936 LTFR1412B2 67971 LTAL1412B2 39308
15 LTFR0715B2 41851 LTAL0715B2 26320 LTFR1415B2 74783 LTAL1415B2 46966
20 LTFR0720B2 46350 LTAL0720B2 29294 LTFR1420B2 86616 LTAL1420B2 53387
25 LTFR0725B2 47256 LTAL0725B2 29857 LTFR1425B2 95122 LTAL1425B2 54818
50 LTFR0750B2 79216 LTAL0750B2 46489 LTFR1450B2 153681 LTAL1450B2 77441
75 LTFR0775B2 117745 LTAL0775B2 68475 LTFR1475B2 222318 LTAL1475B2 115138
100 LTFR0700B2 153209 LTAL0700B2 94093 LTFR1400B2 297019 LTAL1400B2 155251
* Prices of 200% linearity reactors are available on request.
For industries with High Voltage Harmonics, special solutions are available on request. Contact your nearest sales office for the customised solutions.
Selection of capacitors for detuned harmonic filter application
Step Size &
With 7% detuned reactor With 14% detuned reactor
440 V
Reactor rating 480 V Capacitor 525 V Capacitor 525 V Capacitor
(kVAr) Capacitor series (kVAr) Capacitor series (kVAr)
(kVAr)
1 LTCCF, LTCCH, LTCCR 1.2 1.3 LTCCF, LTCCH, LTCCR 1.3
2 LTCCF, LTCCH, LTCCR 2.2 2.6 LTCCF, LTCCH, LTCCR 2.6
3 LTCCF, LTCCH, LTCCR 3.3 3.9 LTCCF, LTCCH, LTCCR 3.9
LTCCF, LTCCH 5.3 LTCCF, LTCCH 5.3
4 4.4
LTCCR 5 LTCCR 5
LTCCF, LTCCH, LTCCR, LTBCH, LTBCP 5.5 6.6 LTCCF, LTCCH, LTCCR, LTBCH, LTBCP 6.6
5
LTCCN, LTCCU, LTBCU 7.5 7.5 LTCCN, LTCCU, LTBCU 7.5
LTCCD, LTCCH, LTCCR, LTBCD, LTBCH, LTBCP 11.1 13.2 LTCCD, LTCCH, LTCCR, LTBCD, LTBCH, LTBCP 13.2
10
LTCCN, LTCCU, LTBCU 12.5 12.5 LTCCN, LTCCU, LTBCU 12.5
LTCCN, LTCCR, LTCCU, LTBCH, LTBCU 15 15 LTCCN, LTCCR, LTCCU, LTBCH, LTBCU 15
12.5
LTCCD, LTCCH, LTBCD, LTBCP 13.8 16.6 LTCCD, LTCCH, LTBCD, LTBCP 16.6
LTCCN, LTCCR, LTCCU, LTBCH, LTBCU 20 LTCCD, LTCCN, LTCCH, LTCCR, LTCCU,
15 20 20
LTCCD, LTCCH, LTBCD, LTBCP 16.6 LTBCD, LTBCH, LTBCP, LTBCU
LTCCN, LTCCR, LTBCH, LTBCU 25 25 LTCCN, LTCCR, LTBCH, LTBCU 25
20 LTCCD, LTCCH, LTBCD, LTBCP 22.1 26.5 LTCCD, LTCCH, LTBCD, LTBCP 26.5
LTCCU 7.5 + 15 2 x 12.5 LTCCU 2x12.5
LTCCD, LTCCH, LTCCR, LTBCD, LTBCH, LTBCP 27.7 LTCCD, LTCCN, LTCCH, LTCCR,
33.1 30
25 LTBCU, LTCCN 30 LTBCD, LTBCH, LTBCP, LTBCU
LTCCU 12.5 + 15 15 + 20 LTCCU (10+20)
LTCCD, LTCCH, LTCCR, LTBCD, LTBCH 2 x 27.7 LTCCD, LTCCN, LTCCH, LTCCR,
2 x 33.1 2 x 30
LTBCU, LTCCN 2 x 30 LTBCD, LTBCH, LTBCP, LTBCU
50
LTCCU 2 x (12.5 + 15) 2 x (15 + 20)
LTCCU 3 x 20
LTBCP 55.3 66.2
LTCCD, LTCCH, LTCCR, LTBCD, LTBCH 3 x 27.7 LTCCD, LTCCN, LTCCH, LTCCR,
3 x 33.1 3 x 30
LTBCU, LTCCN 3 x 30 LTBCD, LTBCH, LTBCP, LTBCU
75
LTCCU 3 x (12.5 + 15) 3 x (15 + 20)
LTCCU (4 x 20) + 10
LTBCP 27.7 + 55.3 33.1 + 66.2
LTCCD, LTCCH, LTCCR, LTBCD, LTBCH, LTBCP 4 x 27.7 LTCCD, LTCCN, LTCCH, LTCCR,
4 x 33.1 4 x 30
LTBCU, LTCCN 4 x 30 LTBCD, LTBCH, LTBCP, LTBCU
100
LTCCU 4 x (12.5 + 15) 4 x (15 + 20)
LTCCU 6 x 20
LTBCP 2 x 55.3 2 x 66.2
Lauritz Knudsen, 15.08.2026 90PDF page 98 Power Quality Solutions Thyristor Switchi
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Power Quality Solutions Thyristor Switching Module, 440V 50Hz [8538]
Capacitor Duty Contactors - Type MO C [8536]
Features
Features › High Peak Inverse Voltage (PIV) - 2.2 kV
› Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 › Inbuilt control supply voltage
› Delatching type early make contacts › Auto thermal cut off
› Separate termination for damping resistors › LEDs for various status/fault indications
› Encapsulated damping resistor assembly › Ambient Temperature -10° C to 55° C
› Common coil for 50 & 60Hz application › No moving parts
› Low pick-up VA consumption › On-site self test logic
› RoHS compliant › Low operating losses
› 2 Nos Aux Contact outputs for fault and status
kVAr Rating Built-in Std.
M.R.P. (`)
Size @ 440V, Type Auxiliary Cat. No. Pkg.
Per Unit
3Ph, 50Hz Contacts (Nos.)
kVAr Rating M.R.P. (`)
3 MO C3 1NO CS96146 3480 1 Cat. No.
Per Unit
5 MO C5 1NO CS96127 3700 1
10 CS92049OOOO 33245
8.5 MO C8.5 1NO CS96320 4800 1
25 CS92050OOOO 47424
10 MO C10 1NO CS96156 4910 1
50 CS92051OOOO 54317
Fr 1 12.5 MO C12.5 1NO CS96321 5180 1
Note (TSM): Above prices include Quick Discharge Resistors (QDR)
15 MO C15 1NO CS90019 6980 1
20 MO C20 1NO CS90021 7770 1
25 MO C25 1NO CS96322 8370 1 Note (MOC):
30 MO C30$ 1NO CS96148 13330 1 1) For ordering add-on aux. contact block, please refer page No. 8
40 MO C40 1NO CS96147 22120 1 2) For ordering suffix, please refer page No.10
3) For ordering spare coils, please refer page No. 11
Fr 2 50 MO C50 1NO CS96324 24830 1
4) Standard coil voltage : 240V, 50/60 Hz
60 MO C60$ 1NO CS96149 25820 1 5) For ordering MO C surge suppressor, please refer page No. 9
75 MO C75 1NO CS96150 30870 1
33220 If using 16 sq mm cable use of spreader link kit is mandatory
Fr 3 85 MO C85 1NO CS96157 1
For ordering spreader link kit, Please refer page No.9
100 MO C100$ 1NO CS96158 33870 1 $ Spreader link along with phase barrier included in packing
Lauritz Knudsen, 15.08.2026 91PDF page 99 APFC Controller [8538]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
APFC Controller [8538]
etaSMART and etaULTRA Controllers are compatible for Sites with or without a Solar plant.
Site without Solar Plant Site with Solar Plant
2 Quadrant Operation 4 Quadrant Operation
of APFC Controller of APFC Controller
CT CT
Load APFC Panel Load Solar Plant APFC Panel
Enable 4 Quadrant setting in etaSMART and etaULTRA for site with Solar Plant.
Cascading (Master - Slave configuration)
for APFC panel with more than 16 steps
etaULTRA - APFC Controller - 3 CT inputs
Features
+
› 3 Phase Current and Voltage measurement
› PF display - 3 Digit after decimal
› Individual harmonics measurement up to 31st order
› Dual PF setting for Mains - DG application
› Communication through Inbuilt MODBUS RS-485 Protocol
4 Quadrant Operation suitable for
› Suitable for LT as well as HT side sensing
Solar Powered installations
No. of steps No. of steps
(For Contactor (For Thyristor Voltage Input M.R.P. (`)
Model Name Cat No. Size
switching) switching) Per Unit
etaULTRA 8R 8 0 CS91050OOOO 31900
etaULTRA 16R 16 0 CS91051OOOO 42790
110 / 415 V 144 x 144
etaULTRA 14T+2R 2 14 CS91053OOOO 44740
etaULTRA 8T+8R 8 8 CS91054OOOO 44740
Last Two Contacts can be programmed for Capacitor Switching / Alarm Function / Fan Control
etaSMART - APFC Controller - 1 CT input
Features
› Simple and Smart Controller
› Auto programming function available
› CT secondary - 1 / 5 Amp site selectable
› Measurement of Total harmonics distortion of 4 Quadrant Operation suitable for
current and voltage up to 13th order harmonics Solar Powered installations
etaSMART T - APFC Controller for etaSMART R - APFC controller for
Thyristor Switching with 1 CT input Contactor switching with 1 CT input
No. of steps M.R.P. No. of steps M.R.P.
Single Voltage Single Voltage
(for Thyristor Size Cat. No. (`) (For Contactor Size Cat. No. (`)
CT input Input CT input Input
switching) Per Unit Switching) Per Unit
8 144 x 144 CS91614OOOO 26800 4 96 x 96 CS90884OOOO 12760
12 144 x 144 CS91615OOOO 1/ 5 Amp 415 V 33350 6 96 x 96 CS90885OOOO 14520
15 144 x 144 CS91616OOOO 38990 8 96 x 96 CS90902OOOO 17110
1/ 5 Amp 415 V
One separate relay contact is available for Alarm 12 144 x 144 CS90903OOOO 28290
14 144 x 144 CS90904OOOO 34960
16 144 x 144 CS90905OOOO 38070
Last Two Contacts can be Programmed for Capacitor Switching /
Alarm Function / Fan Control
Lauritz Knudsen, 15.08.2026 92PDF page 100 ASVG Features
Extracted reference text; use the original PDF to check column alignment, variants and price units.
ASVG Features
› Dynamic Stepless PF correction, Load balancing &
Harmonic Mitigation
› Suitable for DPF & TPF improvement
› Harmonic Mitigation up to 15th Order
› Fast response time of 50 µsec
› Scalable architecture for future expansion
› Lower thermal losses
› Communicable –Inbuilt MODBUS RS485 Protocol
› Wall mount/ Rack Mount Modules 3P3W ASVG (415 V,-25%+15%) 3P4W ASVG (415 V,-25%+10%)
kVAr
› True Hybrid Solution Compatibility Rating
* *
30 ASVG0030H3WD2 ASVG0030H4WD2
* *
Hybrid controller 50 ASVG0050H3WD2 ASVG0050H4WD2
* *
100 ASVG0100H3WD2 ASVG0100H4WD2
› Intuitive Touchscreen display
150 ASVG0150H3WD2* ASVG0150H4WD2*
› Easy installation & programming
30 ASVG0030N3RD2 ASVG0030N4RD2
› 18 Ports to connect Capacitor banks (Thyristor & Cap.
duty Contactor Switching) 50 ASVG0050N3RD2 ASVG0050N4RD2
› Alarm and Event Management 100 ASVG0100N3RD2 ASVG0100N4RD2
› Bar Chart Visualization 150 ASVG0150N3RD2 ASVG0150N4RD2
Hybrid Controller / HMI
* ASVG module with inbuilt HMIPDF page 101 Power Quality Solutions
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Power Quality Solutions
Active Harmonic Filter (AHF) [8543]
AHF
ACTIVE HARMONIC FILTER - MODULE ACTIVE HARMONIC FILTER
Features Features
› Reduces THD within IEEE - 519 limits › Reduces THD within IEEE - 519 limits
› Harmonic Mitigation, Dynamic Stepless PF correction & Load › Harmonic mitigation up to 50th Order
balancing › Harmonic Mitigation, Dynamic Stepless PF correction &
› Advanced 3 Level Inverter topology Load balancing
› Harmonic Mitigation up to 51st Order › With complete panel enclosure
› Fast response time of 50 µsec › Up to 1000 Amp in a single enclosure
› Lower thermal losses › Customizable to withstand in extreme environment
› Scalable architecture for future expansion › Communicable – Inbuilt MODBUS RS485 Protocol
› Communicable –Inbuilt MODBUS RS485 Protocol › Modular Design allowing for future expansion
› Wall mount/ Rack Mount Modules › Ease of Monitoring using Touch Screen HMI
› True Hybrid Solution Compatibility › Fully Customized as per site condition**
3P3W AHF (415 V,-25%+15%) 3P4W AHF (415 V,-25%+10%)
Ampere Contact your nearest sales office for customized solution.
Rating M.R.P. (`) M.R.P. (`)
Cat. No.* Cat. No.*
Per Unit Per Unit
3 Phase 3 wire AHF 3 Phase 4 wire AHF
* *
30 AHF0030H3WD2 AHF0030H4WD2 Ampere Without Neutral Compensation With Neutral Compensation
* * Rating M.R.P. (`) M.R.P. (`)
50 AHF0050H3WD2 AHF0050H4WD2 Cat. No.* Cat. No.*
* * Per Unit Per Unit
100 AHF0100H3WD2 AHF0100H4WD2
30 AHF030431D2 AHF030441D2
150 AHF0150H3WD2* On AHF0150H4WD2* On
Request Request 60 AHF060431D2 AHF060441D2
30 AHF0030N3RD2 AHF0030N4RD2
100 AHF100431D2 AHF100441D2
50 AHF0050N3RD2 AHF0050N4RD2
125 AHF125433D2 AHF125443D2
100 AHF0100N3RD2 AHF0100N4RD2
150 AHF150433D2 AHF150443D2
150 AHF0150N3RD2 AHF0150N4RD2
200 AHF200433D2 AHF200443D2
Hybrid Controller / HMI
250 AHF250433D2 On AHF250443D2 On
AHFHC18R00T Request Request
300 AHF300433D2 AHF300443D2
AHFHC00R18T 400 AHF400433D2 AHF400443D2
On
Request 500 AHF500433D2
AHFHC09R09T
600 AHF600433D2
AHFHMI007 750 AHF750433D2
1000 AHF000433D2
* AHF module with inbuilt HMI
*Standard CAT No. Configuration Cable Entry – Top/Cable Alley
**Customisable options available
IP Class – IP 40/IP 42/IP 54
Conformal Coating - (3C3)
Lauritz Knudsen, 15.08.2026 94PDF page 102 * Note: Hybrid Panel Combination - ASVG + APFC & AHF + APFC
Extracted reference text; use the original PDF to check column alignment, variants and price units.
* Note: Hybrid Panel Combination - ASVG + APFC & AHF + APFC
Suggested Step Ratings for APFC Panels
Panel No. of Electrical Steps (All No. of Panel No. of Electrical Steps (All No. of
Physical Step
Rating Physical Possible Combination Electrical Rating Physical Step Physical Possible Combination Electrical
Size (kVAr)
(kVAr) Steps of Physical Steps) Steps (kVAr) Size (kVAr) Steps of Physical Steps) Steps
10 4+3+2+1 4 1,2,3,4...8,9,10 10 120 50 + 25 + 20 + 15 + 4 + 2x3 7 3,4,6,7….114,116,117,120 85
15 5+4+3+2+1 5 1,2,3,4...13,14,15 15 125 50 + 2x25 + 15 + 4 + 2x3 7 3,4,6,7….119,121,122,125 55
20 10 + 5 + 2x2 + 1 5 1,2,3,4…18,19,20 20 130 50 + 2x25 + 20 + 4 + 2x3 7 3,4,6,7….124,126,127,130 60
25 15 + 5 + 2x2 + 1 5 1,2,3,4…23,24,25 20 135 2x50 + 15 + 10 + 4 + 2x3 7 3,4,6,7….129,131,132,135 65
30 15 + 10 + 2x2 + 1 5 1,2,3,4…28,29,30 22 140 2x50 + 20 + 10 + 4 + 2x3 7 3,4,6,7….134,136,137,140 62
35 20 + 10 + 2x2 + 1 5 1,2,3,4…33,34,35 23 145 2x50 + 25 + 10 + 4 + 2x3 7 3,4,6,7….139,141,142,145 65
40 20 + 10 + 5 + 3 + 2 5 2,3,5,7…35,37,38,40 24 150 2x50 + 25 + 15 + 4 + 2x3 7 3,4,6,7….144,146,147,150 66
45 25 + 10 + 5 + 3 + 2 5 2,3,5,7…40,42,43,45 24 155 2x50 + 25 + 15 + 3x5 7 5,10,15,20….145,150,155 31
50 25 + 15 + 5 + 3 + 2 5 2,3,5,10…45,47,48,50 24 175 2x50 + 2x25 + 10 + 3x5 8 5,10,15,20….165,170,175 35
55 25 + 15 + 10 + 3 + 2 5 2,3,5,10….50,52,53,55 25 200 2x50 + 3x25 + 15 + 2x5 8 5,10,15,20...190,195,200 40
60 25 + 15 + 10 + 5 + 3 + 2 6 2,3,5,7….55,57,58,60 36 225 3x50 + 2x25 + 15 + 10 7 10,15,25,35...210,215,225 27
65 25 + 2x15 + 5 + 3 + 2 6 2,3,5,7….60,62,63,65 35 250 3x50 + 3x25 + 15 + 10 8 10,15,25,35...235,240,250 30
70 25 + 20 + 15 + 5 + 3 + 2 6 2,3,5,7….65,67,68,70 36 275 4x50 + 2x25 + 15 + 10 8 10,15,25,35...260,265,275 33
75 2x25 + 15 + 5 + 3 + 2 6 2,3,5,7….70,72,73,75 39 300 100 + 2x50 + 3x25 + 15 + 10 8 10,15,25,35...285,290,300 36
80 2x25 + 15 + 10 + 3 + 2 6 2,3,5,10….75,77,78,80 36 325 100 + 3x50 + 2x25 + 15 + 10 8 10,15,25,35...310,315,325 39
85 50 + 20 + 5 + 4 + 2x3 6 2,3,5,6….80,81,82,85 44 350 100 + 4x50 + 25 + 15 + 10 8 10,15,25,35...335,340,350 42
90 50 + 25 + 5 + 4 + 2x3 6 3,4,5,6….85,86,87,90 47 375 2x100 + 2x50 +2x25 + 15 + 10 8 10,15,25,35…360,365,375 45
95 50 + 25 + 10 + 4 + 2x3 6 3,4,6,7….89,91,92,95 43 400 2x100 + 2x50 + 4x25 8 25,50,75,100…350,375,400 16
100 50 + 25 + 15 + 4 + 2x3 6 3,4,6,7….94,96,97,100 44 425 2x100 + 3x50 + 3x25 8 25,50,75,100…375,400,425 17
105 50 + 25 + 15 + 5 + 4 + 2x3 7 3,4,5,6….100,101,102,105 85 450 2x100 + 3x50 + 4x25 9 25,50,75,100…400,425,450 18
110 50 + 25 + 15 + 10 + 4 + 2x3 7 3,4,5,6….104,106,107,110 65 475 2x100 + 4x50 + 3x25 9 25,50,75,100…425,450,475 19
115 50 + 25 + 2x15 + 4 + 2x3 7 3,4,6,7….109,111,112,115 65 500 2x100 + 5x50 + 2x25 9 25,50,75,100…450,475,500 20
Note: Above mentioned steps are typical recommendations, suitable for most of the industries. For accurate compensation,
step size selection may have to be decided after studying load profile of that industry. Lauritz Knudsen, 15.08.2026 95PDF page 103 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 104 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 105 Protection Relays [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Protection Relays [8536]
Correlation between ANSI/IEEE device function number and relays
ANSI Code Function Name Protection Relays
Voltage and
Single Function Feeder Motor Protection
Frequency
eMPR
REF11 NDR11 OCR11 RPR11 TCS11 PTF11 VPR11 VPR21 VPR22 FDR21 FDR22 iMMR MM10 MPR21
300I
27 AC under-voltage relay ü ü ü ü
32 Power directional relay ü
Under current or under
37 ü ü ü ü
power relay
Reverse phase or phase
46 ü ü ü ü ü
balance current relay
Broken conductor
46BC ü
Protection
Phase-sequence or
47 single-phasing voltage ü ü ü
relay
Excessive Start Time
48 ü ü ü
Monitoring
Machine or transformer
49 ü ü ü ü ü
thermal Overload relay
Instantaneous
50 ü ü ü ü ü
overcurrent relay
Instantaneous Earth
50N ü ü ü ü ü
Fault relay
50BF Breaker - failure ü ü ü
AC time over current
51 ü ü ü ü ü
relay
Ground fault time over
current relay /
51N-(51G) ü ü ü ü ü
Standby Earth Fault
Relay
51LR Locked rotor ü ü ü ü
59 AC over-voltage relay ü ü ü ü
Neutral Displacement
59N ü ü ü
Relay
Positive Sequence
59D ü ü
Over-voltage protection
Restricted Earth Fault
64REF ü
Relay
64 Machine Ground Fault ü ü ü ü ü
66 Max. no. of starts ü ü
81 Frequency relay ü ü ü
Ground fault differential
87N-(87G) ü
protection relay*
Trip Circuit supervision
74TCS ü ü ü ü
Protection
Vector surge protection
78 ü
relay
Rate of change of
df/dt ü
frequency
Switch On to Fault
SOTF ü
Protection
PTFF PT Fuse failure ü
* REF11 is meant for Generator Differential Protection
Lauritz Knudsen, 15.08.2026 98PDF page 106 numrAL – Numerical Protection Relays with Draw-out enclosure [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
numrAL – Numerical Protection Relays with Draw-out enclosure [8536]
3 Phase non-directional Single Pole Over Voltage + Under Voltage Relay
Over Current + Earth Fault Relay
VPR11 - Single Pole Under Voltage and Over Voltage Relay (27, 59)
› FDR21 – 50, 51, 50N, 51N. › Microcontroller-based design
› Microcontroller-based design › Draw-out Enclosure
› Draw-out enclosure. › Single Phase OV + UV Protection
› CT rating#- 1A/ 5A (site selectable) › System Voltage – 110/ 230/ 415 VAC
› Display of 250 event and 30 Trip records (site programable)
› 128*64 graphical display › Inverse and definite time delay
› Display of Actual value and 5 Trip records
Aux. Supply (V) M.R.P. (`)
Model Communication Cat. No.
Per Unit
20 - 60V DC Non-Communicable NRFDR2A26NX 29680 M.R.P. (`)
numrAL Model Aux. Supply (V) Communication Cat. No.
85 - 265V AC, Per Unit
FDR21 Non-Communicable NRFDR2B26NX 29680
87 - 265V DC 20 - 60V DC Non-communicable NRVPR1A11NX 21560
#
- Protection Class CT 85 - 265V AC,
Non-communicable NRVPR1B11NX 21560
numrAL 87 - 265V DC
VPR11 20 - 60V DC Modbus RS 485 NRVPR1A11RA 26400
3 Phase non-directional 85 - 265V AC,
Modbus RS 485 NRVPR1B11RA 26400
87 - 265V DC
Over Current + Earth Fault Relay
› FDR22 - 46BC, 49, 50, 51, 50N, 51N, 50BF, 74TCS, SOTF
› Microcontroller-based design
› Draw-out enclosure.
› CT rating#- 1A/ 5A (site selectable)
› Display of 250 event and 30 Trip records
› 128*64 graphical display
› Modbus RS-485 Communication 3 Phase Voltage + Frequency Relay
› Front Micro USB port for numrAL Suite
› VPR21 – 27, 47, 59, 59N, 81O/U
M.R.P. (`) › Microcontroller-based design
Model Aux. Supply (V) Communication Cat. No.
Per Unit › Draw-out enclosure.
20 - 60V DC Modbus RS 485 NRFDR2A27RA 37520 › System Voltage – 110/ 230/ 415 VAC
numrAL
FDR22 85 - 265V AC, (site programable)
Modbus RS 485 NRFDR2B27RA 37520
87 - 265V DC
› Display of 250 event and 30 Trip records
- Protection Class CT
#
› 128*64 graphical display
M.R.P. (`)
Motor Protection Relay Model Aux. Supply (V) Communication Cat. No.
Per Unit
20 - 60V DC Non-Communicable NRVPR2A2ANX 33040
› MPR21 – 37, 46, 48, 49, 50BF, 50, 51, 50N, 51N, 51LR, 64, 66, 74TCS. numrAL
VPR21 85 - 265V AC,
› Microcontroller-based design Non-Communicable NRVPR2B2ANX 33040
87 - 265V DC
› Draw-out enclosure.
› CT rating#- 1A/ 5A (site selectable) R
› Display of 250 event and 30 Trip records 415VAC, Y
3 Phase,
› 128*64 graphical display 4 Wire B
› Modbus RS-485 Communication N
› Front Micro USB port for numrAL Suite
B
Y
Aux. Supply (V) M.R.P. (`) VPR21
Model Communication Cat. No.
Per Unit R
N
20 - 60V DC Modbus RS 485 NRMPR2A28RA 69000
numrAL
MPR21 85 - 265V AC,
Modbus RS 485 NRMPR2B28RA 69000
87 - 265V DC
# R
- Protection Class CT Y
B
R R
3 Phase,
3 Wire Y Y
B B
B
/110V PT
Y
VPR21
R
N
Lauritz Knudsen, 15.08.2026 99PDF page 107 numrAL – Numerical Protection Relays with Draw-out enclosure [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
numrAL – Numerical Protection Relays with Draw-out enclosure [8536]
Restricted Earth Fault Relay Neutral Displacement Relay
REF11 - Restricted Earth Fault Relay (87N/64REF) NDR11 - Neutral Displacement Relay (59N)
› Microcontroller-based design › Microcontroller-based design
› Draw-out Enclosure › Draw-out Enclosure
› CT rating - 1A/ 5A (site selectable)
$
› Single Phase OV Protection
› Single Phase high impedance Earth Fault › Definite & Normal inverse time delay
› Instantaneous and definite time delay › Display of Actual value and 5 Trip records
[50 msec to 1 sec (programmable)]
› Built in third harmonic filter Model Aux. Supply (V) Communication Cat. No.
M.R.P. (`)
Per Unit
› Display of Actual value and 5 Trip records
20 - 60V DC Non-communicable NRNDR1A11NX 21560
Aux. Supply (V) M.R.P. (`) 85 - 265V AC,
Model Communication Cat. No. Non-communicable NRNDR1B11NX 21560
Per Unit 87 - 265V DC
numrAL
20 - 60V DC Non-communicable NRREF1A10NX 21560 NDR11 20 - 60V DC Modbus RS 485 NRNDR1A11RA 26400
85 - 265V AC, 85 - 265V AC,
Non-communicable NRREF1B10NX 21560 Modbus RS 485 NRNDR1B11RA 26400
numrAL 87 - 265V DC 87 - 265V DC
REF11 20 - 60V DC Modbus RS 485 NRREF1A10RA 26400
85 - 265V AC,
Modbus RS 485 NRREF1B10RA 26400
87 - 265V DC
- PS Class CT
$
Transformer / Generator Restricted Earth Fault Protection
PS Class CT PS Class CT
$ $
Broken Delta PT
NDR11
Trip Circuit Supervision Relay
TCS11 – Trip Circuit Supervision Relay (74)
Single Pole Over Current OR Earth Fault Relay › Microcontroller-based design
› Draw-out Enclosure
OCR11 – Single pole Over Current or Earth Fault Relay
› Monitors Trip Coil in Breaker ON & OFF condition
(50, 51 OR 50N, 51N)
› Site selectable Trip Coil Voltage
› Microcontroller-based design
› Draw-out Enclosure M.R.P. (`)
Model Aux. Supply (V) Communication Cat. No.
› Single Phase OC/ EF Protection Per Unit
› CT rating# - 1A/ 5A (site selectable) 20 - 60V DC Non-Communicable NRTCS1A13NX 12880
numrAL
TCS11* 85 - 265V AC,
› Inverse and definite time delay Non-Communicable NRTCS1B13NX 12880
87 - 265V DC
› Display of Actual Current value and 5 Trip records
*Available on Request - Please contact our nearest branch for details
Aux. Supply (V) M.R.P. (`)
Model Communication Cat. No.
Per Unit
20 - 60V DC Non-communicable NROCR1A10NX 21560
PT Fuse Failure Relay
85 - 265V AC,
Non-communicable NROCR1B10NX 21560
numrAL 87 - 265V DC PTF11 – PT Fuse Failure Relay (PTFF/97)
OCR11 20 - 60V DC Modbus RS 485 NROCR1A10RA 26400 › Microcontroller-based design
85 - 265V AC, › Draw-out Enclosure
Modbus RS 485 NROCR1B10RA 26400
87 - 265V DC
› Monitors the healthiness of PT Fuse.
#
- Protection Class CT › 3 Separate sensing elements.
Aux. Supply (V) M.R.P. (`)
Model Communication Cat. No.
Per Unit
20 - 60V DC Non-Communicable NRPTF1A14NX 12880
numrAL
PTF11* 85 - 265V AC,
Non-Communicable NRPTF1B14NX 12880
OCR11 OCR11 OCR11 OCR11
87 - 265V DC
Earth Fault Standby Earth Earth Fault Single Phase Over Current *Available on Request - Please contact our nearest branch for details
Protection Fault Protection Protection Protection - 50, 51
50N, 51N 50N, 51N
Lauritz Knudsen, 15.08.2026 100PDF page 108 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 109 Protection Relays [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Protection Relays [8536]
Reverse Power Relay
RPR11 – Reverse Power Relay (32)
› Microcontroller-based design
› Draw-out Enclosure
› Site selectable System Voltage - 110V / 415VAC
Aux. Supply (V) M.R.P. (`)
Model Communication Cat. No.
Per Unit
numrAL 20 - 60V DC Modbus RS 485 NRRPR1A12RA *
RPR11* 85 - 265V AC, 87 - 265V DC Modbus RS 485 NRRPR1B12RA *
*Available on Request - Please contact our nearest branch for details
Insulation Monitoring Relay New
Application: Monitoring of insulation resistance between Live conductors and Earth (Ground) in case of Unearthed (IT) electrical systems.
Detection of insulation faults at earlier stage prevents electrical hazards such as electric shock, fire and equipment damage.
Features: Application Segments:
› Threshold resistance setting from 1K to 100K ohm 1.Railways
› Suitable for 1Phase and 3 Phase (Both 3W and 4W) 2.Hospitals and Pharma
› Test/Reset function with remote and manual facility 3.Data Centre
› Indication of Power ON, Relay output and Fault. 4.Mining
› Both fail safe and non-failsafe relay option available
M.R.P. (`)
Description Cat Code
Per Unit
System voltage up to 520V.
IMR520 13260
Adjustable from 1-100K Ω with 2C/O
Single Element Lockout Relay - LocR
Features
› Lockout Relays [Master Trip Relay] - LocR
› Designed to operate the circuit breaker trip coils at high speed
› Available with Hand reset contact (HRC) and hand reset Flag (HRF)
Description Output contacts Reset Contacts Reset Flag Coil Voltage Cat. No. M.R.P. (`) Per Unit
24VDC L1H32DC024X 6000
110VDC L1H32DC110X 6000
Single element
3NO + 2NC Hand Hand 220VDC L1H32DC220X 6000
Lockout relay
110VAC L1H32AC110X 6000
230VAC L1H32AC230X 6000
ANSI Code - 86
Three Element Auxiliary Relay - AuxR
Features
› AuxR relay provides additional contacts for interlocking, control and signal applications
› Available with hand reset or self-reset contacts and hand reset Flag
Description Output Contacts Reset Contacts Reset Flag Coil Voltage Cat. No. M.R.P. (`) Per Unit
24VDC A3H40DC024X 12000
110VDC A3H40DC110X 12000
Three element
4 N/O Hand Hand 220VDC A3H40DC220X 12000
Auxiliary relay
110VAC A3H40AC110X 12000
230VAC A3H40AC230X 12000
24VDC A3A22DC024X 12000
110VDC A3A22DC110X 12000
Three element
2 N/O + 2 N/C Auto Hand 220VDC A3A22DC220X 12000
Auxiliary relay
110VAC A3A22AC110X 12000
230VAC A3A22AC230X 12000
Lauritz Knudsen, 15.08.2026 102PDF page 110 Metering Devices [9028]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Metering Devices [9028]
Single Phase kWh meter 3 Phase 4 Wire kWh meter
with LCD display LCD type
Model EM101+ Class 1 Base mounting Model ER300P Base Mounting
M.R.P. M.R.P.
Description Cat. No. (`) Description Cat. No. (`)
Per Unit Per Unit
1P LCD Meter 5-30A WM101BC5DL0 2596 3Ph 4 W kWh CT op base mtg 240V, /5A, Acc 0.5s WR301BC3C00 8279
1P LCD Meter 5-30A with BOX WM101BC5DL0BOX 3461 3Ph 4 W kWh Dir base mtg 240V 5- 30 A Acc 1 WR301BC4D20 6934
1P LCD Meter 5-30A with OPTICAL PORT WM101BC5DDH 3567 3Ph 4 W kWh Dir base mtg 240V 10- 40 A Acc 1 WR301BC6D20 7135
1P LCD Meter 5-30A with Optical port + BOX WM101BC5DDHBOX 4432 3Ph 4 W kWh Dir base mtg 240V 10- 60 A Acc 1 WR301BC7D10 9038
1P LCD Meter 10-60A WM101BC7DL0 3061 3Ph 4 W kWh Dir base mtg 240V 20- 100 A Acc 1 WR301BC8D10 13097
1P LCD Meter 10-60A with BOX WM101BC7DL0BOX 3860
1P LCD Meter 10-60A with Optical Port WM101BC7DDH 3913
1P LCD Meter 10-60A with Optical Port + BOX WM101BC7DDHBOX 4499 Trivector Meter Class 0.5s
1P LCD Meter 5-30 with Optical Port + RS232 WM101BC5DLMSC 3993 Model ER300P Class 0.5s (Base Mounting)
› Inform CT/PT ratio while ordering
Trivector Meter Class 1 › Meters with DLMS Protocol (IS 15959)
whole current meter
Model ER300P Class 1 (Base Mounting) M.R.P.
Description Cat. No. (`)
Per Unit
M.R.P. 3Ph, 4W TVM 110V ( L-L) 1 A Class 0.5s BM RS 485 Modbus # WR300BB12RS 48848
Description Cat. No. (`)
Per Unit 3Ph, 4W TVM 110V ( L-L) 5 A Class 0.5s BM RS 485 Modbus # WR300BB52RS 48848
3Ph, 4W TVM 240V ( L-N) 5 A Cl 0.5s BM RS 485 Modbus * WR300BC52RS 43803
3Ph, 4W TVM 240 V 10 - 60A BM WR300BC7300 12219
3Ph, 4W TVM 240 V 10 - 60A BM with # - Available on request
WR300BC73BOXH 15134 * - Available on request only till stocks are cleared and minimum order Quantity
Hinge type Box*
is 100 nos
* - Available on request only and minimum order Quantity is 100 nos
Smart Meter Solutions$
Smart Meter (IS 16444) solutions please contact our nearest Branch
$
- Available on request
Trivector Meter Class 0.2s
Model ER300P Class 0.2s (Base Mounting)
› Inform CT/PT ratio while ordering
NET/ABT Meters$
› Meters with DLMS Protocol (IS 15959)
M.R.P.
Description Cat. No. (`)
Per Unit
3Ph, 4W TVM 110V ( L-L) 1 A Class 0.2s BM RS485 Modbus WR300BB11RS 105376
3Ph, 4W TVM 110V ( L-L) 5 A Class 0.2s BM RS485 Modbus WR300BB51RS 105376
Net Meters for solar roof top application & solar generation plant
please contact our nearest Branch
ORION (40-200A)$
Meter Reading Instrument [8471]
Description Cat. No. M.R.P. (`)
Per Unit
Meter Reading Instrument - (16.5 MB) 990MRIXX000 208581
Meter Optical port to USB cable 990PCXXUSB 2489 Combined CT Meter (Available for Generation and Net Metering)
$ For more details please contact nearest branch
SMART METERING SOLUTION
©2025. All Rights Reserved.
Powered by
Subscription Prepaid & Postpaid MeitY Certified Data Security,
based Software Metering Cloud Compliance & ReliabilityPDF page 111 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 112 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 113 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 114 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 115 Multifunction Meter Selection Chart
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Multifunction Meter Selection Chart
Basic Advanced
MFM
MFM MFM
Parameters Group Parameters
4400/
4410 4420 4425 4430 4440 5010 5000
4405
V1, V2, V3, V12, V23, V31, Avg (VLN, VLL) ü ü ü ü ü ü ü ü
A1, A2, A3, Aavg ü ü ü ü ü ü ü ü
An (Computed) ü ü ü ü ü ü ü
Frequency ü ü ü ü ü ü ü ü
% A Unbal, % V Unbal (Avg and Phase wise) ü ü ü ü ü ü ü
Instantaneous
PF-1, PF-2, PF-3, PF (Avg) ü ü ü ü ü ü ü ü
Parameters
RPM (Rotations per minute) ü ü ü ü ü ü ü
Phase Angle A°1, A°2, A°3, V°1, V°2, V°3 ü ü ü ü ü ü ü
W1, W2, W3, W(total) ü ü ü ü ü ü ü ü
VA1, VA2, VA3, VA(total) ü ü ü ü ü ü ü ü
VAr1, VAr2, VAr3, VAr (total) ü ü ü ü ü ü ü
Import Wh ü* ü ü ü ü ü ü ü
Import VAh ü* ü ü ü ü ü ü ü
Import VArh (Lead & Lag) ü ü ü ü ü ü ü
Import load hours ü ü ü ü ü ü ü ü
Cumulative
Export Wh ü ü ü ü
Parameters
Export VAh ü ü ü ü
Export VArh (Lead & Lag) ü ü ü ü
Export run hours ü ü ü ü
No of Interrupts ü ü ü ü ü ü ü
Import Wh ü ü ü ü ü ü ü ü
Import VAh ü ü ü ü ü ü ü
Import VArh (Lead & Lag) ü ü ü ü ü ü ü
Reset (old) Cumulative Import load hours ü ü ü ü ü ü ü ü
parameters Export Wh ü ü ü ü
Export VAh ü ü ü ü
Export VArh (Lead & Lag) ü ü ü ü
Export run hours ü ü ü ü
V THD%, V1, V2, V3 - harmonic ( 31 ) st
ü ü ü ü ü ü ü
Harmonic A THD%, A1, A2, A3, - harmonic (31st) ü ü ü ü ü ü ü
Individual harmonics upto 31 (V, A)
st
ü ü ü
Maximum demand MD W, MD VA,
ü ü
MD VAr - max avg A (without RTC)
Demand / Load
Maximum demand MD W, MD VA,
parameters ü ü ü ü
MD VAr - max avg A (with RTC)
Max MD & occurence time ü ü
Min / Max value VLL, VLN, A, F, W, VA, VAr, PF ü ü ü ü ü ü ü
Storage Datalog (8MB) ü
RS485 Modus RTU Optional Optional Optional Optional Optional Optional Optional
Communication
Ethernet Port (Modbus TCP/IP) ü Optional
Digital and Analog (input and output) Optional
Input and Output
Pulse Output Optional Optional
ü* User will see either kWh or kVAh on the display.
Lauritz Knudsen, 15.08.2026 108PDF page 116 Single Function Meters [9030] Energy Meters
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Single Function Meters [9030] Energy Meters [9030]
1xxx Series 4000 Series
› Accuracy Class 1.0, 0.5 › Accuracy Class 1.0, 0.5
› Input voltage measurement range 50-520 VAC (P-P) › Input voltage measurement range 50-520 VAC (P-P)
› Aux supply 80-300 V AC / DC › Aux supply 80-300 VAC/DC
› CT secondary site selectable 1A / 5A › CT secondary site selectable 1A / 5A
› Flush mounting 96 x 96 mm › Flush mounting 96 x 96 mm kWh or kVAh
› Inbuilt selector switch for 3 phase meters › CT/PT site programmable is site selectable
› CT/PT site programmable › Auto scaling of Kilo, Mega and Giga
› Frequency parameter available in 3Ph Voltmeter additionally › Parameters: Site selectable kWh / kVA / PF / W, Old energy
Energy display
in kWh in its
lifetime#
M.R.P. (`) M.R.P. (`)
Description Cat. No. Description Cat. No.
Per Unit Per Unit
1Ph LED Ammeter Cl 1 WL111010OOOO 1130 kWh LED meter Cl 1 WL400010OOOO 3500
1Ph LED Voltmeter Cl 1 WL112010OOOO 1130 kWh LED meter Cl 1 with RS485 WL400011OOOO 3875
3Ph LED Ammeter Cl 1 WL131010OOOO 1725 kWh LED meter Cl 0.5 WL400020OOOO 4445
3Ph LED Voltmeter Cl 1 WL132010OOOO 1725 kWh LED meter Cl 0.5 with RS485 WL400021OOOO 4825
LED Freq meter Cl 0.2 WL113040OOOO 1130 kWh LCD meter Cl 1 WC400010OOOO 3965
1Ph LED Ammeter Cl 0.5 WL111020OOOO 1590 kWh LCD meter Cl 1 with RS485 WC400011OOOO 4380
1Ph LED Voltmeter Cl 0.5 WL112020OOOO 1590 kWh LCD meter Cl 0.5 WC400020OOOO 4910
3Ph LED Ammeter Cl 0.5 WL131020OOOO 2000 kWh LCD meter Cl 0.5 with RS485 WC400021OOOO 5285
3Ph LED Voltmeter Cl 0.5 WL132020OOOO 2000 # For 415V LL and CT Primary value of 400 and below
VAF, VAF + PF Meters [9030] DIN Type Basic Multifunction Meters [9030]
41XX Series › Accuracy Class 1.0, 0.5
› Input voltage measurement range New 40x0 Series
50-520 VAC (P-P) › DIN mounting whole current
› Aux supply 80-300 VAC/DC operated meter
› CT secondary site selectable 1A / 5A › Accuracy Class 1.0
› Flush mounting 96 x 96 mm
› Inbuilt RS485 option
› Parameters:VLL, VLN, A, F, PF, On Hrs,
RPM › Parameters : Voltage, Current, kW, kWh, kVA, kVAh, RPM, Load
hours, Interruptions
M.R.P. (`) Description M.R.P. `)
Description Cat. No. Module Cat. No.
Per Unit Per Unit
Single Phase - 60A 2 WD401010OOOO 3940
VAF meter, Cl 1 New WL410010OOOO 1935
Three Phase - 80A 5 WD402010OOOO 8530
VAF + PF meter, Cl 1 WL411010OOOO 3210 Single Phase - 60A (RS485) 2 WD401011OOOO 5825
VAF + PF meter with RS485, Cl 1 WL411011OOOO 4030 Three Phase - 80A (RS485) 5 WD402011OOOO 12870
VAF + PF meter, Cl 0.5 WL411020OOOO 3690
VAF + PF meter with RS485, Cl 0.5 WL411021OOOO 4465PDF page 117 Dual Source Basic MFM [9030] Basic Multifunct
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Dual Source Basic MFM [9030] Basic Multifunction Meters [9030]
4040 Series 4405 Series
kWh or kVAh
Features is site selectable Features All parameters
of 4400 series
› Accuracy Class 1.0, 0.5 › Accuracy Class 1.0, 0.5 in 3 line
› Input voltage measurement range 50-520 VAC (P-P) › Input voltage measurement range LED display
› Aux supply 80-300 VAC/DC 50-520 VAC
› CT secondary site selectable 1A / 5A › Aux supply 80-300 VAC/DC
› DG sensing input 230 VAC › CT secondary site selectable 1A / 5A
› Flush mounting 96 X 96 mm › Flush mounting 96 x 96 mm
› CT/PT site programmable › CT/PT site programmable
› Discrete LED for EB and DG › V, A, F, PF, kW, kVA, Old energy, On and Run hours,
› True PF or Displacement PF site selectable site selectable kWh/ kVAh
› Parameters on Display : kW, kVA, PF, Run hours, kWh › True PF or Displacement PF site selectable
(EB and DG), Old energy, Site selectable kWh / kVAh
M.R.P.
› Parameters on Communication : V, A, F, kW, kVA, PF, Run hours, Description Cat. No. (`)
kWh (EB and DG), Old energy, Site selectable kWh / kVAh Per Unit
MFM 4405 LED meter Cl 1 WL440510OOOO 7485
MFM 4405 LED meter Cl 1 with RS485 WL440511OOOO 8455
LCD offers better readability
of parameters MFM 4405 LED meter Cl 0.5 with RS485 WL440521OOOO 9720
MFM 4405 LED meter Cl 0.5S with RS485 WL440531OOOO 9790
M.R.P.
Description Cat. No. `)
Per Unit
Dualsource LED meter Cl1 WL404010OOOO 6040 Multifunction Meters [9030]
Dualsource LED meter Cl1 with RS485 WL404011OOOO 7100
Dualsource LED meter Cl0.5 WL404020OOOO 7170 Features
Dualsource LED meter Cl0.5 with RS485 WL404021OOOO 8400 › Accuracy Class 1.0, 0.5, 0.5S, 0.2, 0.2S
Dualsource LCD meter Cl1 WC404010OOOO 6640
› Input voltage measurement range 50-520 VAC (P-P)
› Aux supply 80-300 VAC/DC
Dualsource LCD meter Cl1 with RS485 WC404011OOOO 7725
› CT secondary site selectable 1A / 5A True and
Dualsource LCD meter Cl0.5 WC404020OOOO 7785 › Flush mounting 96 x 96 mm Displacement
PF available
Dualsource LCD meter Cl0.5 with RS485 WC404021OOOO 8915 › CT/PT site programmable
› 128 samples / cycle
› My favourite page in LCD multifunction meters site selectable
Basic Multifunction Meters [9030] for kWh + 2 parameters
› Dedicated buttons available for direct access to Basic, Power
and Energy parameters
4400 Series
Features Constant Wh viewing in LCD
MFM even in auto scroll mode.
› Accuracy Class 1.0, 0.5
LCD offers better readability
› Input voltage measurement range 50-520 VAC of parameters
› Aux supply 80-300 VAC/DC
› CT secondary site selectable 1A / 5A 4410 Series
› Flush mounting 96 x 96 mm › Parameters: V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh,
› CT/PT site programmable Runhours, On hours, Phase angle, Interrupts, THD, Events (High-
› True PF or Displacement PF site selectable Low), Neutral Current, K Factor
› V, A, F, PF, kW, kVA, Old energy, Load hours, site selectable
M.R.P.
kWh/ kVAh Description Cat. No. (`)
Per Unit
MFM 4410 LED meter Cl 1 WL441010OOOO 10840
LCD offers better readability MFM 4410 LED meter Cl 1 with RS485 WL441011OOOO 12185
of parameters
MFM 4410 LED meter Cl 0.5 with RS485 WL441021OOOO 14005
MFM 4410 LED meter Cl 0.5S with RS485 WL441031OOOO 15480
M.R.P. MFM 4410 LED meter Cl 0.2 with RS485 WL441041OOOO 18430
Description Cat. No. (`)
Per Unit MFM 4410 LED meter Cl 0.2S with RS485 WL441051OOOO 23590
MFM 4400 LED meter Cl 1 WL440010OOOO 5790 MFM 4410 LCD meter Cl 1 WC441010OOOO 12745
MFM 4400 LED meter Cl 1 with RS485 WL440011OOOO 6685 MFM 4410 LCD meter Cl 1 with RS485 WC441011OOOO 13640
MFM 4400 LED meter Cl 0.5 with RS485 WL440021OOOO 7680 MFM 4410 LCD meter Cl 0.5 with RS485 WC441021OOOO 15910
MFM 4400 LED meter Cl 0.5S with RS485 WL440031OOOO 7760 MFM 4410 LCD meter Cl 0.5S with RS485 WC441031OOOO 17430
MFM 4400 LCD meter Cl 1 WC440010OOOO 6090 MFM 4410 LCD meter Cl 0.2 with RS485 WC441041OOOO 20465
MFM 4400 LCD meter Cl 1 with RS485 WC440011OOOO 7065 MFM 4410 LCD meter Cl 0.2S with RS485 WC441051OOOO 25760
Lauritz Knudsen, 15.08.2026 110PDF page 118 Multifunction Meters [9030] Advanced Multifuncti
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Multifunction Meters [9030] Advanced Multifunction Meters [9030]
4420 Series Max Demand Indicator 5000 Series
(without Real time clock)
Features
Parameters Standard True and
2 Relay outputs
› Datalog (8 MB)
› All parameters of 4410 series for MD Alarm › Bi-directional (Import - Export)
Displacement
PF available
› Maximum Demand (kW or kVA) › 128 samples/ cycle
M.R.P. › Analog I/O, digital I/O variants available
Description Cat. No. (`)
Per Unit › Meter with Built-in Ethernet port available
MFM 4420 LED meter Cl 1 WL442010OOOO 15965 Parameters
MFM 4420 LED meter Cl 1 with RS485 WL442011OOOO 17135 › V, A, F, kW, KVA, kVAr, kWh, kVAh, kVArh, PF, Runhr, Onhr, Interupts,
MFM 4420 LED meter Cl 0.5 with RS485 WL442021OOOO 18810 Phase angle, THD, Neutral current, Max Demand (with RTC) K Factor
MFM 4420 LED meter Cl 0.5S with RS485 WL442031OOOO 20260 › Bi-directional (Import-Export)
MFM 4420 LED meter Cl 0.2 with RS485 WL442041OOOO 23155 › Events (high-low) with time stamp
MFM 4420 LED meter Cl 0.2S with RS485 WL442051OOOO 28220
› Individual Harmonics upto 31st.
MFM 4420 LCD meter Cl 1 WC442010OOOO 18285
› My favourite page in LCD multifunction meters site selectable for
MFM 4420 LCD meter Cl 1 with RS485 WC442011OOOO 19585
kWh + 2 parameters
MFM 4420 LCD meter Cl 0.5 with RS485 WC442021OOOO 21225
MFM 4420 LCD meter Cl 0.5S with RS485 WC442031OOOO 22735
MFM 4420 LCD meter Cl 0.2 with RS485 WC442041OOOO 25760
Constant Wh viewing in LCD
MFM 4420 LCD meter Cl 0.2S with Rs485 WC442051OOOO 31080 MFM even in auto scroll mode.
LCD offers better readability
For Max Demand Controller (with Real time clock)
of parameters
please refer 6000 series
4425 Series MFM for Import-Export New Description Cat. No.
M.R.P.
(`)
Parameters Per Unit
› All parameters of 4420 series with Bi-directional (Import-Export) MFM 5000 LED meter Cl 1 with RS485 WL500011OOOO 48500
› Demand parameters with Individual Harmonics up to 31st order WL500012OOOO
MFM 5000 LED meter Cl 1 with Ethernet 55110
› Built-in Ethernet port for communication
MFM 5000 LED meter Cl 0.5 with Ethernet WL500022OOOO 57470
M.R.P.
Description Cat. No. (`) MFM 5000 LED meter Cl 0.5S with Ethernet WL500032OOOO 59055
Per Unit
MFM 5000 LCD meter Cl 1 with RS485 WC500011OOOO 50095
MFM 4425 LED meter I/E Cl 1 with Ethernet WL442512OOOO 22175
MFM 4425 LED meter I/E Cl 0.5s with Ethernet WL442532OOOO 26215 MFM 5000 LCD meter Cl 1 with Ethernet WC500012OOOO 56690
MFM 4425 LED meter I/E Cl 0.2S with Ethernet WL442552OOOO 29570 MFM 5000 LCD meter Cl 0.5 with RS485 WC500021OOOO 52435
MFM 5000 LCD meter Cl 0.5S with RS485 WC500031OOOO 54020
4430 Series MFM for Import-Export MFM 5000 LCD meter Cl 0.5 with Ethernet WC500022OOOO 59055
Parameters Standard MFM 5000 LCD meter Cl 0.5S with Ethernet WC500032OOOO 60615
› All parameters of Model 4420 series 2 Relay outputs
for MD Alarm MFM 5000 LCD meter Cl 0.2 with RS485 WC500041OOOO 57160
› Bi-directional (Import-Export)
MFM 5000 LCD meter Cl 0.2S with RS485 WC500051OOOO 62675
M.R.P.
Description Cat. No. (`) MFM 5000 LED meter Cl 1 RS485 2A/O WL500011OBOO
Per Unit
MFM 5000 LED meter Cl 0.5 RS485 2D/I WL500021OOBO
MFM 4430 LED meter Cl 1 WL443010OOOO 22405
MFM 4430 LED meter Cl 1 with RS485 WL443011OOOO 23370 MFM 5000 LED meter Cl 0.5 RS485 4D/O WL500021OOOD
Price on
MFM 4430 LED meter Cl 0.5 with RS485 WL443021OOOO 24795 request
MFM 5000 LCD meter Cl 1 RS485 2A/O WC500011OBOO
MFM 4430 LED meter Cl 0.5S with RS485 WL443031OOOO 26170
MFM 4430 LED meter Cl 0.2 with RS485 WL443041OOOO 28935 MFM 5000 LCD meter Cl 0.5 RS485 2D/I WC500021OOBO
MFM 4430 LED meter Cl 0.2S with RS485 WL443051OOOO 33760 MFM 5000 LCD meter Cl 0.5 RS485 4D/O WC500021OOOD
MFM 4430 LCD meter Cl 1 WC443010OOOO 23820
MFM 5000 LCD meter Cl 1 + RS485, 1AO, 1DO WC500011OAOA
MFM 4430 LCD meter Cl 1 with RS485 WC443011OOOO 24740
MFM 4430 LCD meter Cl 0.5 with RS485 WC443021OOOO 26170
MFM 4430 LCD meter Cl 0.5S with RS485 WC443031OOOO 27555 5000 series with Digital outputs are preconfigured for
MFM 4430 LCD meter Cl 0.2 with RS485 WC443041OOOO 30310 I - THD% at 8% and True PF at 0.98.
MFM 4430 LCD meter Cl 0.2S with RS485 WC443051OOOO 35140 Meter can be site selected for parameters and values - A THD, VTHD,
VA, W, under PF, under/over (VLL, A, F) with programmable trip time
4440 Series (1 to 180 sec) to protect the equipments from electrical
Parameters abnormalities.
› All parameters of 4410 series
› Maximum Demand with Real Time Clock (RTC) Data Log Interval
› Events (high-low) with time stamp Parameters 15 Min 30 Min 45 Min 60 Min
M.R.P. No. of Days
Description Cat. No. (`) 1 10230 20460 30690 40920
Per Unit
MFM 4440 LED meter Cl 1 with RS485 WL444011OOOO 19025 2 6820 13640 20460 27280
MFM 4440 LED meter Cl 0.5 with RS485 WL444021OOOO 21385 4 4092 8184 12276 16368
MFM 4440 LED meter Cl 0.2 with RS485 WL444041OOOO 26145 9 2046 4092 6138 8184
MFM 4440 LCD meter Cl 1 with RS485 WC444011OOOO 20610
14 1364 2728 4092 5456
MFM 4440 LCD meter Cl 0.5 with RS485 WC444021OOOO 22975
29 682 1364 2046 2728
MFM 4440 LCD meter Cl 0.2 with RS485 WC444041OOOO 27735
Lauritz Knudsen, 15.08.2026 111PDF page 119 Advanced Multifunction Meters [9030]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Advanced Multifunction Meters [9030]
5010 Series
Features True and
Displacement
› 128 samples / cycle PF available
› Running demand, max demand, prediction
demand in single page window M.R.P.
Parameters Description Cat. No. (`)
Per Unit
› V, A, F, kW, KVA, kVAr, kWh, kVAh, kVArh, PF, Runhr, Onhr, Interrupts,
Phase angle, THD, Neutral current, Max Demand (with RTC) MFM 5010 LED meter Cl 1 WL501010OOOO 16975
› Bi-directional (Import-Export) MFM 5010 LED meter Cl 1 with RS485 WL501011OOOO 17705
› Events (high-low) with time stamp MFM 5010 LED meter Cl 0.5S WL501030OOOO 20880
› Individual Harmonics upto 31st. WL501031OOOO
MFM 5010 LED meter Cl 0.5S with RS485 22035
MFM 5010 LED meter Cl 0.2 with RS485 WL501041OOOO 24355
Maximum Demand Controller [9030]
Parameters
6000 Series
› V, A, F, kW, KVA, kVAr, kWh, kVAh, kVArh, PF, Runhr, Onhr, Intr,
Features Phase angle, THD, Events, Neutral current, Max Demand (with RTC)
› Accuracy Class 1.0, 0.5S
› Input voltage measurement range 50-520 VAC (P-P)
› Aux supply 80-300 VAC/DC True and
› CT secondary site selectable 1A / 5A Displacement
8MB Datalog - Configurable
PF available
› Flush mounting 96 x 96 mm for 29 parameters including
kWh, Demand and
› CT/PT site programmable Harmonics for
Minimum 1 mins interval
› Datalog (8MB) M.R.P.
Description Cat. No. (`)
› 4 relay outputs for Max. demand controller Per Unit
› Time of Day (TOD) 6 slots available MDC 6000 LED meter Cl 1 with RS485 WL600011OOOO 43030
› Block/sliding window site selectable
MDC 6000 LED meter Cl 0.5S with RS485 WL600031OOOO 47175
› Running demand, max demand, prediction demand in
single page window MDC 6000 LCD meter Cl 1 with RS485 WC600011OOOO 44680
› Individual harmonics upto 31st. MDC 6000 LCD meter Cl 0.5S with RS485 WC600031OOOO 48825
Power Quality Meter Range [9030]
WC7000 – Power Quality Monitor New WC8000 – Power Quality Analyzer New
Parameters Parameters
› 512 samples/cycle with Class 0.2s accuracy as per IEC 62053-22 › 1024 samples/cycle with Class 0.2s accuracy as per IEC 62053-22
› LCD display with 4-digit instantaneous & 8-digit integrated readings › Class A metering as per IEC 61000-4-30
› Dual Communication Port (RS485 + Ethernet) with Web Server › 5.0” Color TFT with capacitive touch
› PQ Parameters Recording & monitoring like THD, TDD, Harmonics › PQ Parameters Recording & monitoring like THD, TDD, Odd, Even &
(up to 63rd order), Sag, Swell & Interruption. Inter Harmonics (up to 127st order), Sag, Swell, Transient, Flicker,
› USB Port for Downloading Data Log RVC & Interruption.
› TOU with up to 8 slots › USB port for data log download as well as Event Data in
› Standard 2DI & 2 DO CommTrade Format
› Dual Communication Port (RS485 + Ethernet) with Web Server
› MQTT, SMTP, SNTP protocols for secured cloud publishing
› Report Generation - IEC 61000 - 4 - 30, IEEE 519, EN 50160,
ITIC/CBEMA Curve
M.R.P.
Description Cat. No. (`)
Per Unit
PQM 7000 LCD Cl0.2s RS485+Eth DL, sag+swell WC700053OOBB Price
request
on
M.R.P.
Description Cat. No. (`)
Per Unit
PQA 8000 Class A TFT Cl0.2s RS485+Eth DL WC800053OOOO Price
request
on
Lauritz Knudsen, 15.08.2026 112PDF page 120 New SmartComm Edge [8517]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
New SmartComm Edge [8517]
Gateways and converters form the backbone of interconnected networks, and are a crucial link between our devices and
cloud-based or on-premises software. They facilitate seamless communication, protocol translation, and data
aggregation from various type of devices, enabling efficient data transmission and integration.
TG1000 MQ1000 *
› Modbus RS485 to MODBUS TCP/IP Gateway › MQTT Gateway with Ethernet port
› Easy integration with SmartComm EMS/PMS › Only Compatible with SmartComm EMS Cloud
On-prem or 3rd party Software/HMI › Compact & Secure
› Data storage in case of network failure
› Web browser-based configuration
M.R.P.
Description Cat. No. (`)
Per Unit
MODBUS RTU to TCP/IP Gateway TG1000OOOO 26620
MQ2000 * XR SERIES *
› 4G IoT Gateway with Sim Card (Modbus RS485 › 4G IoT Gateway with Dual Sim (Modbus RS485,
and MQTT support) Modbus TCP/IP and MQTT support)
› Only Compatible with SmartComm EMS Cloud, › Only Compatible with SmartComm Operate
SmartComm Operate and SmartComm IMS › Advanced VPN Routing
› Compact & Secure › Wide range of Industrial protocols support:
› Data storage in SD Card in case of network IEC60870-5-101 Master / Slave ,
failure IEC 60870-5-104 Master / Slave ,
› 4G with 2G fall back cellular connectivity IEEE 62056-21 DLMS , DNP3 Slave
Thermal Monitoring Module
TMZ * ZG1000 *
› Monitor temperature remotely Only Compatible with TMZ
› Wireless monitoring of 8 critical joints in a › IEEE 802.15.4 to Modbus TCP/IP Gateway
switchboard with a single module › Built-in webpages for ease of monitoring and
› Quick Installation and seamless Monitoring multi-client support
› Integrates with SmartComm PMS/HMI/any 3rd
party software on the Modbus TCP/IP side
*For more details, please contact the nearest branch office
LTXX Series
*
Industrial Managed Ethernet Switch
Cyber-hardened (IEC 62443-4-1 & IEC 62443-4-2)
IEC 61850-3 & IEEE 1613 Compliant
› Managed Ethernet Switches with 8, 16, 24 Ports
› Redundant Ring with recovery time less than 30ms
› Supports RSTP/ MSTP, MRP protocol
› IEC 61850-3/IEEE 1613 certified Ethernet switch with up to 10Gb/s connection
*For further details please contact nearest branch.
Lauritz Knudsen, 15.08.2026 113PDF page 121 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 122 AC Drives [8504]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
AC Drives [8504]
Input M.R.P.
Frame
Description Cat. No. (`)
Range : 0.37kW HD to 30kW ND Voltage Size
Per Unit
xD1000 415V Drive 0.37kW(HD) XD1000-01P5-4B1111 S1 *
xD1000 415V Drive 0.75kW(HD) XD1000-02P3-4B1111 S1 *
xD1000 415V Drive 1.50kW(HD) XD1000-04P1-4B2111 S2 *
xD1000 415V Drive 2.20kW(HD) XD1000-05P5-4B2111 S2 *
xD1000 415V Drive 3.00kW(HD)/4.00kW(ND) XD1000-08P9-4B2111 S3 *
Three
xD1000 415V Drive 4.00kW(HD)/5.50kW(ND) XD1000-12P1-4B2111 S3 *
Phase
xD1000 415V Drive 5.50kW(HD)/7.50kW(ND) XD1000-16P0-4B2111 S3 *
415 VAC
xD1000 415V Drive 7.50kW(HD)/11.0kW(ND) XD1000-22P8-4B2111 S4 *
xD1000 415V Drive 11.0kW(HD)/15.0kW(ND) XD1000-30P0-4B2111 S4 *
xD1000 415V Drive 15.0kW(HD)/18.5kW(ND) XD1000-36P0-4B2111 S5 *
xD1000 415V Drive 18.5kW(HD)/22.0kW(ND) XD1000-43P0-4B2111 S5 *
› Rated @ 55oC (HD), @ 50oC (ND) xD1000 415V Drive 22.0kW(HD)/30.0kW(ND) XD1000-60P0-4B2111 S6 *
› Transient overtorque 170%~200% Note: * For prices please contact nearest branch office
› 4 DIs, 2 DOs,1AI, 1AO Ordering Information for xD1000 AC Drive
› Inbuilt PID with 4 Preset PID references, xD 1 0 0 0 - 4 B 1 1 1
Sleep & Wakeup, Predictive speed Future Use 1 : Future Use
› Auxiliary Pump control EMC Filter 1 : Without EMC Filter
› Catch on the Fly DC Reactor 1 : Without DC Reactor
2 : With Braking Unit
› Skip Frequency Braking Unit
1 : Without Braking Unit
› Automatic Restart IP Class B: IP20
› Stall Prevention Mains Voltage 4: 3Ph, 380-460 VAC
› Current limiting function Current Rating
Model no.
Drives
Input M.R.P.
Frame
Description Cat. No.
Range : 0.37kW HD to 160kW ND Voltage Size
(`)
Per Unit
XD2000 415V Drive 0.37kW(HD)/0.75kW(ND) XD2000-02P2-4B1121 S1 *
XD2000 415V Drive 0.75kW(HD)/1.50kW(ND) XD2000-04P0-4B1121 S1 *
XD2000 415V Drive 1.50kW(HD)/2.20kW(ND) XD2000-05P6-4B1121 S1 *
XD2000 415V Drive 2.20kW(HD)/3.00kW(ND) XD2000-07P2-4B1121 S1 *
XD2000 415V Drive 3.00kW(HD)/4.00kW(ND) XD2000-09P3-4B1221 S1 *
XD2000 415V Drive 4.00kW(HD)/5.50kW(ND) XD2000-12P7-4B1221 S1 *
XD2000 415V Drive 5.50kW(HD)/7.50kW(ND) XD2000-15P8-4B1221 S1 *
XD2000 415V Drive 7.50kW(HD)/11.0kW(ND) XD2000-23P5-4B1221 S2 *
XD2000 415V Drive 11.0kW(HD)/15.0kW(ND) XD2000-31P7-4B1221 S2 *
Three
XD2000 415V Drive 15.0kW(HD)/18.5kW(ND) XD2000-39P2-4B1221 S3 *
Phase
XD2000 415V Drive 18.5kW(HD)/22.0kW(ND) XD2000-46P3-4B1221 S3 *
415 VAC
XD2000 415V Drive 22.0kW(HD)/30.0kW(ND) XD2000-61P5-4B1221 S4 *
XD2000 415V Drive 30.0kW(HD)/37.0kW(ND) XD2000-74P5-4B1221 S4 *
› Suitable for non-regenerative applications
XD2000 415V Drive 37.0kW(HD)/45.0kW(ND) XD2000-88P0-4B1221 S4 *
› Rated for -15 to 45oC HD as well as ND
XD2000 415V Drive 45.0kW(HD)/55.0kW(ND) XD2000-120P-4B1221 S5 *
ratings
XD2000 415V Drive 55.0kW(HD)/75.0kW(ND) XD2000-145P-4B1221 S5 *
› Inbuilt EMC filter with Category C3 EMC levels
XD2000 415V Drive 75.0kW(HD)/90.0kW(ND) XD2000-173P-4B1221 S5 *
› Inbuilt DC reactor from 4 kW to 160kW
XD2000 415V Drive 90.0kW(HD)/110kW(ND) XD2000-211P-4B1221 S6 *
› Inbuilt detachable LCD keypad
XD2000 415V Drive 110kW(HD)/132kW(ND) XD2000-250P-4B1221 S6 *
› 6 DIs, 3 ROs, 3 AIs, 2 AOs
XD2000 415V Drive 132kW(HD)/160kW(ND) XD2000-302P-4B1221 S6 *
› External 24 VDC connection to keep control
circuit alive during power outage Note:
* For prices please contact nearest branch office
› Pump and Compressor specific functions Drives are covered under HS code 8504 40 90 and are charged at 18% GST.
› 2 functions to one DI
› Torque Boost (IR Compensation) Ordering Information for xD2000 AC Drive
› Slip Compensation xD 2 0 0 0 - 4 B 1 1
› Auto Tuning Future Use 1 : Future Use
2 : With EMC Filter
› Decel. Ramp Adaptation EMC Filter
1 : Without EMC Filter
› 16 Preset speeds
2 : With DC Reactor
› Skip (Jump) Frequency DC Reactor
1 : Without DC Reactor
› Current Limitation Braking Unit 1 : Without Braking Unit
› DC Braking / Stop IP Class B: IP20
Mains Voltage 4: 3Ph, 380-460 VAC
› Freewheel Stop & Fast Stop Drives Model no. Current Rating
Lauritz Knudsen, 15.08.2026 115PDF page 123 AC Drives [8504]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
AC Drives [8504]
Range: 0.18kW HD to 15kW HD
Input M.R.P.
Description Cat. No. Frame
Voltage (`)
Size
Per Unit
XD3000 230V 1Ph Drive 0.18kW(HD) XD3000-01P5-1B2121 S1 *
XD3000 230V 1Ph Drive 0.37kW(HD) XD3000-03P3-1B2121 S1 *
Single
XD3000 230V 1Ph Drive 0.55kW(HD) XD3000-03P7-1B2121 S1 *
Phase
XD3000 230V 1Ph Drive 0.75kW(HD) XD3000-04P8-1B2121 S1 *
230 VAC
XD3000 230V 1Ph Drive 1.10kW(HD) XD3000-06P9-1B2121 S2 *
XD3000 230V 1Ph Drive 1.50kW(HD) XD3000-08P0-1B2121 S2 *
XD3000 230V 1Ph Drive 2.20kW(HD) XD3000-11P0-1B2121 S2 *
XD3000 230V 3Ph Drive 0.18kW(HD) XD3000-01P5-2B2111 S1 *
XD3000 230V 3Ph Drive 0.37kW(HD) XD3000-03P3-2B2111 S1 *
XD3000 230V 3Ph Drive 0.55kW(HD) XD3000-03P7-2B2111 S1 *
XD3000 230V 3Ph Drive 0.75kW(HD) XD3000-04P8-2B2111 S1 *
XD3000 230V 3Ph Drive 1.10kW(HD) XD3000-06P9-2B2111 S2 *
› Suitable for machine applications
XD3000 230V 3Ph Drive 1.50kW(HD) XD3000-08P0-2B2111 S2 *
› Rated for -10 to 50oC ambient temperature Three
XD3000 230V 3Ph Drive 2.20kW(HD) XD3000-11P0-2B2111 S2 *
› Inbuilt EMC filter for EMC category C2 Phase
XD3000 230V 3Ph Drive 3.00kW(HD) XD3000-13P7-2B2111 S3 *
› Inbuilt braking transistor 230 VAC
XD3000 230V 3Ph Drive 4.00kW(HD) XD3000-17P5-2B2111 S3 *
› 6 DIs, 3 DOs, 3 AIs, 1 AOs, 1 STO input
› External 24 VDC to keep control circuit on
XD3000 230V 3Ph Drive 5.50kW(HD) XD3000-27P5-2B2111 S4 *
during power outages
XD3000 230V 3Ph Drive 7.50kW(HD) XD3000-33P0-2B2111 S4 *
› Delinearization for Analog Inputs XD3000 230V 3Ph Drive 11.0kW(HD) XD3000-54P0-2B2111 S5 *
› Reference Addition, Subtraction & XD3000 230V 3Ph Drive 15.0kW(HD) XD3000-66P0-2B2111 S5 *
Multiplication XD3000 415V 3Ph Drive 0.37kW(HD) XD3000-01P5-4B2121 S2 *
› Hoisting - External Brake Control, Load XD3000 415V 3Ph Drive 0.55kW(HD) XD3000-01P9-4B2121 S2 *
(External Weight) Measurement, High- XD3000 415V 3Ph Drive 0.75kW(HD) XD3000-02P3-4B2121 S2 *
speed Hoisting, Rope Slack XD3000 415V 3Ph Drive 1.10kW(HD) XD3000-03P0-4B2121 S2 *
› Motor / Generator Torque Limit XD3000 415V 3Ph Drive 1.50kW(HD) XD3000-04P1-4B2121 S2 *
Three
› Line Contactor Control & Output Contactor XD3000 415V 3Ph Drive 2.20kW(HD) XD3000-05P5-4B2121 S3 *
Phase
Control XD3000 415V 3Ph Drive 3.00kW(HD) XD3000-07P1-4B2121 S3 *
415 VAC
› Positioning by Limit Switches or Sensors XD3000 415V 3Ph Drive 4.00kW(HD) XD3000-09P5-4B2121 S3 *
› Traverse control for textile machines XD3000 415V 3Ph Drive 5.50kW(HD) XD3000-14P3-4B2121 S4 *
› 8 nos. trip history XD3000 415V 3Ph Drive 7.50kW(HD) XD3000-17P0-4B2121 S4 *
XD3000 415V 3Ph Drive 11.0kW(HD) XD3000-27P7-4B2121 S5 *
XD3000 415V 3Ph Drive 15.0kW(HD) XD3000-33P0-4B2121 S5 *
Note:
* For prices please contact nearest branch office
Ordering Information for xD3000 AC Drive
xD 3 0 0 0 - B 1
Future Use 1 : Future Use
2 : With EMC Filter
EMC Filter
1 : Without EMC Filter
DC Reactor 1 : Without DC Reactor
Braking Unit 2 : With Braking Unit
IP Class B: IP20
1: 1Ph, 200~240VAC
Mains Voltage 2 : 3Ph, 200~240VAC
4: 3Ph, 380-460 VAC
Current Rating
Model no.
Drives
Lauritz Knudsen, 15.08.2026 116PDF page 124 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 125 AC Drives [8504]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
AC Drives [8504]
Range : 0.37kW HD to 315kW ND
Input M.R.P.
Description Cat. No. Frame
Voltage (`)
Size
Per Unit
XD4000 415V Drive 0.37kW(HD)/0.75kW(ND) XD4000-02P2-4C2221 S1 *
XD4000 415V Drive 0.75kW(HD)/1.50kW(ND) XD4000-04P0-4C2221 S1 *
XD4000 415V Drive 1.50kW(HD)/2.20kW(ND) XD4000-05P6-4C2221 S1 *
XD4000 415V Drive 2.20kW(HD)/3.00kW(ND) XD4000-07P2-4C2221 S1 *
XD4000 415V Drive 3.00kW(HD)/4.00kW(ND) XD4000-09P3-4C2221 S1 *
XD4000 415V Drive 4.00kW(HD)/5.50kW(ND) XD4000-12P7-4C2221 S1 *
XD4000 415V Drive 5.50kW(HD)/7.50kW(ND) XD4000-16P5-4C2221 S2 *
XD4000 415V Drive 7.50kW(HD)/11.0kW(ND) XD4000-23P5-4C2221 S2 *
XD4000 415V Drive 11.0kW(HD)/15.0kW(ND) XD4000-31P7-4C2221 S3 *
› Detachable 8 line Graphical LCD keypad XD4000 415V Drive 15.0kW(HD)/18.5kW(ND) XD4000-39P2-4C2221 S3 *
with battery for RTC & Help Menu XD4000 415V Drive 18.5kW(HD)/22.0kW(ND) XD4000-46P3-4C2221 S3 *
› Rated for -10 to 50°C ambient temperature XD4000 415V Drive 22.0kW(HD)/30.0kW(ND) XD4000-61P5-4C2221 S4 *
› Inbuilt DC Reactor over entire range XD4000 415V Drive 30.0kW(HD)/37.0kW(ND) XD4000-74P5-4C2221 S4 *
› Inbuilt EMC filter entire range for EMC Three XD4000 415V Drive 37.0kW(HD)/45.0kW(ND) XD4000-88P0-4C2221 S4 *
levels C2 / C3 Phase XD4000 415V Drive 45.0kW(HD)/55.0kW(ND) XD4000-106P-4C2221 S5 *
› Inbuilt Dual port Ethernet IP / Modbus TCP 415 VAC XD4000 415V Drive 55.0kW(HD)/75.0kW(ND) XD4000-145P-4C2221 S5 *
& Modbus RS485 ports XD4000 415V Drive 75.0kW(HD)/90.0kW(ND) XD4000-173P-4C2221 S5 *
› Inbuilt Braking transistor upto 160kW HD. XD4000 415V Drive 90.0kW(HD)/110kW(ND) XD4000-211P-4B2221 S6 *
› 8 DIs, 4 DOs, 3 AIs, 2 AOs, 2 STO inputs XD4000 415V Drive 110kW(HD)/132kW(ND) XD4000-250P-4B2221 S6 *
› Crane specific functions XD4000 415V Drive 132kW(HD)/160kW(ND) XD4000-302P-4B2221 S6 *
› Pump specific functions XD4000 415V Drive 160kW(HD)/220kW(ND) XD4000-427P-4A2221 S7A *
› Line & Output Contactor control XD4000 415V Drive 200kW(HD)/250kW(ND) XD4000-481P-4A1221 S7B *
› Load Sharing, Speed – Torque master slave XD4000 415V Drive 250kW(HD)/315kW(ND) XD4000-616P-4A1221 S7B *
› Multi-motor configuration Mode XD4000 IP55 415V Drive 0.75kW(ND) XD4000-02P2-4S2221 S1 *
› Automatic Restart XD4000 IP55 415V Drive 1.50kW(ND) XD4000-04P0-4S2221 S1 *
› Catch on the fly (Flying Start) XD4000 IP55 415V Drive 2.20kW(ND) XD4000-05P6-4S2221 S1 *
› Fault Inhibition / Error detect disabling XD4000 IP55 415V Drive 3.00kW(ND) XD4000-07P2-4S2221 S1 *
(Fire Mode) XD4000 IP55 415V Drive 4.00kW(ND) XD4000-09P3-4S2221 S1 *
› 15 nos. trip histories with date and time Stamp XD4000 IP55 415V Drive 5.50kW(ND) XD4000-12P7-4S2221 S1 *
XD4000 IP55 415V Drive 7.50kW(ND) XD4000-16P5-4S2221 S2 *
XD4000 IP55 415V Drive 11.0kW(ND) XD4000-23P5-4S2221 S2 *
Note: * For prices please contact nearest branch office
- IP55 with Inbuilt Power Disconnector
Range : 0.75kW ND to 11kW ND
› IP55 Complying to IEC 60529
› Built-In IP65 Graphical LCD Display with RTC
› Supports Asynchronous, PM synchronous & reluctance motors
› Built-in DC reactor & C2/C3 EMC filter for Harmonics & Noise reduction.
› Built-in dynamic braking unit.
› Starting Torque of 150% at 3Hz for V/f
› Built-in Brake Control & Macros
› Inbuilt PID with sleep & wake up feature
› Conformal coating complying to IEC 60721-3-3 class 3C3, 3S2 & 3M3
› Built-in RS 485 Modbus RTU & Modbus TCP/Ethernet IP communication and
optional – Profinet S2 redundancy & Profibus
Ordering Information for xD4000 AC Drive
xD 4 0 0 0 - 4 B 1
Future Use 1 : Future Use
2 : With EMC Filter
EMC Filter
1 : Without EMC Filter
DC Reactor 2 : With DC Reactor
2 : With Braking Unit
Braking Unit
1 : Without Braking Unit
IP Class A = IP00 B = IP20 C = IP21 S = IP55
Mains Voltage 4 = 3Ph, 380-480 VAC
Current Rating
Model no.
Lauritz Knudsen, 15.08.2026 118
DrivesPDF page 126 Accessories for AC Drives [8504]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Accessories for AC Drives [8504]
Description M.R.P. (`)
Drive Model Cat. No.
Per Unit
xD1000 IP54 LED Remote Keypad XDOP-DOP-100 *
IP21 LCD Std. Graphical Keypad XDOP-DOP-300 *
Remote Mounting Kit for IP21 LCD Keypad XDKT-DOP-300 *
xD2000
IP65 LCD Graphical Keypad XDOP-DOP-500 *
Mounting kit for IP65 LCD Keypad XDKT-DOP-500 *
IO Expansion Card-1 - 6DI,2DO,2AI XDIO-EX1-V01 *
IO Expansion Card-2 - 3RO XDIO-EX2-V01 *
Profibus-DP Comm. Card XDCI-PDP-V01 *
IP54 LED Remote Keypad XDOP-DOP-100 *
IP65 LCD Graphical Keypad XDOP-DOP-500 *
Mounting kit for IP65 LCD Keypad XDKT-DOP-500 *
Communication Option Module Adapter XDKT-ADP-V01 *
Speed Monitoring Card XDEN-SPD-V01 *
Modbus TCP/EtherNet IP Comm. Card XDCI-ETH-V01 *
EtherCAT Comm. Card XDCI-ECT-V01 *
xD3000 Profibus-DP Comm. Card XDCI-PDP-V01 *
DeviceNet Comm. Card XDCI-DEN-V01 *
POWERLINK Comm. Card XDCI-PLN-V01 *
ProfiNet Comm. Card XDCI-PFN-V01 *
CANopen DaisyChain Comm. Card XDCI-CND-V01 *
CANopen SUB-D Comm. Card XDCI-CNS-V01 *
CANopen Terminals Comm. Card XDCI-CNT-V01 *
Additional Safety Integrity Module XDSI-SIM-V01 *
IP65 LCD Graphical Keypad XDOP-DOP-500 *
Mounting kit for IP65 LCD Keypad XDKT-DOP-500 *
IO Expansion Card-1 - 6DI,2DO,2AI XDIO-EX1-V01 *
IO Expansion Card-2 - 3RO XDIO-EX2-V01 *
Digital Encoder Interface Card XDEN-DEI-V01 *
Analog Encoder Interface Module XDEN-AEI-V01 *
Resolver Interface Module XDEN-REI-V01 *
HTL Encoder Interface Module XDEN-HEI-V01 *
Profibus-DP Comm. Card XDCI-PDP-V01 *
xD4000 DeviceNet Comm. Card XDCI-DEN-V01 *
POWERLINK Comm. Card XDCI-PLN-V01 *
ProfiNet Comm. Card - Redundant XDCI-PFN-V02 *
CANopen DaisyChain Comm. Card XDCI-CND-V01 *
CANopen SUB-D Comm. Card XDCI-CNS-V01 *
CANopen Terminals Comm. Card XDCI-CNT-V01 *
Note:
* For prices please contact nearest branch office
Drives are covered under HS code 8504 40 90 and are charged at 18% GST.
Lauritz Knudsen, 15.08.2026 119PDF page 127 Digital Soft Starters [8504]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Digital Soft Starters [8504]
Soft Starters M.R.P.
Bypass
Range: 18A to 200A Description Cat. No. (`)
Contactor
Per Unit
xS1000,18A,M:200-440VAC,C:110/230-440VAC XS1000-0018-B44111 *
xS1000,34A,M:200-440VAC,C:110/230-440VAC XS1000-0034-B44111 *
xS1000,42A,M:200-440VAC,C:110/230-440VAC XS1000-0042-B44111 *
xS1000,48A,M:200-440VAC,C:110/230-440VAC XS1000-0048-B44111 *
xS1000,60A,M:200-440VAC,C:110/230-440VAC XS1000-0060-B44111 *
xS1000 Soft Starters : For Standard Applications xS1000,75A,M:200-440VAC,C:110/230-440VAC XS1000-0075-B44111 * Built - In
› Inbuilt Bypass Contactor xS1000,85A,M:200-440VAC,C:110/230-440VAC XS1000-0085-B44111 *
› Soft Start / Soft Stop xS1000,100A,M:200-440VAC,C110/230-440VAC
› Compact in size
XS1000-0100-B44111 *
xS1000,140A,M:200-440VAC,C110/230-440VAC XS1000-0140-B44111 *
› Truly plug & play
› Communication options available xS1000,170A,M:200-440VAC,C110/230-440VAC XS1000-0170-B44111 *
xS1000,200A,M:200-440VAC,C110/230-440VAC XS1000-0200-B44111 *
Soft Starters M.R.P.
Bypass
Range: 18A to 200A Description Cat. No. (`)
Contactor
Per Unit
xS2000,18A,M:200-440VAC,C:110/230-440VAC XS2000-0018-B44111 *
xS2000,34A,M:200-440VAC,C:110/230-440VAC XS2000-0034-B44111 *
xS2000,42A,M:200-440VAC,C:110/230-440VAC XS2000-0042-B44111 *
xS2000,48A,M:200-440VAC,C:110/230-440VAC XS2000-0048-B44111 *
xS2000,60A,M:200-440VAC,C:110/230-440VAC XS2000-0060-B44111 *
xS2000,75A,M:200-440VAC,C:110/230-440VAC XS2000-0075-B44111 *
xS2000 Soft Starters : For standard applications
xS2000,85A,M:200-440VAC,C:110/230-440VAC XS2000-0085-B44111 * Built - In
› Inbuilt Bypass Contactor
› Soft start / Soft stop / Adjustable current limit xS2000,100A,M:200-440VAC,C110/230-440VAC XS2000-0100-B44111 *
› Essential motor protections against xS2000,140A,M:200-440VAC,C110/230-440VAC XS2000-0140-B44111 *
» Overload xS2000,170A,M:200-440VAC,C110/230-440VAC XS2000-0170-B44111 *
» Single phasing xS2000,200A,M:200-440VAC,C110/230-440VAC XS2000-0200-B44111 *
» Instantaneous over current
» Phase sequence reversal
» Abnormality in supply
» Unbalanced current Note:
› Thermistor protection through PTC * For prices please contact nearest branch office
› Excess start time setting The above xS1000 & xS2000 ratings are based on 400% starting current, 10 starts per hour up to 60A & 6
› Communication options available starts per hour for 75A & above, 6 seconds starting time and ambient temperature of 40°C.
› PC Interface as optional For proper sizing of soft starter based on the application parameters please use Winstart Software.
Ordering Information for xS1000 & xS2000 Series Soft Starter
xS nnnn - 1234 - B V C D F F
We recommend the use of :
1. Line Contactor : This will isolate and protect the soft starter SCR's from
any voltage transient while it's not in operation.
xS Soft starters
2. Bypass Contactor (For models without built-in bypass) : This will
Soft starter Name
bypass and protect the soft starter SCR's while in running state from
nnnn 1000 xS1000
Current and Voltage transient's.
2000 xS2000
Current Rating 3. Semiconductor fuses : This will protect the starter SCR's during
1234
1234 Nominal Current Rating starting and stopping states from current transient's and excess I²T.
Bypass Type
B Note:
B Internal Bypass
Mains Voltage * For prices please contact nearest branch office
V 4 3Ph, 200-440VAC Soft Starters are covered under HSN code 8504 40 90 and are charged
at 18% GST.
5 3Ph, 200-575VAC
Control Voltage
C 1 24V AC/DC
4 110/230-440V AC
Graphical Display
D
1 No Graphical Display
Future Use
F
1 Future Use
Future Use
F
1 Future Use
Lauritz Knudsen, 15.08.2026 120PDF page 128 Digital Soft Starters [8504]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Digital Soft Starters [8504]
Soft Starters M.R.P.
Bypass
Description Cat. No. (`)
Range: 24A to 580A Contactor
Per Unit
xS3000,24A,M:200-525VAC,C:110/220VAC XS3000-0024-B52211 *
xS3000,42A,M:200-525VAC,C:110/220VAC XS3000-0042-B52211 *
xS3000,52A,M:200-525VAC,C:110/220VAC XS3000-0052-B52211 *
xS3000,64A,M:200-525VAC,C:110/220VAC XS3000-0064-B52211 *
xS3000,69A,M:200-525VAC,C:110/220VAC XS3000-0069-B52211 *
xS3000,105A,M:200-525VAC,C:110/220VAC XS3000-0105-B52211 *
xS3000,115A,M:200-525VAC,C:110/220VAC XS3000-0115-B52211 *
xS3000,135A,M:200-525VAC,C:110/220VAC XS3000-0135-B52211 *
› Built in bypass contactor xS3000,184A,M:200-525VAC,C:110/220VAC XS3000-0184-B52211 * Built - In
› Compact & Flexible Design
› Screw-less design for easy and fast servicing
xS3000,200A,M:200-525VAC,C:110/220VAC XS3000-0200-B52211 *
› USB port for easy and fast commissioning and xS3000,229A,M:200-525VAC,C:110/220VAC XS3000-0229-B52211 *
data extraction xS3000,250A,M:200-525VAC,C:110/220VAC XS3000-0250-B52211 *
› Full graphical display with multi-languages xS3000,352A,M:200-525VAC,C:110/220VAC XS3000-0352-B52211 *
support xS3000,397A,M:200-525VAC,C:110/220VAC XS3000-0397-B52211 *
› Built-in Simulation Mode
› 384 event logs xS3000,410A,M:200-525VAC,C:110/220VAC XS3000-0410-B52211 *
› Communication options available xS3000,550A,M:200-525VAC,C:110/220VAC XS3000-0550-B52211 *
› Fire Mode Function xS3000,580A,M:200-525VAC,C:110/220VAC XS3000-0580-B52211 *
› Starts per hour count
Soft Starters Description
M.R.P.
Bypass
Cat. No. (`)
Range: 24A to 1250A Contactor
Per Unit
xS4000,24A,M:200-525VAC,C:110/220VAC XS4000-0024-B52211 *
xS4000,42A,M:200-525VAC,C:110/220VAC XS4000-0042-B52211 *
xS4000,52A,M:200-525VAC,C:110/220VAC XS4000-0052-B52211 *
xS4000,64A,M:200-525VAC,C:110/220VAC XS4000-0064-B52211 *
xS4000,69A,M:200-525VAC,C:110/220VAC XS4000-0069-B52211 *
xS4000,105A,M:200-525VAC,C:110/220VAC XS4000-0105-B52211 *
xS4000,115A,M:200-525VAC,C:110/220VAC XS4000-0115-B52211 *
xS4000,135A,M:200-525VAC,C:110/220VAC XS4000-0135-B52211 *
xS4000,184A,M:200-525VAC,C:110/220VAC XS4000-0184-B52211 *
› Built in bypass contactor
› Compact & Flexible Design xS4000,200A,M:200-525VAC,C:110/220VAC XS4000-0200-B52211 *
› Screw-less design for easy and fast servicing xS4000,229A,M:200-525VAC,C:110/220VAC XS4000-0229-B52211 *
Built - In
› USB port for easy and fast commissioning and xS4000,250A,M:200-525VAC,C:110/220VAC XS4000-0250-B52211 *
data extraction XS4000-0352-B52211
xS4000,352A,M:200-525VAC,C:110/220VAC *
› Full graphical display with multi-languages XS4000-0397-B52211
support
xS4000,397A,M:200-525VAC,C:110/220VAC *
› Real time graphs of motor operating xS4000,410A,M:200-525VAC,C:110/220VAC XS4000-0410-B52211 *
performance xS4000,550A,M:200-525VAC,C:110/220VAC XS4000-0550-B52211 *
› 384 event logs with time stamping xS4000,580A,M:200-525VAC,C:110/220VAC XS4000-0580-B52211 *
› Advanced protection system xS4000,835A,M:200-525VAC,C:110/220VAC XS4000-0835-B52211 *
› Communication options available xS4000,940A,M:200-525VAC,C:110/220VAC XS4000-0940-B52211 *
› Smart card for level controlled pump activation
and pump protection xS4000,1070A,M:200-525VAC,C:110/220VAC XS4000-1070-B52211 *
› Under Voltage / Over Voltage protection xS4000,1230A,M:200-525VAC,C:110/220VAC XS4000-1230-B52211 *
available xS4000,1250A,M:200-525VAC,C:110/220VAC XS4000-1250-B52211 *
› Fire Mode Function xS4000,735A,M:200-525VAC,C:110/220VAC XS4000-0735-C52211 * External bypass
› Starts per hour count xS4000,830A,M:200-525VAC,C:110/220VAC XS4000-0830-C52211 * contactor
(AC1 rating)
› Power through function available
xS4000,1025A,M:200-525VAC,C:110/220VAC XS4000-1025-C52211 * All protections
› Scheduling based on RTC remain active
xS4000,1170A,M:200-525VAC,C:110/220VAC XS4000-1170-C52211 * during bypass
operation
xS4000,1220A,M:200-525VAC,C:110/220VAC XS4000-1220-C52211 *
Note:
xS nnnn - 1234 - B V C D F F * For prices please contact nearest branch office
Prices for 1000V and External Bypass soft starter below 735A available on
xS Soft starters Control Voltage request Soft Starters are covered under HSN code 8504 40 90 and are charged at
Soft starter Name C 1 24V AC/DC 18% GST.
nnnn 3000 xS3000 2 110-120/220-240V AC
4000 xS4000 Graphical Display We recommend the use of :
D
Current Rating 2 Fixed Graphical Display
1234 1. Line Contactor : This will isolate and protect the soft starter SCR's from any
1234 Nominal Current Rating Future Use
F voltage transient while it's not in operation.
Bypass Type 1 Future Use
B B Internal Bypass
2. Semiconductor fuses : This will protect the starter SCR's during starting and
Future Use
C Continuous / External Bypass
F stopping states from current transient's and excess I2T.
1 Future Use
Mains Voltage 3. Bypass Contactor (For models without built-in bypass) : This will bypass and
5 3Ph, 200-525VAC protect the soft starter SCR's while in running state from Current and Voltage
V transient's.
6 3Ph, 380-600VAC
7 3Ph, 380-690VAC
Lauritz Knudsen, 15.08.2026 121PDF page 129 Digital Soft Starters [8504]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Digital Soft Starters [8504]
Optional Modules/Cards for xS Series
M.R.P.
Description Cat. No. (`)
Per Unit
xS1000 & xS2000 Modbus RTU Card XSCI-RTU-121 *
xS1000 & xS2000 Modbus TCP Card XSCI-TCP-123 *
xS1000 & xS2000 Profibus Card XSCI-PDP-121 *
xS1000 & xS2000 Profinet Card XSCI-PFN-122 *
xS1000 & xS2000 Ethernet Card XSCI-ETH-122 *
xS1000 & xS2000 DeviceNet Card XSCI-DEN-121 *
xS1000 & xS2000 USB Interface Card XSCI-USB-121 *
xS1000 & xS2000 Operator interface Card XSOP-DOC-100 *
xS1000 & xS2000 Digital Operator Kit XSOP-DOK-100 *
xS3000 and xS4000 Modbus RTU Card XSCI-RTU-341 *
xS3000 and xS4000 Modbus RTU + GF Card XSCI-RTU-342 *
xS3000 and xS4000 Modbus TCP + GF Card XSCI-TCP-343 *
xS3000 and xS4000 Profibus Card XSCI-PDP-341 *
xS3000 and xS4000 Profinet + GF Card XSCI-PFN-343 *
xS3000 and xS4000 Ethernet + GF Card XSCI-ETH-343 *
xS3000 and xS4000 DeviceNet Card XSCI-DEN-341 *
xS3000 and xS4000 Operator & Cable XSOP-DOP-200 *
xS3000 and xS4000 Operator Interface Card XSOP-DOC-200 *
xS3000 and xS4000 Digital Operator Kit XSOP-DOK-200 *
xS3000 and xS4000 Pumping Smart Card XSSC-PSC-341 *
Note:
* For prices please contact nearest branch office
Soft Starters are covered under HSN code 8504 40 90 and are charged
at 18% GST.
Lauritz Knudsen, 15.08.2026 122PDF page 130 V0 C0 I0 V1 C1 I1 C0 0 1 2 3 C1 4 5 6 7
Extracted reference text; use the original PDF to check column alignment, variants and price units.
V0 C0 I0 V1 C1 I1 C0 0 1 2 3 C1 4 5 6 7 + - C0 0 1 2 3 C1 4 5 6 7
ANALOG INPUT (CH0) ANALOG OUTPUT
INPUT 8 x 24 VDC 24 VDC INPUT 8 x 24 VDC
2 x (0-10 V) / (4-20mA) 2 x (0-10 V) / (4-20mA)
GND
D -
0 1 2 3 D+
CH0 CH1 CH0 CH1
IN COM 2
IN V I V I 4 5 6 7 OUT V I V I IN 0 1 2 3 4 5 6 7
RS232/
RUN / STOP RUN / STOP RUN / STOP RUN / STOP
RS485
COM 1
0 1 2 3 OUT 0 1 2 3 4 5 6 7
OUT
PC
xP1000 4 5 6 7
xP1000 xP1000 USB
xP1000
ANALOG INPUT (CH1) OUTPUT 8 x RELAY / 5A (CHO) (CH1) RUN STOP OUTPUT
2 x (0-10 V) / (4-20mA) 8 x RELAY / 5A
V2 C2 I2 V3 C3 I3 C2 0 1 2 3 C3 4 5 6 7 V0 C0 I0 V1 C1 I1 C2 0 1 2 3 C3 4 5 6 7
xP1000 PLC Features:
Main CPU Expansion Modules:
› 8 Digital Inputs Digital I/Os
› 24 V DC Power Supply › Extension with 8 Digital Inputs and 8 Relay Outputs,
› 8 Digital Outputs (Relay Output) 5 A (Res.) @ 230 VAC / 30 VDC Relay Load 5 A (Res.) @ 230 VAC / 30 VDC
› 2 Serial Communication Ports › 24 V DC Power Supply
(COM1 - RS232/RS485, COM2 - RS485)
› 256KB User Program Memory, 8KB User Data Memory. Analog Inputs
› Operating Temperature : 0°C to 55°C, › Extension with 4 Analog Inputs (0-10V / 4-20mA)
Storage Temperature: - 40°C to 70°C › 24 V DC Power Supply
Analog Outputs
› Extension with 2 Analog Outputs (0-10V / 4-20mA)
› 24 V DC Power Supply
4.3 inch 7 inch 10.1 inch
xT1000 HMI Features: xT1000
› HMI Size › Password Management
4.3”, 7” & 10.1” with colour TFT display options with & User access levels & application password management
without Ethernet model › Safety Standards
› Touch Screen CE, RoHS Compliant, IP 65 protection for front panel
Higher brightness level up to 440 cd/m2 & long backlight life with Class 2 Pollution Degree.
up to 50000 hours for display › Memory
› Protection ROM - 32 MB for Serial models & 64 MB for with Ethernet
Shock & Vibration protection as per IEC Standard model, ROM Expandable up to 4 GB via USB Stick/SD card
xT1000
› CPU › Picture Library
Equipped with powerful CPU Cortex-M7 (600MHz) Inbuilt picture library with high resolution images
› Data Logging
Equipped with powerful CPU Cortex-M7 (600MHz)
› Operating Temperature
Operation temperature range: 0 to 50 °C
› Memory
RAM - 32 MB for all Models
Lauritz Knudsen, 15.08.2026 123PDF page 131 Programmable Logic Controller (PLC) [8537/8538]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Programmable Logic Controller (PLC) [8537/8538]
xP5000 Series Category Description Cat. No.
M.R.P.
(`)
Per Unit
xP1000 xP1000 CPU, 8 Dl,8 RO, 2 Serial Port. xP1000-MM1DR16AA11 *
Expansion 8 Dl/ 8 RO xPEXPN-ME4DR16AA11 *
xP1000
Expansions Expansion 4 AI xPEXPN-ME2AX04AA11 *
Extension with 2 Analog Outputs xPEXPN-ME3AY02AA11 *
xP3000, CPU, AC220, 09DI, 07DO RY xP3000-M1DR16AA111 *
xP3000, CPU, AC220, 14DI, 10DO RY xP3000-M1DR24AA111 *
xP3000
xP3000 CPU AC220 20DI 12DO RY xP3000-M1DR32AA111 *
xP3000, CPU, AC220, 24DI, 16DO RY xP3000-M1DR40AA111 *
xP5000 CPU DC24 09DI 07DO TP xP5000-M1DT16AA111 *
xP5000 CPU DC24 09DI 07DO TN xP5000-M1DU16AA111 *
xP5000 CPU AC220 09DI 07DO RY xP5000-M1DR16AA111 *
› AC / DC power supply xP5000 CPU DC24 14DI 10DO TN xP5000-M1DU24AA111 *
› Supports Upto 196 IOs, Relay and transistor outputs xP5000 CPU DC24 14DI 10DO TP xP5000-M1DT24AA111 *
› Flexible I/Os, 2 cartridges, and up to 4 expansions xP5000 CPU AC220 14DI 10DO RY xP5000-M1DR24AA111 *
› Ethernet and Serial line ports xP5000 CPU DC24 14DI 10DO TP Eth. xP5000-M1DT24EA111 *
› Micro-SD card slot and USB port xP5000, CPU, DC24, 14DI, 10DO TN Eth. xP5000-M1DU24EA111 *
› 2 High speed counters, 2@100KHz xP5000 CPU AC220 14DI 10DO RY Eth xP5000-M1DR24EA111 *
› 2 Pulse Outputs at 100kHz*2 xP5000 xP5000, CPU, DC24, 20DI, 12DO TN xP5000-M1DU32AA111 *
xP5000 CPU DC24 20DI12DO TP xP5000-M1DT32AA111 *
xP5000 CPU AC220 18DI 14DO RY xP5000-M1DR32AA111 *
CPU xP5000 CPU AC220 18DI 14DO RY Eth. xP5000-M1DR32EA111 *
xP5000,CPU, DC24, 24DI, 16DO TN xP5000-M1DU40AA111 *
xP5000 CPU DC24 24DI 16DO TP xP5000-M1DT40AA111 *
xP5000, CPU, AC220, 24DI, 16DO RY, xP5000-M1DR40AA111 *
xP5000 CPU DC24 24DI 16DO TP Eth. xP5000-M1DT40EA111 *
xP5000, CPU, DC24, 24DI, 16DO TN, Eth. xP5000-M1DU40EA111 *
xP5000 CPU AC220 24DI 16DO RY Eth xP5000-M1DR40EA111 *
xP5000 CPU AC220 36DI 24DO RY xP5000-M1DR60AA111 *
xP5000, CPU, AC220, 36DI, 24DO RY, 1 Eth xP5000-M1DR60EA111 *
xPEXPN, 8 OUT RY xPEXPN-XLE3DR08AA1 *
xP5000 Expansion Modules xPEXPN, 8DC inputs ,8 relay outputs xPEXPN-XLE4DR16AA1 *
xPEXPN, 16 INPUTS xPEXPN-XLE2DX16AA1 *
› Digital Input Modules: 16 / 32 channel options xPEXPN, 16 OUT TR.NPN xPEXPN-XLE3DU16AA1 *
› Digital Output Modules: 8/16 / 32 channel options
xPEXPN, 16 OUT RY xPEXPN-XLE3DR16AA1 *
› Analog Input Modules: 8 channels
›› Voltage: 0–10 V xP5000
xPEXPN, 16 OUT TR.PNP xPEXPN-XLE3DT16AA1 *
›› Current: 4–20 mA Expansion xPEXPN, 16DC inputs ,16 relay outputs xPEXPN-XLE4DR32AA1 *
Modules
› Analog Output Modules: 4/8 channels xPEXPN, 32 INPUTS xPEXPN-XLE2DX32AA1 *
›› Voltage: 0–10 V xPEXPN, 32 OUT TR.PNP xPEXPN-XLE3DT32AA1 *
›› Current: 4–20 mA xPEXPN, 32 OUT TR.NPN xPEXPN-XLE3DU32AA1 *
› Mixed I/O Modules: Combined analog input and xPEXPN, 8 ANALOG INPUTS xPEXPN-XLE2AI08AA1 *
output channels (e.g., 4 AI + 2 AO). xPEXPN, 4 ANALOG OUTPUTS xPEXPN-XLE3XQ04AA1 *
xPEXPN, 4 AI 2 AO xPEXPN-XLE4AQ06AA1 *
Note: * For prices please contact nearest branch office xPCTRG, 1 isolated serial line RS485 xPCTRG-XLO5CS01AB1 *
xPCTRG, 2 analog input ,1 analog output xPCTRG-XLO4AH03AA1 *
xP6000 Series M.R.P.
Category Description Cat. No. (`)
Per Unit
xP6000 Perf. Blind 18 I/Os, Eth, 2 RS485 xP6000M1DR18BA2E1 *
xP6000 Perf. Display 18 I/Os, Eth, 2 RS485 xP6000M1DR18DA2E1 *
xP6000
xP6000 Perf. Blind 28 I/Os, Eth, 2 MB xP6000M1DR28BA0E1 *
xP6000 Perf Blind 28 I/O Eth 2 RS485 Isol xP6000M1DR28BA2E1 *
xP6000 PLC
with display
xP6000
without display xP6100 PLC
Expansion
Module
xP6000 Perf Display 28 I/O Eth 2RS485 Isol xP6000M1DR28DA2E1 *
xP6000 Perf Display 42 I/O Eth 2RS485 Isol xP6000M1DR42DA2E1 *
› HVAC & Refrigeration Dedicated PLC xP6100
CPU xP6000 Perf Blind 42 I/O Eth, 2 RS485 Isol xP6000M1DR42BA2E1 *
› Ethernet & Serial Communication xP6100 Opt. Blind 22 I/Os, 2 RS485 xP6100M1DR22BA2E0 *
› BACnet, Modbus & CANopen Support xP6100 Opt. Display 22 I/Os, 2 RS485 xP6100M1DR22DA2E0 *
› Scalable I/O Architecture
xP6000 Expansion Module 14I/O xPEXPNXLE7DR42AA1 *
› Advanced PID Control Expansion
› BMS & SCADA Connectivity xP6000 Expansion Module 28I/O xPEXPNXLE7DR102A1 *
› Remote Monitoring & Diagnostics xP6000 Gateway Secure Interface xGWS00GW *
Gateway
› High Reliability & Energy Efficiency xP6000 PlugIn Secure Interface xGWS00PI *
› Compact, Modular & OEM-Friendly Design
Lauritz Knudsen, 15.08.2026 124PDF page 132 Human Machine Interface (HMI) [8537]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Human Machine Interface (HMI) [8537]
xT Series M.R.P.
Category Description Cat. No. (`)
Per Unit
› Wide Range upto 15” in size
› Application Memory: FLASH EPROM / xT1000 series, 4" TFT, Serial,2 Port xT1000-E104SDAAA1 *
Screen area: 64MB/User font area 8 xT1000 series, 4" TFT, Serial,2 Port, 1 Eth Port xT1000-E104EDAAA1 *
MB / Logic program area: 132KB xT1000 series, 7" TFT, Serial,2 Port xT1000-E107SDAAA1 *
xT1000
› Backup Memory: Screen Area: SRAM xT1000 series, 7" TFT, Serial,2 Port, 1 Eth Port xT1000-E107EDAAA1 *
320KB,Variable Area: SRAM 64KB *
xT1000 series, 10" TFT, Serial,2 Port xT1000-E110SDAAA1
› Various Communication Interface:
xT1000 series, 10" TFT, Serial,2 Port, 1 Eth Port xT1000-E110EDAAA1 *
Ethernet /RS-232C / RS-422/485
› USB host and device xTE6000 Series 7 " HMI, DC 24V, Eth. xTE6000-07EDAA1 *
› SD memory card interface xTE6000 Series 10 " HMI, DC 24V, Eth. xTE6000-10EDAA1 *
HMI xTE6000
› Certificates: CE, RoHS xTE6000 Series 12 " HMI, DC 24V, Eth. xTE6000-12EDAA1 *
xTE6000 Series 15 " HMI, DC 24V, Eth. xTE6000-15EDAA1 *
xTS6000 Series 04” Advance HMI, DC 24V, Eth. xTS6000-04EDAA1 *
xTS6000 Series 07” Advance HMI, DC 24V, Eth. xTS6000-07EDAA1 *
xTS6000 xTS6000 Series 10” Advance HMI, DC 24V, Eth. xTS6000-10EDAA1 *
xTS6000 Series 12” Advance HMI, DC 24V, Eth. xTS6000-12EDAA1 *
xTS6000 Series 15” Advance HMI, DC 24V, Eth. xTS6000-15EDAA1 *
Note: * For prices please contact nearest branch office
xTE6000_10inch xTE6000_15inch xTS6000_15inch
xTE6000 xTS6000
› Wide TFT Color Display (16 Million Colors) › Wide TFT Color LCD Display (16 Million Colors)
› Resistive Touch Panel › Projected Capacitive Multi-Touch Panel
› 24V DC Power Supply › High-Performance CPU for Faster Screen Processing
› Compatible with GP-Pro EX Software › Dual Ethernet Ports (on selected models)
› Panel Mount Design › 24V DC Power Supply
› Industrial Grade Construction › Compatible with GP-Pro EX Software
› Panel Mount Design
› Industrial Grade Construction (IP65 Front Protection)
Lauritz Knudsen, 15.08.2026 125PDF page 133 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 134 Miniature Circuit Breaker (MCB) [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Miniature Circuit Breaker (MCB) [8536]
Range Highlights
› True contact indication for individual pole › Available in B, C & D curves
› Label holder facility for all configurations › Low watt loss - almost 50% of the values prescribed by IS/IEC 60898
› Conforms to IS/IEC 60898 - 10kA › Trip free mechanism
› Conforms to IS/IEC 60947 - 2 › Design based on advanced current limiting hammer trip mechanism
» 15kA C-curve till 40 A › No Line-Load bias
» 10kA C-curve for 50A, 63A › Bi connect feature on both sides
› Suitable for accessory fitment
Modules
Rating B-Curve M.R.P. (`) C-Curve M.R.P. (`) D-Curve M.R.P. (`)
1 Mod =
Cat. No. Per Unit Cat. No. Per Unit Cat. No. Per Unit
17.5 mm
Single Pole (SP)
0.5A 1 - - BB10E50C 640 BB10E50D 665
1A 1 - - BB10010C 640 BB10010D 665
2A 1 - - BB10020C 640 BB10020D 665
3A 1 - - BB10030C 640 BB10030D 665
4A 1 - - BB10040C 640 BB10040D 665
6A 1 BB10060B 377 BB10060C 377 BB10060D 545
10A 1 BB10100B 377 BB10100C 377 BB10100D 545
16A 1 BB10160B 377 BB10160C 377 BB10160D 545
20A 1 BB10200B 377 BB10200C 377 BB10200D 545
25A 1 BB10250B 377 BB10250C 377 BB10250D 545
32A 1 BB10320B 377 BB10320C 377 BB10320D 545
40A 1 BB10400B 940 BB10400C 940 BB10400D 960
50A 1 BB10500B 940 BB10500C 940 BB10500D* 960
63A 1 BB10630B 940 BB10630C 940 BB10630D* 960
Double Pole (DP)
0.5A 2 - - BB20E50C 1870 BB20E50D 1905
1A 2 - - BB20010C 1870 BB20010D 1905
2A 2 - - BB20020C 1870 BB20020D 1905
3A 2 - - BB20030C 1870 BB20030D 1905
4A 2 - - BB20040C 1870 BB20040D 1905
6A 2 BB20060B 1305 BB20060C 1305 BB20060D 1385
10A 2 BB20100B 1305 BB20100C 1305 BB20100D 1385
16A 2 BB20160B 1305 BB20160C 1305 BB20160D 1385
20A 2 BB20200B 1305 BB20200C 1305 BB20200D 1385
25A 2 BB20250B 1305 BB20250C 1305 BB20250D 1385
32A 2 BB20320B 1305 BB20320C 1305 BB20320D 1385
40A 2 BB20400B 2125 BB20400C 2125 BB20400D 2260
50A 2 BB20500B 2125 BB20500C 2125 BB20500D* 2260
63A 2 BB20630B 2125 BB20630C 2125 BB20630D* 2260
Three Pole (TP)
0.5A 3 - - BB30E50C 2725 BB30E50D 2765
1A 3 - - BB30010C 2725 BB30010D 2765
2A 3 - - BB30020C 2725 BB30020D 2765
3A 3 - - BB30030C 2725 BB30030D 2765
4A 3 - - BB30040C 2725 BB30040D 2765
6A 3 BB30060B 2055 BB30060C 2055 BB30060D 2205
10A 3 BB30100B 2055 BB30100C 2055 BB30100D 2205
16A 3 BB30160B 2055 BB30160C 2055 BB30160D 2205
20A 3 BB30200B 2055 BB30200C 2055 BB30200D 2205
25A 3 BB30250B 2055 BB30250C 2055 BB30250D 2205
32A 3 BB30320B 2055 BB30320C 2055 BB30320D 2205
40A 3 BB30400B 3200 BB30400C 3200 BB30400D 3415
50A 3 BB30500B 3200 BB30500C 3200 BB30500D* 3415
63A 3 BB30630B 3200 BB30630C 3200 BB30630D* 3415
Note: Standard Pack Quantity for MCB : SP - 12 Nos., DP - 6 Nos., TP - 4 Nos., FP - 3 Nos.
*For details, please contact nearest branch office
Lauritz Knudsen, 15.08.2026 127PDF page 135 Miniature Circuit Breaker (MCB) [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Miniature Circuit Breaker (MCB) [8536]
Modules
Rating B-Curve M.R.P. (`) C-Curve M.R.P. (`) D-Curve M.R.P. (`)
1 Mod =
Cat. No. Per Unit Cat. No. Per Unit Cat. No. Per Unit
17.5 mm
Four Pole (FP)
0.5A 4 - - BB40E50C 3460 BB40E50D 3465
1A 4 - - BB40010C 3460 BB40010D 3465
2A 4 - - BB40020C 3460 BB40020D 3465
3A 4 - - BB40030C 3460 BB40030D 3465
4A 4 - - BB40040C 3460 BB40040D 3465
6A 4 BB40060B 2875 BB40060C 2875 BB40060D 3000
10A 4 BB40100B 2875 BB40100C 2875 BB40100D 3000
16A 4 BB40160B 2875 BB40160C 2875 BB40160D 3000
20A 4 BB40200B 2875 BB40200C 2875 BB40200D 3000
25A 4 BB40250B 2875 BB40250C 2875 BB40250D 3000
32A 4 BB40320B 2875 BB40320C 2875 BB40320D 3000
40A 4 BB40400B 4030 BB40400C 4030 BB40400D 4435
50A 4 BB40500B 4030 BB40500C 4030 BB40500D* 4435
63A 4 BB40630B 4030 BB40630C 4030 BB40630D* 4435
Note: Standard Pack Quantity for MCB : SP - 12 Nos., DP - 6 Nos., TP - 4 Nos., FP - 3 Nos.
*For details, please contact nearest branch office
MCBs (Miniature Circuit Breakers) : 80A-125A [8536]
Range Highlights
› Short circuit Breaking Capacity - 15kA (IS/IEC 60947-2, EN 60947-2) › Suitable for Isolation
› C & D Characteristics › Protection Degree - IP 20
› Available in SP, DP, TP and FP › Availability of wide Range of Site Mountable Accessories
Modules C Curve M.R.P. (`) D Curve M.R.P. (`)
Rating 1 Mod = 17.5 mm Cat. No. Per Unit Cat. No. Per Unit
Single Pole (SP)
80A 1.5 AU15S10803C 3980 AU15S10803D 4530
100A 1.5 AU15S11003C 4460 AU15S11003D 5065
125A 1.5 AU15S11253C 4800 AU15S11253D 5475
Double Pole (DP)
80A 3 AU15S20803C 8815 AU15S20803D 10035
100A 3 AU15S21003C 9400 AU15S21003D 10690
125A 3 AU15S21253C 10345 AU15S21253D 11760
Three Pole (TP)
80A 4.5 AU15S30803C 13905 AU15S30803D 15835
100A 4.5 AU15S31003C 14835 AU15S31003D 16860
125A 4.5 AU15S31253C 16460 AU15S31253D 18705
Four Pole (FP)
80A 6 AU15S40803C 18165 AU15S40803D 20630
100A 6 AU15S41003C 18895 AU15S41003D 21495
125A 6 AU15S41253C 21400 AU15S41253D 24320
BIS-Certified HR MCBs Range - 80A, 100A & 125A
Lauritz Knudsen, 15.08.2026 128PDF page 136 Solar Combo MCBs [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Solar Combo MCBs [8536]
(AC MCB + DC MCB)
+
AC MCB^ with C-Curve
Modules M.R.P. (`)
Description Cat. No.
1 Mod = 17.5mm Per Unit
1 AC 16A DP MCB^ + 1 DC 16A DP 500V MCB 2+2 SC221616 2015
New 1 AC 20A DP MCB^ + 1 DC 20A DP 500V MCB 2+2 SC222020 2015
New 1 AC 20A DP MCB^ + 1 DC 25A DP 500V MCB 2+2 SC222025 2015
New 1 AC 20A DP MCB^ + 1 DC 32A DP 500V MCB 2+2 SC222032 2015
1 AC 25A DP MCB^ + 1 DC 16A DP 500V MCB 2+2 SC222516 2015
New 1 AC 25A DP MCB^ + 1 DC 25A DP 500V MCB 2+2 SC222525 2015
1 AC 32A DP MCB^ + 1 DC 16A DP 500V MCB 2+2 SC223216 2015
New 1 AC 32A DP MCB^ + 1 DC 25A DP 500V MCB 2+2 SC223225 2015
1 AC 32A DP MCB^ + 1 DC 32A DP 500V MCB 2+2 SC223232 2015
Double the Protection,
Twice the Power!
Complete Protection for
Solar Rooftop Installations
DC MCB:
10kA as per IEC 60947-2
+
AC MCB:
10kA as per IS/IEC 60898-1
Lauritz Knudsen, 15.08.2026 129PDF page 137 Miniature Circuit Breaker (MCB) [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Miniature Circuit Breaker (MCB) [8536]
DC MCBs as per IEC 60947-2 [8536] Rated Voltage:
Breaking capacity of BJ Series DC MCBs
Rated Voltage:
Breaking capacity of 6 kA - BB Series DC MCBs » 10kA till 40 A
» 6kA for 50A, 63A
130V DC SP MCB 250V DC SP MCB
Modules Modules
Rating M.R.P. (`) Rating M.R.P. (`)
1 Mod = Cat. No. 1 Mod = Cat. No.
Per Unit Per Unit
17.5mm 17.5mm
Single Pole (SP) Single Pole (SP)
0.5A 1 BB10E5DC 910 0.5A 1 BJ10E5DC 1070
1A 1 BB1001DC 910 1A 1 BJ1001DC 1070
2A 1 BB1002DC 910 2A 1 BJ1002DC 1070
3A 1 BB1003DC 910 3A 1 BJ1003DC 1070
4A 1 BB1004DC 910 4A 1 BJ1004DC 1070
6A 1 BB1006DC 790 6A 1 BJ1006DC 875
10A 1 BB1010DC 790 10A 1 BJ1010DC 875
16A 1 BB1016DC 790 16A 1 BJ1016DC 875
20A 1 BB1020DC 790 20A 1 BJ1020DC 875
25A 1 BB1025DC 790 25A 1 BJ1025DC 875
32A 1 BB1032DC 790 32A 1 BJ1032DC 875
40A 1 BB1040DC 1040 40A 1 BJ1040DC 1210
50A 1 BB1050DC 1040 50A 1 BJ1050DC 1210
63A 1 BB1063DC 1040 New 63A 1 BJ1063DC 1210
250V DC DP MCB 500V DC DP MCB
0.5A 2 BB20E5DC 1950 0.5A 2 BJ20E5DC 2230
1A 2 BB2001DC 1950 1A 2 BJ2001DC 2230
2A 2 BB2002DC 1950 2A 2 BJ2002DC 2230
3A 2 BB2003DC 1950 3A 2 BJ2003DC 2230
4A 2 BB2004DC 1950 4A 2 BJ2004DC 2230
6A 2 BB2006DC 1715 6A 2 BJ2006DC 1885
10A 2 BB2010DC 1715 10A 2 BJ2010DC 1885
16A 2 BB2016DC 1715 16A 2 BJ2016DC 1885
20A 2 BB2020DC 1715 20A 2 BJ2020DC 1885
25A 2 BB2025DC 1715 25A 2 BJ2025DC 1885
32A 2 BB2032DC 1715 32A 2 BJ2032DC 1885
40A 2 BB2040DC 2320 40A 2 BJ2040DC 2400
50A 2 BB2050DC 2320 50A 2 BJ2050DC 2400
63A 2 BB2063DC 2320 New 63A 2 BJ2063DC 2400
Note: Standard Pack Quantity for MCB : SP - 12 Nos., DP - 6 Nos.
1000V DC MCBs [8536]
Rated Voltage:1000V DC
with breaking capacity of 6 kA - BK Series DC MCBs
New Modules
Cat. No. M.R.P. (`)
Description 1 Mod = 17.5mm Per Unit
DP 6A 1000V DC 6kA MCB 4 BK2006DC 2875
DP 10A 1000V DC 6kA MCB 4 BK2010DC 2875
DP 16A 1000V DC 6kA MCB 4 BK2016DC 2875
DP 20A 1000V DC 6kA MCB 4 BK2020DC 2875
DP 25A 1000V DC 6kA MCB 4 BK2025DC 2875
DP 32A 1000V DC 6kA MCB 4 BK2032DC 2875
DP 40A 1000V DC 6kA MCB 4 BK2040DC 3495
DP 50A 1000V DC 6kA MCB 4 BK2050DC 3495
DP 63A 1000V DC 6kA MCB 4 BK2063DC 3495
Lauritz Knudsen, 15.08.2026 130PDF page 138 Isolators [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Isolators [8536]
Range Highlights
› Conforms to IEC 60947-3
› Utilization category AC-22A
› Available in DP, TP and FP versions in 40A, 63A, 80A & 100A ratings
M.R.P. M.R.P. M.R.P.
Rating Modules Modules Modules
Cat. No. (`) Cat. No. (`) Cat. No. (`)
1 Mod = 17.5 mm 1 Mod = 17.5 mm 1 Mod = 17.5 mm
Per Unit Per Unit Per Unit
Double Pole (DP) Three Pole (TP) Four Pole (FP)
40A 2 BF204000 915 3 BF304000 1585 4 BF404000 2030
63A 2 BF206300 1160 3 BF306300 1825 4 BF406300 2125
80A 2 BF208000 1480 3 BF308000 2000 4 BF408000 2375
100A 2 BF210000 1550 3 BF310000 2135 4 BF410000 2570
Note: Standard Pack Quantity for Isolator : DP - 6 Nos., TP - 4 Nos., FP - 3 Nos.
RCCB (Residual Current Circuit Breaker ) [8536]
Range Highlights
› Conforms to IS 12640 (Part 1) / IEC 61008-1 › Truly current operated - operation even at nominal
› RCCBs are available in DP and FP versions from 25 to 100A Voltage
ratings with 30 mA, 100 mA and 300mA sensitivity › Operates on Core Balance Current Transformer (CBCT)
principle
› Advanced neutral mechanism
Rating Sensitivity Modules M.R.P. (`) Rating Sensitivity Modules M.R.P. (`)
Cat. No. Cat. No.
1 Mod =17.5 mm Per Unit 1 Mod =17.5 mm Per Unit
Double Pole (DP) Four Pole (FP)
30 mA 2 BG202503 4180 30 mA 4 BG402503 5860
25A 100 mA 2 BG202510 4685 25A 100 mA 4 BG402510 6135
300 mA 2 BG202530 4685 300 mA 4 BG402530 6135
30 mA 2 BG203203 4780 30 mA 4 BG403203 5920
New 32A 100 mA 2 BG203210 5355 New 32A 100 mA 4 BG403210 6240
300 mA 2 BG203230 5355 300 mA 4 BG403230 6240
30 mA 2 BG204003 4780 30 mA 4 BG404003 5920
40A 100 mA 2 BG204010 5355 40A 100 mA 4 BG404010 6240
300 mA 2 BG204030 5355 300 mA 4 BG404030 6240
30 mA 2 BG206303 5960 30 mA 4 BG406303 6690
63A 100 mA 2 BG206310 6455 63A 100 mA 4 BG406310 7155
300 mA 2 BG206330 6455 300 mA 4 BG406330 7155
30 mA 2 BG210003 10705 30 mA 4 BG410003 11665
100A 100 mA 2 BG210010 11245 100A 100 mA 4 BG410010 12095
300 mA 2 BG210030 11245 300 mA 4 BG410030 12095
RCCBs (Residual Current Circuit Breakers) : Type-Adi (with Added immunity) [8536]
Range Highlights
› Wide Range of Current Ratings - 25A to 100A
› Precise Sensitivities for variety of applications - from 30mA to 300mA
› 2P & 4P versions
› Suitable for Isolation
› Protection Degree - IP 20
› Availability of wide Range of Site Mountable Accessories
› Type Adi: Suitable for AC + Pulsating DC (Type A) + Harmonics
Modules M.R.P. (`) Rating Sensitivity Modules M.R.P. (`)
Rating Sensitivity CAT Nos. CAT Nos.
1 Mod = 1 Mod = 17.5 mm Per Unit
17.5 mm Per Unit
4P Adi
2P Adi
30mA 4 AURAD402503 9605
30mA 2 AURAD202503 7945
25A 100mA 4 AURAD402510 9785
25A 100mA 2 AURAD202510 8310
300mA 4 AURAD402530 9785
300mA 2 AURAD202530 8310
30mA 4 AURAD404003 9975
30mA 2 AURAD204003 8430
40A 100mA 4 AURAD404010 10130
40A 100mA 2 AURAD204010 8565
300mA 4 AURAD404030 10130
300mA 2 AURAD204030 8565
30mA 4 AURAD406303 10860
30mA 2 AURAD206303 9860
63A 100mA 4 AURAD406310 11085
63A 100mA 2 AURAD206310 10050
300mA 4 AURAD406330 11085
300mA 2 AURAD206330 10050
30mA 4 AURAD410003 17300
100A 30mA 2 AURAD210003 14570 100A
300mA 4 AURAD410030 17300
Lauritz Knudsen, 15.08.2026 131PDF page 139 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 140 RCBOs (Residual Current Breaker with Overcurrent Protection) [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
RCBOs (Residual Current Breaker with Overcurrent Protection) [8536]
Range Highlights*
› Conforms to IEC 61009-1, IS 12640-2, EN 61009-1 › Availability of wide Range of
› Short circuit Breaking Capacity - 10kA Site Mountable Accessories
› Precise Sensitivities for a variety of applications › Available in
» from 10mA to 300mA » Type AC: For standard AC installations
› Suitable for Isolation » Type Adi: Suitable for AC +
Pulsating DC (Type A) + Harmonics
Type-AC Type-Adi
Modules M.R.P. (`) Rating Sensitivity Modules M.R.P. (`)
Rating Sensitivity CAT Nos. CAT Nos.
1 Mod = 17.5 mm Per Unit 1 Mod = 17.5 mm Per Unit
2P AC# 2P Adi
10mA 2 AUF3C200601 7115 30mA 2 AUF3D200603 9600
30mA 2 AUF3C200603 7115 6A 100mA 2 AUF3D200610 10575
6A
100mA 2 AUF3C200610 7260 300mA 2 AUF3D200630 10970
300mA 2 AUF3C200630 7345 30mA 2 AUF3D201003 9600
10mA 2 AUF3C201001 7115 10A 100mA 2 AUF3D201010 10575
30mA 2 AUF3C201003 7115 300mA 2 AUF3D201030 10970
10A
100mA 2 AUF3C201010 7260 30mA 2 AUF3D201603 9600
300mA 2 AUF3C201030 7345 16A 100mA 2 AUF3D201610 10575
10mA 2 AUF3C201601 7115 300mA 2 AUF3D201630 10970
30mA 2 AUF3C201603 7115 30mA 2 AUF3D202003 9600
16A
100mA 2 AUF3C201610 7260 20A 100mA 2 AUF3D202010 10575
300mA 2 AUF3C201630 7345 300mA 2 AUF3D202030 10970
30mA 2 AUF3C202003 7115 30mA 2 AUF3D202503 9600
20A 100mA 2 AUF3C202010 7260 25A 100mA 2 AUF3D202510 10575
300mA 2 AUF3C202030 7345 300mA 2 AUF3D202530 10970
30mA 2 AUF3C202503 7115 30mA 2 AUF3D203203 9600
25A 100mA 2 AUF3C202510 7260 32A 100mA 2 AUF3D203210 10575
300mA 2 AUF3C202530 7345 300mA 2 AUF3D203230 10970
30mA 2 AUF3C203203 7115 30mA 2 AUF3D204003 9600
32A 100mA 2 AUF3C203210 7260 40A 100mA 2 AUF3D204010 10575
300mA 2 AUF3C203230 7345 300mA 2 AUF3D204030 10970
30mA 2 AUF3C204003 7115 30mA 4 AUF3D206303 11315
40A 100mA 2 AUF3C204010 7260 63A 100mA 4 AUF3D206310 11965
300mA 2 AUF3C204030 7345 300mA 4 AUF3D206330 12075
30mA 4 AUF3C206303 8610 4P Adi
63A 100mA 4 AUF3C206310 9130 30mA 7.5 AUF3D401603 10220
300mA 4 AUF3C206330 9200 16A 100mA 7.5 AUF3D401610 11365
4P AC 300mA 7.5 AUF3D401630 11600
30mA 7.5 AUF3C401603 7780 30mA 7.5 AUF3D402003 10220
16A 100mA 7.5 AUF3C401610 8660 20A 100mA 7.5 AUF3D402010 11365
300mA 7.5 AUF3C401630 8835 300mA 7.5 AUF3D402030 11600
30mA 7.5 AUF3C402003 7780 30mA 7.5 AUF3D402503 10220
20A 100mA 7.5 AUF3C402010 8660 25A 100mA 7.5 AUF3D402510 11365
300mA 7.5 AUF3C402030 8835 300mA 7.5 AUF3D402530 11600
30mA 7.5 AUF3C402503 7780 30mA 7.5 AUF3D403203 10545
25A 100mA 7.5 AUF3C402510 8660 32A 100mA 7.5 AUF3D403210 11380
300mA 7.5 AUF3C402530 8835 300mA 7.5 AUF3D403230 11615
30mA 7.5 AUF3C403203 8035 30mA 7.5 AUF3D404003 10710
32A 100mA 7.5 AUF3C403210 8665 40A 100mA 7.5 AUF3D404010 11380
300mA 7.5 AUF3C403230 8860 300mA 7.5 AUF3D404030 11665
30mA 7.5 AUF3C404003 8160 30mA 7.5 AUF3D406303 12830
40A 100mA 7.5 AUF3C404010 8665 63A 100mA 7.5 AUF3D406310 13090
300mA 7.5 AUF3C404030 8890 300mA 7.5 AUF3D406330 13090
30mA 7.5 AUF3C406303 9780 30mA 12 AUF3D408003 37895
63A 100mA 7.5 AUF3C406310 9965 80A 100mA 12 AUF3D408010 38745
300mA 7.5 AUF3C406330 9965 300mA 12 AUF3D408030 38745
30mA 12 AUF3C408003 37895 30mA 12 AUF3D410003 40515
80A 100mA 12 AUF3C408010 38745 100A 100mA 12 AUF3D410010 41485
300mA 12 AUF3C408030 38745 300mA 12 AUF3D410030 41485
30mA 12 AUF3C410003 40515 *For technical details, please contact nearest branch office
100A 100mA 12 AUF3C410010 41485
300mA 12 AUF3C410030 41485
#For 2P AC/Adi D Curve RCBO, please contact nearest branch office Lauritz Knudsen, 15.08.2026 133PDF page 141 SPDs (Surge Protection Devices) [8536]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
SPDs (Surge Protection Devices) [8536]
Range Highlights 800V Solar Application
› Conforms to IEC 61643-11 Modules M.R.P.
Voltage
› Available in Type 2 and Type 1+2 Description Configuration 1 Mod =
(Uc)
Cat. No. (`)
17.5 mm Per Unit
› Type 2 : Protection against indirect
Type 2,
lightning and switching surges 3P 4 1500 AUSP023P40-1500 17250
Imax 40kA
» Maximum Discharge Current -
Type 1+2,
Imax up to 70kA 3P 5 1360 AUSP123P50-1360 51750
Iimp 12.5kA
› Type 1+2 : Protection against direct and
Type 1+2,
indirect lightning surges 3P 4 880 AUSP123P50-880 35500
Iimp 12.5kA
» Maximum Discharge Current -
New
Imax up to 100kA
440V Application (Common + Differential Mode) SPD Cartridges
Modules M.R.P. (`) M.R.P. (`)
Description Imax Configuration 1 Mod = Cat. No. Description Cat. No.
Per Unit Per Unit
17.5 mm
Type 1+2, 1P+N 2 AUSP121PN50D 13750 Cartridge for AUSP021PN15D AUSC021PN15D 3550
50kA
Iimp 12.5kA 3P+N 4 AUSP123PN50D 26335 Cartridge for AUSP021PN40D AUSC021PN40D 4420
1P+N 1 AUSP021PN40D 8595 Cartridge for
Type 2 40kA AUSC021PN70D 4725
AUSP023PN40D 17175 AUSP021PN70D / AUSP023PN70D
3P+N 2
#
Cartridge for AUSP023PN15D AUSC023PN15D 4640
1P+N 1 AUSP021PN15D 6875
Type 2 15kA #
3P+N 2 AUSP023PN15D 13525 Cartridge for AUSP023PN40D AUSC023PN40D 5900
Type 1+2, 1P+N 2 AUSP121PN100D 12360 Cartridge for
AUSC121PN100D 7080
100kA AUSP121PN100D / AUSP123PN100D
Iimp 8kA 3P+N 4 AUSP123PN100D 24290
Cartridge for
1P+N 2 AUSP021PN70D 13500 AUSP121PN50D / AUSP123PN50D AUSC121PN50D 7645
Type 2 70kA
3P+N 4 AUSP023PN70D 22485 Cartridge for AUSP023PN15D
#
AUSC023PN15DG 5390
#
Cartridge for AUSP023PN40D AUSC023PN40DG 5625
#
For technical details, please contact nearest branch office
ACCL (Automatic Changeover with Current Limiter) [8536]
Single Phase ACCL Three Phase ACCL
Range Highlights Range Highlights
› Conforms to IEC 60947-6, IEC 60947-3 › Settable overload current limit at DG side
› Wide Range of Current Ratings › Separate power consumption monitoring for
» (Generator side) - 1A to 30A Mains & Genset
» (Electricity Board side) - 30A › Settable overvoltage & undervoltage protection
› RoHS compliant › Settable TPN or SPN mode at DG side
Description Modules M.R.P. (`) › Protection against single phasing
1 Mod = 17.5 mm CAT Nos.
EB/DG Per Unit
Description (AC-1) M.R.P. (`)
30A/1A 4 AUCL01030001 3200 Cat. No.
EB/DG Per Unit
30A/1.5A 4 AUCL010301E5 3200 32A / 32A AUCL03032032 22095
30A/2A 4 AUCL01030002 3200 40A / 32A AUCL03040032 22771
30A/2.5A 4 AUCL010302E5 3200 40A / 40A AUCL03040040 24645
30A/3A 4 AUCL01030003 3200 50A / 50A AUCL03050050 35128
30A/4A 4 AUCL01030004 3200 63A / 50A AUCL03063050 38761
30A/5A 4 AUCL01030005 3200 63A / 63A AUCL03063063 43907
30A/6A 4 AUCL01030006 3200 80A / 80A AUCL03080080 66916
30A/8A 4 AUCL01030008 3200 125A / 125A AUCL03125125 112643
30A/10A 4 AUCL01030010 3200
30A/12A 4 AUCL01030012 3200
For 3 Phase ACCL programming video
30A/15A 4 AUCL01030015 3200
please scan the QR code or click here
30A/20A 4 AUCL01030020 3200
30A/30A 4 AUCL01030030* 3200
*Non-current limiting variant
Lauritz Knudsen, 15.08.2026 134PDF page 142 Changeover Switches [8536] Accessories
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Changeover Switches [8536] Accessories
Range Highlights Accessories [8538]
› Conforms to IEC 60947-3 and
IS/IEC 60947-3 All Half Module and One Module
› Available in 3 positions (I-O-II) with Accessories are common for
centre off position AU MCBs, RCCBs and RCBOs
› Utilization category AC-22A
Modules M.R.P. (`) Modules
Rating 1 Mod = 17.5 mm Cat. No.
Per Unit Description Configuration 1 Mod = Voltage CAT Nos.
17.5 mm
Double Pole
Auxiliary Contact 1NO+1NC 0.5 240V AC, 24V DC AUAXAC240 1380
25A 2 AUC00202500 2610
AUX/TAC* 1NO+1NC 0.5 240V AC, 24V DC AUATAC240 1615
40A 2 AUC00204000 3995
HR AUX/TAC* 1NO+1NC 0.5 240V AC, 24V DC AUATAC240HR 1615
63A 3 AUC00206300 4645
Undervoltage - 1 240V AC AUUVAC240 3260
Four Pole
Release - 1 24V DC AUUVDC024 3260
40A 4 AUC00404000 6885
Overvoltage Release - 1 240V AC AUOVAC240 4030
63A 6 AUC00406300 7805
- 1 240V AC AUSRAC240 3740
Shunt Release
- 1 24V DC AUSRDC024 3740
Suitable for 1Pole=1Mod devices: RCCBs,
Padlock-Suitable AUPD01 735
for Lock Hasp RCBOs, Changeover Switches up to 40A
3.5 - 5 mm dia. Suitable for 1Pole-1.5Mod devices:
max AUPD02 830
MCBs 80A-125A, Changeover Switch 63A
Note: Standard Pack Quantity for Padlock - 2 Nos.
*For 80A-125A MCBs please contact nearest branch office
Control & Monitoring Devices
Modular Contactors [8536] Energy Meters [9030]
Range Highlights
Range Highlights
› DIN mounting whole current operated meter
› Wide Range of Current Ratings:
» 25A, 40A and 63A › Accuracy Class 1.0
› Conforms to : › Inbuilt RS485 option
» IEC 61095, EN 61095 › Parameters : Voltage, Current, kW, kWh, kVA,
» IEC 60947-4-1, EN 60947-4-1 kVAh, RPM, Load hours, Interruptions
» IEC 60947-5-1
› Protection Degree IP 20 Description Modules
Cat. No.
M.R.P. (`)
1 Mod = 17.5 mm Per Unit
Single Phase - 60A 2 WD401010OOOO 3940
Modules Three Phase - 80A 5 WD402010OOOO 8530
M.R.P. (`)
Description (AC-1) 1 Mod = Cat. No.
17.5 mm Per Unit Single Phase - 60A (RS485) 2 WD401011OOOO 5825
25A-1NO 1 AUMC1002501 2800 Three Phase - 80A (RS485) 5 WD402011OOOO 12870
25A-2NO 1 AUMC2002501 3515
40A-2NO 3 AUMC2004003 6010
40A-3NO 3 AUMC3004003 8615
Indicating Lights [8531]
40A-4NO 3 AUMC4004003 10105
63A-2NO+2NC 3 AUMC2206303 10680
63A-3NO 3 AUMC3006303 10945
63A-4NO 3 AUMC4006303 12050
Accessory [8538]
Description Modules M.R.P. (`)
Auxiliary Contact, 2NO 0.5 AUMCAUX240 2620 Cat. No.
1 Mod = 17.5 mm Per Unit
RED 1 AUIL01RED00 1610
YELLOW 1 AUIL01YEL00 1610
BLUE 1 AUIL01BLU00 1610
GREEN 1 AUIL01GRE00 1610
RED-YELLOW-BLUE 1 AUIL01RYB00 1960
Auxiliary & Accessories for Exora MCBs [8538]
Description Cat. No. M.R.P. (`) Per Unit
Auxiliary Contact - 6A , 240V AC, (1NO+1NC), 0.5 Mod BZA11006 1325
Shunt Release - 240V AC, 1 Mod BZS00240 3625
Trip Alarm Contact - 6A, 240V AC, (1NO+1NC), 0.5 Mod BZT11006 1545
Lauritz Knudsen, 15.08.2026 135PDF page 143 Industrial Plugs & Sockets [8536] New
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Industrial Plugs & Sockets [8536] New
Plugs Socket
Highlights Highlights
› Conforms to IEC 60309 -1&2 › Conforms to IEC 60309 -1&2
› Mechanical Impact - IK08 › Mechanical Impact - IK08
› Ingress Protection - IP44 & IP67 › Ingress Protection - IP44 & IP67
› Fire Resistance - 850oC as per IEC 60695-2-11 › Fire Resistance - 850oC as per IEC 60695-211
› Easy Screw connection with same orientation › Easy Screw connection with same
of clamp screws orientation of clamp screws
Description M.R.P. (`) Description M.R.P. (`)
Cat NO Cat NO
Per Unit Per Unit
Plug - IP44 Socket - IP44
16A, 2P+E PSKPM30164 700 16A, 2P+E PSKSM30164 970
32A, 2P+E PSKPM30324 1105 32A, 2P+E PSKSM30324 1355
16A, 3P+E PSKPM40164 895 16A, 3P+E PSKSM40164 1140
32A, 3P+E PSKPM40324 1305 16A, 3P + N + E PSKSM50164 1240
16A, 3P+N+E PSKPM50164 945 32A, 3P + N + E PSKSM50324 1660
32A, 3P+N+E PSKPM50324 1260 Socket - IP67
Plug - IP67 16A, 2P+E PSKSM30167 1830
16A, 2P + E PSKPM30167 1560 32A, 2P+E PSKSM30327 2515
32A, 2P + E PSKPM30327 2200 63A, 2P+E PSKSM30637 6800
63A, 2P + E PSKPM30637 6250 16A, 3P+E PSKSM40167 2295
16A, 3P + E PSKPM40167 1760 63A, 3P+E PSKSM40637 6865
32A, 3P + E PSKPM40327 2785 16A, 3P + N + E PSKSM50167 2400
63A, 3P + E PSKPM40637 5950 32A, 3P + N + E PSKSM50327 2805
16A, 3P + N + F PSKPM50167 1885 63A, 3P + N + E PSKSM50637 6975
32A, 3P + N + E PSKPM50327 2400 125A, 3P + N + E PSKSM51257 21895
63A, 3P + N + E PSKPM50637 5965
125A, 3P + N + E PSKPM51257 18215
Socket Angled Socket Straight
Highlights Highlights
› Conforms to IEC 60309 -1&2 › Conforms to IEC 60309 -1&2
› Mechanical Impact - IK08 › Mechanical Impact - IK08
› Ingress Protection - IP44 & IP67 › Ingress Protection - IP44 & IP67
› Fire Resistance - 850oC as per IEC 60695-2-11 › Fire Resistance - 850oC as per IEC 60695-2-11
› Easy Screw connection with same orientation › Easy Screw connection with same orientation
of clamp screws Of clamp screws
Description M.R.P. (`) Description M.R.P. (`)
Cat NO Cat NO
Per Unit Per Unit
Socket Angled - IP44 Socket Straight- IP44
16A, 2P+E PSKSA30164 755 16A, 2P+E PSKSS30164 860
32A, 2P+E PSKSA30324 1335 32A, 2P+E PSKSS30324 1370
16A, 3P+E PSKSA40164 1140 32A, 3P+N+E PSKSS50324 1715
32A, 3P+E PSKSA40324 1575 Socket Straight- IP67
16A, 3P+N+E PSKSA50164 1215 16A, 2P+E PSKSS30167 1450
32A, 3P+N+E PSKSA50324 1540 63A, 2P+E PSKSS30637 7435
Socket Angled - IP67 63A, 3P+E PSKSS40637 6210
16A, 2P+E PSKSA30167 1440 63A, 3P+N+E PSKSS50637 6210
32A, 2P+E PSKSA30327 1875 125A, 3P+N+E PSKSS51257 20820
63A, 2P+E PSKSA30637 6140
32A, 3P+E PSKSA40327 2785
63A, 3P+E PSKSA40637 6150
32A, 3P+N+E PSKSA50327 2220
63A, 3P+N+E PSKSA50637 6275
125A, 3P+N+E PSKSA51257 20820
Lauritz Knudsen, 15.08.2026 136PDF page 144 Distribution Board suitable for
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Distribution Board suitable for
Aluminum shuttering (Mivan) Construction
DBs suitable for Aluminum Shuttering
Construction [8537]
SPN DBs
Highlights TPN DBs
› Available in CRCA sheet steel, RAL9003, powder coated Highlights
› Ready to use DBs - Provided with 100A insulated phase bus-bar | › Available in CRCA sheet steel, RAL 9003, powder coated
neutral bar/s with shroud/s | earth bar/s | sticking saddles | › Ready to use DBs - Provided with 100A insulated phase bus-bars
cement spill protector | color-coded interconnecting wire set | |neutral bar/s with shroud/s | earth bar/s | sticking saddles |
cable ties | blanking plates and circuit identification label cementspill protector | color-coded interconnecting wire set |
› With provision for DP MCB/Isolator/RCCB/RCBO as incomer and cable ties |blanking plates and circuit identification labels
SP MCBs as outgoings › With provision for FP MCB/Isolator/RCCB/RCBO as incomer and
SP MCBs as outgoings
No. of Modules M.R.P. (`)
Description Cat. Nos.
Incomer + Outgoing Per Unit No. of Modules M.R.P. (`)
Description Cat. Nos.
Incomer + Outgoing Per Unit
IP 43 - Metal Door
4 way 2 2 LTSD04M IP 43 - Metal Door
*
6 way 2 4 LTSD06M 4 way 8 4+4+4 LTTD04M *
*
8 way 2 6 LTSD08M 6 way 8 6+6+6 LTTD06M *
*
12 way 2 10 LTSD12M 8 way 8 8+8+8 LTTD08M *
*
16 way 2 14 LTSD16M * *For details, please contact nearest branch office
Lauritz Knudsen, 15.08.2026 137PDF page 145 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 146 SPN DB [8537] New
Extracted reference text; use the original PDF to check column alignment, variants and price units.
SPN DB [8537] New TPN DB [8537] New
Highlights Highlights
› Conforms to IEC 61439-1 & 3 › Conforms to IEC 61439-1 & 3
› IK 08-for single door DBs, IK 09-for double door Dbs › IK 08-for single door DBs, IK 09-for double door Dbs
› Available in CRCA sheet steel, RAL9003, powder coated › Available in CRCA sheet steel, RAL 9003, powder coated
› Ready to use DBs - Provided with 100A insulated phase bus-bar | › Ready to use DBs - Provided with 100A insulated phase
neutral bar/s with shroud/s | earth bar/s | sticking saddles | bus-bars |neutral bar/s with shroud/s | earth bar/s | sticking
cement spill protector | color-coded interconnecting wire set | saddles | cement spill protector | color-coded interconnecting wire
cable ties | blanking plates and circuit identification label set | cable ties | blanking plates and circuit identification labels
› With provision for DP MCB/Isolator/RCCB/RCBO as incomer and › With provision for FP MCB/Isolator/RCCB/RCBO as incomer and
SP MCBs as outgoings SPMCBs as outgoings
No. of Modules M.R.P. (`) No. of Modules M.R.P. (`)
Description Cat. Nos. Description Cat. Nos.
Incomer + Outgoing Per Unit Incomer Outgoing Per Unit
IP 30 - Single Door IP 30 - Single Door
4 way 2 2 DESPN004SDS 2175 4 way 4 4+4+4 DETPE004SDS 5630
6 way 2 4 DESPN006SDS 2275 6 way 4 6+6+6 DETPE006SDS 6910
8 way 2 6 DESPN008SDS 2620 4 way 8 4+4+4 DETPN004SDS 5925
12 way 2 10 DESPN012SDS 3110 6 way 8 6+6+6 DETPN006SDS 7340
16 way 2 14 DESPN016SDS 3810 8 way 8 8+8+8 DETPN008SDS 8655
18 way 2 16 DESPN018SDS 4430 12 way 8 12+12+12 DETPN012SDS 12475
IP 43 - Metal Door 16 way 8 16+16+16 DETPN016SDS 15210
4 way 2 2 DESPN004DDS 2815 IP 43 - Metal Door
6 way 2 4 DESPN006DDS 3245 4 way 4 4+4+4 DETPE004DDS 6615
8 way 2 6 DESPN008DDS 3435 6 way 4 6+6+6 DETPE006DDS 8220
12 way 2 10 DESPN012DDS 4125 4 way 8 4+4+4 DETPN004DDS 6855
16 way 2 14 DESPN016DDS 5265 6 way 8 6+6+6 DETPN006DDS 8540
18 way 2 16 DESPN018DDS 5515 8 way 8 8+8+8 DETPN008DDS 10300
IP 43 - Glazed Door 12 way 8 12+12+12 DETPN012DDS 15430
4 way 2 2 DESPN004GDS 3770 16 way 8 16+16+16 DETPN016DDS 19150
6 way 2 4 DESPN006GDS 4010 IP 43 - Glazed Door
8 way 2 6 DESPN008GDS 4360 4 way 4 4+4+4 DETPE004GDS 8985
12 way 2 10 DESPN012GDS 5310 6 way 4 6+6+6 DETPE006GDS 10800
16 way 2 14 DESPN016GDS 6595 4 way 8 4+4+4 DETPN004GDS 9350
18 way 2 16 DESPN018GDS 6975 6 way 8 6+6+6 DETPN006GDS 11380
IP 54 - Metal Door 8 way 8 8+8+8 DETPN008GDS 13495
4 way 2 2 DESPN00454S 9915 12 way 8 12+12+12 DETPN012GDS 20700
6 way 2 4 DESPN00654S 11055 16 way 8 16+16+16 DETPN016GDS 24880
8 way 2 6 DESPN00854S 11755 IP 54 - Metal Door
12 way 2 10 DESPN01254S 13500 4 way 4 4+4+4 DETPE00454S 22445
16 way 2 14 DESPN01654S 15030 6 way 4 6+6+6 DETPE00654S 26230
18 way 2 16 DESPN01854S 15365 4 way 8 4+4+4 DETPN00454S 23720
6 way 8 6+6+6 DETPN00654S 28565
8 way 8 8+8+8 DETPN00854S 31225
12 way 8 12+12+12 DETPN01254S 44015
16 way 8 16+16+16 DETPN01654S 52820
For ordering old DBs, replace Cat no with “DB” instead of “DE”.
Eg. - New DB Cat no for SPN 12W DD - DESPN012DDS, Old DB Cat no for same will be DBSPN012DDS. Old DBs are available till stock last.
Lauritz Knudsen, 15.08.2026 139PDF page 147 PPI DB [8537] New
Extracted reference text; use the original PDF to check column alignment, variants and price units.
PPI DB [8537] New TPN Phase Segregated DB [8537] New
Highlights Highlights
› Conforms to IEC 61439-1 & 3 › Conforms to IEC 61439-1 & 3
› IK 09-for double door DBs › IK 09-for double door DBs
› Available in CRCA sheet steel, RAL 9003, powder coated › Available in CRCA sheet steel, RAL 9003, powder coated
› Ready to use DBs - Provided with 100A insulated phase bus-bars | › Ready to use DBs - Provided with 100A insulated phase bus-bars |
neutral bar/s with shroud/s | earth bar/s | sticking saddles | neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement
cement spill protector | color-coded interconnecting wire set | spill protector | color-coded interconnecting wire set | cable ties |
cable ties | blanking plates and circuit identification labels blanking plates and circuit identification labels
› With provision for FP MCB / Isolator / RCCB / RCBO as incomer, › With provision for
DP RCCB/RCBO as sub-incomer and SP MCBs as outgoings » Modular Incomer - FP MCB/Isolator/RCCB/RCBO as incomer, DP
RCCB/RCBO as sub-incomer and SP MCBs as outgoings
» MCCB Incomer - MCCB* as incomer, DP RCCB/RCBO as sub-
incomer and SP MCBs as outgoings
Horizontal PPI DBs With Modular Incomer
IP 43 - Metal Door
No. of Modules No. of Modules
Description M.R.P. (`) Description M.R.P. (`)
Sub- Cat. Nos. Sub- Cat. Nos.
Incomer Outgoing Per Unit Incomer Outgoing Per Unit
Incomer Incomer
IP 43 - Metal Door IP 43 - Metal Door
4 way 8 2+2+2 4+4+4 DEHPI004DD 12305 4 way 8 4+4+4 4+4+4 DEPSG004DD 18070
6 way 8 2+2+2 6+6+6 DEHPI006DD 14570 6 way 8 4+4+4 6+6+6 DEPSG006DD 20375
8 way 8 2+2+2 8+8+8 DEHPI008DD 17470 8 way 8 4+4+4 8+8+8 DEPSG008DD 22735
12 way 8 2+2+2 12+12+12 DEHPI012DD 24075 12 way 8 4+4+4 12+12+12 DEPSG012DD 28205
16 way 8 2+2+2 16+16+16 DEHPI016DD 28885
Tier PPI DBs With MCCB Incomer
No. of Modules No. of Modules
Description M.R.P. (`) Description M.R.P. (`)
Sub- Cat. Nos. Sub- Cat. Nos.
Incomer Outgoing Per Unit Incomer* Outgoing Per Unit
Incomer Incomer
IP 43 - Metal Door IP 43 - Metal Door
6 way 8 2+2+2 6+6+6 DETPI006DD 15080 4 way MCCB 4+4+4 4+4+4 DEPGL004DD 24860
8 way 8 2+2+2 8+8+8 DETPI008DD 18905 6 way MCCB 4+4+4 6+6+6 DEPGL006DD 28425
10 way 8 2+2+2 10+10+10 DETPI010DD 19815 8 way MCCB 4+4+4 8+8+8 DEPGL008DD 32875
12 way 8 2+2+2 12+12+12 DETPI012DD 20995 12 way MCCB 4+4+4 12+12+12 DEPGL012DD 37075
16 way 8 2+2+2 16+16+16 DETPI016DD 23935 *Suitable for 3 Pole & 4 Pole DU100H, DU100D, DN0-100D &
12 way MCCB* 2+2+2 12+12+12 DETPL012DD 22455 DN0-100C MCCB as incomer
*Suitable for 3 Pole & 4 Pole DU100H, DU100D, DN0-100D &
DN0-100C MCCB as incomer
For ordering old DBs, replace Cat no with “DB” instead of “DE”.
Eg. - New DB Cat no for SPN 12W DD - DESPN012DDS, Old DB Cat no for same will be DBSPN012DDS. Old DBs are available till stock last.
Lauritz Knudsen, 15.08.2026 140PDF page 148 Vertical TPN DB with
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Vertical TPN DB with Vertical TPN DB
New New
MCCB Incomer [8537] with Modular Incomer [8537]
Highlights Highlights
› Conforms to IEC 61439-1 & 3 › Conforms to IEC 61439-1 & 3
› IK 09-for double door Dbs › IK 09-for double door Dbs
› Available in CRCA sheet steel, RAL 9003, powder coated › Available in CRCA sheet steel, RAL 9003, powder coated
› Ready to use DBs - Provided with insulated vertical phase bus-bars | › Ready to use DBs - Provided with insulated vertical phase bus-
neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement bars | neutral bar/s with shroud/s | earth bar/s | sticking saddles |
spill protector | color-coded interconnecting wire set | cable ties | cement spill protector | color-coded interconnecting wire set |
blanking plates and circuit identification labels cable ties | blanking plates and circuit identification labels
› With provision for 3 pole and 4 Pole MCCB* as incomer and SP/TP › With provision for FP MCB/Isolator/RCCB/RCBO as incomer and
MCBs as outgoings SP/ TP MCBs as outgoings
Up to 125A MCCB Incomer
No. of Modules M.R.P. (`)
Description Cat. Nos. No. of Modules
Incomer* Outgoing Per Unit
Description Cat. Nos.
M.R.P. (`)
Incomer Outgoing Per Unit
IP 43 - Metal Door
IP 43 - Metal Door
4 way MCCB 4+4+4 DEVTL004DD 20550
4 way 8 4+4+4 DEVTM004DD 17375
6 way MCCB 6+6+6 DEVTL006DD 23355
6 way 8 6+6+6 DEVTM006DD 19355
8 way MCCB 8+8+8 DEVTL008DD 25710
8 way 8 8+8+8 DEVTM008DD 22470
12 way MCCB 12+12+12 DEVTL012DD 34980
12 way 8 12+12+12 DEVTM012DD 30590
16 way MCCB 16+16+16 DEVTL016DD 42115
16 way 8 16+16+16 DEVTM016DD 36500
IP 54 - Metal Door
IP 54 - Metal Door
4 way MCCB 4+4+4 DEVTL00454 42960
4 way 8 4+4+4 DEVTM00454 37075
6 way MCCB 6+6+6 DEVTL00654 48990
6 way 8 6+6+6 DEVTM00654 40445
8 way MCCB 8+8+8 DEVTL00854 53035
8 way 8 8+8+8 DEVTM00854 44665
*Suitable for 3 Pole & 4 Pole DZ0 MCCB as incomer.
In case of any other MCCB frame requirement please contact nearest branch.
Vertical TPN DB
with MCCB Incomer [8537] New Flexi/Row DB [8537] New
Highlights
› Conforms to IEC 61439-1 & 3
Up to 250A MCCB Incomer › IK 09-for double door Dbs
› Available in CRCA sheet steel, RAL 9003, powder coated
› Ready to use DBs - neutral bar/s with shroud/s | earth bar/s |
sticking saddles | cement spill protector | cable ties | circuit
identification labels
No. of Modules M.R.P. (`)
Description Cat. Nos.
Per Unit
› With provision to mount modular devices as per requirement
Incomer* Outgoing
IP 43 - Metal Door
4 way MCCB 4+4+4 DEVTH004DD 26825
6 way MCCB 6+6+6 DEVTH006DD 30040
8 way MCCB 8+8+8 DEVTH008DD 33040
12 way MCCB 12+12+12 DEVTH012DD 39985
16 way MCCB 16+16+16 DEVTH016DD 53735
IP 54 - Metal Door
4 way MCCB 4+4+4 DEVTH00454 49080 Description No. of Modules M.R.P. (`)
Cat. Nos.
Per Row Per Unit
6 way MCCB 6+6+6 DEVTH00654 53585
55420 IP 43 - Metal Door
8 way MCCB 8+8+8 DEVTH00854
*Suitable for 3 pole and 4 pole DU250, DU250C & DN1 MCCB as incomer 2 Row 28 Module 14 DEROW228DD 8810
3 Row 42 Module 14 DEROW342DD 10560
4 Row 56 Module 14 DEROW456DD 11480
4 Row 64 Module 16 DEROW464DD 13355
For ordering old DBs, replace Cat no with “DB” instead of “DE”.
Eg. - New DB Cat no for SPN 12W DD - DESPN012DDS, Old DB Cat no for same will be DBSPN012DDS. Old DBs are available till stock last.
Lauritz Knudsen, 15.08.2026 141PDF page 149 TPN Phase Selector DB [8537] New
Extracted reference text; use the original PDF to check column alignment, variants and price units.
TPN Phase Selector DB [8537] New Plug & Socket DB [8537] New
Highlights Highlights
› Conforms to IEC 61439-1 & 3 › Conforms to IEC 61439-1 & 3
› IK 09-for double door Dbs › Suitable for Surface and Flush mounting
› Available in CRCA sheet steel, RAL 9003, powder coated › Available in CRCA sheet steel, RAL9003, powder coated
› Ready to use DBs - Provided with 3 nos. of 63A E&A rotary › Loose Metal Plugs & Sockets conforms to IS 8804; available in
switches | 3 nos. of rocker switches for phase identification | Single Phase & Three Phase
100A insulated phase bus-bars | neutral bar/s with shroud/s | set |
earth bar/s | sticking saddles | color-coded interconnecting wire
cable ties | blanking plates and circuit identification labels
› With provision for - FP MCB/Isolator/RCCB/RCBO as incomer and
SP MCBs as outgoings
Metal Plug & Socket Plastic Plug & Socket
Description No. of M.R.P. (`)
No. of Modules No. of Pins Cat. Nos.
M.R.P. (`) Modules Per Unit
Description Cat. Nos.
Incomer Outgoing Per Unit
Metal Plug & Sockets
IP 43 - Metal Door
10 A, 2 Pin + SC^ P+N 1 DEMPS110SD 2725
4 way 8 4+4+4 DEPSR004DD 21560
20 A, 2 Pin + SC^ P+N 1 DEMPS120SD 2930
6 way 8 6+6+6 DEPSR006DD 21905
20 A, 2 Pin + SC^ P+N 2 DEMPS220SD 3175
8 way 8 8+8+8 DEPSR008DD 23465
20 A, 3 Pin + SC^ 3P 3 DEMPS320SD 5380
10 way 8 10+10+10 DEPSR010DD 25315
32 A, 3 Pin + SC^ 3P 3 DEMPS332SD 6370
12 way 8 12+12+12 DEPSR012DD 26690
32 A, 3 Pin + SC^ 3P 4 DEMPS432SD 6775
63 A, 5 Pin + SC^ 3P+N+E 4 DEMPS463SD 22955
EV charging DB 8537] New
Plastic Plug & Sockets
16 A, 3 Pin P+N+E 2 DEPPS316SD 4455
Highlights 32 A, 3 Pin P+N+E 4 DEPPS332SD 4805
› Engineered specifically Charging 32 A, 5 Pin 3P+N+E 8 DEPPS532SD 8025
application - 3.3 kW
63 A, 5 Pin 3P+N+E 8 DEPPS563SD 20120
› Robust earth leakage, short circuit
and overload protection with RCBO-
› Factory fitted RCBO, switch and
socket Metal Plug [8536]
Description No. of Modules Cat. Nos. M.R.P. (`)
Per Unit M.R.P. (`)
Description No. of Pins Cat. Nos.
Per Unit
2 way EVDB 2 DEEVC002LD *
4 way EVDB 4 DEEVC004LD 10 A, 2 Pin + SC^ P+N MPS210P 335
*
*For details, please contact nearest branch office 20 A, 2 Pin + SC^ P+N MPS220P 355
20 A, 3 Pin + SC^ 3P MPS320P 475
32 A, 3 Pin + SC^ 3P MPS332P 900
Enclosure [8537] New
Note: Standard pack quantity - 20 nos.
Highlights
› Conforms to IEC 61439-1 & 3
› Suitable for Surface and Flush mounting Metal Socket [8536]
› Available in CRCA sheet steel, RAL9003, powder coated
› With provision to mount MCB/Isolator/RCCB/RCBO and
other modular devices
Description No. of Pins M.R.P. (`)
Cat. Nos.
IP 30 - Metal Door Per Unit
10 A, 2 Pin + SC^ P+N MPS210S 350
Description M.R.P. (`)
No. of Modules Cat. Nos.
Per Unit 20 A, 2 Pin + SC^ P+N MPS220S 390
IP 30 - Metal Door 20 A, 3 Pin + SC^ 3P MPS320S 530
2 way 2 DEENC002SD 1095 32 A, 3 Pin + SC^ 3P MPS332S 900
3 way 3 DEENC003SD 1095 ^ SC-Scraping Earth
Note: Standard pack quantity - 20 nos.
4 way 4 DEENC004SD 1095
6 way 6 DEENC006SD 1700
For ordering old DBs, replace Cat no with “DB” instead of “DE”.
Eg. - New DB Cat no for SPN 12W DD - DESPN012DDS, Old DB Cat no for same will be DBSPN012DDS. Old DBs are available till stock last.
Lauritz Knudsen, 15.08.2026 142PDF page 150 DBs with provision for TV / Telephone splitters [8537]
Extracted reference text; use the original PDF to check column alignment, variants and price units.
DBs with provision for TV / Telephone splitters [8537] New
Highlights No. of Modules M.R.P.
DB Type Description Cat. Nos. (`)
› Distribution Boards equipped with provisions to mount TV / Incomer + Outgoing Per Unit
Telephone splitters
› Available in SPN & TPN Dbs IP 43 - Metal Door
› Communication DB equipped with provisions to mount 2 ONT, Spike 6 way 2 4 DESPN006DDTV 6125
guard, Data switch, TV / Telephone splitters 8 way 2 6 DESPN008DDTV 6590
SPN 12 way 2 10 DESPN012DDTV 8105
16 way 2 14 DESPN016DDTV 9410
18 way 2 16 DESPN018DDTV 11125
4 way 8 4+4+4 DETPN004DDTV 12045
TPN 6 way 8 6+6+6 DETPN006DDTV 13920
8 way 8 8+8+8 DETPN008DDTV 16590
TV / Telephone Communication DB Communication DB DECOM01DD *
*For details, please contact nearest branch office
Cable End Boxes [8537]
Highlights DB Accessories
› Available in CRCA sheet steel, RAL9003,
powder coated
› Can be either at the top or bottom of the Busbar - Fork Type [8538]
distribution board
Highlights
› Available in Single Pole, Double
Description M.R.P. (`)
Cat. Nos. Pole, Three Pole and Four Pole
Per Unit
versions
CEB for SPN DBs
› Material : Copper
CEB-SPN Double Door, 4 way DESPN004CBS 1200
CEB-SPN Double Door, 6 way DESPN006CBS 1295 M.R.P. (`) Std. Pack
Description Cat. Nos..
Per Unit Qty.
CEB-SPN Double Door, 8 way DESPN008CBS 1450
CEB-SPN Double Door, 12 way DESPN012CBS 1610 SP 13 Mod BSP13 535 5
CEB-SPN Double Door, 16 way DESPN016CBS 2270 SP 56 Mod BSP56 2200 5
CEB-SPN Double Door, 18 way DESPN018CBS 2340 DP 12 Mod BDP12 955 5
CEB for TPN DBs TP 12 Mod BTP12 1035 5
CEB-TPE Double Door, 4 way DETPE004CBS 1555 FP 12 Mod BFP12 2040 5
CEB-TPE Double Door, 6 way DETPE006CBS 2215 End Caps for SP ECP01 35 10
CEB-TPN Double Door, 4 way DETPN004CBS 1630 End Caps for DP/TP ECP03 75 10
CEB-TPN Double Door, 6 way DETPN006CBS 2285 End Caps for FP ECP04 120 10
CEB-TPN Double Door, 8 way DETPN008CBS 2870
CEB-TPN Double Door, 12 way DETPN012CBS 4780 Blanking Plates [8538]
CEB-TPN Double Door, 16 way DETPN016CBS 4825 Highlights
CEB for Horizontal PPI DBs › Available in One module and Half module
CEB-Horz. PPI Double Door, 4 way DEHPI004CB 2410
CEB-Horz. PPI Double Door, 6 way DEHPI006CB 3010
Description M.R.P. (`) Std.Pack
CEB-Horz. PPI Double Door, 8 way DEHPI008CB 3775 Cat. Nos.
Per Unit Qty.
CEB-Horz. PPI Double Door, 12 way DEHPI012CB 4735
One Module BKP10 35 10
CEB-Horz. PPI Double Door, 16 way DEHPI016CB 5150
Half Module BKP05 35 10
CEB for VTPN DBs
CEB-VTPN Double Door,
Modular Incomer DEVTMXXXCB 1610 Padlock [8301]
CEB-VTPN Double Door, Highlights
MCCB Incomer DEVTXXXXCB 5690
› Version with standard lock and a
CEB for Phase Segregated DBs common key
PDK02
CEB-PSG Double Door, 4 way DEPSG004CB 4225
CEB-PSG Double Door, 6 way DEPSG006CB 5035 Std.
Description M.R.P. (`)
Cat. Nos. Pack
Per Unit
CEB-PSG Double Door, 8 way DEPSG008CB 5560 Qty.
CEB-PSG Double Door, 12 way DEPSG012CB 6190 Lock and Key Kit PDK02 935 5
For ordering old DBs, replace Cat no with “DB” instead of “DE”.
Eg. - New DB Cat no for SPN 12W DD - DESPN012DDS, Old DB Cat no for same will be DBSPN012DDS. Old DBs are available till stock last.
Lauritz Knudsen, 15.08.2026 143PDF page 151 Discontinued Products/Suggested Alternate Products
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Discontinued Products/Suggested Alternate Products
Product Group Discontinued Products Suggested Alternate Products
1. OMEGA ACB with MTX 3.5 Release
ACB C-Power ACB with SR71 Release 2. C-Power Bus-Coupler ACB + numrAL FDR22 +
Protection class CT + Shunt Release
MCCB DZ6-400Z 3P & 4P MCCBs 50/40kA (Icu/Ics) DZ6-400Z 3P & 4P MCCBs 50/50kA (Icu/Ics)
DZ0 100A 3P Spreaders - EM99282OOOO DN0 100A 3P Spreaders - CM97785OOOO
MCCB
DZ0 100A 4P Spreaders - EM99283OOOO DN0 100A 4P Spreaders - CM97921OOOO
Contactors MN0 control contactor, its spares and accessories MO0 control contactor, its spares and accessories
Contactors MR Contactors MNX 2P/ MU-2P
FDP Common Mode SPD Common+ Differential Mode SPD
FDP AU-CON convertor module TG1000 Gateway
Soft Starters CSX xS1000
Soft Starters CSXi xS2000
Soft Starters EMX4e xS3000
Soft Starters EMX4i xS4000
AC Drives x2000 Series xD Series
Protection Relay MRP11 RPR11
Fusegear Fuse Mounting Kit
Fusegear FNX Series FN Series
Lauritz Knudsen, 15.08.2026 144PDF page 152 General All prices are on Maximum retail price basis inclusive of
Extracted reference text; use the original PDF to check column alignment, variants and price units.
General All prices are on Maximum retail price basis inclusive of
all duties, GST & any other tax as applicable.
Terms
All products listed in the price list are covered by a warranty
against manufacturing defects for a period of 18* months from
the date of purchase. For Lauritz Knudsen MCBs & Isolators
mounted inside Lauritz Knudsen Distribution Boards, an extended
warranty of 5 years is provided.
Warranty In the event of a defect due to faulty workmanship or other
Policy associated reasons, we will, at our discretion, remedy the defect
or replace the faulty parts or the entire product as soon as
possible, free of cost.
However, the warranty is subject to proper usage, efficient
maintenance, and does not cover defects arising from fire,
accidents, inefficient maintenance, faulty operation, or deliberate
or accidental damage. It also does not cover damage to power
electronic components such as thyristors & IGBTs, which
primarily fail due to overtemperature & over-voltage. Users need
to take adequate precautions to eliminate these conditions.
Manufacturer shall not be responsible & liable for any special,
incidental, social or consequential (including lost profits) loss,
consequential damages, injury or damages (punitive) of any
kind solely attributable to defect or failure of its products.
Manufacturer shall not be liable in any manner for the issue of
or failure in the performance of other equipment the product is
attached to.
Lauritz Knudsen Electrical & Automation has over seven decades
of experience in providing after sales service for low voltage
distribution system in every type of industry & commercial
complex in India
Comprehensive Lauritz Knudsen Electrical & Automation offers the following
services, partnering you in your maintenance of low voltage
Service Support distribution products:
› Regular Maintenance
› Preventive Maintenance Programme
› On Call
› Annual Maintenance Contract
› Product Support for Managing Obsolescence-
Please visit www.LK-EA.com for latest update on our products & prices.PDF page 153 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 154 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 155 Illustrated catalog page
Extracted reference text; use the original PDF to check column alignment, variants and price units.
This page is illustrated. Open the original PDF to view its contents.
PDF page 156 Sri Laxmi Agencies
Extracted reference text; use the original PDF to check column alignment, variants and price units.
Sri Laxmi Agencies
Old Bhoiguda,
4-3-57/1, 1st Floor
Secunderabad 500003, Telangana
India
Phone No - 04027712427
Email - srilaxmiagencies1995@gmail.com
SP 50494 ABNo matching text found. Try a shorter model code or check the original PDF, including illustrated pages.
BEFORE YOU SPECIFY
Make an informed choice.
LET’S GET THE SPECIFICATION RIGHT
From your shortlist
to a clear quote.
Share the catalog number, rating and quantity. We’ll confirm the current price, availability and lead time.