01

Digital soft starters

02

Optional modules and cards

MANUFACTURER REFERENCE / August 2026

Details, down to
the catalog number.

Browse the supplied specification pages. Published MRP is a dated manufacturer reference; request a current Nova quote and confirm the tax basis and pack size.

ESP Lauritz Knudsen Price List (1).pdf ↗ · PDF pages 127–129

3 catalog pages

PDF page 127 Digital Soft Starters [8504]
View original PDF page ↗

Extracted reference text; use the original PDF to check column alignment, variants and price units.

Digital Soft Starters [8504]

                 Soft Starters                                                                                                                   M.R.P.
                                                                                                                                                                 Bypass
Range: 18A to 200A                                              Description                                                Cat. No.               (`)
                                                                                                                                                                Contactor
                                                                                                                                                Per Unit
                                                               xS1000,18A,M:200-440VAC,C:110/230-440VAC             XS1000-0018-B44111              *
                                                               xS1000,34A,M:200-440VAC,C:110/230-440VAC             XS1000-0034-B44111              *
                                                               xS1000,42A,M:200-440VAC,C:110/230-440VAC             XS1000-0042-B44111              *
                                                               xS1000,48A,M:200-440VAC,C:110/230-440VAC             XS1000-0048-B44111              *
                                                               xS1000,60A,M:200-440VAC,C:110/230-440VAC             XS1000-0060-B44111              *
xS1000 Soft Starters : For Standard Applications               xS1000,75A,M:200-440VAC,C:110/230-440VAC             XS1000-0075-B44111              *           Built - In
› Inbuilt Bypass Contactor                                     xS1000,85A,M:200-440VAC,C:110/230-440VAC             XS1000-0085-B44111              *
› Soft Start / Soft Stop                                       xS1000,100A,M:200-440VAC,C110/230-440VAC
› Compact in size
                                                                                                                    XS1000-0100-B44111              *
                                                               xS1000,140A,M:200-440VAC,C110/230-440VAC             XS1000-0140-B44111              *
› Truly plug & play
› Communication options available                              xS1000,170A,M:200-440VAC,C110/230-440VAC             XS1000-0170-B44111              *
                                                               xS1000,200A,M:200-440VAC,C110/230-440VAC             XS1000-0200-B44111              *



                 Soft Starters                                                                                                                   M.R.P.
                                                                                                                                                                 Bypass
Range: 18A to 200A                                              Description                                                Cat. No.               (`)
                                                                                                                                                                Contactor
                                                                                                                                                Per Unit
                                                               xS2000,18A,M:200-440VAC,C:110/230-440VAC             XS2000-0018-B44111              *
                                                               xS2000,34A,M:200-440VAC,C:110/230-440VAC             XS2000-0034-B44111              *
                                                               xS2000,42A,M:200-440VAC,C:110/230-440VAC             XS2000-0042-B44111              *
                                                               xS2000,48A,M:200-440VAC,C:110/230-440VAC             XS2000-0048-B44111              *
                                                               xS2000,60A,M:200-440VAC,C:110/230-440VAC             XS2000-0060-B44111              *
                                                               xS2000,75A,M:200-440VAC,C:110/230-440VAC             XS2000-0075-B44111              *
xS2000 Soft Starters : For standard applications
                                                               xS2000,85A,M:200-440VAC,C:110/230-440VAC             XS2000-0085-B44111              *           Built - In
› Inbuilt Bypass Contactor
› Soft start / Soft stop / Adjustable current limit            xS2000,100A,M:200-440VAC,C110/230-440VAC             XS2000-0100-B44111              *
› Essential motor protections against                          xS2000,140A,M:200-440VAC,C110/230-440VAC             XS2000-0140-B44111              *
  » Overload                                                   xS2000,170A,M:200-440VAC,C110/230-440VAC             XS2000-0170-B44111              *
  » Single phasing                                             xS2000,200A,M:200-440VAC,C110/230-440VAC             XS2000-0200-B44111              *
  » Instantaneous over current
  » Phase sequence reversal
  » Abnormality in supply
  » Unbalanced current                                         Note:
› Thermistor protection through PTC                            * For prices please contact nearest branch office
› Excess start time setting                                    The above xS1000 & xS2000 ratings are based on 400% starting current, 10 starts per hour up to 60A & 6
› Communication options available                              starts per hour for 75A & above, 6 seconds starting time and ambient temperature of 40°C.
› PC Interface as optional                                     For proper sizing of soft starter based on the application parameters please use Winstart Software.




Ordering Information for xS1000 & xS2000 Series Soft Starter

  xS      nnnn    -   1234   -     B       V       C       D     F      F
                                                                                We recommend the use of :
                                                                                1. Line Contactor : This will isolate and protect the soft starter SCR's from
                                                                                   any voltage transient while it's not in operation.
    xS       Soft starters
                                                                                2. Bypass Contactor (For models without built-in bypass) : This will
             Soft starter Name
                                                                                   bypass and protect the soft starter SCR's while in running state from
   nnnn       1000 xS1000
                                                                                   Current and Voltage transient's.
               2000 xS2000
             Current Rating                                                     3. Semiconductor fuses : This will protect the starter SCR's during
   1234
               1234 Nominal Current Rating                                         starting and stopping states from current transient's and excess I²T.
             Bypass Type
     B                                                                          Note:
               B Internal Bypass
             Mains Voltage                                                      * For prices please contact nearest branch office
     V         4 3Ph, 200-440VAC                                                 Soft Starters are covered under HSN code 8504 40 90 and are charged
                                                                                 at 18% GST.
               5 3Ph, 200-575VAC
             Control Voltage
     C         1 24V AC/DC
               4 110/230-440V AC
             Graphical Display
     D
               1 No Graphical Display
             Future Use
     F
               1 Future Use
             Future Use
     F
               1 Future Use




                                                                                                                                   Lauritz Knudsen, 15.08.2026               120
PDF page 128 Digital Soft Starters [8504]
View original PDF page ↗

Extracted reference text; use the original PDF to check column alignment, variants and price units.

Digital Soft Starters [8504]

             Soft Starters                                                                                                                 M.R.P.
                                                                                                                                                        Bypass
                                                                Description                                          Cat. No.               (`)
Range: 24A to 580A                                                                                                                                     Contactor
                                                                                                                                          Per Unit
                                                                xS3000,24A,M:200-525VAC,C:110/220VAC         XS3000-0024-B52211              *
                                                                xS3000,42A,M:200-525VAC,C:110/220VAC         XS3000-0042-B52211              *
                                                                xS3000,52A,M:200-525VAC,C:110/220VAC         XS3000-0052-B52211              *
                                                                xS3000,64A,M:200-525VAC,C:110/220VAC         XS3000-0064-B52211              *
                                                                xS3000,69A,M:200-525VAC,C:110/220VAC         XS3000-0069-B52211              *
                                                                xS3000,105A,M:200-525VAC,C:110/220VAC        XS3000-0105-B52211              *
                                                                xS3000,115A,M:200-525VAC,C:110/220VAC        XS3000-0115-B52211              *
                                                                xS3000,135A,M:200-525VAC,C:110/220VAC        XS3000-0135-B52211              *
› Built in bypass contactor                                     xS3000,184A,M:200-525VAC,C:110/220VAC        XS3000-0184-B52211              *          Built - In
› Compact & Flexible Design
› Screw-less design for easy and fast servicing
                                                                xS3000,200A,M:200-525VAC,C:110/220VAC        XS3000-0200-B52211              *
› USB port for easy and fast commissioning and                  xS3000,229A,M:200-525VAC,C:110/220VAC        XS3000-0229-B52211              *
  data extraction                                               xS3000,250A,M:200-525VAC,C:110/220VAC        XS3000-0250-B52211              *
› Full graphical display with multi-languages                   xS3000,352A,M:200-525VAC,C:110/220VAC        XS3000-0352-B52211              *
  support                                                       xS3000,397A,M:200-525VAC,C:110/220VAC        XS3000-0397-B52211              *
› Built-in Simulation Mode
› 384 event logs                                                xS3000,410A,M:200-525VAC,C:110/220VAC        XS3000-0410-B52211              *
› Communication options available                               xS3000,550A,M:200-525VAC,C:110/220VAC        XS3000-0550-B52211              *
› Fire Mode Function                                            xS3000,580A,M:200-525VAC,C:110/220VAC        XS3000-0580-B52211              *
› Starts per hour count


                Soft Starters                                    Description
                                                                                                                                           M.R.P.
                                                                                                                                                        Bypass
                                                                                                                     Cat. No.               (`)
Range: 24A to 1250A                                                                                                                                    Contactor
                                                                                                                                          Per Unit
                                                                 xS4000,24A,M:200-525VAC,C:110/220VAC         XS4000-0024-B52211             *
                                                                 xS4000,42A,M:200-525VAC,C:110/220VAC         XS4000-0042-B52211             *
                                                                 xS4000,52A,M:200-525VAC,C:110/220VAC         XS4000-0052-B52211             *
                                                                 xS4000,64A,M:200-525VAC,C:110/220VAC         XS4000-0064-B52211             *
                                                                 xS4000,69A,M:200-525VAC,C:110/220VAC         XS4000-0069-B52211             *
                                                                 xS4000,105A,M:200-525VAC,C:110/220VAC        XS4000-0105-B52211             *
                                                                 xS4000,115A,M:200-525VAC,C:110/220VAC        XS4000-0115-B52211             *
                                                                 xS4000,135A,M:200-525VAC,C:110/220VAC        XS4000-0135-B52211             *
                                                                 xS4000,184A,M:200-525VAC,C:110/220VAC        XS4000-0184-B52211             *
› Built in bypass contactor
› Compact & Flexible Design                                      xS4000,200A,M:200-525VAC,C:110/220VAC        XS4000-0200-B52211             *
› Screw-less design for easy and fast servicing                  xS4000,229A,M:200-525VAC,C:110/220VAC        XS4000-0229-B52211             *
                                                                                                                                                        Built - In
› USB port for easy and fast commissioning and                   xS4000,250A,M:200-525VAC,C:110/220VAC        XS4000-0250-B52211             *
  data extraction                                                                                             XS4000-0352-B52211
                                                                 xS4000,352A,M:200-525VAC,C:110/220VAC                                       *
› Full graphical display with multi-languages                                                                 XS4000-0397-B52211
  support
                                                                 xS4000,397A,M:200-525VAC,C:110/220VAC                                       *
› Real time graphs of motor operating                            xS4000,410A,M:200-525VAC,C:110/220VAC        XS4000-0410-B52211             *
  performance                                                    xS4000,550A,M:200-525VAC,C:110/220VAC        XS4000-0550-B52211             *
› 384 event logs with time stamping                              xS4000,580A,M:200-525VAC,C:110/220VAC        XS4000-0580-B52211             *
› Advanced protection system                                     xS4000,835A,M:200-525VAC,C:110/220VAC        XS4000-0835-B52211             *
› Communication options available                                xS4000,940A,M:200-525VAC,C:110/220VAC  XS4000-0940-B52211                   *
› Smart card for level controlled pump activation
  and pump protection                                            xS4000,1070A,M:200-525VAC,C:110/220VAC XS4000-1070-B52211                   *
› Under Voltage / Over Voltage protection                        xS4000,1230A,M:200-525VAC,C:110/220VAC XS4000-1230-B52211                   *
  available                                                      xS4000,1250A,M:200-525VAC,C:110/220VAC XS4000-1250-B52211                   *
› Fire Mode Function                                             xS4000,735A,M:200-525VAC,C:110/220VAC  XS4000-0735-C52211                   *       External bypass
› Starts per hour count                                          xS4000,830A,M:200-525VAC,C:110/220VAC        XS4000-0830-C52211             *          contactor
                                                                                                                                                       (AC1 rating)
› Power through function available
                                                                 xS4000,1025A,M:200-525VAC,C:110/220VAC XS4000-1025-C52211                   *       All protections
› Scheduling based on RTC                                                                                                                             remain active
                                                                 xS4000,1170A,M:200-525VAC,C:110/220VAC XS4000-1170-C52211                   *        during bypass
                                                                                                                                                        operation
                                                                 xS4000,1220A,M:200-525VAC,C:110/220VAC XS4000-1220-C52211                   *
                                                                                      Note:
   xS    nnnn    -   1234    -    B         V       C     D      F        F           * For prices please contact nearest branch office
                                                                                       Prices for 1000V and External Bypass soft starter below 735A available on
   xS    Soft starters                                  Control Voltage                request Soft Starters are covered under HSN code 8504 40 90 and are charged at
         Soft starter Name                      C         1 24V AC/DC                  18% GST.
  nnnn    3000 xS3000                                     2 110-120/220-240V AC
           4000 xS4000                                  Graphical Display             We recommend the use of :
                                                D
         Current Rating                                   2 Fixed Graphical Display
  1234                                                                                1. Line Contactor : This will isolate and protect the soft starter SCR's from any
           1234 Nominal Current Rating                  Future Use
                                                F                                        voltage transient while it's not in operation.
         Bypass Type                                      1 Future Use
   B       B Internal Bypass
                                                                                      2. Semiconductor fuses : This will protect the starter SCR's during starting and
                                                        Future Use
           C Continuous / External Bypass
                                                F                                        stopping states from current transient's and excess I2T.
                                                          1 Future Use
         Mains Voltage                                                                3. Bypass Contactor (For models without built-in bypass) : This will bypass and
           5 3Ph, 200-525VAC                                                             protect the soft starter SCR's while in running state from Current and Voltage
   V                                                                                     transient's.
           6 3Ph, 380-600VAC
           7 3Ph, 380-690VAC
                                                                                                                            Lauritz Knudsen, 15.08.2026              121
PDF page 129 Digital Soft Starters [8504]
View original PDF page ↗

Extracted reference text; use the original PDF to check column alignment, variants and price units.

Digital Soft Starters [8504]

Optional Modules/Cards for xS Series




                                                                                                 M.R.P.
 Description                                                                    Cat. No.          (`)
                                                                                                Per Unit
 xS1000 & xS2000 Modbus RTU Card                                            XSCI-RTU-121            *
 xS1000 & xS2000 Modbus TCP Card                                            XSCI-TCP-123            *
 xS1000 & xS2000 Profibus Card                                              XSCI-PDP-121            *
 xS1000 & xS2000 Profinet Card                                              XSCI-PFN-122            *
 xS1000 & xS2000 Ethernet Card                                              XSCI-ETH-122            *
 xS1000 & xS2000 DeviceNet Card                                             XSCI-DEN-121            *
 xS1000 & xS2000 USB Interface Card                                         XSCI-USB-121            *
 xS1000 & xS2000 Operator interface Card                                    XSOP-DOC-100            *
 xS1000 & xS2000 Digital Operator Kit                                       XSOP-DOK-100            *
 xS3000 and xS4000 Modbus RTU Card                                          XSCI-RTU-341            *
 xS3000 and xS4000 Modbus RTU + GF Card                                     XSCI-RTU-342            *
 xS3000 and xS4000 Modbus TCP + GF Card                                     XSCI-TCP-343            *
 xS3000 and xS4000 Profibus Card                                            XSCI-PDP-341            *
 xS3000 and xS4000 Profinet + GF Card                                       XSCI-PFN-343            *
 xS3000 and xS4000 Ethernet + GF Card                                       XSCI-ETH-343            *
 xS3000 and xS4000 DeviceNet Card                                           XSCI-DEN-341            *
 xS3000 and xS4000 Operator & Cable                                         XSOP-DOP-200            *
 xS3000 and xS4000 Operator Interface Card                                  XSOP-DOC-200            *
 xS3000 and xS4000 Digital Operator Kit                                     XSOP-DOK-200            *
 xS3000 and xS4000 Pumping Smart Card                                       XSSC-PSC-341            *

Note:
* For prices please contact nearest branch office
Soft Starters are covered under HSN code 8504 40 90 and are charged
at 18% GST.




                                                                      Lauritz Knudsen, 15.08.2026       122

BEFORE YOU SPECIFY

Make an informed choice.

LET’S GET THE SPECIFICATION RIGHT

From your shortlist
to a clear quote.

Share the catalog number, rating and quantity. We’ll confirm the current price, availability and lead time.