LAURITZ KNUDSEN / ELECTRICAL & AUTOMATION

Motor protection relays

Protection and monitoring options for motor circuits.

NOVA TRADING RANIGUNJ · SECUNDERABAD
Motor protection relays — manufacturer catalog illustration
THE COLLECTION / 2026LAURITZ KNUDSEN

RANGE AT A GLANCE

Choose the right configuration.

Share supply voltage, load or motor details, control requirements, enclosure conditions and required accessories for model selection.

01

Thermal overload relays

02

REO electronic overload

03

eMPR protection

04

iMMR intelligent motor management

MANUFACTURER REFERENCE / August 2026

Details, down to
the catalog number.

Browse the supplied specification pages. Published MRP is a dated manufacturer reference; request a current Nova quote and confirm the tax basis and pack size.

ESP Lauritz Knudsen Price List (1).pdf ↗ · PDF pages 19–27

9 catalog pages

PDF page 19 Thermal Overload Relays [8536]
View original PDF page ↗

Extracted reference text; use the original PDF to check column alignment, variants and price units.

Thermal Overload Relays [8536]

Type MN - Suitable for MNX Contactor                                             Type RTO - Suitable for MO Contactor
Features                                                                         Features
› Available in 3 frame sizes from 0.2-570 A                                      › Ambient temperature compensated upto 55oC
› Ambient temperature compensated up to 55оC                                     › Built-in Single Phasing protection
› Built-in Single Phasing protection                                             › Manual and auto reset mode
› Manual and auto reset mode                                                     › Front access to START and STOP/RESET buttons
› Conforms IS/IEC 60947-4-1 & IEC 60947-4-1                                      › Sealable in OFF condition
                                                                                 › Conforms IS/IEC 60947-4-1 & IEC 60947-4-1




   MN 2               MN 5                   MN 12                  MN 12L                    RTO 1                  RTO 2                 RTO 3

 Type of                                                      M.R.P.     Std.     Type of                                                      M.R.P.     Std.
                    Relay Range                                                                       Relay Range
 Mounting                                   Cat. No.           (`)       Pkg.     Mounting                                     Cat. No.         (`)       Pkg.
                        (A)                                                                               (A)
 (Operation)                                                 Per Unit   (Nos.)    (Operation)                                                 Per Unit   (Nos.)
                                   Direct Mounting on MNX 9 - 40                                                    Direct Mounting on MO 9 - 45
                      0.2 - 0.33        SS94141OOEO            2680      10                           0.23 - 0.41            CS96355OOFO       4090       10
                       0.3 - 0.5        SS94141OOGO            2680      10                           0.31 - 0.55            CS96355OOGO       4090       10
                     0.45 - 0.75        SS94141OOJO            2680      10                           0.55 - 0.85            CS96355OOJO       4090       10
                        0.6 - 1         SS94141OOKO            2680      10                            0.78 - 1.2            CS96355OOLO       4090       10
                       0.9 - 1.5        SS94141OOMO            2780      10                            1.2 - 2.0             CS96355OONO       4090       10

 MN 2                  1.4 - 2.3        SS94141OOPO            2780      10                            1.9 - 2.8             CS96355OOPO       4280       10
                                                                                  RTO - 1
 (Directly              2 - 3.3         SS94141OOQO            2780      10                            2.4 - 3.6             CS96355OOQO       4280       10
                                                                                  (Directly
 Operated)               3-5            SS94141OOSO            2780      10                            3.5 - 5.2             CS96355OOSO       4280       10
                                                                                  Operated)
                       4.5 - 7.5        SS94141OOUO            2780      10                            4.6 - 6.7             CS96355OOTO       4280       10
                        6 - 10          SS94142OOVO            2780      10                            6.7 - 9.7             CS96355OOVO       4280       10
                        9 - 15          SS94142OOBO            2900      10                            8.5 - 12.5            CS96355OOAO       4330       10
                       14 - 23          SS94144OODO            3070      10                           12.5 - 18.5            CS96356OOCO       4800       10
                       20 - 33          SS94145OOEO            4630      10                            17 - 25.5             CS96356OODO       4800       10
                       24 - 40          SS94145OOFO            4840      10                             25 - 37              CS96356OOEO       7300       10
                                   Direct Mounting on MNX 50 - 80                                       35 - 45              CS96356OOGO       7530       10
                        9 - 15          SS94135OOBO            5730      10                                         Direct Mounting on MO 50 - 70
                       14 - 23          SS94135OODO            5730      10                             5 - 7.5              CS96366OOUO        8610       1
 MN 5                                                                                                    7 - 11              CS96366OOVO        8610       1
                       20 - 33          SS94136OOEO            5730      10
 (Directly
                       30 - 50          SS94136OOGO            7610      10       RTO - 2              10.5 - 16             CS96366OOBO        8610       1
 Operated)
                       36 - 60          SS94136OOTO            7700      10       (Directly             15 - 21              CS96366OOCO        8610       1
                                                                                  Operated)             20 - 31              CS96366OOEO        8960       1
                       45 - 75          SS94137OOJO            8870      10
                       66 - 110         SS94137OOKO            9520      10                             30 - 43              CS96366OOFO        9970       1

                                         Separate Mounting                                              40 - 57              CS96366OOSO      11920        1

                                        SB94211OOGO                                                     50 - 75              CS96367OOJO      12320        1
                      28 - 46.5                              14010        1
                                                                                                                   Direct Mounting on MO 80 - 110
                       42 - 69          SS94138OOHO          14010        1
                                                                                                        23 - 30              CS90873OOEO      13140        1
 MN 12                 60 - 100         SS94138OOKO          14010        1
 (CT Operated)                                                                    RTO - 3               29 - 38              CS96303OOQO      13660        1
                       90 - 150         SS94138OOMO          14010        1
                                                                                  (Directly             37 - 49              CS96304OOGO      14090        1
                      135 - 225         SS94138OOPO          15700        1
                                                                                  Operated)             47 - 62              CS96312OOTO      14350        1
                      180 - 300         SS94139OOQO          17610        1
                                                                                                        60 - 78              CS96313OOJO      16910        1
                      270 - 450         SS94139OORO          22110        1
                                                                                                       75 - 110              CS96314OOKO      18470        1
                                         Separate Mounting
                                                                                                                         Separate Mounting
                       42 - 69          SS94127OOHO          41570        1
                                                                                                       23.4 - 36             CS97096OOGO      22180        1
                       60 - 100         SS94127OOKO          41570        1
 MN 12L #                                                                                               36 - 60              CS97096OOJO      22180        1
 (CT Operated)         90 - 150         SS94127OOMO          41570        1
                                                                                                        57 - 84              CS97096OOKO      22180        1
                      135 - 225         SS94127OOPO          41570        1       RTO - 4
                                                                                  (CT Operated)         72 - 108             CS97096OOLO      22180        1
                      180 - 300         SS94127OOQO          41570        1
                                                                                                       105 - 156             CS97096OOMO      22180        1
                      340 - 570         SS94127OOSO          41570        1                            138 - 201             CS97096OONO      26320        1
# For motors with longer starting time (Trip class 30)                                                 201 - 291             CS97096OOQO      27490        1
                                                                                                       255 - 375             CS97096OORO      33710        1




                                                                                                                       Lauritz Knudsen, 15.08.2026             12
PDF page 20 Thermal Overload Relays [8536]
View original PDF page ↗

Extracted reference text; use the original PDF to check column alignment, variants and price units.

Thermal Overload Relays [8536]

Type RX                                                                            Type ML
Features
› Direct mounting on MX contactor
› Built-in single phasing protection
› Front access to START and STOP/RESET buttons                                     ML

 Type of                                                       M.R.P.     Std.      Type of                                                    M.R.P.      Std.
                        Relay Range                                                                 Relay Range
 Mounting                                     Cat. No.          (`)       Pkg.      Mounting                                Cat. No.            (`)        Pkg.
                            (A)                                                                         (A)
 (Operation)                                                  Per Unit   (Nos.)     (Operation)                                               Per Unit    (Nos.)
                         0.23-0.41         CS96357OOFO         2420       10                              Direct Mounting on ML 1.5 Contactors
                         0.45-0.78         CS96357OOJO         2420       10                         0.15 - 0.25         SS91858OODO           6710         10
 RX                       0.78-1.2         CS96357OOLO         2420       10                         0.25 - 0.4          SS91858OOFO           6710         10
 (Directly                 1.2-1.9         CS96357OONO         2420       10                         0.4 - 0.65         SS91858OOHO            6710         10
 Operated)                                                                                             0.6 - 1           SS91858OOKO           6710         10
                           1.8-2.8         CS96357OOPO         2420       10        ML 1
                           2.6-3.6         CS96357OOQO         2420       10        (Directly          1 - 1.6          SS91858OOMO            6710         10
 Direct
                                                                                    Operated)         1.5 - 2.5          SS91858OOPO           6710         10
 Mounting on               3.6-5.2         CS96357OOSO         2420       10
 MX Contactors              4.8-7          CS96357OOTO         2420       10                           2.5 - 4           SS91858OORO           6710         10
                           6.4-9.7         CS96357OOVO         2420       10                           4 - 6.5           SS91858OOTO           6710         10
                          8.2-12.1         CS96357OOAO         2420       10                           6 - 10            SS91858OOVO           6710         10
                                                                                                      10 - 16            SS91858OOBO           6710         10

Type MU-2P (2 Pole)                                                                                   11 - 18            SS91858OOCO           6710         10
                                                                                                                 Direct Mounting on ML 2/3 Contactors
                                                                                    ML 2 / ML 3        9 - 14            SS91859OOAO           9930         10
                                                                                    (Directly          13 - 21           SS91859OOCO           9930         10
                                                                                    Operated)         20 - 32            SS91859OOEO           9930         10
               MU-2P                                                                                  28 - 42            SS91859OOFO           9930         10

 Type of             Relay Range                               M.R.P.      Std.     Type of         Relay Range                                M.R.P.       Std.
 Mounting                                   Cat. No.            (`)        Pkg.     Mounting                                 Cat. No.           (`)         Pkg.
                         (A)                                                                            (A)
 (Operation)                                                  Per Unit    (Nos.)    (Operation)                                               Per Unit     (Nos.)
                                           MU 2P (2 Pole)                                                                  MU 2P (2 Pole)
 Direct                1 - 1.6A           CS90207OOMO          1130            1    Direct           11 - 18A            CS90207OOCO           1260           1
 Mounting on           1.5 - 2.5A         CS90207OOPO          1130            1    Mounting on      13 - 22A            CS90207OODO           1260           1
 MU-2P                 2.5 - 4A           CS90207OORO          1130            1    MU-2P            16 - 26A            CS90207OOBO           1260           1
 Contactor             4 - 6.5A           CS90207OOTO          1130            1    Contactor        20 - 32A            CS90207OOEO           1580           1
                        6 - 10A           CS90207OOVO          1130            1                     26 - 40A            CS90207OOFO           1580           1
                        9 - 14A           CS90207OOAO          1130            1



Accessories for Thermal Overload Relays [8538]

Accessories for Thermal Overload Relays                                            Relay Reset Cord for MN & RTO relay



Relay Mounting Kit      Kit for Mounting MN5 Relay       Din Rail Mounting Kit
                                                              MN2 Relay                 400 mm        650 mm                900 mm             1200 mm
                                                              M.R.P.   Std.                                                                 M.R.P. (`)   Std. Pkg.
                                                                                    Description                               Cat. No.
 Description                                  Cat. No.         (`)     Pkg.                                                                  Per Unit     (Nos.)
                                                             Per Unit (Nos.)
                                                                                    MN Relay reset cord - 400mm           SB94207OOOO         1430          1
 Push button extn. unit for MN 2 Relays    SS94968OOOO         115       100
 Kit for Mounting MN 2 Relay on                                                    MN Relay reset cord - 650mm            SB94208OOOO         1490          1
 ML 1.5 contactor                          SS94701OOOO         395       50

 Kit for Mounting MN 2 Relay                                                       MN Relay reset cord - 900mm            SB94209OOOO         1525          1
 separately (Direct Mounting Type)         SS94700OOOO         395       50
                                                                                   MN Relay reset cord - 1200mm           SB94210OOOO         1715          1
 Kit for Mounting MN 5 Relay on
 MNX 95 / 110 / 140 contactor              SS94638OOOO         635       20        RTO Relay reset cord - 400mm           CS90941OOOO                       1
                                                                                                                                              1430
 Kit for Mounting MN 5 Relay on
 ML 2 / ML 3 contactor                     SS94151OOOO         410       20        RTO Relay reset cord - 650mm           CS90942OOOO         1490          1

 Kit for Mounting MN5 Relay on                                                     RTO Relay reset cord - 900mm           CS90943OOOO         1525          1
 ML 4 / ML 6 contactor                     SS94152OOOO         565       20
 DIN Rail Mounting Kit Relay on                                                    RTO Relay reset cord - 1200mm          CS90944OOOO         1715          1
 MN 2 Relay                                SS91887OOOO         310       50
                                                                                                                                            M.R.P.(`)    Std. Pkg.
                                                                                    Description                               Cat. No.
                                                                                                                                            Per Unit      (Nos.)

Separate Mounting Kit for                                                          RTO-1 Relay Separate Mounting Kit      CS96335OOOO          535          1

RTO Relay                                                                          RTO-2 Relay Separate Mounting Kit      CS96306OOOO         1260          1

                                                                                   RTO-3 Relay Separate Mounting Kit      CS96307OOOO         1800          1

                                                                                                                        Lauritz Knudsen, 15.08.2026               13
PDF page 21 Electronic Motor Protection Relay [8536]
View original PDF page ↗

Extracted reference text; use the original PDF to check column alignment, variants and price units.

Electronic Motor Protection Relay [8536]

Type REO - Electronic Overload Relay                                                                                      To Experience the Benefits of
                                                                                                                          REO Electronic Overload Relay
Features
› Protections:                             › Trip indication
  » Overload                               › Selectable Trip class - 10A, 10,
                                                                                                                                                Click or Scan
  » Single Phasing, Phase unbalance          20, 30 as per IEC 60947-4-1
  » Locked Rotor                           › Conforms IS/IEC 60947-4-1 & IEC 60947-4-1
  » Earth Fault in REO 1.1G & REO 4G


                                                                                                                    With in-built earth fault
                                                                 Without earth fault protection                           protection
                                               Relay                                                                                                     Std.
                         Type of               Range                                                                                                     Pkg.
 Model                  Mounting                                                        M.R.P.       Model                               M.R.P.
                                                (A)                   Cat. No.           (`)                          Cat. No.            (`)           (Nos.)
                                                                                       Per Unit                                         Per Unit

                                             0.15 - 0.75          CS90418OOJO           10540                      CS90423OOJO           17570            10
                      Direct                   0.6 - 3            CS90418OOQO           10540                      CS90423OOQO           17570            10
 REO 1.1                                                                                            REO 1.1G
                    Mounting on
                     MO 9-45                   2.4 - 12           CS90418OOLO           10540                      CS90423OOLO           17570            10
                                                9 - 45            CS90418OOGO           11830                      CS90423OOGO           18160            10

 REO 4                  Separate               18-90              CS90418OOUO           31220        REO 4G        CS90423OOUO           31520            1
                        Mounting               72-360             CS90418OORO           42780                      CS90423OORO           42940            1


Type REO - Electronic Over Current Relay
Electronic Overcurrent Relay (EOCR) is a type of Electronic relay that has tripping based on Definite mean time characteristics.
The tripping of relay is decided by trip time selected by user.

Features
› Protections:                              › Settable start time (5s, 10s, 20s, 40s)
  » Overload                                  and trip time (2s, 4s, 8s, 16s)
  » Single Phasing, Phase unbalance         › Trip indication
  » Locked Rotor                            › Conforms IS/IEC 60947-4-1 & IEC 60947-4-1

                            Relay                           M.R.P.     Std.       Accessories for REO - Electronic Overload Relay
 Model        Type of       Range         Cat. No.           (`)       Pkg.
             Mounting                                                                                                                                    Std.
                             (A)                           Per Unit   (Nos.)                                                                 M.R.P.
                                                                                    Description                             Cat. No.          (`)        Pkg.
                          0.15 - 0.75   CS91911OOJO         13540       1                                                                   Per Unit    (Nos.)
              Direct        0.6 - 3     CS91911OOQO         13540       1
 REO 1.1c                                                                           REO Relay Reset Cord - 400mm        CS90425OOOO             1430      1
            Mounting on
             MO 9-45       2.4 - 12     CS91911OOLO         13540       1           Separate Mounting Kit for
                                                                                    REO 1.1/1.1G/1.1c Relay             CS96335OOOO              535      1
                            9 - 45      CS91911OOGO         13540       1




                                                                                                                    Lauritz Knudsen, 15.08.2026                 14
PDF page 22 Illustrated catalog page
View original PDF page ↗

Extracted reference text; use the original PDF to check column alignment, variants and price units.

This page is illustrated. Open the original PDF to view its contents.
PDF page 23 Microcontroller based Motor Protection Relay [8536]
View original PDF page ↗

Extracted reference text; use the original PDF to check column alignment, variants and price units.

Microcontroller based Motor Protection Relay [8536]

eMPR150 - Electronic Motor Protection                                         eMPR300 - Electronic Motor Protection
Relay                                                                         Relay with Built-in Earth Fault Protection
                              › Protections                                                                 › Protections
                                » Overload                                                                    » Overload
                                » Locked Rotor                                                                » Locked Rotor
                                » Single Phasing, Current Unbalance,                                          » Single Phasing, Current Unbalance,
                                » Under Current                                                               » Under Current
                              › Inbuilt CT’s (1 A to 88 A)                                                    » Earth Fault
                              › Trip indication                                                               » Phase Sequence Reversal
                              › Test facility                                                               › Inbuilt CT’s (1 A to 88 A)
                              › Site Selectable – Fail-safe / Non                                           › Trip indication
                                   Fail-safe mode                                                           › Test facility
                              › Selectable trip class - 10A, 10, 20                                         › Site Selectable Phase Sequence -
                                   and 30 as per IEC 60947-4-1                                                    RYB/ RBY
                                                                                                            › Site Selectable – Fail-safe / Non
                                                                                                                  Fail-safe mode
                                                                                                            › Selectable trip class - 10A, 10, 20
                                                                                                                  and 30 as per IEC 60947-4-1


                                                                  M.R.P.                                                                           M.R.P.
                        Thermal O/L     Device                                Model       Aux.Supply Thermal O/L       Device       Cat. No.
Model      Aux.Supply                                Cat. No.      (`)                                                                              (`)
                         Range (A)      Code                                                          Range (A)        Code
                                                                 Per Unit                                                                         Per Unit
                           1-5.5                  EMPR150XAAO      4480                                   1-5.5                  EMPR300XAAO      11760
              110V         4-22                   EMPR150XABO      6830                     110V          4-22                   EMPR300XABO      14110
               AC                                                                            AC
                                                                                                         16-88                                    16460
eMPR150
                           16-88       49, 51LR, EMPR150XACO
                                                                   9180       eMPR300                                 49, 51LR, EMPR300XACO
                           1-5.5        37, 46   EMPR150XBAO       4480                                   1-5.5       64, 37, 46 EMPR300XBAO      11760

              230V         4-22                   EMPR150XBBO      6830                     230V          4-22                   EMPR300XBBO      14110
               AC                                                                            AC
                           16-88                  EMPR150XBCO      9180                                  16-88                   EMPR300XBCO      16460

eMPR selection must be done as per Line Current of Motor                      eMPR selection must be done as per Line Current of Motor



eMPR300D - Electronic Motor Protection                                        eMPR300I - Electronic Motor Protection Relay
Relay with inbuilt display                                                    with inbuilt display & Modbus RTU Communication
One solution for both EOLR and EOCR applications                              One solution for both EOLR and EOCR applications
                           › Protections                                                                    › Protections
                             » Overload                                                                       » Overload
                             » Locked Rotor                                                                   » Locked Rotor
                             » Single Phasing, Current Unbalance,                                             » Single Phasing, Current Unbalance,
                             » Dry Run Protection with Programmable                                           » Dry Run Protection with Programmable
                                Under Current                                                                      Under Current
                              » Earth Fault                                                                       » Earth Fault
                              » Phase Sequence Reversal                                                           » Phase Sequence Reversal
                              » Overcurrent                                                                       » Overcurrent
                           › 7 Segment LED Display                                                          › 7 Segment LED Display
                           › Inbuilt CT’s (1 A to 88 A)                                                     › Inbuilt CT’s (1 A to 88 A)
                           › 5 trip records                                                                 › 5 trip records
                           › Test facility                                                                  › Test facility
                           › Site Selectable – Fail-safe / Non                                              › Site Selectable – Fail-safe / Non
                              Fail-safe mode                                                                      Fail-safe mode
                           › Selectable trip class - 10A, 10, 20                                            › Selectable trip class - 10A, 10, 20
                              and 30 as per IEC 60947-4-1                                                         and 30 as per IEC 60947-4-1
                                                                                                            › Inbuilt Communication port
                                                                                                                  Modbus - RS-485

                                                                    M.R.P.                                                                       M.R.P.
Model       Aux.Supply Thermal O/L       Device       Cat. No.       (`)      Model       Aux.Supply Thermal O/L        Device       Cat. No.     (`)
                        Range (A)        Code                      Per Unit                           Range (A)         Code                    Per Unit
                            1-5.5                   EMPR300DCAO 12390                                     1-5.5                    EMPR300ICAO 17850
         85-265V                        37, 46, 49, EMPR300DCBO 14600                      85-265V                     37, 46, 49, EMPR300ICBO 20060
eMPR300D                    4-22                                              eMPR300I                    4-22        51LR, 51, 64
           AC                          51LR, 51, 64                                          AC
                            16-88                   EMPR300DCCO 16800                                     16-88                    EMPR300ICCO 22260

eMPR selection must be done as per Line Current of Motor                      eMPR selection must be done as per Line Current of Motor


                                                                                                                    Lauritz Knudsen, 15.08.2026        16
PDF page 24 Microcontroller based Motor Protection Relay [8536]
View original PDF page ↗

Extracted reference text; use the original PDF to check column alignment, variants and price units.

Microcontroller based Motor Protection Relay [8536]

Application Schemes : eMPR150, eMPR300, eMPR300D, eMPR300I
            R                                                    R                                                        R
            Y                                                    Y                                                        Y
            B                                                    B                                                        B

                SCPD                                                  SCPD                                                    SCPD


                                                                                        In case of Reversible starters;                          eMPR must sense Line current
                                                                                        eMPR must be placed before                               in case of STAR-Delta Starter
                                                                                        the reversing contactors.




     Contactor                                               Forward                             Reverse
                                                            Contactor                           Contactor
                                                                                                                   Line
                                                                                                                 Contactor
                                                                                                                                               Delta           Star
                                                                                                                                             Contactor       Contactor

                                                                                                                                      3Ø
                                                                                                                                     Motor


                        3Ø                                                     3Ø
                       Motor                                                  Motor



                       DOL                                                     RDOL                                                    Star - Delta


eMPR300D or eMPR300I with External 5P10 Class CTs for Motors with FLC > 88 Amp




Compact Motor Protection Relay - MM10                                                     Draw-out Motor Protection Relay - MPR21
Features                                                                                  › MPR21 – 37, 46, 48, 49, 50BF, 50, 51, 50N, 51N, 51LR, 64, 66, 74TCS.
› Flush Mounting with display                                                             › Microcontroller-based design
› Last trip data recording                                                                › Draw-out enclosure.
› Protections:
                                                                                          › CT rating#- 1A/ 5A (site selectable)
  » Thermal Overload with pre-alarm
  » Short Circuit                                                                         › Display of 250 event and 30 Trip records
  » Earth fault                                                                           › 128*64 graphical display
  » Phase loss, Unbalance, Phase reversal                                                 › Modbus RS-485 Communication
  » Under Current                                                                         › Front Micro USB port for numrAL Suite
  » Prolong starting, Locked Rotor

                   Aux.                                                       M.R.P.                                                                                      M.R.P. (`)
                                  CT#       Device                                            Model    Aux. Supply (V)          Communication              Cat. No.
    Model                      secondary                   Cat. No.            (`)                                                                                         Per Unit
                  Supply                     code
                                                                             Per Unit
                                                                                                         20 - 60V DC            Modbus RS 485            NRMPR2A28RA        69000
                                           37, 46, 49,                                     numrAL
                110 - 240 V                                                                MPR21        85 - 265V AC,
    MM10*                       5 Amp       50 / 51,     MM10240E005         46640                                              Modbus RS 485            NRMPR2B28RA        69000
                 AC / DC                                                                                87 - 265V DC
                                            51LR, 64
                                                                                          #
#
 - Protection Class CT                                                                     - Protection Class CT
*- Available till stock last
                                                                                                                                       Lauritz Knudsen, 15.08.2026               17
PDF page 25 Illustrated catalog page
View original PDF page ↗

Extracted reference text; use the original PDF to check column alignment, variants and price units.

This page is illustrated. Open the original PDF to view its contents.
PDF page 26 iMMR - Intelligent Motor Management Relay [8536]
View original PDF page ↗

Extracted reference text; use the original PDF to check column alignment, variants and price units.

iMMR - Intelligent Motor Management Relay [8536]

                                  Display Unit                              iMMR is a comprehensive Motor protection, control and monitoring
                                                                            relay for intelligent MCC’s

                                                                            “Besides control, protection and diagnostics, iMMR provides accurate
                                                                            real time data for analytics and insights into the performance of plant
                                                                            and process”

                                                                            Features
                                                                            › Comprehensive Current & Voltage based Protections
                                                                            › 20 nos. of last trip records, 100 event records and 20 IRF Records
                                                                                        are available
                                                                            › Preprogrammed Starter logics reduces manufacturing and
                                                                                        commissioning time
                                                                            › Software iMMR Suite is available for Easy and effective
                                                                                        configuration and monitoring
                                                                            › Ethernet IP, Profinet, Modbus RTU, Modbus TCP/IP and Profibus-
                                                                                        DP protocols available for seamless integration with DCS/PLC
                                                                            › Redundant network for seamless Motor control and monitoring,
       iMMR Main Unit                                   CT Unit                         with Profinet/ Ethernet IP



                                Description                                                                                                          M.R.P. (`)
 Product                                                                                                                   Cat. No.
                                                                                                                                                      Per Unit

                                iMMR MODBUS RTU 85-265 VAC/DC                                                            CS91244OOOO                  30000

                                iMMR PROFIBUS-DP 85-265 VAC/DC                                                               *Available On Request
 Main Unit                      iMMR MODBUS TCP/IP 85-265 VAC/DC                                                             *Available On Request

                                iMMR Ethernet IP 85-265 VAC/DC                                                               *Available On Request

                                iMMR Profinet 85-265 VAC/DC                                                                  *Available On Request

                                CT1 (0.3-3A) with 15 cm cable                                                            CS91245OOOO                   6900

 CT Unit                        CT2 (2.5-25A) with 15 cm cable                                                           CS91246OOOO                   9200

                                CT3 (7-70A) with 15 cm cable                                                             CS91247OOOO                  14600

                                CT1 (0.3-3A) + VT with 15 cm cable                                                       CS91249OOOO                  15900
 CTVT Unit                      CT2 (2.5-25A) + VT with 15 cm cable                                                      CS91250OOOO                  18700

                                CT3 (7-70A) + VT with 15 cm cable                                                        CS91251OOOO                  24600

 Display Unit                   iMMR Display unit without cable                                                          CS91253OOOO                  16000

                                iMMR Display Cable - 1 meter                                                             XK13128OOOO                   1400
 Display Cable
                                iMMR Display Cable - 2 meter                                                             XK13129OOOO                   2100

                                iMMR EXP 4DI + 2DO with 10 cm cable                                                          *Available On Request

                                iMMR EXP 6DI 110V/240V with 10cm cable                                                       *Available On Request
 Expansion Unit
                                iMMR EXP Earth Leakage + 2DI + 2DO with 10 cm cable                                          *Available On Request

                                iMMR EXP 2AI + 1AO with 10 cm cable                                                          *Available On Request

* Please contact our nearest branch for details

iMMR with external CT’s for Motors >37kW

                                         S1

                                         S2

                        -/5 Amp                   S1
                        Class 5P10
                                                  S2

                                                       S1

                                                                                                CT2          Main Unit
                                                       S2




                             Contactor
                                                                            Pass Through CT


                                                                                                                                      Display Unit
                                                                                                      CT Cable


                                         U1   V1       W1

                                              M
                                                                                                                          Lauritz Knudsen, 15.08.2026             19
PDF page 27 iMMR selection guide
View original PDF page ↗

Extracted reference text; use the original PDF to check column alignment, variants and price units.

iMMR selection guide



    Main Unit
                     +            CT / CTVT
                                     Unit
                                                   +        Display Unit
                                                                            +          Display Cable
                                                                                                       +      Expansion
                                                                                                                 Unit
                                                                                                                            =              iMMR
                                                                                                                                            for
                                                                                                                                         one motor




                                 For Current                                                                  Add up to 5
     Select                   based protection                           Select a panel                       Expansion
   Main Unit                   select CT Unit.                                                                                           Complete
                                                                            mounted                              Unit
   based on                     For Current &                                                                                            package
                                                                      Display Unit & Cable                      based
    required                   Voltage based                                                                                            selection of
                                                                       for monitoring and                     on DI/DO &
 communication                   protection                                                                                               iMMR.
                                                                        parametrization.                        AI/AO
   protocol.                        select                                                                   requirement.
                                 CTVT Unit.




Cat.no. selection guide
Modbus RTU communication and Current based protection and metering
                                                   Main Unit -                                                                   Display Cable -
 Motor Rating               Total MRP                                            CT Unit                Display Unit
                                                   Modbus RTU                                                                       2 meter

  <1.1 KW                     55000                CS91244OOOO               CS91245OOOO               CS91253OOOO               XK13129OOOO

 1.1 KW to 11 KW              57300                CS91244OOOO               CS91246OOOO               CS91253OOOO               XK13129OOOO

 11 KW to 37 KW               62700                CS91244OOOO               CS91247OOOO               CS91253OOOO               XK13129OOOO

 >37 KW                       57300                CS91244OOOO               CS91246OOOO*              CS91253OOOO               XK13129OOOO
* with External Protection class CT ,s of -/5Amp



Modbus RTU communication and Current + Voltage based protection and metering
                                                        Main Unit -                                                               Display Cable -
 Motor Rating                   Total MRP                                               CTVT Unit           Display Unit
                                                        Modbus RTU                                                                   2 meter

  <1.1 KW                         64000                CS91244OOOO                   CS91249OOOO           CS91253OOOO            XK13129OOOO
 1.1 KW to 11 KW                  66800                CS91244OOOO                   CS91250OOOO           CS91253OOOO            XK13129OOOO
 11 KW to 37 KW                   72700                CS91244OOOO                   CS91251OOOO           CS91253OOOO            XK13129OOOO

 >37 KW                           66800                CS91244OOOO                   CS91250OOOO*          CS91253OOOO            XK13129OOOO
* with External Protection class CT ,s of -/5Amp




                                                                                                                       iMMR Main Unit




                                                                                                                       iMMR Display Unit




                                                                                                                       iMMR Display Cable




                                                                                                                   }   iMMR CT/CTVT Unit
                                                                                                                       with 15 cm cable




                                                                                                               Lauritz Knudsen, 15.08.2026             20

BEFORE YOU SPECIFY

Make an informed choice.

LET’S GET THE SPECIFICATION RIGHT

From your shortlist
to a clear quote.

Share the catalog number, rating and quantity. We’ll confirm the current price, availability and lead time.

Send your requirement ↗